CDVI ievo IFACE User manual

ievo iface™Facial Recognition Terminal
IFACE™
EN
WARRANTY
YEAR
5

EN EN
2
IFACE™
ievo iface™ Facial Recognition Terminal
1] CONTENTS
2] INTRODUCTION 3
About this Manual 3
Conventions 3
3] PACKAGE CONTENTS 3
4] PRODUCT PRESENTATION 4
Technical Specications 4
Parts and Functions 5
Accessories 5
Terminals 6
Touch Screen 7
5] INSTALLATION 7
Installation Requirements 7-9
Installation Procedure 10
6] WIRING 11
Power Connection 11
Network Connection 12
Relay Connection 12-15
7] ENROLLMENT 15
8] AUTHENTICATION 16
9] ADVANCED SETTINGS - OSD MENU LIST 17
User 17
Device 17
Communication 18
Display 19
Authentication 19
Log 19
Title Page

EN EN
3
IFACE™
ievo iface™ Facial Recognition Terminal
2] INTRODUCTION
About this Manual
ifaceTM is an advanced face recognition terminal that provides highly accurate face
recognitioninanembeddedsystem.Thismanualcontainsthedescriptionsandoperational
instructions for ifaceTM device. It is intended and written for system administrators who
are in charge of overall operation including installation and management. We recommend
you familiarise yourself with this manual in order to make use of the product correctly
and effectively.
• The gures and screenshots in this guide are given for illustration purposes only
and may differ from the actual product.
• Due to continuous technological improvements, the guide may not contain the
most up-to-date information. For further information not covered in this guide,
Conventions
Symbol Name Description
WARNING Indicates information that should be followed with the utmost care.
Failure to comply with a warning could cause severe damage to the
equipment or injury to personnel.
CAUTION Indicates a potentially hazardous situation which, if not avoided,
could result in equipment damage, data loss, performance
degradation, or unexpected results.
IMPORTANT Emphasises essential information required for user success.
NOTE Provides important supplemental information that might enhance
users' understanding or alternative steps to accomplish their goals.
TIP Provides optional information to help users be more successful in
their tasks
3] PACKAGE CONTENTS
Main unit Mounting
plate Power cable Relay cable GPI cable Wiegand
cable RS-485
cable
1 1 1 1 1 1 1
AC adapter
(optional) Power cord
(optional) Diode Manual
1 1 1 1

EN EN
4
IFACE™
ievo iface™ Facial Recognition Terminal
4] PRODUCT PRESENTATION
Technical Specications
Feature Description
CPU ARM Cortex A53 OctaCore (8 core) operating at 1.4GHz
Memory 2GB RAM, 8GB Flash
Number of cameras Two
Display 5” LCD with touch
IR LED YES, for low ambient light levels and supplementary face detection
support
White LED YES, for adjunct lighting of face
Ethernet Standard 10/100 BaseT and GigE
Dimensions 100 x 200 x 36 mm
Weight 450 g (1 pound)
Capture range 40 cm to 200 cm
User’s height range 145 cm to 210 cm (with system installed at 135 cm)
Enrollment speed About 5 seconds
Recognition speed About 1 second total in 1:N mode with 20,000 subjects in local database
Enrollment 20,000 users total DB size (max 20,000 users in 1:N mode)
Fake face detection YES
Audio YES (Speaker only)
Input power 15Vdc
RF Card reader ISO/IEC 14443 reader for MIFARE®, DESFire®andFeliCa®cards(standard)
Connections RJ45 for LAN, Wiegand IN/OUT, GPIO (3), RS485, dry contact relay, SIM
Socket (optional)
USB Only for host / service modes and data back up.
Temperature Operating: 0°C to 45°C
Non-operating: -20°C to 60°C
Humidity Operating: 8% to 85% relative humidity, non-condensing
Non-operating: 8% to 90% relative humidity, non-condensing
71.5 mm
142 mm
105 mm
53 mm
22 mm
8 mm
60 mm
43 mm
38 mm
36 mm
200 mm
177 mm
100 mm

EN EN
5
IFACE™
ievo iface™ Facial Recognition Terminal
Parts and Functions
Item Description
Camera Captures the face images
IR LED Illuminates the face using the NIR lighting when capturing the faces
Touch screen Shows preview images before capture and provides a graphical interface
for enrollment and device conguration
White LED Gives supplemental light in dim light
RF card reader Indicates the area where RF cards can be read
Ambient light sensor Detects changes of light in the surrounding environment
Speaker Delivers sound from the device
Mounting plate socket Attaches the unit the mounting plate
USB port Connects a USB ash drive for back up and restoration of face database
Accessories
Item Description
Mounting bracket
RF card writer Dual RF card reader/writer
RF card MIFARE®, DESFire®, FeliCa®

EN EN
6
IFACE™
ievo iface™ Facial Recognition Terminal
Item Description
Tripod socket (not supplied) Attaches a tripod (or equivalent mount) with a standard 1/4-20 UNC
screw
Tamper switch Starts an alarm, if congured, when a physical tampering attempt is
detected (see p.18 for more information)
SIM card slot (optional) Indicates area where a SIM card can be connected
Removable tabs Allows for routing of power, Ethernet and other cables to go through the
openings on the side of the unit, rather than the back, when tabs are
removed. (e.g. useful in tabletop deployments)
Ethernet port Connects an ethernet cable
Power plug Connects the power cable to the unit
Factory reset button Restores the device to its original manufacturer settings
RS-485 termination switch Provides termination when the device is located at the physical end of
RS-485 wiring
RS-485 Connects the RS-485 cable
Wiegand input or output Connects the Wiegand cable either as input or as output selectively
GPI input Connects the GPI cable
Terminals
Tripod socket
Tamper swtich
SIM card slot (optional)
SIM card slot (optional)
Removable tabs x3

EN EN
7
IFACE™
ievo iface™ Facial Recognition Terminal
Touch Screen
No. Item Description
1 Status indicator Shows the status of network connection and third party application
• White: Online
• Red: Ofine, not usable
2 Settings button Enters the device setup menu screen
3 Enrollment button Enters the device setup menu screen
4 Preview screen Gives a preview of subject’s face
5 Home button Goes to the home screen
6 Back button Goes back to the previous menu screen
7 Settings Shows settings menu – User, Device, Communication, Display,
Authentication, Log
5] INSTALLATION
This chapter gives the information about the requirements and the prerequisites for
installing ifaceTM and the installation procedures.
Installation Requirements
Before installation, make sure that the following requirements are met.
If it is required to use the device in outdoor or extreme environments:
• Avoid locations that are exposed to backlighting, direct sunlight, or other strong
illumination.
• Choose a location with moderate ambient light.
The ifaceTM is designed and intended for indoor use only. The device is not
weatherproof and must not be exposed to water, ice, extreme temperatures or
other adverse weather conditions.
A CDVI Group Brand

EN EN
8
IFACE™
ievo iface™ Facial Recognition Terminal
Cable Requirements
• Use a stable power supply adapter of 15Vdc (± 5%) with a minimum 2A.
• Make sure that the power cable is as short as possible and that you have correct wire
gauge (22 AWG or smaller in number)
• Use CAT5 or later for the ethernet cable.
Input
Voltage
(V)
Wire gauge
(AWG)
Power cable length (m)
Recommended Max
12
16 26.3 37.9
18 15.9 23.8
20 10.0 15.0
22 6.3 9.4
15 20 25.0 37.5
22 15.7 23.6
24 20 70.1 105.1
22 44.0 66.0
• Determine the height at which you install the device;
The recommended mounting height is 135 cm (53 inches) from the oor to the
bottom of the device. This covers a person’s height from 140 cm (55 inches) up
to 190 cm (75 inches) at a distance of 55 cm (22 inches) from the device.

EN EN
9
IFACE™
ievo iface™ Facial Recognition Terminal
Tool Requirements
The following tools can be necessary for installation and are not supplied by default.
Purpose Name Tool Note
General
Concrete
wall mount
Screw driver Cross head
Tape ruler For measuring
the installation
height
Cutting plier
Electric drill With a drill bit
and anchor
bolts
Marker
Hammer

EN EN
10
IFACE™
ievo iface™ Facial Recognition Terminal
Installation Procedure
Wall mount
You can install the device onto a wall directly by using the mounting plate.
1. Remove the screw that attaches ifaceTM to
the mounting plate and disassemble the
plate.
Keep the screw because it will be used to
attach them together again. For concrete walls, follow these steps:
1. Put marks on the wall through the plate’s
screw holes by using a marker.
2. Drill the marked points by using an
electric drill.
3. Attach the anchor bolts to the holes by
using a hammer.
4. Attach the plate to the wall with the
screws.
1. Put the mounting plate at the pre-
determined position and attach the plate
onto the wall with the screws (M4 x 8 min).
2.
1. Connect the power cable and peripheral
cables, if necessary, to the connectors in
the rear panel. (See Connecting Cables for
more information)
3. 1. Note: Step to be included only for conduit
mounting.
4.
1. Put the device onto the installed plate,
slide it downward, and attach it with the
screw (M3 x 6)
5.
Wall mounting points
Remove one or more plastic tabs to allow
the wire routing and let the cables go
through the openings.

EN EN
11
IFACE™
ievo iface™ Facial Recognition Terminal
Gang box mount
You can also install the device on a gang box (outlet box) by using the mounting plate.
1. Remove the screw that attaches ifaceTM to
the mounting plate and disassemble the
plate.
Keep the screw because it will be used to
attach them together again. Make sure that the outgoing cables from the
gang box go through the rectangular opening
in the plate.
6] WIRING
Power Connection
DC Power Supply
1. Put the mounting plate onto the gang box
and attach it to the box with the screws
(M4 x 8).
2.
1. Connect the power cable and peripherals
cables, if necessary, to the connectors in
the rear panel. (See Connecting Cables for
more information)
3. 1. Put the device onto the installed plate,
slide it downward, and assemble with the
screw (M3 x 6)
4.

EN EN
12
IFACE™
ievo iface™ Facial Recognition Terminal
Network Connection
RJ-45 connector for 10/100/1000 Base-T Ethernet communication, minimum CAT5
cable.
Relay Connection - Locking
There are two types of dead-bolt door lock connections and conguration supported –
fail safe and fail secure.
Relay Connection
Relay
GPI
1
2
3
Normally Open (NO) - Black
Common (COM) - Red
Normally Closed (NC) - Grey
1
2
3
4
GPI 0 - Red
GPI 1 - Green
GPI 2 - Yellow
Ground (GND) - Black
• Use different power supplies for the ifaceTM and the door lock.
• Install the diode at both ends of the circuit (as shown in the gure below),
close to the door lock to protect the relay contact from the reverse current
that occurs when the door lock works.
• Make sure that the diode direction is correct.
Wire Gauge: 24 AWG
Wire Gauge: 24 AWG

EN EN
13
IFACE™
ievo iface™ Facial Recognition Terminal
Fail Safe Conguration Fail Secure Conguration
Relay Connection - Automatic Door
Door Lock Door Lock
Pin Output Function
RELAY 1 Normally Open (NO)
2 Common (COM)
3 Normally Closed (NC)
GPI
1 GPI 0
2 GPI 1
3 GPI 2
4 Ground (GND)

EN EN
14
IFACE™
ievo iface™ Facial Recognition Terminal
Relay Connection - Alarm light
Internal relay interface with nominal switching capacity of 1A, 30Vdc or 0.3A, 120Vac,
resistive load.
GPI Connection
Exit
Button Door
Sensor
Fire
Detector
Pin Output Function
RELAY 1 Normally Open (NO)
2 Common (COM)
3 Normally Closed (NC)
Pin Output Function
GPI
1 GPI 0
2 GPI 1
3 GPI 2
4 Ground (GND)

EN EN
15
IFACE™
ievo iface™ Facial Recognition Terminal
Wiegand
Wiegand OUTWiegand IN
7] ENROLLMENT
1. Press the User button on the main screen.
2. Press Enroll at the bottom.
3. Type ID and Name.
4. Press one or more credential type buttons (Face, Card) to
add to the user.
• For Face, let the user stand in front of the device and
complete the face capture.
• For Card, put the card on the device’s card reader.
When the CSN (card serial number) appears on the
screen, press OK.
• Option: Select Bypass card to allow the user to get
access permssion by using a registered card alone
regardless of the authentication mode.
5. Press OK to complete the enrollment.
1
2
3
4
5
DATA 0 - IN - Green
DATA 1 - IN - White
DATA 0 - OUT - Blue
DATA 1 - OUT - Grey
Ground (GND) - Black
Wire Gauge: 24 AWG
This section explains how to enroll users in Standalone mode only. If you are using
the isync software, do not enroll users manually, as isync will clear manually
added users! Follow the isync manual for enrolling users in the isync software.

EN EN
16
IFACE™
ievo iface™ Facial Recognition Terminal
1. Position yourself in front of device, while
looking at screen. A white box appears
around the face when your face is detected.
8] AUTHENITCATION
ifaceTM detects and displays the subject’s
face over 2.0 meters from the system on the
high-resolution color display. The subject will
naturally walk toward the face capture range
(of 0.4 - 2m). Once the system recognises
the subject, the result will be displayed
immediately with an indication line over the
subject’s face image.
1. Authentication result is displayed at the
top of the screen depending on whether
or not your face is successfully recognised.
2.

EN EN
17
IFACE™
ievo iface™ Facial Recognition Terminal
9] ADVANCED SETTINGS - OSD MENU LIST
To enter the advanced setting menus of the ifaceTM, press the
Gear button on the main screen. The following options will be
displayed:
1. User
2. Device
3. Communication
4. Display
5. Authentication
6. Log
1. User
Sub-menu Description
Enroll Starts user enrollment
Delete Deletes users
Modify Edits user information by pressing a registered user
Search Finds users by ID
Sub-menu Options Description
Bio Fake face Selects the fake face detect option
Face image log Selects whether to show face image on event log
Date/ Time Time settings Congures device date and time
Door
Relay Selects whether to use relay
Open duration Congures time duration for door open relay
Use exit Selects a GPI port number connected to exit door button:
Not used, GPI Port 1, GPI Port 2, GPI Port 3
Exit type Selects contact state of the GPI port that exit door button
uses: NC, NO
Use alarm Selects a GPI port number connected to the alarm
sensor:Not used, GPI Port 1, GPI Port 2, GPI Port 3
Alarm type Selects contact state of the GPI port that the alarm
sensor uses: NC, NO
Use sensor Selects a GPI port number connected to the sensor: Not
used, GPI Port 1, GPI Port 2, GPI Port 3
Sensor type Selects contact state of the GPI port that the sensor
uses: NC, NO
Held on duration Types the acceptable door held open period
2. Device

EN EN
18
IFACE™
ievo iface™ Facial Recognition Terminal
3. Communication
Sub-menu Options Description
TCP/IP User DHCP Selects whether to use DHCP
IP Shows the device’s IP address
Subnet Shows the subnet mask
Gateway Shows the gateway address
DNS 1 Shows the DNS #1
DNS 2 Shows the DNS #2
Server User server Selects whether to use server
Server IP Types the server’s IP address
Port Types the server’s port number
Commute Uri Type server URI to receive T&A event logs from device
Sync Uri Type server URI to receive T&A event logs backed up by
Sub-menu Options Description
Tamper Modes Selects a tamper protection mode: Not used, Beep
mode, Secure mode
Device info Device name Congures the device name
Model Shows the model name
FW version Shows the device rmware version
APP version Shows the application version
MAC Shows the MAC address
S/N Shows the serial number
IOMicom version Shows the IO Micom revision number
H/W version Shows the hardware revision number
RF Micom version Shows the RF Micom revision number
Algo version Shows the algorithm revision number
Database User import Imports the user database from connected USB drive
User export Exports the user database to connected USB drive
Debug export Exports the debug data to connected USB drive
LED Signal Congures LED signal through EF-IO (Under
development)
Reset Device reboot Restarts device
Factory reset Resets all conguration settings and deletes all user data
Reset all cong Sets all conguration settings to default
Reset all users Deletes all user data
Standalone mode: If you select Secure mode, all the data and
settings are deleted permanently in the device when physical
tampering is detected / attempted.
isync software: The software will repopulate the device after data
deletion for all previously registered users.

EN EN
19
IFACE™
ievo iface™ Facial Recognition Terminal
4. Display
Sub-menu Description
Language Selects a display language
Time display Selects time notation between 12-hour and 24-hour clock
format: 12 hours, 24 hours
Menu timeout Select timeout for auto exit from menu display after
leaving it untouched
Screensaver Selects whether to use screensaver
5. Authentication
Sub-menu Options Description
Auth mode Mode Selects a authentication mode: Face only, Face or card,
Face and PIN, Card and face, Card and PIN
Bypass Allows unregistered users to access
Touch start Starts recognition by touching the screen
Recog threshold Adjusts matching threshold in recognition mode
(permitted value range: 90 to 100)
Increasing the value increases FRR (false rejection rate) whereas
decreasing the value increases FAR (false acceptance rate).
Recog distance Selects the distance from where face detection starts
TA Use T&A Selects whether to use T&A functions (for future
developments, dependant on your access control system)
Admin
password Use admin pw Selects whether to use admin password
Password Types admin password
Card Use CSN Selects CSN order on card reading: MSB, LSB
CSN order Selects CSN order on card reading: MSB, LSB
Wiegand Output type Selects Wiegand output type: Wiegand, Card, ID
6. Log
Sub-menu Options Description
Log info Total used Selects whether to use DHCP
Total count Shows the device’s IP address
Logo delete Delete log Deletes all the logs

www.cdvigroup.com
CDVI Group
FRANCE (Headquarters)
Phone: +33 (0) 1 48 91 01 02
CDVI FRANCE + EXPORT
+33 (0) 1 48 91 01 02
www.cdvi.com
CDVI AMERICAS [CANADA - USA]
+1 (450) 682 7945
www.cdvi.ca
CDVI BENELUX [BELGIUM - NETHERLANDS - LUXEMBOURG]
+32 (0) 56 73 93 00
www.cdvibenelux.com
CDVI GERMANY
+49 (0) 175 2932 901
www.cdvi.de
CDVI TAIWAN
+886 (0) 42471 2188
www.cdvichina.cn
CDVI SUISSE
+41 (0) 21 882 18 41
www.cdvi.ch
CDVI CHINA
+86 (0) 10 84606132/82
www.cdvichina.cn
CDVI IBÉRICA [SPAIN - PORTUGAL]
+34 (0) 935 390 966
www.cdviberica.com
CDVI ITALIA
+39 (0) 321 90 573
www.cdvi.it
CDVI MAROC
+212 (0) 5 22 48 09 40
www.cdvi.ma
CDVI SWEDEN
[SWEDEN - DENMARK - NORWAY - FINLAND]
+46 (0) 31 760 19 30
www.cdvi.se
CDVI UK [UNITED KINGDOM - IRELAND]
+44 (0) 1628 531300
www.cdvi.co.uk
CDVI POLSKA
+48 (0) 12 659 23 44
www.cdvi.com.pl
All the information contained within this document (pictures, drawings, features, specications and dimensions)
could be perceptibly different and can be changed without prior notice. - Jan 2022
*G0301ENXXXXV0X*
Reference : G0301ENXXXXV0X
Extranet : CDVI_IFACE_IM_01_EN_A4_C
Table of contents