Center 340017 User manual

Installation Guide
R32345746-002
340017 (EHE0200373)
RF Wireless 7 Day Programmable Thermostat
IMPORTANT: Please read these instructions fully prior to use as
they contain information that will help get the best from your
wireless thermostat, ensuring it is operating correctly and safely.
If during the installation or set up you experience any issues
please call 0344 292 7060 for assistance.
Must be installed by a competent person. To ensure your
safety make sure the mains power is switched OFF before
accessing wiring.
To prevent a short circuit from a loose wire:
• Multi-core cables: Only remove enough outer insulation
to allow secure fixing of the cores into the terminal block.
• Single core cables: Secure them together with a cable tie
as close as possible to the terminal block.
The Thermostat and Receiver Box within this pack are
Pre-bound
Install the Receiver Box
1 2 3
4 5
Wiring
On/off boiler (230V) 2-Port Zone ValveCombi boiler
ON
>30cm
0-30cm
Receiver Box
Basic Boiler
5(3)A
Permanent Live
not required
Receiver Box
5(3)A
Combi-
Boiler
T2T1
Receiver Box
5(3)A
V4043
Zone Valve
= M3.5
= N°6
a.
1.5-2.5mm²
6mm max.
2
1
Contents
2 x AA LR6AccessoriesTable StandReceiver BoxThermostat Wall Mount
Parameters
No
Description
Settings
3OT
Min. On Time
1- 5min
4LL
Lower Limit
5 - 21 °C
5UL
Upper Limit
21 - 35 °C
9LC
Fail Safe
0 = Disabled
1 = Enabled
10BL
Backlight
0 = Disabled
1 = Enabled
11CL
Clock
0 = 24h
1 = 12h
12DS
Daylight Saving
0 = Disabled
1 = Enabled
13TO
Temp. Offset
- 3 / + 3 °C
15SD
Reset Schedule
0
1 = Reset
16FS
Factory Reset
0
1 = Reset
17OP
Optimum Start
0 = Disabled
1 = Optimum Start
18OS
Optimum Stop
0 = Disabled
1 = Enabled
Install the Thermostat
1.2-1.5m
The Thermostat and Receiver Box in this pack
are pre-bound.
!
21.0
1:la
3s
Table Stand
Table Stand and Wall Mount
2 31
Wall Mount
21
The Wireless Thermostat communicates wirelessly to the Receiver Box which is wired to the boiler. If the Thermostat loses
wireless communication or becomes faulty, the boiler can be switched on or off manually using the button on the Receiver
Box.
• is displayed on the Thermostat when the wireless signal is good - The Receiver Box LED will be solid GREEN.
• + will flash on the Thermostat when the wireless signal is lost - The Receiver Box LED will flash RED.
• If communication is lost move the Thermostat to another location to try and restore communication.
To manually override the boiler using the Receiver Box:
1. Press the button once to switch the boiler
ON or OFF. The button LED should be:
• Solid GREEN when the boiler is ON.
• Off when the boiler is OFF.
Wireless Receiver Box
= M3.5
= N°6
Manufactured for and on behalf of Wolseley UK Limited,
2 Kingmaker Court, Warwick Technology Park,
Gallows Hill, Warwick, Warwickshire,
United Kingdom, CV34 6DY
Hereby, Wolseley UK Limited declares that this product is in
compliance with Directive 2014/53/EU. The full text of the
EU declaration of conformity is available at the following
internet address: http://www.wolseley.co.uk
Receiver Category 2
Max RF Power: 25mW
868-868.6MHz
(EU) 811/2013
Whilst every care has been taken to ensure that the information included in this document
was accurate at the time of printing, we reserve the right to change specifications at any time.
The photographs reproduced in this publication are within the constraints of the printing
process and are NOT to be used for matching purposes. E&OE.
For further information telephone 0344 292 7060
www.wolseley.co.uk
IG-340017.v01
WEEE Directive 2012/19/EU
At the end of the product life dispose
of the packaging and product in a
corresponding recycling centre. Do
not dispose of the unit with the usual
domestic refuse. Do not burn the product.
The binding operation described below is required if:
• Any of the system components (Wireless Thermostat or Receiver Box) are replaced.
• The Receiver Box has incorrect or no binding data stored (e.g. when pre-bound system pack
components have been mismatched).
NOTE: During the binding procedure keep approximately 1m distance between the Wireless Thermostat
and the Receiver Box.
1. Press and hold the Receiver Box push button for 15 seconds to reset any previously stored data.
After 15 seconds the red LED will change to flashing 0.1sec on/0.9sec off.
NOTE: After 5 seconds the red LED will start to flash 0.5sec on/0.5sec off, but continue to hold the button).
2. Release the push button.
3. Press and hold the Receiver Box push button for 5 seconds to enter the binding mode.
The Red LED will start flashing at 0.5sec on/0.5sec off to confirm the binding mode has been entered.
4. On the Wireless Thermostat press and hold MENU and for 3 seconds to enter the binding screen
with parameter 14A flashing
If 1 is shown then it is already bound to a Receiver Box. If 0 is shown then there are no Receiver Box bounded
5. To bind to a new Receiver Box, Press to enter the binding sub menu.
6. Press or to scroll to 1 and press again. After few seconds the binding result will be displayed
on the screen with 1 representing successful bind, 0 representing failure.
If successful the red LED on the Receiver Box is switched off to confirm successful binding operation.
Binding / Rebinding

Other Center Thermostat manuals

Center EHE0200158 User manual

Center

Center EHE0200158 User manual

Center 340018 User manual

Center

Center 340018 User manual

Center EHE0200364 User manual

Center

Center EHE0200364 User manual

Center 340022 User manual

Center

Center 340022 User manual

Center EHE0200153 User manual

Center

Center EHE0200153 User manual

Center 340023 User manual

Center

Center 340023 User manual

Center EHE0200153 User manual

Center

Center EHE0200153 User manual

Center EHE0200364 User manual

Center

Center EHE0200364 User manual

Center EHE0200361 RF User manual

Center

Center EHE0200361 RF User manual

Center EHE0200155 User manual

Center

Center EHE0200155 User manual

Popular Thermostat manuals by other brands

Tyco TA Operation and use guide

Tyco

Tyco TA Operation and use guide

Greystone TTLSO Series installation instructions

Greystone

Greystone TTLSO Series installation instructions

Lennox ComfortSense 3000 Series Operation manual

Lennox

Lennox ComfortSense 3000 Series Operation manual

meitav-tec FMT24-SUPER Owner's manual & technician settings

meitav-tec

meitav-tec FMT24-SUPER Owner's manual & technician settings

Honeywell TRADELINE T8011R installation instructions

Honeywell

Honeywell TRADELINE T8011R installation instructions

Siemens QFA3212.FWxN installation instructions

Siemens

Siemens QFA3212.FWxN installation instructions

Onyx ONX806-C Installation and operation manual

Onyx

Onyx ONX806-C Installation and operation manual

Vimar SMART CLIMA manual

Vimar

Vimar SMART CLIMA manual

Vaillant VR 51 Operating and installation instructions

Vaillant

Vaillant VR 51 Operating and installation instructions

LEDLux LL0250 user manual

LEDLux

LEDLux LL0250 user manual

White Rodgers 1F80-261 manual 

White Rodgers

White Rodgers 1F80-261 manual 

White Rodgers 1F88-270 installation instructions

White Rodgers

White Rodgers 1F88-270 installation instructions

Siemens RDJ100RF/SET Operating and installation instructions

Siemens

Siemens RDJ100RF/SET Operating and installation instructions

Aprilaire 8554 owner's manual

Aprilaire

Aprilaire 8554 owner's manual

OJ Electronics OWD5-1999 user manual

OJ Electronics

OJ Electronics OWD5-1999 user manual

COMEM TWM instruction manual

COMEM

COMEM TWM instruction manual

Heatstore HSUFDC Installation and operating instructions

Heatstore

Heatstore HSUFDC Installation and operating instructions

VOKERA OpenTherm 711 Setup guide

VOKERA

VOKERA OpenTherm 711 Setup guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.