•Sensitivity adjustment: Detection range can be adjusted
between 5m & 10m approximately (this will be dependent on
external factors such as mounting height angle & background
temperature). If adjusted to “-“ position detection range will be
approximately 5m if adjusted to “+” position detection range
will be up to 10m.
•Manual override function: To manually override the PIR the
fitting must be switched ON and in automatic mode. Then
switch the AC supply via a wall switch OFF-ON OFF-ON (twice)
within 2 seconds the sensor will now hold the light ON
continuously for 5 hours. After 5 hours the sensor will return
back to the automatic mode.
To return the PIR back to automatic mode there are two
methods:
1. Turn off the AC supply via a wall switch then after 10
seconds re-apply the AC supply via the wall switch the
PIR will then enter automatic mode.
2. Switch the AC supply via a wall switch ON-OFF ON-OFF
(twice) within 2 seconds the PIR will then enter
automatic mode.
PIR controls showing adjustable dials for time, lux and sensitivity