TROUBLESHOOTING GUIDE
WARNING: To reduce the risk of electrical shock, DISCONNECT POWER CORDS before repairing
or replacing any internal components of the unit. Before any attempt to replace a component be sure to
check all electrical connections for proper connection.
PROBLEM PROBABLE CAUSE REMEDY
ADispensingunitunplugged. Reconnect dispensing unit.
BNo power from Terminal Block. Check the TerminalBlock for loose wire.
CDefective Bulb. Replace Bulb.
DDefective Ballast. Replace Ballast.
1
Light display
not lit.
ELooseBulbinsocket. Make sure bulb is seated properly in socket.
AWater supply OFF. Turn water ON.
BClogged inlet screen (Water Inlet Valve). Disconnect water line andclean inlet screen.
CInoperative Water Inlet Valve. Check connection, if needed replace Valve.
2
No water when
Rinse Switch is
ON. DLoose electrical connection. Check all electrical connections.
ANo product in Canister. Add product.
BAugernotworking. Engage Hopper/Nut to Motor Gear.
CDamaged, loose, or missing Agitator Gear. Replace Agitator Gear.
DInoperative Auger Motor or Relay. Check connections of Motor, Relay and/or Switch, if
needed replace components.
ECanister outlet clogged. Clean Hopper.
3
No product
when Dispense
Button is
pressed
FFaulty Coupling. Replace damaged Coupling components.
ALeakingWaterInletValve. Clean/check Water Inlet Valve fittings. Replace Water
Inlet Valve
if needed.
BInoperative Dispense Switch. Check Switch connections. Replace Dispense Switch if
needed.
CInoperative Rinse Switch. Check Rinse Switch connections.
Replace Rinse Switchif inoperative.
4
Water does not
shut off.
Water keeps
dispensing.
DClogged/stuckWaterDispenseValve. Clean or unclog Water Dispense Valve.
ReplaceDispenseValve if inoperative.
AWater Inlet Valve malfunction. Check Solenoid. Replace if necessary.
BDual Probe malfunction. Check Probe. Replace if necessary.
5
No water is
goingintotank
at all. CDual Probe Liquid Level Controller malfunction.
Check Controller. Replace if necessary.
ADual Probe malfunction. Check Probe. Replace if necessary.
BSolenoid (Water Inlet Valve) malfunction. Check Solenoid. Replace if necessary.
6
Water will not
water tank. CDual Probe Liquid Level Controller malfunction.
Check Controller. Replace if necessary.
AHeaterSwitchisOFF. Turn Heater Switch ON.
BThermostatisOFF. Turn Thermostat ON.
CLoose connection on Thermostat. Makesureallwires and terminals on Thermostat are
tight.
DHi-Limit Temperature Switch is defective Replace the Hi-limit switch.
7
Water is not
heatingupin
water tank.
EHeater is burned out or defective. Replace the Heater.