CEM AI-321 User manual

Face Recognition Temperature Monitor
User's manual
Please read this manual before switching the unit on.
Important safety information inside.

1
Face Recognition Temperature Monitor user's manual
Contents Page
1. Product Appearance ................................................................... 3
2. Interface Instruction ................................................................... 4
3. Wiring Instruction ....................................................................... 5
4. Technical Specications ............................................................. 6
5. Access Control & Attendance for Company............................ 7
6. Access Control & Attendance for School................................. 7
7. Quick Temperature Check.......................................................... 8
8. Install Instruction ........................................................................ 9

32
Face Recognition Temperature Monitor user's manual Face Recognition Temperature Monitor user's manual
Biometric products cannot be 100% suitable for any anti-counterfeiting environment.
High security level places, please use combination authentication.
Do not touch the temperature probe with your ngers or blow the probe.
Please make sure no hair, sweat, or hat cover your forehead before measuring
temperature.
If the forehead is cold, wait for the forehead to become warm before taking the
temperature measurement. Such as: after washing the face, after applying ice, after
entering the room from the outside in winter.
1. Product Appearance
Color Camera
Temperature Probe
White Fill Light
Infrared Fill Light
Infrared Camera
LCD Screen
The Face Recognition Temperature Monitor eectively combines traditional infrared
temperature measurement with AI face recognition. It only requires the user to
stand in front of the device to quickly complete user identication and temperature
measurement. Once the temperature exceeds the normal value, it will alarm and
prohibit passage. In order to be suitable for more scenarios, this device supports 3
usage modes, and is equipped with different platform software for more powerful
functions.
1. Access Control & Attendance for Company | Equipped with Attendance & Access
Control Management Platform Software for Company.
2. Access Control & Attendance for School | Equipped with Attendance & Access
Control Management Platform for School.
3. Quick Temperature Check | Equipped with Temperature Cloud APP to monitor
abnormal data and snapshot. (Only temperature detection for scenes that do not
require face recognition)
Notice:
During installation and use, all electrical safety regulations of the country and the
region of use must be strictly observed.
When wiring, disassembling and other operations, please be sure to disconnect the
power supply, do not operate with electricity.
If the device emits smoke, produces unusual odors, or makes noises, immediately
turn o the power and unplug it, and contact the dealer or service center in time.
If the equipment is not working properly, please contact customer service, do
not disassemble or modify the equipment in any way. (The company does not
assume any responsibility for problems caused by unauthorized modification or
maintenance)
Do not drop objects on the device or vibrate the device vigorously to keep the device
away from magnetic interference.
Avoid installing the device where the surface vibrates or is vulnerable to shock.
Avoid installing the device at the air outlet of the air conditioner or in a place with
large airow uctuations.
Try to ensure that the equipment is installed vertically.
Please do not use the device in high temperature, low temperature or high humidity
environment.
Please do not aim the lens of the device at strong light objects such as the sun,
incandescent lamp, etc., otherwise it will cause lens damage.
Avoid placing the device in direct sunlight, poorly ventilated locations, or heat source
accessories such as heaters or heaters.

54
Face Recognition Temperature Monitor user's manual Face Recognition Temperature Monitor user's manual
3. 7PIN 12V Power Supply, Relay Interface
1234567
COM NO NC GND GND 12V 12V
4. Ethernet port
5. 2PIN 485 Interface
6. Tamper key
7. Micro USB Port
8. USB-A Port
9. 12V Power Adapter Socket
1 2
485A 485B
3. Wiring Instruction
Microphone
Screw holes for hanging board
Reset Button
1
2
3
4
5
6
7
8
9
Speaker
2. Interface Instruction
1. 6PIN Door Button, Door Sensor, Alarm Interface
2. 11PIN Reserved IO
1 2 3 4 5 6
5V GND NC Door Button Door Sensor Alarm
1 2 3 4 5 6 7 8 9 10 11
PWRON IO7 GND 3.3V IO6 IO5 IO4 IO3 IO2 IO1

76
Face Recognition Temperature Monitor user's manual Face Recognition Temperature Monitor user's manual
Autoranging Digital Multimeter / EnglishAutoranging Digital Multimeter / English
Smart functions
Face recognition capacity 50000 people
Oine record 100000
Recongition accuracy 99.83%
Face liveness detection Support binocular near infrared live detection
Face recognition speed 1080P @ 25fps, support face detection tracking,
optimization
Face liveness detection
speed About 200ms
Occlusion adaptation About 400ms
Basic parameters
Screen size 7 inch
Product size 268*135*45 (length*width*height)
Operation humidity 10%~90%
Operation temperature 10~40oC/ 50~140oF
5. Access Control & Attendance for Company
At this mode, User need to login to the Attendance & Access Control Management
Platform Software for Company to add the device ID, import employees’ information
and their face photos and congure this device as an attendance device for employees.
After the conguration is complete, the user can use the device to synchronize data.
After synchronization is complete, face recognition/temperature measurement/access
control/attendance can be started.
For detailed instructions, please refer to the guidance of the Face Recognition
Temperature Monitor and the instructions of the Attendance & Access Control
Management Platform Software for Company.
6. Access Control & Attendance for School
At this mode, User need to login to the Attendance & Access Control Management
Platform Software for School to add the device ID, import students and teachers’
information and their face photos and congure this device as an attendance device for
them. After the conguration is complete, the user can use the device to synchronize
data. After synchronization is complete, face recognition/temperature measurement/
access control/attendance can be started.
For detailed instructions, please refer to the guidance of the Face Recognition
Temperature Monitor and the instructions of the Attendance & Access Control
Management Platform Software for School.
Temperature measurement module parameters
Measuring range 32oC~45oC/ 89.6oF~113oF
Measurement accuracy ±0.5oC/ ±0.9oF
Measuring diatance 20~50cm
Measure time 0.5s
System hardware parameters
Processor 4-core A7
Operating system Android 8.1
Memory size 1GB LPDDR3
Storage size 16G EMMC
Cameera Parameters
Resolution Color 200W (1920*1080) Infrared 130W (1280*960)
Imaging device Color AR0230 Infrared AR0130
Lens 2.9mm
Recognize height 1m~2m
Recognition distance 0.3m~1.2m
Angle of view Horizontal: 89oVertical: 57oDiagonal: 98o
Face angle ±30o
Minimum illumination Color ≥0.01LUX at F1.2, Infrared:≥0.01LUX at F1.2
signal to noise ratio Color ≥4dB, Infrared:≥44dB
Wide dynamic range Color ≥105dB, Infrared:≥83.5dB
Interface parameters
Network interface 1 RJ45 10M/ 100M adaptive Ethernet port
USB interface 1 USB interface
Wireless connection WiFi+BLE4.0
RS485 interface 1 RS485 interface
Relay interface 1 relay interface
Fire alarm door check
button 1 re alarm door check button
IO reserved 1 11pin terminal
Power supply DC12V/ 3A
4. Technical Specications

98
Face Recognition Temperature Monitor user's manual Face Recognition Temperature Monitor user's manual
8. Install Instruction
Box 86 for Wall-Mounted Installation
1. Install stickers on the wall, and make holes in the wall according to the height and
position of the stickers to install Box 86.
2. Align the outlet of the hanging board with the center of the Box 86,punch four
mounting holes on the wall according to the punching size diagram,and insert four
wall plugs.
3. Use four KA 4*25 screwsto fix the hanging board to the wall. Connect the cable of
the external device to the cable, arrange the cables,and determine the cable outlet
method.
4. Hook the device from top to bottom on the mounting plate,and make sure that the
upper part of the hanging plate is inserted into the groove on the back of the device.
5. Fix the device and the hanging plate from the bottom with a screw.
7. Quick Temperature Check
At this mode, fast temperature detection and automatic recording of data and face
photos can be performed. User need to download the Temperature Cloud APP to add
the device ID. Scan the QR code as follow to download the APP.
Temperature Cloud APP
Scan the QR code as follow to get the guidance of the Face Recognition Temperature
Monitor and the instructions of the Attendance & Access Control Management
Platform Software.

1110
Face Recognition Temperature Monitor user's manual Face Recognition Temperature Monitor user's manual
Wall-Mounted Installation
1. Attach an installation sticker to the wall, make holes in the wall according to the
height and position of the sticker, insert a wall plug, and install 4 hex screws.
2. Fix the hanging board on the wall with four KM 4* 10 screws.
3. Hook the device from top to bottom on the hanging board, and make sure that the
upper part of the hanging board is inserted into the groove on the back of the device.
4. Use a screw to x the device and the hanging plate from the bottom.
Wall punching size chart

12
Face Recognition Temperature Monitor user's manual
Wall punching size chart
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
This device must not be co-located or operating in conjunction with any other antenna or
transmitter.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
To comply with FCC’s RF radiation exposure limits for general population/uncontrolled
exposure, this device must be installed to provide a separation distance of at least 20cm from
all persons.
WARNING:
Any
changes
or
modifications
to
this
unit
not
expressly
approved
by
the
party
responsible for compliance could void the user’s authority to operate the equipment.
This
device
must
not
be
collocated
or
operating
in
conjunction
with
any
other
antenna
or
transmitter.
Other manuals for AI-321
1
Table of contents