13
PROGRAMMING >> FROM THE TAC1 KEYPAD
GENERAL INSTRUCTION
CHANGE THE MASTER CODE
1. Enter the Master Code:
2. Enter the Program Code:
The unit will beep.
3. Enter:
4. Enter the new Master Code:
The unit
will beep.
Write down the Master Code and store in a secure
location.
MICROPHONE SENSITIVITY
Allows the resident to hear the visitor at the unit,
1 = Low, 2 = Medium and 3 = High. Default level is 2.
1. Enter the Master Code:
2. Enter the Program Code:
3. Enter the Volume Level:
or
or
SPEAKER VOLUME
Allows the visitor to hear the resident at the unit,
1 = Low, 2 = Medium and 3 = High. Default level is 2.
1. Enter the Master Code:
2. Enter the Program Code:
3. Enter the Volume Level:
or
or
ADJUST RELAY OUTPUT TIME (RELAY 1)
The amount of time (in seconds) the relay remains active.
Default level is 0.5 seconds.
1. Enter the Master Code:
2. Enter the Program Code:
3. Enter the Output Time (in seconds):
Example:
0000 = 0.5 Seconds (Minimum)
0010 = 10 Seconds
8000 = 8000 Seconds (Maximum)
ADJUST RELAY OUTPUT TIME (RELAY 2)
The amount of time (in seconds) the relay remains active.
Default level is 0.5 seconds.
1. Enter the Master Code:
2. Enter the Program Code:
3. Enter the Output Time (in seconds):
Example:
0000 = 0.5 Seconds (Minimum)
0010 = 10 Seconds
8000 = 8000 Seconds (Maximum)
ENABLE TELCO MODE
Telco Mode is using the main telephone line for the unit’s
communications to the house or complex.
1. Enter the Master Code:
2. Enter the Program Code:
ENABLE INTERCOM (NO TELCO) MODE
Intercom Mode is a stand alone system that allows
communication between the unit and a resident’s phone
1. Enter the Master Code:
2. Enter the Program Code:
ENABLE INDEPENDENT RELAY OUTPUT CONTROL
1. Enter the Master Code:
2. Enter the Program Code:
ENABLE PARALLEL RELAY OUTPUT (DEFAULT)
1. Enter the Master Code:
2. Enter the Program Code:
NOTE: Use the STAR Key “*” to cancel any input.
NOTE: Keypad commands are to be entered in a single string to result in success (indicated by double high success tone). Stop and go
keystrokes will result in negative tones (low single and triple fail tones).
PROGRAMMING INSTRUCTION SYNTAX KEYSTROKES
General Programming Master Code + Command 1234 + 1 (12,123)
Code Programming Master Code + Command + Code 1234 +1(12) + 1234
Relay Programming Master Code + Command + Setting 1234 + 123 + 1234
Level Adjustment Master Code + Command + Setting 1234 + 12 + 1-3