High Lumen LED PIR Floodlights
15w, 30w, 50w
Models: SLFLF15BP, SLFLF30BP, SLFLF50BP
SLFLF15BP
SLFLF30BP SLFLF50BP
Installation Manual
Introduction
Thank you for purchasing your Challenger high lumen led floodlight
these instructions should be read carefully and retained for further
reference and maintenance.
IMPORTANT
•Installation must be carried out by a skilled electrician who is
familiar with the appropriate standards and technical
requirements of the appliance also taking in to consideration the
latest building regulations.
•The person carrying out the installation is to check and verify
that the total load on the circuit including the rating of the
cable fuse and/or circuit breaker is not exceeded.
•Ensure there is adequate ventilation around the luminaire
•Ensure the AC mains supply is isolated when installing or
servicing.
•This product must be earthed.
•Once illuminated DO NOT look or stare at the LED fitting directly
when in close proximity.
•Never modify the luminaire there are no user serviceable parts
inside.
•Please observe the installation/mounting height to ensure
correct operation.
•The luminaire has a selectable wattage output (30w & 50W
models only). Please ensure that the correct wattage output
has been selected as this will have an impact on the lighting
design to ensure the correct light levels are achieved.
Specification
•High lumen output LED floodlights
•Slimline lightweight design
•120° PIR with up to 10m detection distance
•Installation Height 2.0-2.8m
•Adjustable lux setting 3-1000lux
•Adjustable time delay up to 12 minutes
•Manual override (OFF/ON OFF/ON) light on for 5 hours
•Polycarbonate encapsulated lens module
•Lumiled 2835 LED chip
•Pre-wired cable – 1m
•90° x 120° beam angle
•5000k Colour temperature
•IP65 ingress protection
•IK08 impact protection
•50 000 hours rated life
•Input voltage – 100-277V AC 50/60Hz
•Power factor - PF≥0.9
•CRI rating - >70
•Operating temperature -20°~+40°c
•5 year warranty
•Selectable wattage (SLFLF30BP & SLFLF50BP models only)
Specification
Model Lumens
Wattage
Dimensions
mm)
Input
Current
Weight
SLFLF15BP
1950 15w 148x128x45
0.2A 0.58Kg
SLFLF30BP
3900
2600
1950
1300
30w
20w
15w
10w
216x190x50
0.37A 1.23Kg
SLFLF50BP
6500
3900
2600
1950
50w
30w
20w
15w
247x238x52
0.72A 1.62Kg
PIR Function
•Time adjustment: Time can be adjusted between 8(±5) seconds
and 12(±2) minutes. When adjusted to “-“ position the time will
be 8 seconds when adjustable to “+” position the time will be 12
minutes. Note: When the PIR has timed out and switched the
LED lamp off there will be a short delay of 2 seconds before the
sensor can be activated again.
•Adjustable lux setting: Move adjuster between &
position to set lux if moved to sun position luminaire will work
during the day & night if moved to moon position luminaire will
work at night only (less than 20 lux).
•Sensitivity adjustment: Detection range can be adjusted
between 5m & 10m approximately (this will be dependent on
external factors such as mounting height angle & background
temperature). If adjusted to “-“ position detection range will be
approximately 5m if adjusted to “+” position detection range
will be up to 10m.
•Manual override function: To manually override the PIR the
fitting must be switched ON and in automatic mode. Then
switch the AC supply via a wall switch OFF-ON OFF-ON (twice)
within 2 seconds the sensor will now hold the light ON
continuously for 5 hours. After 5 hours the sensor will return
back to the automatic mode.
To return the PIR back to automatic mode there are two
methods:
1. Turn off the AC supply via a wall switch then after 10
seconds re-apply the AC supply via the wall switch the
PIR will then enter automatic mode.
2. Switch the AC supply via a wall switch ON-OFF ON-OFF
(twice) within 2 seconds the PIR will then enter
automatic mode.
PIR controls showing adjustable dials for time, lux and sensitivity
Top view – detection angle Side view – detection distance
Installation
•Ensure the electrical AC power is switched OFF before and
during installation
•For the AC supply cable and connections a cable that is rated to
90°C should be used
•The sensor is designed for optimum performance when mounted
2.0-2.8 meters above ground level
•To avoid nuisance triggering the sensor should be directed away
from trees shrubs and flues heat extraction units.
•The PIR Sensor range may vary slightly depending on the
mounting height and location. The detection range of the unit
may also alter with temperature changes (higher temperatures
will result in reduced range). Before selecting a place to install
the fitting you should note that movement across the sensor is
more effective than movement directly toward or away from the
sensor. If movement is made walking directly towards or away
from the sensor and not across the apparent detection range
will be substantially reduced.
•Ensure the luminaire is securely fixed to a surface free from
vibration
•When adjusting the angle of the fitting please ensure that there
is enough slack in the cable so the range of movement of the
luminaire is unhindered
•Ensure that the correct wattage output has been selected (30w
& 50w models only) as this will have an impact on the lighting
design to ensure the correct light levels are achieved.
•A suitable IP rated junction box is required for the premade AC
electrical connections (Brown = Live Blue = Neutral and
Yellow/Green = Earth). This luminaire must be earthed
•Check the lighting fixture is firmly fixed and the Allen bolts have
been inserted in to the bracket
•Check all the connections are wired and terminated correctly
Adjust the wattage via dip switch
please remove the screw on cap and replace)
Ensure that the correct wattage output has been selected (30w & 50w
models only) as this will have an impact on the lighting design to ensure the
correct light levels are achieved.
SLFLF30BP SLFLF50BP
Refer to the following diagram when you install the fixture.
SLFLF15BP SLFLF30BP
SLFLF50BP
1. Turn off the AC Supply
Fix the luminaire bracket
to the surface.
2. Keep enough slack in
cable to ensure when
adjusting the angle the
movement is unhindered
3. Connections- AC-Live:
Brown AC-Neutral: Blue
GND Earth: Yellow-
Green.
4. Check the circuit and connections are correct prior turning on
the AC supply
5. Ensure that the correct wattage output has been selected (30w
& 50w models only) as this will have an impact on the lighting
design to ensure the correct light levels are achieved.
Please Note: The cable must be connected either through a waterproof
connector or junction box. The waterproof connector or junction box is
not supplied and will need to purchase separately.
Maintenance
Repairs should only be carried out by a suitably qualified person.
Regular cleaning of luminaires should be carried out at regular intervals
not only to ensure good optical performance but also ensure that dirt
does not accumulate to such an extent as to impair the electrical or
thermal safety of the fitting. This should be done with the luminaire
switched off/isolated and a soft damp cloth should be used do not use
any chemicals or abrasives.
Light Source Maintenance
The light source of this luminaire is not replaceable; in case the light
source needs to be replaced (e.g. at the end of its life) the whole
luminaire shall be replaced.
Warranty
This product is covered by an extended warranty for 5 years from date
of purchase.
The extended warranty is available for installations in the UK or Ireland
by a competent person in accordance with the current building and IEE
wiring regulations.
If the defective product is no longer available then Challenger may
provide alternatives of similar specification and quality.
The ambient temperatures and environment and voltage range
according to manufacturer specifications are not exceeded
The product is not exposed to any adverse mechanical stresses or
impact
For full terms and conditions in regard to our extended warranty please
refer to the website.
Follow us for all the latest news and product information
CHALLENGER SECURITY PRODUCTS
10 Sandersons Way
Blackpool FY4 4NB
Email: [email protected]
Web: www.challenger.co.uk
Due to our policy of continuous improvement we reserve the right to change specification
without prior notice. Errors and omissions excepted. These instructions have been carefully
checked prior to publication. However no responsibility can be accepted by Challenger for any
misinterpretation of these instructions.
Challenger_SLFLF15BP_SLFLF30BP_SLFLF50BP_Instructions_Rev01

This manual suits for next models

2

Other Challenger Floodlight manuals

Challenger SLFLF15B User manual

Challenger

Challenger SLFLF15B User manual

Challenger SLFLO460B User manual

Challenger

Challenger SLFLO460B User manual

Popular Floodlight manuals by other brands

EuroLite ML-30 CDM Multi Lens Spot user manual

EuroLite

EuroLite ML-30 CDM Multi Lens Spot user manual

BARRON TRACE-LITE FXA Series installation instructions

BARRON

BARRON TRACE-LITE FXA Series installation instructions

Emos 1531224200 manual

Emos

Emos 1531224200 manual

Arlec HL15 installation instructions

Arlec

Arlec HL15 installation instructions

Wetelux CE-82-Y S.S 300 instruction manual

Wetelux

Wetelux CE-82-Y S.S 300 instruction manual

thomann STAIRVILLE LED Bar 120/4 RGB DMX user manual

thomann

thomann STAIRVILLE LED Bar 120/4 RGB DMX user manual

Stairville Stage Flood QCL 48x10W user manual

Stairville

Stairville Stage Flood QCL 48x10W user manual

hylite Mightylite Pro MLP240B Installation & operating instructions

hylite

hylite Mightylite Pro MLP240B Installation & operating instructions

Chauvet Intimidator Barrel LED 300 Quick reference guide

Chauvet

Chauvet Intimidator Barrel LED 300 Quick reference guide

EuroLite LED IP FL-20 user manual

EuroLite

EuroLite LED IP FL-20 user manual

Major tech ELF50CW instruction manual

Major tech

Major tech ELF50CW instruction manual

silversun PRO SPORT FLS50CW installation guide

silversun

silversun PRO SPORT FLS50CW installation guide

Larson Electronics HAL-TRN Series instruction sheet

Larson Electronics

Larson Electronics HAL-TRN Series instruction sheet

Kemot URZ3454 owner's manual

Kemot

Kemot URZ3454 owner's manual

Utilitech Pro 006219B manual

Utilitech Pro

Utilitech Pro 006219B manual

Eterna VECORCFL10 installation instructions

Eterna

Eterna VECORCFL10 installation instructions

WE-EF FLC240 BL Installation and maintenance instructions

WE-EF

WE-EF FLC240 BL Installation and maintenance instructions

Milwaukee M12 AL Operator's manual

Milwaukee

Milwaukee M12 AL Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.