CEG ECO-MXA 404 Supplement

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 1
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
ELECTRIC MOTORS AND PUMPS
INSTALLATION AND OPERATING INSTRUCTION MANUAL
2YEAR WARRANTY
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
Manufactured to meet Australian and New Zealand standards
MUL
TI-STAGE WATER PUMP
WITH ELECTRONIC PRESS CONTROL
ECO-MXA

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
2
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
+40˚C
2YEAR WARRANTY
INTEGRATED
INTELLIGENCE
INTEGRATED
INTELLIGENCE
GENERAL 3
SUPPLIED WITH PRODUCT 3
PRODUCT DESCRIPTION 4
TECHNICAL DATA 4
APPLICATION 5
ENVIRONMENTAL PROTECTION 5
WARRANTY 5
SAFETY 6
GENERAL ELECTRICAL SAFETY 6
PERSONNEL QUALIFICATION 6
ALTERATIONS AND SPARE PART PROCUREMENT
ABNORMAL OPERATING CONDITIONS
TRANSPORT AND STORAGE
INSTALLATION FOR FLOODED SUCTION 8
INSTALLATION FOR LIFT SUCTION 9
MAINTENANCE
ELECTRONIC PRESSCONTROL 14
OPTIONAL EXTRAS 11
DIMENSIONAL DRAWING 5
6
6
6
INSTALLATION 6
ELECTRICAL CONNECTION 7
PRODUCT DESCRIPTION 14
FAULTS, CAUSES AND SOLUTIONS 19
CODE OF COMPLIANCE 20
10
TECHNICAL DATA 14
UNIT STARTING AND WORKING 14
STARTING 15
FUNCTIONING 15
SPARE PARTS 16
SUCTION GUIDE 7
3L PRESSURE TANK 11
3L PRESSURE TANK INSTALLATION 11
WATER HAMMER 11
ECO-PURE FILTER HOUSING 12
ECO-PURE FILTRATION CARTRIDGES 13
INSTRUCTIONS FOR CORRECT UNIT INSTALLATION 15
ECO-MXA 404 STAINLESS STEEL SELF-PRIMING JET PUMP 16
ECO-MXA 405 STAINLESS STEEL SELF-PRIMING JET PUMP 17
SERVICE REFERENCE INFORMATION 20
NOTES 18
-0°C +50°C
304
AISI
GLASS
REINFORCED
POLYMER

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 3
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
SUPPLIED WITH PRODUCT
GENERAL
Depending of your choice of model, the ECO-MXA is available in three dierent congurations
ECO-MXA BARE PUMP
- ECO-MXA pump
- 1.5 metre lead with NZ/AU compatible plug
- Installation and operating instructions
- Certied of conformity to AS/NZ standards
- Warranty card
ECO-MXA WITH ELECTRONIC PRESSCONTROL
- ECO-MXA pump
- Electronic PRESSCONTROL
- 25mm non-return valve
- 5m x 12mm thread seal tape
- 1.5 metre lead with NZ/AU compatible plug
- Installation and operating instructions
- Certied of conformity to AS/NZ standards
- Warranty card
ECO-MXA WITH ELECTRONIC PRESSCONTROL
& 3L PRESSURE TANK
- ECO-MXA pump
- Electronic PRESSCONTROL
- 3L pressure tank
- 25mm non-return valve
- 5m x 12mm thread seal tape
- 1.5 metre lead with NZ/AU compatible plug
- Installation and operating instructions
- Certied of conformity to AS/NZ standards
- Warranty card
Dear Customer,
Congratulations on your purchase of the CEG ECO-MXA water pump. Like all CEG products, we have developed them with
the help of the latest technology and they have been manufactured with the most advanced components. Please check the
following points upon receiving your pump:
- Check that no damage has occurred during the shipping process
- See page 4 for technical Table 1.0 to ensure the pump model is t for your purpose
Take the time to read the instructions carefully before using the ECO-MXA pump. We strongly recommend that you keep
this instruction manual in a safe place for future reference. Please ll in the service reference information on page 20 and the
warranty card supplied with product
These Safety marks are contained in these Instructions.
This symbol means danger. If not complied with it may
cause death or severe physical injury.
This symbol means caution. If not complied
with, this may result in damage to product.

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
4
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
TECHNICAL DATA
Water temperature range min / max 5°C- 40°C
Maximum suction lift 8.5 m
Max working pressure 10 bar
Inlet/outlet pipe connection 25 mm BSP / 1” Inch BSP
Motor speed 2900 RPM
Insulation Class F
IP protection IP 55
Sound pressure Level 61 dBA
Performance Curve
Max particle size 1 mm (non-abrasive material)
Electrical supply 220V - 240V, 50 Hz
With the ever increasing need for water and electricity to meet global demand and the continual increase in energy costs
to the consumer, thought had to be put into a new domestic water pump design with premium eciency. The method for
design of the ECO-MXA Premium Eciency Series was developed by focusing on the mechanisms causing water hydraulic
loss. The ECO-MXA was created for the Australian and New Zealand market using the latest CAD water hydraulic 3D design
technology and manufacturing processes that are currently only found in large commercial models. The ECO-MXA Series
Premium Eciency range are self-priming. All parts in contact with the liquid are made from long life, corrosion resistant
materials such as stainless steel AISI 304 and glass reinforced polymer. The ECO-MXA’s motor has an automatic built-in thermal
overload protector that switches o the motor on overload, then on again after a cooling down period.
PRODUCT DESCRIPTION
Electromagnetic compatibility (EMC) EN 60335-2-41
EN 61000-6-1
EN 61000-6-3
Table 1.1
Mechanical Seal Carbon / Ceramic
Ambient temperature 0°C - 50°C
Electrical connection AS/NZ plug tted to 1.5m lead
File Name: ECO-MXA_Series_CAD_left_top.SLD
File Description: CEG 3D CAD Water Hydraulic Design
File Name: ECO-MXA_Series_CAD_right_side.SLD
File Description: CEG 3D CAD Water Hydraulic Design
SolidWorks 2016 SolidWorks 2016
Graph 1.0
Table 1.0
Total Head
Capacity
lpm
M
ECO- MXA
404
ECO- MXA
405
20
10
50
60
20
40
30
40
60
100
120
140
80
Capacity
* = 10 lpm at 1.5bar (22psi)
Model
PC
PC

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 5
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
APPLICATION
The ECO-MXA pump is an inexpensive water supply unit suitable for domestic purposes such as; household water supply,
draining of tanks and containers, watering and sprinkling gardens from tanks and bores.
The ECO-MXA is a self-priming pump, making it suitable for pumping from water sources (e.g. underground tanks, bores,
streams) or ooded suction (e.g. above ground tanks). It must not be connected directly to civil water supply systems.
This pump is designed for residential clean water jobs only and cannot pass particles over 1mm, nor can it be used for a
continuous duty fountain pump nor intended for commercial use.
The ECO-MXA cannot be used for sea water, ammable, corrosive, explosive or dangerous liquids!!
Be careful not to exceed the recommended specications in the use of your ECO-MXA!
The ECO-MXA pump must be installed and serviced by qualied personnel only!
ENVIRONMENTAL PROTECTION
CEG is dedicated to a recovery and recycle service which simplies the disposal process for end users at
the completion of a products life, minimising the environmental impact. CEG is dedicated to minimising
its environmental footprint wherever possible and is continuously searching for improved ways to operate.
All ECO-MXA packaging material can be recycled, so we encourage you to do so responsibly. Old pumps
contain material that can be recycled, please arrange for the correct recycling of your old pumps.
WARRANTY
The ECO-MXA has a standard 2 year warranty. In the event of a warranty claim, please contact your local distributor and
submit claim with proof of purchase. We will repair potential failures of an ECO-MXA within the warranty period free of charge,
provided the failure is due to faulty material or manufacturing defects. Damage as a result of failing to comply with the
instructions in this manual will void warranty. lt is the operator’s responsibility to take all preventative measures (e.g. provision
of alarm systems, standby pump etc.) To avoid consequential damages such as ooding due to pump failure.
In the unlikely event that a problem should occur all products must be returned to base at customers cost, we will either repair
the product or replace at our discretion.
Approved uids for the ECO-MXA series are:
- Rainwater
- Domestic water
A
B
C
Dimensions (mm)
Model
ECO-MXA 404
ECO-MXA 405
A B
C H H1 H2 L
L1 L2
DNA DNM
108
108
191
191
88
88
217
223
190
190
90
90
426
482
151
175
251
275
25
25
25
25
DIMENSIONAL DRAWING
- Water without solid particles
- Well water/bore water
Table 1.2
Drawing 1.0
Table 2.0
Model
Power Max
head
Max
capacity Inlet Outlet
W (P1) W (P2) m lpm mm inch mm inch
ECO-MXA 404PC 1400 1000 50 120 25 1 25 1
ECO-MXA 405PC 2000 1500 60 133 25 1 25 1
Weight
kg
11.4
15.6

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
6
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
INSTALLATION
The pump must operate in strict compliance with local water supply regulations. Before installation, be certain that the pump’s
power source is disconnected.
The installation location must be:
- Easy to reach
- Well ventilated, covered for weather protection, dry and frost-free
- On a concrete pad or directly on a smooth and horizontal oor
- Adequately ventilated
- A location where you a familiar with the maximum diameter of the particles in the water (a pre-lter screen may be
required in some locations)
- For suction lift installation please refer to Drawing 2.0
- Non-return valve must be installed on the inlet side of the pipe, as close to the water source inlet as possible
- If a non-return valve is required at the end of the suction line. lt must be located no less than 300mm below the
lowest water level and 100mm from the bottom (a pre-lter screen may be required). See Drawing 2.0
- Inlet and outlet piping to be provided by operator
- When using solid pipe connections the pump must be rmly xed to the oor
- If not rmly xed, exible connectors must at least be used for inlet and outlet ports
- The suction pipe must be fully airtight and be installed free of stress, steadily rising towards the pump
- Discharge pipe connections must be free of stress on the pump
TRANSPORT AND STORAGE
When transported and stored, the pump must not be subjected to temperatures outside the limits of 0 - 50 °C. Pump must be
stored in a dry, sheltered place.
ABNORMAL OPERATING CONDITIONS
Operational safety of the pump is only ensured if the pump is used in accordance with technical data Table 1.0. The limits
stated there must not be exceeded under any circumstances.
ALTERATIONS AND SPARE PART PROCUREMENT
Any alterations to the pump are only permitted in agreement with the manufacturer’s written consent. Only original spare
parts and authorised accessories are permitted. The use of unauthorised parts will immediately void warranty.
PERSONNEL QUALIFICATION
Only suitably qualied personnel may service this equipment. The operator must observe the local regulations for the
prevention of accidents. The operator is responsible for ensuring that all inspections and installation work are carried
out by authorised and qualied personnel only, having made themselves fully conversant with these instructions.
Work must only be carried out when the pump is switched o and at a complete stand still!!
GENERAL ELECTRICAL SAFETY
Before installation please check the following for safety reasons:
- Check power cords and electrical sockets for any damage and ensure they are in a ood free area
- The mains plug and any extension cords must be watertight, ensure any couplings are not lying on the ground
- Never carry the pump by its power cord or pull to power cord to unattach from the mains
- Install the pump in a safe, dry place where it is clear of harsh weather (continuous rain, ooding or humidity)
- Ensure the voltage indicated on the nameplate corresponds with the voltage on the electrical source
SAFETY
This instruction manual contains basic rules on safety which must be strictly adhered to. The installer and the operator must
carefully read these instructions prior to installation and commissioning. Please observe all of the safety directions, not only
under the main heading ‘Safety’ but each sub-heading also. Non-observance of safety reference may cause bodily harm to
persons or damage to the pump.
Failure to follow this safety reference could invalidate warranty and/or damage claims to pump!
Failure to follow this safety reference could cause death or severe physical injury!!
Keep pump equipment out of reach from children!!

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 7
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
The pump should be connected to a separate circuit breaker or fuse with a minimum carrying capacity of 10A. Please note that
if other appliances share an outlet, they may cause low voltage resulting in blown fuses, tripping of motor overload or burning
out of the motor. A permanent earthed connection to the pump is mandatory. ECO-MXA pumps come with an earthing
conductor and a grounding type attachment plug. Do not connect the pump to a power supply until permanently earthed.
For maximum safety, connect pump to a circuit equipped with a Residual Current Device (RCD).
ELECTRICAL CONNECTION
In order to ensure proper operation a static discharge head of 300mm is required; the discharge pipe must be installed
with a vertical rise of at least 300mm!
Frost damage will not be covered under warranty!
lt is the operator’s responsibility to take all preventative measures (e.g. provision of alarm systems, standby pump etc.)To avoid
consequential damages such as ooding due to pump failure.
300mm minimum of water above check valve
100mm minimum above bottom
Horizontal suction pipe length
Vertical suction pipe length
Drawing 2.0
SUCTION GUIDE
Incorrect size selection of pipes may result in pump damage that is not covered under warranty and may aect pump
performance!
2
4
6
2
4
6
8
10
Horizontal Suction Pipe Length (m)
1
8
7
5
3
32mm SP
40mm SP
12
14
16
18
20
22
24
26
9
Do not operate the pump
in these suction conditions
40mm SP
25mm SP
SP = Suction pipe
Chart 1.0
5 - 10m 32mm
10 - 25m 40mm
0 - 5m 25mm
Horizontal Suction Installation Only
Table 3.1
Horizontal Suction
Pipe Length (m)
Minimum Suction
Pipe Diameter (mm)
3 - 6m 32mm
6 - 8.5m 40mm
0 - 3m 25mm
Vertical Suction Installation Only
Vertical Suction Pipe
Length (m)
Minimum Suction
Pipe Diameter (mm)
Suction Pipe Section Chart
Table3.0

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
8
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
- Ensure correct suction pipe sizes - see Tables 3.0, 3.1 and Chart 1.0
- Ensure inlet and outlet pipes are correctly installed and tightened
- Release the top priming plug (found on the stainless steel pump body) by turning anti-clockwise 3/4 of a turn with a
14mm ring spanner. This will release air pressure allowing the pump to ll suciently (ensure that the water supply
has been turned on). Once air has released and water begins to spill, then fasten the priming plug
- Open main discharge valve
- Plug pump into main socket
- Run the highest and furthest valve/tap from the pump for 2 minutes (e.g. shower or garden tap on opposite side of
house)
- Close the discharge valve once excess air has evacuated the system
- Check for any leaks around the inlet/outlet pipes and the pump while the pump is still running
- Unplug the pump from main socket
- Check for any leaks around the inlet/outlet pipes and the pump when the pump is turned o
- If leaks are present, please tend to appropriately
- If no leaks are present, plug in pump to begin use of your ECO-MXA
Leaks of any size, large or small will cause the pump to cycle and not function correctly and may void the warranty!
INSTALLATION FOR FLOODED SUCTION
- Check to ensure that a sucient water level is available in the supply tank
- Ensure that the ECO-MXA is securely fastened to stop any vibration that may cause slow wear of the pump
- Ensure that the pump is unplugged
Non-return valve
- Electrical plug connections must be made in ood-safe locations and be protected from moisture
- Check available power supply
- Verify that the voltage and frequency of the ECO-MXA pump shown on the nameplate corresponds to those available
on the supply
- Observe local earthing requirements (do not cut o earth pin or use an adapter tting)
- Pumps must only be operated with electrical cables or extension leads up to a maximum of 10 metres
Do not use the pump if the power cord or plug are damaged. If damaged, please get these replaced by
qualied personnel!!
All electrical work to be carried out by a qualied and locally licensed electrician in strict conformity with
local regulations!
Drawing 3.0
- Ensure suction pipe has non-return valve (provided) tted to the discharge of the water supply,
or tted to the bottom end of the suction pipe.
- Ensure the non-return valve is installed in the correct direction

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 9
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
- Ensure correct suction pipe sizes - see Tables 3.0, 3.1 and Chart 1.0
- Ensure that suction pipe is completely lled with water
- Ensure inlet and outlet pipes are correctly installed and tightened
Only once pump has been lled it has a self-priming capacity. Please ensure that pump has been suciently lled as
dry-running causes damage to the pump!
INSTALLATION FOR LIFT SUCTION
Flood suction from tank above ground
Leaks of any size, large or small will cause the pump to cycle and not function correctly and may void the warranty!
- Ensure suction pipe has non-return valve (provided) tted to the discharge of the water supply,
or tted to the bottom end of the suction pipe
- Ensure the non-return valve is installed in the correct direction
- Open main discharge valve
- Plug pump into main socket
- Run the highest and furthest valve/tap from the pump for 2 minutes (e.g. shower or garden tap on opposite side of
house)
- Close the discharge valve once excess air has evacuated the system
- Check for any leaks around the inlet/outlet pipes and the pump while the pump is still running
- Unplug the pump from main socket
- Check for any leaks around the inlet/outlet pipes and the pump when the pump is turned o
- If leaks are present, please tend to appropriately
- If no leaks are present, plug in pump to begin use of your ECO-MXA
- Check to ensure that a sucient water level is available in the supply tank or bore
- Ensure that the ECO-MXA is securely fastened to stop any vibration that may cause slow wear of the pump
- Ensure that the pump is unplugged
Flood suction from tank above ground
Non-return valve
Recommended installation Not recommended installation
Non-return valve
Valve
Tee w/plug
Screen
Valve
Valve
Non-return valve
Drawing 4.0
Drawing 3.1 Drawing 3.2
- Remove top priming plug completely, ll pump body completely with water. This will take some time as it is a small
inlet and takes around 2L of water to ll the pump. Once full water will begin to spill over, fasten the priming plug
with a 14mm ring spanner

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
10
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
MAINTENANCE
Isolate from the power supply before checking the pump. Any damage to the connecting cable should only be
repaired by a qualied electrician!!
To ensure highest operational safety and reliability at lowest possible cost, the following routine checks are always
recommended at 6 month intervals:
- Check pump and pipe work for leaks
- Check non-return valve and screen (if installed) for debris
- Check pressure tank diaphragm pressure (if installed)
If there is danger of freezing, then it is necessary to completely drain the pump using the drain plug at the bottom of the pump
housing. For prolonged stand-down periods (e.g. winter shutdown) the pump needs thorough cleaning, complete draining
and dry storage. On re-commissioning check for free rotation by briey switching on the pump on. Then follow installation
procedures set out in this manual.
Any dry-running of the pump must be prevented as it will lead to failure of its internal pump parts!! (ECO-MXA Electronic
PRESSCONTROL version has built in run-dry protection)!!
Suction lift from tank below ground
Suction lift from bore/well Suction lift from stream
Flood suction from tank below ground
Recommended installation Not recommended installation
Recommended installation Recommended installation
Non-return valve
Valve
Tee w/plug
Screen
Valve valve
Non-return valve
Screen
Non-return valve
Screen
Non-return valve
Screen
Valve
Drawing 4.2
Drawing 4.1
Drawing 4.3
Drawing 4.4

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 11
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
OPTIONAL EXTRAS
The installation of a small 3L pressure tank after the pump and PRESSCONTROL in the system is recommended. This reduces
water hammer and pump start and stop cycle, increasing the operating life for your ECO-MXA and reducing start up wear.
By decreasing the pump’s start/stop cycling with a 3L expansion tank, this then helps to decrease the total power consumption
signicantly.
Thepressuretankshould beprechargedat aslightlylowervalue thanthe restart pressurecalibrationvalueof thePRESSCONTROL
device. The PRESSCONTROL is calibrated at 1.5 bar (22PSI), precharge the pressure tank at approximately 1.2 bar (18PSI).
Water hammer is a pressure surge or wave caused when a uid in motion is forced to stop or change direction suddenly. Water
hammer commonly occurs when a valve closes suddenly at an end of a pipeline system, and a pressure wave propagates in
the pipe. This pressure wave can cause major problems, from noise and vibration to pump failure, with the installation of the
pressure tank, the eects of the water hammer pulses can be removed.
For systems with minimal delivery demands, e.g. a glass of water, ice-making refrigerator, lter system, UV system
inverse, osmosis systems or old systems with small losses a 3L pressure tank is mandatory.
3Ltankmountedhorizontally 3L tank mounted vertically
3L PRESSURE TANK
3L Pressure Tank
System with Ceramic taps, solenoid mixing valve (these are tted in washing machines & dish washers etc) or copper
pipes must have a 3L pressure tank installed to absorb water hammer!
Valve closed - water is still
Valve open - water is moving
through the valve
ECO-MXA 404 ECO-MXA 404 with 3L
pressure tank installed
768kWh
per year
Up to
15%
reduction
Valve closes - water hammer
pressure wave produced
3L pressure tank installed -
spikes produced by valve
closure absorbed
WATER HAMMER
653kWh
per year
*Based on a family of four
Drawing 5.0 Drawing 5.1
3L PRESSURE TANK INSTALLATION

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
12
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
ECO-PURE FILTER HOUSING
ALL FILTER HOUSING KITS INCLUDE:
Appropriate lter, mounting brackets, screws and spanner
*10” Twin Filter Housing Unit also includes stainless steel faucet, hoses and tap
10" TWIN FILTER HOUSING KIT
10" JUMBO FILTER HOUSING KIT
25mm (1")
Brass Inserts
2x
10" FILTER HOUSING KIT
25mm (1")
Brass Inserts
20" JUMBO FILTER HOUSING KIT
3x
8 bar (116psi)
Max Working
Pressure
Type
10" Filter Housing
Max Working
Temperature Inlet/Outlet Size
45°C (113°F) 25mm (1")
8 bar (116psi) 45°C (113°F) 25mm (1")
8 bar (116psi) 45°C (113°F) 32mm (1 1/4")
8 bar (116psi) 45°C (113°F) 6.35mm (1/4")
10" Jumbo Filter Housing
20" Jumbo Filter Housing
10" Twin Filter Housing
WATER FILTRATION
Table 4.0

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 13
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
ECO-PURE FILTRATION CARTRIDGES
Provide high eciency ltration for the removal of sediment in water
supplies, removing sand, silt, dirt and rust particles.
Ideal for:
Mains drinking water
Rainwater
Dam water / Bore water
Pretreatment for UV treatment systems
ECO-PURE POLY SPUN
Available in 1micron, 5micron, 20micron and 50micron
Available in 20micron
Ideal for removal of sand, silt, dirt and rust particles from drinking
water. These elements have up to 7 times more holding capacity
than traditional rope wound elements. Suitable for repeated re-use
by simply washing in warm soapy water.
High ow rates improving water pressure and ow
Pre-treatment for poly spun elements and UV treatment systems
High dirt holding capacity lengthens cleaning intervals
ECO-PURE POLY PLEATED
Available in 5micron
Designed to remove unpleasant taste and odours as well as removing
ne sediment. This design makes it an excellent lter for removing
contaminants, to ultimately produce cleaner, clearer and simply better
tasting water.
Removes:
Bad Taste and Odour
Chlorine
Pesticides and agricultural sprays
Metals such as lead
ECO-PURE BLOCK ACTIVATED CARBON
FLOW RATE
* = 10 lpm at 1.5bar (22psi) with 20micron lter. Averaged lpm of the 3-6 month life span.
10 " Standard
Poly Spun
(lpm)
Flow Rate
Capacity
Type Poly Pleated
(lpm) Block activated
carbon (lpm)
10 " Jumbo
20 " Jumbo
4 x
8 x
16 x
40 50
80
160
100
200
20
35
50
Table 5.0

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
14
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
ELECTRONIC PRESSCONTROL PC-1100
TECHNICAL DATA
PRESSCONTROL is a device that guarantees optimal control of pumps for domestic use. Deriving from
a hydraulic and electronic logics project for the Australian and New Zealand market, it is capable of
simultaneously detecting both the pressure and the ow, as well as automatically managing the pump
operation. It replaces the traditional pressure controller and pressure tank, protecting the pump in the
case of water shortages. PRESSCONTROL:
- Starts and stops the pump in accordance with the opening and closing of the taps
- Maintains constant pressure during delivery
- Stops the pump in the case of water shortage, protecting it from dry running
- Maintenance-free
5°C - 40°CWater temperature range min / max
Ambient temperature
Max. working pressure
Inlet/outlet pipe connection
Max particle size
Electrical supply
0°C - 50°C
10 bar
25 mm BSP / 1” Inch BSP
1 mm (non-abrasive material)
220V - 240V, 50 Hz
Table 6.0
PRODUCT DESCRIPTION
Power on
Pump on
Failure
Restart
Power
Inlet
ELECTRIC MOTORS AND PUMPS
UNIT STARTING AND WORKING
INTEGRATED
INTELLIGENCE
INTEGRATED
INTELLIGENCE
Electrical connection AS/NZ plug tted to 1.5m lead
Max current 10 A
Software version 4.0
Start pressure 1.5 bar

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 15
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
When the unit is connected to the electrical network, the green LED “Power On” lights up and the yellow LED “Pump On”
indicates that the pump is in operation. The pump continues to operate for up to 5 seconds enabling the system to ll the
pipes and to reach the required pressure. If this is insucient, the red LED “Failure” lights up. In this event, keep the “Restart”
button pressed and wait with a tap open until the red LED “Failure” light is o. Once the button is released and the tap is
closed, the unit stops the pump is at it’s maximum pressure.
STARTING
FUNCTIONING
If the column of water between the pump and
the highest tap exceeds 15m, the unit cannot be
installed directly on the pump. The
PRESSCONTROL has to be raised until the
column of water between the unit and the
highest tap does not exceed 15m
It is advisable to connect the
unit outlet to the system by
means of a exible hose
Safety valve preventing
water emission in case of
diaphragm breaks
DO NOT TOUCH!
It is imperative to
install the unit with
the arrows in the
upward position
The unit can be installed
directly on the pump or
between the pump and the
rst tap
The unit is equipped with a
non-return valve to prevent the
pipeline from losing pressure
No taps can be installed between
the pump and the unit
The unit is pre-set by the
manufacturer at the restarting
pressure of 1.5bar (22psi). The
pressure produced by the pump
must be 0.8bar (12psi) higher than
the preset pressure
INSTRUCTIONS FOR CORRECT UNIT INSTALLATION
When starting operation is achieved, the unit is programmed to perform all the pump control operations automatically. When
particular operational breakdowns occur, such as water failure, obstruction of the suction pipe etc, the unit recognises the
breakdown and the red LED “Failure”lights up. At the same time a stop signal is sent to the pump to prevent damages caused
by it’s working in the absence of water. Rectication of the failures that have caused the blockage, allows the system to be
restarted manually by pressing the “Restart” button.

SPARE PARTS
ECO-MXA 404 STAINLESS STEEL SELF-PRIMING JET PUMP
Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
16
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
NOTE: When ordering any spare parts, please state all nameplate data.
No. Name
1 Dust cap
2 Hexagonal screw M6x20
3 Pump casing
4 O-ring d11.2x2.4
5 Plug
6 O-Ring d111.4x1.8
7 O-Ring d152x4
8 Self chuck assembly
9 Hexagonal nut M10
10 Spring washer Φ10
11 Washer Φ10
12 Guide vane cover
13 Impeller 50Hz Φ98xΦ37.7x5
No. Name
32 Serrated lock washer external teeth Φ4
33 Washer Φ4
34 Hexagonal nut M4
35 Cross recessed pan head tapping screws ST3.5x12
36 Capacitor 220V 30uF
37 Cable gland
38 O-Ring d120x2.0
39 Wiring diagram
40 The junction box
41 Cross recessed pan head tapping screws ST3.5x16
42 Nable gland
43 Cross recessed pan head screws M5x10
14 Primary guide vanes components
15 Middle section
16 Diuser
17 Washer Φ30x14.2x1.5
18 Mechanical seal
19 Pump cover
20 Slinger
21 Front cover
22 Hexagonal nut M6
23 Bearing 6203-2RS
24 Rotor
25 Bearing 6202-2RS
26 Stator
27 Motor house
28 Terminal box pad
29 Junction box
30 Cross recessed countersunk head screw with pad
M4x8
31 Connection pole
44 Spring washer Φ5
45 Washer Φ5
46 Cross recessed pan head tapping screws ST3.5x16
47 Cable gland
48 Junction box nut plug
49 Junction box nut
50 Cable
51 Three wave ring D35
52 Back cover
53 Hexangular stud bolt M5x142
54 Fan
55 Fix ring
56 Fan cover
57 Bolt and washer assembly screws M4x8
58 Silent blonk
59 Base frame
60 Washer Φ6
61 Spring washer Φ6
62 Hexagonal screw M6x20

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 17
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
NOTE: When ordering any spare parts, please state all nameplate data.
No. Name
1 Dust cap
2 Hexagonal screw M6x20
3 Pump casing
4 O-ring d11.2x2.4
5 Plug
6 O-Ring d111.4x1.8
7 O-Ring d152x4
8 Self chuck assembly
9 Hexagonal nut M10
10 Spring washer Φ10
11 Washer Φ10
12 Guide vane cover
13 50Hz Φ98xΦ37.7x5
No. Name
32 Connection pole
33 Serrated lock washer external teeth Φ4
34 Washer Φ4
35 Hexagonal nut M4
36 Cross recessed pan head tapping screws ST3.5x12
37 Capacitor 40uF
38 Cable gland
39 Wiring diagram
40 The junction box
41 Cross recessed pan head tapping screws ST3.5x16
42 Nable gland
43 Cross recessed pan head screws M5x10
14 Primary guide vanes components
15 Middle section
16 Diuser
17 Washer Φ30x14.2x1.5
18 Mechanical seal
19 Pump cover
20 Slinger
21 Front cover
22 Hexagonal nut M6
23 Bearing 6203-2RS
24 Rotor
25 Bearing 6203-2RS
26 Stator
27 Motor house
28 Terminal box pad
29 Junction box
30 Cross recessed countersunk head screw with pad
M4x8
31 O-Ring d135x2.4
44 Spring washer Φ5
45 Washer Φ5
46 Cross recessed pan head tapping screws ST3.5x16
47 Cable gland
48 Junction box nut plug
49 Junction box nut
50 Cable
51 Three wave ring D40
52 Back cover
53 Hexangular stud bolt M5x160
54 Fan
55 Fix ring
56 Fan cover
57 Bolt and washer assembly screws M4x8
58 Shock pad
59 Base frame
60 Washer Φ6
61 Spring washer Φ6
62 Hexagonal screw M6x20
SPARE PARTS
ECO-MXA 405 STAINLESS STEEL SELF-PRIMING JET PUMP

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication.
18
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
NOTES

Every care has been taken to ensure the accuracy of the information contained in this publication, but due to continuous development and improvement the right is reserved to supply products
which may dier slightly from those illustrated and described in this publication. 19
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
Faults Causes Solutions
Pump does not
run
Interruption of the power supply,
short circuit or an insulation fault in
the motor coil
Check power supply
Call an expert to check the pump unit
Pump runs,
but little or no
delivery
Pump or pipes are blocked due to
foreign matters
Lack of supply water
Primed incorrectly
Air in suction pipes
Check all lters/check valve for foreign matters
Ensure all taps are turned on
Repeat priming procedure (refer to page 8 for ooded suction or
page 9 for lift suction) to remove any air from the system
Check the tightness of the whole pipe up until the pump and
tighten it
Motor overheats Low voltage
Ambient temperature above +40 °C
or insucient ventilation
Ensure power supply is not running on an extended cable
exceeding 10m. Check voltage on terminals of the motor. It should
be within ± 10 % of 230V (this should be carried out only by
qualied personnel)
Relocate pump to a cooler, better ventilated environment
The ow is too
little
Length of pipe is excessive and
diameter is too small
Excessive head
Decrease pipe length and increase pipe size (diameter)
Decrease head on pump
Pump vibrates
Fuse blows or
circuit breaker
trips when pump
starts
Controller failure
light
Incorrectly mounted/xed
Pump jammed.
Motor stator may be defective,
circuit leakage or insulation failure.
Fuse size or circuit breaker may be
too small
Loss of prime or no water in tank
Electronic controller faulty, maybe
damaged by power surge or spike
Ensure pump is fastened to a solid surface by two mounting
screws
Get pump serviced
Check pump is primed and water supply is sucient
Replace controller
FAULTS, CAUSES AND SOLUTIONS

www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
www.ceg.co
20
New Zealand Australia Fiji
CEGEMXAMANNZ_14092016
CODE OF COMPLIANCE
PRODUCT CONFORMITY CERTIFICATE
ECO-MXA 404
ECO-MXA 405
We CEG New Zealand Ltd and CEG Group PTY Ltd declare under our sole responsibility that the product is
in conformity with the listed standard or other normative documents.
Inspector:
Keith Norling (Director)
Inspector:
Tyrone Norling (Director)
Certicate Holder:
CEG New Zealand Ltd, 76-86 Cuba Street, Palmerston North 4410, New Zealand
CEG Group PTY Ltd, Unit 2, 711 Boundary Road, Coopers Plains, 4108, Queensland, Australia
ELECTRIC MOTORS AND PUMPS
PRODUCT TYPE
This product has been tested to relevant standard and found compliant with specication:
CEG AS/NZ Issue F0054 version A
✓
This Certicate provides a legally recognizable statement that the products listed below or any genuine
spare parts are safe to use for their intended design purpose.
REFERENCE/CERTIFICATE ID NO: CEG5400
Dated: 01/01/2016
QUALITY
ASSURED
CUSTOMER COPY - THIS IS AN IMPORTANT DOCUMENT
AND SHOULD BE RETAINED FOR A MINIMUM OF 7 YEARS
Model
Date of Purchase
Serial Number
Invoice Number
/ /
For ease of service in the future please ll in below:
SERVICE REFERENCE INFORMATION
info@ceg.co www.ceg.co
This manual suits for next models
1
Table of contents
Other CEG Water Pump manuals
Popular Water Pump manuals by other brands

Giant
Giant P400-5100 Series Operating instructions/ repair and service manual

IPM
IPM OP Series Operation manual

SKF
SKF Centro-Matic P653S User and maintenance instructions

EasyPro
EasyPro PCA75 Installation and service manual

Dover
Dover PSG All-Flo A075-NAA-VVYV-A30 Installation operation & maintenance data

BJM Pumps
BJM Pumps FAHRENHEIT S-F Seires Installation, operation & maintenance manual