Cellini CMF100 User manual

MODEL NO.: CMF100
ULTRASONIC MIST FAN
WITH IONIZER
FEATURES
Remote Controller Unit
Front View Back View
Top Panel
1. Timer ON Indicator
2. Ionizer ON Indicator
3. Misting ON Indicator
4. Fan Oscillation Indicator
5. Fan Low Speed Indicator
6. Fan Medium Speed Indicator
7. Fan High Speed Indicator
8. Power ON Indicator
9. Timer Button
10. Ionizer Button
11. Misting ON/OFF Button
12. Timer & Temperature Display
13. Fan Oscillation Button
14. Fan Speed Button
15. Fan Power ON/OFF Button
16. Remote Controller Sensor
17. Misting Outlet
18. Misting Volume Control
19. Water Level Indicator
20. Wheel
21. Drain Plug
22. Rotary Fan Grill
23. Handle
24. Detachable Water Tank
25. Remote Control Power ON/OFF Button
26. Remote Control Fan Oscillation Button
27. Remote Control Misting ON/OFF Button
28. Remote Control Timer Button
29. Remote Control Fan Speed Button
30. Remote Control Ionizer On Button
31. Remote Control Battery Flap
32. Wrench
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the
user to the presence of uninsulated. "Dangerous Voltage" within the product's enclosure that may
be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence
of important operating and maintenance (servicing) instructions in the literature accompanying
the appliance.
WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE
WARNING:
A. To avoid an electrical shock, please do not open the rear cabinet
for repair or cleaning unless qualified person.
B. If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person
in order to avoid a hazard.
C. The appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience andd knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
D. Children should be supervised to ensure that they do not play
with the appliance.
This marking indicates that this product should
not be disposed with other household wastes
throughout the EU. To prevent possible harm to
the environment or human health from
uncontrolled waste disposal, recycle it responsibly
to promote the sustainable reuse of material
resources. To return your used device, please use the return
and collection systems or contact the retailer where the
product was purchased. They can take this product for
environmental safe recycling.

PRODUCT INTRODUCTION
The ultrasonic mist fan is designed with digital control
system. It has device for storing water. It can lower
surrounding temperature, freshen the air with equipped
ion humidify the air through the principle of water misting.
LED panel makes it easy to use.
IMPORTANT NOTES
Please read the instruction manual carefully before
operating this unit.
1. Make sure that the home power supply is consistent
with the product before plug in.
2. Switch off and disconnect from the power outlet
when not in use or before cleaning.
3. Do not expose the unit to rain and keep out of reach
of water on the control panel or LED for proper use.
4. Do not put the fingers or any objects inside the fan
grill during operation.
5. Do not operate the unit if there is any damage to the
power plug or cord - take the unit to an authorized
service agent for replacement; do not attempt to
undertake any required repairs yourself.
6. Wipe clean with damp cloth only - do not use any
abrasive cleaners.
7. This appliance is not intended for use by persons
(including children) with reduced physical, sensory,
or mental capabilities or lack of experience and
knowledge unless then have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
8. Do not use the misting function if the unit is to be
used in a damp place.
9. Do not use the misting mode when water tank is
empty; water level in must be above minimum level
for this function to operate, otherwise it may cause
water pump malfunction.
10.If the unit is being stored away for a long period of
time without use, empty the water tank before storing
or transporting the unit.
HOW TO ASSEMBLE THE WHEELS (SEE DRAWING 1)
1. Attach the four wheels to the base of the unit using
the included wrench (Feature No.32), tightening
each wheel in a clockwise direction.
2. Wheels can be
locked in position
if required.
WATER REFILL
1. Ensure the unit is placed on a level surface and
unplug from the power and switch off all the function
when refilling water.
2. Remove the water tank (Feature No. 24), fill water
tank to above minimum level indicator, but ensure
water is not overflowed.
3. Do not fill water above the Max water level mark
and misting function will not operate effectively if
water level is below minimum level.
MISTING FAN OPERATION - REMOTE & CONTROL PANEL
Make sure that the home power supply is consistent
with the product before plug in.
POWER ON/OFF OPERATION
Press the "fan power ON/OFF button"(Feature No. 15)
on the control panel or (Feature No.25) on the remote
controller to start operation, LED light (Feature No.8)
will become illuminated on the control panel. Press
the same button to turn off the function.
FAN SPEED OPERATION
Select the required fan speed to Low/Medium/High
by press the "Fan Speed Button"(Feature No.14) on
the control panel or (Feature No. 29) on the remote
control. LED light above selected speed will become
illuminated on the control panel.
OSCILLATION OPERATION
To start 360° air flow direction, press the "Fan
Oscillation Button" (Feature No. 13) on the control
panel or (Feature No. 26) on the remote controller once;
LED light(Feature No.4) will become illuminated on the
control panel, and the rotary fan grill will begin to rotate,
directing air in a full circle. Press the same button to
turn off the function.
1. Remove the
water tank and
fill clean water.
2. Tight the cover
in clockwise
direction.
4. Put the water tank
back to the unit.
5. Press the “Fan
power ON/OFF”
button.
6. Select the Fan
Speed to start.
7. Press the“Misting
ON/OFF” to start
misting.
8. Adjust the mist density
by turning the “Misting
volume control”.
3. Turn the water
tank upside
down to make
sure no leaking.
Warning :
1. It may take a minute for a new Misting Fan to start
misting, it is normal for air to come out of the nozzles
before water and the mist.
2. Low Water Level Alarm : when water under lower
lever, you will hear the “beep” sound and the “Mist
Indicator” will flash continuously. At the same time
the power of the pump inside the unit will be cut off
to protect the life of the pump. To stop the alarm,
turn off the unit from the power outlet. Fill the tank
with water above the min.
level and turn on the unit
again.
3. Direct pull water into Misting
Fan is prohibited.
(SEE DRAWING 2)
REMOTE CONTROLLER
1. Open the remote control battery flap (Feature No.
31) and insert 2 pieces 1.5V "AAA" size of dry battery.
2. Remote controller must be aimed at the sensor
(Feature No. 16) on the front of the appliance,
distance within 5 meters, and will not function
from beside or behind the appliance.
CLEANING AND MAINTENANCE (SEE DRAWING 3)
1. Ensure the unit is switched off and disconnected
from a power source before cleaning.
2. Clean outer casing or control panel with a damp
cloth only - do not use any abrasive cleaners or
harsh chemicals, and ensure the control panel or
LED is out of reach of water.
3. Check the condition of misting and water tank before
every use.
4. After long time operation with this appliance, the
unit may become clogged with dust and dirt, which
will greatly affect the performance of the unit.
Sometimes mold and mildew may also occur due
to the water tank not regular cleaned, recommend
to clean once every two weeks.
5. Remove the drain plug (Feature No. 21) and allow
the water tank to empty.
6. If the unit is being stored away for a long period
of time without use, empty the water tank before
storing or transporting the unit.
TECHNICAL SPECIFICATIONS
Input Voltage ............................ 220-240V 50/60Hz
Input Power..................................................100W
Operating Temperature.............................. 0ºC-45ºC
Operating Humidity ........................ Lower than 90%
Fan Maximum Air Volume .................. > 300M3/Hour
Fan Maximum Speed................................... 5.5m/s
Motor Speed...High 1400/Med. 1340/Low 1220RPM
Water Tank Capacity ................................... 4 Liters
Evaporative Contant Of Wate .........Approx 300mL/Hz
Ion Density Approx........................... 3x106 Ion/cm3
Timer Control.......................................... 1-8 Hours
Remote Controller Battery .............(AAA) 1.5V × 2pcs
Remote Control Distance................................... 5 m
Dimensions.................... Approx 41 × 23.5 × 81cm
N.W ................................................Approx 5.75kg
DRAWING 3
DRAWING 2
DRAWING 1
MIN MAX
IONIZER OPERATION
Press the "Ionizer Button" (Feature No. 10) on the control
panel or (Feature No. 30) on the remote controller once
to release the anions. Illuminated light is on the control
panel will indicate function is currently in operation.
Press the same button to turn the function off.
TIMER OPERATION
1. Press the "Timer Button" (Feature No. 9) on the
control panel or (Feature No. 28) on the remote
controller to set the countdown timer. The unit will
operate with its present settings until the timer
counts down.
2. Timer can be set from 1 to 8 hours.
3. Once set, LED display will show the time set.
4. To switch off the timer function and operate the
unit continuously, press the timer button until LED
display switches off and the LED light on the control
panel above timer button LED will also be off.

31
29
30
28
26
27
25
超聲波冷霧電風扇
帶離子空氣淨化功能
產品型號: CMF100
使用說明書
功能及名稱簡介 (圖解)
1. 定時顯示燈
2. 離子顯示燈
3. 冷霧顯示燈
4. 導風網轉動顯示燈
5. 風扇低速顯示燈
6. 風扇中速顯示燈
7. 風扇高速顯示燈
8. 電源顯示燈
9. 定時選擇鍵
10. 離子開關
11. 冷霧開關
12. 定時時間及溫度顯示器
13. 導風網轉動開關
14. 風速選擇鍵
15. 電源開關
16. 遙控接收器
17. 霧化器
18. 強弱霧化調節器
19. 水位指示
20. 旋轉滑輪
21. 排水塞
22. 導風網
23. 手柄
24. 水箱
25. 電源遙控
26. 風向遙控
27. 霧化遙控
28. 定時遙控
29. 風速遙控
30. 離子遙控
31. 遙控器電池蓋
32. 扳手
遙控器
控制面板
正面
底部
背面
注意: 為減少觸電危險, 切勿把產品暴露於雨中或潮濕環境中, 亦不要拆去後部
零件
。機身內並無使用者維修的零件, 請將維修工作委托給專業資格人員
。
三角型內有箭頭的閃電符號旨在提醒使用者, 本產品機殼內有未經絕緣的
“危險電壓”其幅度足使人觸電而發生危險!
三角型內加感嘆號旨在提醒用戶, 有重要的操作與保養說明配合本機, 請仔細閱讀
後方可使用!

IB3218A07
產品特點及適用範圍
1. 新概念風扇,移動方便,外型美觀;
2. 長壽命低操音電機,節省用電;
3. 兼具送風、淨化空氣、加濕等功能於一
體;
4. 旋轉式導風網,加大吹風面積;
5. 離子空氣淨化器、除塵、除臭, 有效阻
擋細菌;
6. 超聲波霧化器,提高加濕空氣和降溫功
效;
7. 輕觸式按鍵、功能顯示燈及溫度顯示;
8. 適用於家庭使用。
注意事項:
1. 在使用前,必須詳細閱讀此說明書,方
可開始接上電源;
2. 本產品的電源性質只能使用220-240V
50-60Hz;
3. 長時間不使用時,插頭電源線應從插座
中拔出;
4. 給水箱注水時,應使用的成分純度高、
細菌少的清水。水箱中的水要經常添
加,使其保持在安全水位,更要定期進
行更換和清洗水箱;
5. 清潔外殼污垢時,請用蘸有稀釋中性洗
滌劑的布輕輕擦去污垢,然後再用乾布
仔細擦拭,直至光潔。
安裝:
1. 打開包裝,取出電風扇,按(圖示一)
所示裝上旋轉滑輪,並上緊固定螺絲;
2. 風扇應放置於疏風
通暢及較水平的地
方,使用時不得傾
斜。
產品特點及適用範圍
1. 新概念風扇,移動方便,外型美觀;
2. 長壽命低操音電機,節省用電;
3. 兼具送風、淨化空氣、加濕等功能於一
體;
4. 旋轉式導風網,加大吹風面積;
5. 離子空氣淨化器、除塵、除臭, 有效阻
擋細菌;
6. 超聲波霧化器,提高加濕空氣和降溫功
效;
7. 輕觸式按鍵、功能顯示燈及溫度顯示;
8. 適用於家庭使用。
注意事項:
1. 在使用前,必須詳細閱讀此說明書,方
可開始接上電源;
2. 本產品的電源性質只能使用220-240V
50-60Hz;
3. 長時間不使用時,插頭電源線應從插座
中拔出;
4. 給水箱注水時,應使用的成分純度高、
細菌少的清水。水箱中的水要經常添
加,使其保持在安全水位,更要定期進
行更換和清洗水箱;
5. 清潔外殼污垢時,請用蘸有稀釋中性洗
滌劑的布輕輕擦去污垢,然後再用乾布
仔細擦拭,直至光潔。
安裝:
1. 打開包裝,取出電風扇,按(圖示一)
所示裝上旋轉滑輪,並上緊固定螺絲;
2. 風扇應放置於疏風
通暢及較水平的地
方,使用時不得傾
斜。
(圖示一)
(圖示二)
(圖示三)
1 2 3
8
4
3. 按風速選擇鍵(圖解14)可以選擇風速,
風速分高、中、低三檔, 同時風速指示
燈作相應風速顯示。
4. 按導風網轉動開關(圖解13),風網轉動,
導風網轉動顯示燈(圖解4)亮,再按一次
停止。
負離子操作
按離子開關(圖解10)將釋放負離子,同時
負離子燈(圖解2)亮起。
預設時間操作
按定時鍵(圖解9)開啟定時功能,定時顯示
燈亮起,可任意選擇1-8小時定時設置,
時間顯示器顯示定時,連續按此鍵,可調
整定時時間,(圖解1)當調整到8小時,按
此鍵可關閉定時功能。
霧化操作功能
4. 使用一段長時間之後,本產品可能會佈
滿灰塵和污垢,這將大大影響產品的性
能,建議每兩個星期清洗一次。
6. 如需存儲此產品一段長時間不使用,請
先清空水箱。
主要技術參數:
1. 電源電壓:
220-240V 50-60Hz
2. 額定輸入功率:
100W
3. 使用環境溫度:
0℃
至
45℃
;
4. 使用周圍空氣相對濕度:小於
90%
5. 風流量:快速
>300M3/Hr
6. 風速:5.5m/s
7. 馬達轉速: 快速
1400RPM/
中速
1340 RPM/
慢速
1220 RPM
8. 水箱裝水量:4L
9. 噴霧量(水蒸發量):約
300ML/Hr
10.
離子密度:
3 x106 lon/cm3
11.
定時器控制:1-8小時
12.
遙控器電池:
(AAA) 1.5V x 2pcs
13.
遙控器遙控距離:
>5
米
14.
外形尺寸:約
41 x 23.5 x 81cm
15.
淨重:約
5.75kg
注意:
● 如果電源線損壞,為避免危險,必須由
製造廠或其維修部或類似的專職人員來
更換。
● 本產品不預備給體能弱、反應遲緩或有
精神障礙的人(包括兒童)使用,除非
在對其負有安全責任的人員的指導或幫
助下安全使用;
● 兒童應被監督,以保證他們不玩耍此產
品。
遙控操作
本機也可通過遙控操作,遙控器按鍵與控
制面板相同 。
1, 打開遙控器背部電池蓋裝上兩粒AAA
1.5V乾電池即可使用。
2. 使用遙控器時應對準風扇遙控接收器
(圖解16),有效遙控距離為5米。
保養與清潔(圖示三)
1. 請確保機組已關閉並關閉電源才可進行
清洗,以免發生危險。
2. 按(圖示4)所示拆開排水塞(圖解21)可清
放內部清水。
3. 清潔外殼或控制面板時只需用濕布,不
要使用任何具有研磨作用的清潔劑或刺
激性化學品。
3. 每次使用前請檢查冷霧及水箱的狀態。
弱強
警告 :
1. 初次啟動時,由於要先排出噴霧喉管內
的空氣,噴霧將稍後片刻才能開始運作。
2. 注意缺水保護:當水箱缺水時,蜂嗚器
發出報聲響,且噴霧顯示燈閃爍,水泵
自動停止工作,加水後重新開啟可恢復
操作。
3. 切勿將水直接注入風扇機殼內,會造成
噴霧不良。(圖示二)
風扇操作功能
1. 接通電源,顯示燈(圖解8)亮,蜂嗚器
響一聲,風扇處於待機狀態。
2. 按電源開關(圖解15)開啟風扇,初次開
啟設定為風扇低速,顯示器(圖解12)顯
示當前溫度。
先抽出
水箱加水
裝滿後扭緊水箱蓋
倒轉水箱,蓋向下測試
是否已扭緊不會漏水
將水箱放回機身
開啟電源開關
5 6 7
再按風速選擇鍵
開啟風扇
按噴霧開關
啟動噴霧
調節霧化強弱
Other Cellini Fan manuals
Popular Fan manuals by other brands

dyras
dyras TF-40 instruction manual

Home Decorators Collection
Home Decorators Collection WESLEY 34776-HBUG Use and care guide

Midea
Midea FG18-19ER manual

Helios
Helios KWL EC 700 D Pro / WW Installation and operating instructions

Thermador
Thermador HMWN30 installation manual

Progress Lighting
Progress Lighting AirPro P250009 installation manual

Venmar
Venmar HRV CONSTRUCTO 2.0ES User's and installer's manual

Hinkley
Hinkley 980030 installation instructions

BALMUDA
BALMUDA GreenFan EGF-1400 Series instruction manual

emerio
emerio FN-123103 instruction manual

Hunter
Hunter 23970 Parts guide

Hunter Pacific
Hunter Pacific POLAR DC P3B2571 Installation & user manual