CFR Altra Pro 400 Assembly instructions


ALTRA Series Operator Manual
TABLE OF CONTENTS
Unpacking your new Altra Series leaning Station .................................................1
INTRODU TION.....................................................................................................2
SAFETY INSTRU TIONS ......................................................................................3
GROUNDING INSTRU TIONS ..............................................................................4
SET UP INSTRU TION..........................................................................................4
Filter Installation..............................................................................................4
OPERATING INSTRU TIONS ...............................................................................5
MAINTENAN E
Daily Maintenance...........................................................................................9
Periodic Maintenance......................................................................................10
SPE IFI ATIONS
Altra PRO 400.................................................................................................
Altra PRO HEAT 400 ......................................................................................14
Altra Pro 1000 .................................................................................................17
TROUBLE SHOOTING GUIDE...............................................................................18
PLANOGRAPHS
Altra 400
Altra Pro 400 Back Panel Assembly................................................................14
Altra 400/Heat
Altra Pro 400 Tank Assembly..........................................................................16
Altra Pro 400 Pump/Motor Assembly ..............................................................18
Altra Pro 400 Heat
Altra Pro 400 Heat Base Assembly.................................................................20
Altra Pro 400 Heat Final Assembly .................................................................22
Altra Pro Heat Back Panel Assembly..............................................................24
Altra Pro 1000
Altra Pro 1000 Base Assembly .......................................................................26
Altra Pro 1000 Tank Assembly........................................................................28
Altra Pro 1000 Pump Motor Assembly ............................................................30
WIRING DIAGRAMS
Altra Pro 1000 115 V...............................................................................................32
Warranty..................................................................................................................35

ALTRA Series Operator Manual
Congratulations on your purchase of a CFR Altra Series Cleaning Station. Read this entire
manual before operating or servicing the Altra.
Unpac ing your new Altra Series Cleaning Station
The Altra Series Cleaning Station was thoroughly inspected, tested, and packaged to deliver the
e uipment in good operating condition. The freight carrier received and signed for the e uipment
in good condition. Damage can occur during shipping and to protect your interest, all cartons
must be inspected for damage (including any concealed damage) that might have occurred
during shipment. Any damage is the responsibility of the freight carrier and should be reported
immediately to the carrier. It is your responsibility to issue a claim and to receive compensation
from the freight carrier for any damage done in transit. Shipping damage is not warranted.
CC
CC AA
AA UU
UU TT
TT II
II OO
OO NN
NN
Read All Instructions, Warnings and Cautions Before Using
These guidelines are provided for your protection and convenience. Please
read them carefully. If you have any questions regarding the use of you
r
equipment call FR Technical Service at 888.878.4190. Failure to adhere to
instructions provided can potentially void any warranties. Precautions and
safety warnings are provided for your protection Failure to observe these
warnings could result in personal injury and damage to the equipment. When
using an electrical appliance, basic safety precautions should always be
followed.
WARNING
To avoid fire, do not use with a flammable or combustible liquid to clean floor.

ALTRA Series Operator Manual
INTRODUCTION
The ALTRA Series cleaning stations are the industry s most powerful and versatile systems for
the restoration cleaning of carpets, hard surfaces, upholstery, and modular office panels.
Altra Pro 400
The Altra Pro 400 is designed for carpet, upholstery and hard surface cleaning and restoration.
Altra Pro Heat 400
The Altra Pro Heat 400 with its built-in 2400 watt heater, is one of the most powerful portable
cleaning systems on the market.
Altra Pro 1000
The Altra Pro 1000 with 1,000 p.s.i. is the most powerful portable cleaning system on the
market.

ALTRA Series Operator Manual
IMPORTANT SAFETY INSTRUCTIONS
The Altra Series is intended for use only as described in this manual with recommended
attachments and chemicals. Using the Altra Station in any manner not described in this manual
can void the warranty. Use only manufacturer s recommended accessories.
READ ALL INSTRUCTIONS BEFORE USING
THIS PRODUCT IS INTENDED FOR COMMERCIAL USE ONLY
When using a electrical piece of e uipment basic precautions should be followed, including the
following:
WARNING! To reduce the risk of electric shock, fire, or injury:
1. Operators must read and understand this manual completely before operating the
e uipment.
2. Make sure all caution, warning, and instructional decals are in place and legible. Replace
damaged or missing labels.
3. Do not leave unit when plugged in. Unplug from outlet when not in use and before
servicing.
4. Connect to a proper grounded outlet only. (See Grounding Instructions.)
5. Do not use with damaged cord or plug.
6. Do not handle plug or unit with wet hands.
7. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around
sharp edges or corners. Do not run appliance over cord. Keep cord away from heated
surfaces.
8. Turn off all controls before unplugging.
9. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
10. Do not put any object into openings. Do not use with any opening blocked; keep free of
dust, lint, hair, and anything that may reduce air flow.
11. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot
ashes.
12. Do not use without filters in place.
13. Use extra care when cleaning stairs.
14. Do not use to pick up flammable or combustible li uids such as gasoline or use in areas
where they may be present.
15. Do not expose to rain. Store indoors.
16. If unit is not working as it should, has been dropped, damaged, left outdoors, or dropped
into water, take it to a local CFR service center.

ALTRA Series Operator Manual
GROUNDING INSTRUCTIONS
This unit must be grounded. Grounding provides the path of least resistance for electric current,
in the event of malfunction or breakdown, to reduce the risk of electric shock. This unit is
e uipped with a cord having an e uipment-grounding conductor and grounding plug. The plug
must be inserted into an appropriate outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING! Improper connection of the e uipment-grounding conductor can result in a risk
of electric shock. Check with a ualified electrician or service person if you are in doubt as to
whether the outlet is properly grounded. Do not modify the plug provided with the appliance —
if it will not fit the outlet; have a grounded outlet installed by a ualified electrician.
SET UP INSTRUCTION
1. Fill out Warranty Card and return it to CFR.
Filter Installation
Inlet Basket w/prefilter Install inlet basket with prefilter in it into the tank opening. Dump
and clean debris each time water is added and at the end of each
cleaning job.
Main Filter Wet the rim of the filter and position it on the filter mound. Twist
and slide over the mound by pushing downward.
Pump Protection Filter The stainless steel screen filter is installed at the bottom of the tank
inside the recycling filter.

ALTRA Series Operator Manual
OPERATING INSTRUCTIONS
1. Check to make sure pump protection and main filters are securely in place. The main filter
must be securely seated on the tank bottom. To properly seat the main filter, rotate the filter
1/8 turn while pushing down.
2. Fill tank with water to a depth of 2 (5 cm) below bottom of upper float level switch (at
rear of tank). Maximum in-tank water temperature to be used is 120° F to 130° F (49° to
54° C)
CAUTION: Water temperature above 140°F (60°C) will cause the tank to buckle from the
strong vacuum suction.
3. Add in-tank cleaner per chemical label use instructions. In addition, pre-spraying is often
desirable and will assist in producing the fastest and best cleaning results.
NOTE: Use caution when moving machine on inclines with fluid in the tank to prevent
fluid from entering the vacuum standpipe at back of machine and flooding the vacuum.
4. Install inlet filter screen into top of tank.
5. Add 3 ounces of Defoam product to the inlet filter.
6. Connect power cords to twist lock connectors and plug cords into one 20 and one 15 amp
or larger wall outlets on separate circuits.
7. Attach fluid hose to the uick-disconnect on the front of the machine
8. Prime pump by re-circulating fluid through fluid hose (without a nozzle attached) into the
tank for 30 to 60 seconds. Re-circulating the fluid primes the pump and expels trapped air
from the system
9. Attach the desired tool to the valve end of the hose assembly and of the hose assembly.
10. Close tank cover, attach hose assembly to tank cover, turn on vacuum, pump, and heater
switches.
11. Clean surface with tool attached to hose assembly. CAUTION: The hose trigger valve will
get hot during use when the heater is turned on for Altra Pro 400 heat.
12. During the cleaning process, the fluid level will be reduced and the lower level float switch
will shut off the pump. When the pump shuts off, drain and rinse tank, rinse recycling
filter, refill with fresh water and cleaning chemical, and continue cleaning.
CAUTION! When cleaning, monitor foam in the machine’s tank. Areas cleaned with other
cleaning e uipment or chemicals may cause excessive foam to collect in the tank.
WARNING! EXCESSIVE FOAM IN THE TANK MAY CAUSE VACUUM MOTOR
FLOODING AND MACHINE DAMAGE. Pour one to two ounces of CFR Defoam directly
into the tank or into the vacuum hose while the vacuum is running.
When finished cleaning, perform the daily maintenance procedure. Be sure that all filters are
cleaned thoroughly and replaced in machine. Leave cover open for drying.

ALTRA Series Operator Manual
TOOL USAGE
Hose Assembly
Attach hose assembly to machine by attaching vacuum hose to the tank lid and the fluid hose to
the front of the machine. If the fluid hose is difficult to insert, the system pump pressure can be
relieved by pushing the prime switch or dialing down the pressure with the adjusting knob. Do
not operate the fluid switch when using the hose assembly and tools.
Carpets
Place tool on surface to be cleaned and move tool at the rate of a slow walk. Apply cleaning fluid
by pushing on the valve lever. When using floor tools, cleaning fluid is applied on the forward
stroke only. Use only enough downward pressure on the tools to move them effectively (push
and pull stroke). Use of excessive downward pressure on the tools will decrease their efficiency.
Always finish cleaning with a dry stroke (closed valve condition). It is very important to keep
tools properly seated to the surface being cleaned to produce maximum cleaning effectiveness
and minimum drying times. Multiple wet and dry strokes may be used on excessively soiled
areas. Clean inline strainer on carpet tool before using tool.
Upholstery
Place hand tool on surface to be cleaned. Move (pull and push) hand tool at a rate of about one
foot per second. Apply cleaning fluid on the pull stroke only. Overlap passes by about 1/4 inch.
When cleaning upholstery edges, hold finger over part of tool to prevent over spray. Edges can
also be cleaned by placing tool on edge of upholstery and moving it parallel to the edge. Use of
excessive downward pressure on the surface will decrease the tool’s efficiency. Always finish
cleaning with a dry stroke (closed valve condition). It is very important to keep all tools properly
seated to the surface being cleaned to produce maximum cleaning effectiveness and minimum
drying times. Multiple wet and dry strokes maybe used on excessively soiled areas.

ALTRA Series Operator Manual
MAINTENANCE
Daily Maintenance
To maintain optimum performance the e uipment, tools and filters should be cleaned after each
use. Replace any filters that cannot be cleaned or are damaged. Nozzles that cannot be cleared
should be discarded. Wipe down the e uipment with a damp cloth to keep clean and preserve
the appearance.
1. Tools and wands
Rinse opening of tool with water to eliminate any debris. Wipe tool with damp cloth and
store with head up to prevent clogging of nozzle.
2. Filters
Inlet Basket w/prefilter Dump and clean debris at the end of each operation.
Main Filter Remove the main filter, rinse out and clean thoroughly at the end
of each operation.
Pump Protection Filter Rinse at the end of each operation.
In-Line Strainer Filter Disconnect the In-line Strainer Filter by using the uick
disconnect coupler. Remove the filter and rinse with water.
Remove any debris from the strainer. Keep o-ring and threads of
the plug lubricated. CFR DeFoam is a good lubricant or use a
non-petroleum based lubricant. This will ensure a tighter seal.
3. Tank
Dump waste water and rinse inside of the tank with pump protection filter intact at the end
of each operation. Failure to do this will cause a serious problem to the next operation(s).

ALTRA Series Operator Manual
Periodic Maintenance
1. Check power cord for any breaks, separations, or cuts. Make sure the ground pin on the
connector is intact or the machine will be unsafe. Make sure the ground pin on all three
prongs on the twist lock connector are intact.
2. Check for plugged nozzles when using tools. If streaking occurs during cleaning, a plugged
nozzle may be the cause. A plugged or partially plugged nozzle can be identified by holding
the tool 5-7" above the surface and checking for an even spray pattern. To clean a plugged
nozzle, remove the nozzle and direct pressurized air backwards through the nozzle or
backwash the nozzle with water. A convenient method is to insert the nozzle into a garden
hose ball valve, tighten the ball valve to a faucet, and turn on the water. (CFR has ball
valves available, part #7AX020). Inspect nozzle and repeat cleaning procedure, if
necessary. Discard nozzles that cannot be cleared. Tool nozzles wear and must be replaced
after 200-250 hours of use.
3. Occasionally open side panel(s) and inspect hose and other connections for leaks. Repair or
replace any leaking parts. Always disconnect power cord, before removing side panels.
4. It is very important to monitor machine operating hours for proper maintenance of the
motors and pumps. After 700 hours of operation, the vacuum motor brushes should be
inspected by an authorized repair station and replaced if worn (length is _ inches or less).
When replacing brushes, carefully insert brushes without crimping brush follower spring.
5. Check vacuum motor performance using a vacuum gauge (CFR #70412A). Place this gauge
on the tank inlet fitting with the vacuum turned on. Water lift should be between 120 and
135 inches. If the reading is lower, check for air leaks in the tank, cover gasket, and drain
hose.
6. Check pump performance occasionally against built-in pressure gauge.
Altra Pro 400/Altra 400 Heat - Pump running pressure should be 400 + 10 p.s.i. When
pumping fluid through one #04 nozzle, the pressure should be 340 + 20 p.s.i.
Altra Pro 1000 — Pump running pressure should be 1000 p.s.i. When pumping fluid through
one #04 nozzle, the pressure should be 940 + 20 p.s.i.
If the pumping pressure is outside of this range, check and clean the inlet filters to ensure
the pump is getting enough fluid. If the pumping pressure is outside of this range, call your
dealer or authorized repair station.
7. For extended storage or between uses in cold climates drain the system and flush pump with
automobile windshield washer fluid. If the pump is frozen it can be severely damaged.
8. Check main filter for plugging. Plugged filter will cause problems not only to daily
operations but to the e uipment itself. Once the filter is plugged, rinsing is not enough. Clean
the tank and fill with fresh water. Using filter cleaning nozzle assembly (CFR60567A) with
pressure of 400 p.s.i. wash off all debris inside out.

ALTRA Series Operator Manual
SPECIFICATIONS — ALTRA PRO 400
Power ord Two detachable 35 (10.7 meter) ords, 12 Ga., 3 Wire, Molded End Plug
Voltage 115 Volts A , 60 HZ
Amp Vacuum Motor — 12.75 Amps
Pump Motor — 2.57 Amps
Tank Volume 15 Gallons (57 liters)
Fill Level 2 (5 cm) below the bottom of the Vacuum Float Switch.
Vacuum 3 stage with maximum 135 inch of water lift.
Pump Motor 1/3 HP A Motor
Pump Plunger Type: 0 to 400 psi.
Float Switches High float switch for Vacuum shut-off. Low float switch for Pump shut-off.
Weigh 135 lbs (66 kg)
Height 43.5" (110.5 cm)
Width 16" (40.6 cm)
Length 38.5" (98 cm)
Wheels 10 (25 cm) Non-marking wheels.
asters 4 (10 cm) Non-marking wheels.
Body Rotationally molded polyethylene.
Machine Handle hrome plated steel; secured to machine body with stainless cap nuts.
Filters Three filters: Inlet Filter, Recycling Filter, and Screen Filter.
Electrical Safety
Features
GF I (Ground Fault ircuit Interrupter): The GF I protects the operation from
transient or accidental grounding in the electrical system. Should the machine
develop an unwanted ground, the GF I reset button will trip and shut off electricity
to the vacuum and pump motors.
ircuit Breakers: Overload circuit breakers are placed in both the pump and
vacuum circuits to protect against unusually heavy current (ampere) loads. If either
breaker trips, the pump motor or vacuum motor is overloaded.

ALTRA Series Operator Manual
SPECIFICATIONS — ALTRA PRO 400 Heat
Power ord Two detachable 35 (10.7 meter) ords, 12 Ga., 3 Wire, Molded End Plug
Voltage 115 Volts A , 60 HZ
Amp Vacuum Motor — 12.75 Amps
Pump Motor — 2.57 Amps
Heater — 18.5 Amps
Tank Volume 15 Gallons (57 liters)
Fill Level 2 (5 cm) below the bottom of the Vacuum Float Switch.
Vacuum 3 stage with maximum 135 inch of water lift.
Pump Motor 1/3 HP A Motor
Pump Plunger Type: 0 to 400 psi.
Heater 2400 watts — feeds output fluid hose connection
Float Switches High float switch for Vacuum shut-off. Low float switch for Pump shut-off.
Weigh 135 lbs (66 kg)
Height 43.5" (110.5 cm)
Width 16" (40.6 cm)
Length 38.5" (98 cm)
Wheels 10 (25 cm) Non-marking wheels.
asters 4 (10 cm) Non-marking wheels.
Body Rotationally molded polyethylene.
Machine Handle hrome plated steel; secured to machine body with stainless cap nuts.
Filters Three filters: Inlet Filter, Recycling Filter, and Screen Filter.
Electrical Safety
Features
GF I (Ground Fault ircuit Interrupter): The GF I protects the operation from
transient or accidental grounding in the electrical system. Should the machine
develop an unwanted ground, the GF I reset button will trip and shut off electricity
to the vacuum and pump motors.
ircuit Breakers: Overload circuit breakers are placed in both the pump and
vacuum circuits to protect against unusually heavy current (ampere) loads. If either
breaker trips, the pump motor or vacuum motor is overloaded.

ALTRA Series Operator Manual
SPECIFICATIONS — ALTRA Pro 1000 / Pro 1000 220/240 Volt
Power ord Two detachable 35 (10.7 meter) ords, 12 Ga., 3 Wire, Molded End Plug
Voltage 115 Volts A , 60 HZ /220/240 Volts, A , 50 HZ
Amp Vacuum Motor — 12.75 Amps
Pump Motor — 14 Amps
Tank Volume 15 Gallons (57 liters)
Fill Level 2 (5 cm) below the bottom of the Vacuum Float Switch.
Vacuum 3 stage with maximum 135 inch of water lift.
Pump Motor A Motor
Pump Triplex Plunger Type: 0 to 1000 p.s.i..
Float Switches High float switch for Vacuum shut-off. Low float switch for Pump shut-off.
Weigh 135 lbs (66 kg)
Height 43.5" (110.5 cm)
Width 19.5" (49.5 cm)
Length 38.5" (98 cm)
Wheels 10 (25 cm) Non-marking wheels.
asters 4 (10 cm) Non-marking wheels.
Body Rotationally molded polyethylene.
Machine Handle hrome plated steel; secured to machine body with stainless cap nuts.
Filters Three filters: Inlet Filter, Recycling Filter, Screen Filter
Electrical Safety
Features
GF I (Ground Fault ircuit Interrupter): The GF I protects the operation from
transient or accidental grounding in the electrical system. Should the machine
develop an unwanted ground, the GF I reset button will trip and shut off electricity
to the vacuum and pump motors.
ircuit Breakers: Overload circuit breakers are placed in both the pump and
vacuum circuits to protect against unusually heavy current (ampere) loads. If either
breaker trips, the pump motor or vacuum motor is overloaded.

ALTRA Series Operator Manual
TROUBLE SHOOTING GUIDE
Vacuum or pump will not run • heck that electrical cord is firmly seated in wall outlet.
• heck and reset building circuit breaker if tripped.
• heck GF I on back of machine and reset if tripped.
NOTE: GF I and/or circuit breaker may trip if vacuum motor is
flooded. Open tank cover and try to run vacuum motor for 10
minutes to dry vacuum motor. If the GF I trips again, wait 5
minutes, reset and try vacuum again.
• heck vacuum/pump switch. It should be in the on position.
• heck upper float eyes or dots making sure they point up and the
lower float eyes point down.
Trips building circuit brea er • ircuit is overloaded — move cord to a different wall outlet.
• If using an extension cord, make sure it is in good condition, less
than 70 feet long and #10 gauge or heavier.
• heck plug end twist lock connector, and cord for damage.
Vacuum won t run. • Chec vacuum switch. It should be in the on position.
• heck circuit breaker and reset if tripped.
NOTE: GF I and/or circuit breaker may trip if vacuum motor is
flooded. Open tank cover and try to run vacuum motor for 10
minutes to dry vacuum motor. If the GF I trips again, wait 5
minutes, reset and try vacuum again.
• heck upper float — eyes or dots on white float must point up.
Move float up and down to see if vacuum will turn on. Water level
must be below upper float. Float must be in the lowest position.
Pump won t run • heck pump switch — it should be in the on position.
• heck pump circuit breaker (5 amp) and reset if tripped.
• heck fluid level must have at least 4 gallons in tank.
• heck ultra filter. If dirty, drain and flush tank and remove and clean
filter.
• heck lower float — eyes or dots on white float must point down.
Move float up and down to see if vacuum will turn on. Move float up
and down to see if pump will turn on. lean if sticking. Float must
be in highest position (floating) for pump to operate.
Pump tries to run and then
blows circuit brea er
• heck power cord for frayed, cut or worn spots and twist lock
connector for signs of overheating.
• If using an extension cord, ,make sure it is in good condition, less
than 70 feet long and #10 gauge or heavier.
• heck pump static PSI — must be 400 psi or less
• heck wall outlet voltage. If below 105 volts, pump will not work.
Pump starts and stops • heck for dirty Ultra Filter. Water level should be the same inside
and outside of filter.
• heck for sticking pump float.
• heck fluid level — must have at least 4 gallons in tank.
Excessive pressure drop
when cleaning
(exceeds 100 psi)
• Adjust static pressure to 400 psi when not cleaning.
• heck and clean main cloth filter and ball strainers in tank.
• heck and replace worn spray nozzles and loose or leaking
fittings/inline strainer.
• Purge excess air from pumping system with prime switch.

ALTRA Series Operator Manual
TROUBLE SHOOTING GUIDE
Water dripping from bottom
of machine exhaust.
• heck machine for excess foaming. Add FR Defoam to tool hose
and tank. Open machine top cover and let vacuum run for 10
minutes to dry out vacuum motor, then close lid and resume
cleaning.
• heck drain hose plug; must be securely fastened to prevent air
leaks to vacuum causing vacuum flooding. Hose will vibrate if there
is an air leak.
Head Assembly lea s. • Leave vacuum running for 1 minute when finished cleaning to clear
hose.
• heck for holes/breaks in vacuum hose.
• Make sure the inline strainer is properly tightened and fluid hose
connectors are fully seated.
Carpet too wet. • NOTE: FR floor tool is used in forward direction only.
• heck carpet tool position — head must be completely seated on
carpet to provide good drying times.
• heck tool and hose for any obstructions.
• heck lid cover sealing properly. Is filter case properly seated in
tank? Is lid gasket in good shape with no cuts, cracks, or
worn/compressed areas?
• heck for cracks in lid cover.
• heck drain hose and fittings for cracks and tears. Make sure drain
plug is securely fastened. Hose will vibrate if there is an air leak.
• Verify inlet filter knob is securely fastened to tank.
• heck tool hose for holes, cracks, or cuts.
• heck hose cuffs — must seat firmly on tank fitting and tool.
• heck water dripping from bottom of machine exhaust. If present,
check machine for excess foaming.
• Verify that cleaning head spray bar is fully seated.
• heck carpet installation. Some carpets are installed on uneven
surfaces with ridges and bumps. It is difficult to get good drying
times with this type of installation.
Strea s on carpet. • heck tool and hose for obstructions.
• heck and clean inline strainer filter.
• heck and clean main cloth ultra filter.
• heck nozzles for full spray. lean if clogged or replace if worn.
• heck pump pressure drop while cleaning. Should not drop more
than 100 p.s.i. Make sure air is out of system by re-priming pump. If
there is still a problem, remove and clean ball shaped strainer
screens.
• Make sure strokes overlap a minimum of 3 inches.
• heck FR chemical usage instructions for proper application.
• Multiple cleanings may be needed to clean deeply imbedded dirt
that is pulled to the surface by FR s deep cleaning technology.
Offset cleaning passes by 6 inches.
No fluid from cleaning head • heck that prime switch is in off position.
• heck and clean inline strainer.

ALTRA Series Operator Manual
WARRANTY
FR, a Tacony company, warrants new products manufactured and sold under the
name FR to be free from defects in materials and workmanship under normal use and
service. FR s obligation under this warranty is limited to repairing or replacing, at our
option, such products or parts which are returned to our factory authorized service
center, freight prepaid, within the warranty period and are found to be defective in
materials or workmanship. For rotationally molded polyethylene housings and aluminum
frames and chassis this warranty expires 60 months from the date of registration; if the
warrant is not registered, it expires 60 months from the factory shipment date. For all
other components, with the exception of wear items (i.e. filter, nozzles, etc.) this
warranty expires 12 months from the date of registration on the warranty. If not
registered, is expires 12 months from the factory shipment date. For hoses, tools, and
other attachments manufactured and sold by FR, this warranty expires 12 months
form factory shipment date. Parts replaced or repaired under warranty are guaranteed
for the remainder of the original warranty period. Replacement parts that have become
defective through wear or abuse are not included in this warranty. FR will pay service
labor to the distributor or authorized service repair center per the warranty flat rate
schedule. Service labor will be paid for two years on all warranted polyethylene
housings, aluminum frames and chassis, and one year on all other warranted
components.
FR systems are designed for use only with specially formulated FR Recyclable
leaning hemicals. Use of any other chemical in FR systems may cause damage to
the pump, motor and other components and may void the warranty.
This warranty shall cease to be in effect if repairs, replacements or alternations are
made by the purchaser or any non-authorized service station. This warranty does not
apply to damage caused by misuse, abuse, or negligence of the buyer or third party, or
damage due to transportation of product.
CFR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING WITHOUT
LIMITATIONS, ANY WARRANTIES OF FITNESS OR MERCHANTABILITY, EXCEPT AS
EXPRESSLY SET FORTH ABOVE WITH RESPECT TO SUCH PRODUCTS OR PARTS
THEREIN. NOR SHALL CFR HAVE INCURRED ANY OTHER OBLIGATIONS OR
LIABILITIES ON ITS PART OR BE LIABLE FOR ANY ANTICIPATED OR LOST
PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, TIME CHARGES
OR ANY OTHER LOSSES INCURRED IN CONNECTION WITH THE PURCHASE,
INSTALLATION, REPLACEMENT OR REPAIR OF SUCH PRODUCTS OR ANY PARTS
THEREIN WHETHER ORIGINAL EQUIPMENT OR INSTALLED AS A REPLACEMENT,
COVERED BY THIS WARRANTY OR OTHERWISE; AND CFR DOES NOT AUTHORIZE
ANY PERSONA TO ASSUME FOR CFR ANY OTHER LIABILITY IN CONNECTION
WITH THE PRODUCTS OR PARTS THEREIN.

ALTRA Series Operator Manual
For more information about top quality FR products
please see your local FR distributor or visit us at
wwwcfrcorp.com
Thank you for purchasing
FR Environmental leaning Systems.
FR Environmental leaning Systems
3101 Wichita ourt
Fort Worth, Texas 76140
817.551.0700
800.533.2557
FAX 817.551.0719
This manual suits for next models
2
Table of contents
Other CFR Vacuum Cleaner manuals