CHERUBINI A510078 User manual

DRAFT
ISTRUZIONI - INSTRUCTIONS - EINSTELLANLEITUNGEN
INSTRUCTIONS - INSTRUCCIONES
Actuator for motors with
standard connection EN
A510078 META
WIRED MOTOR CONTROLLER 7


3
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
Index:
Device description ................................................................................................. p. 4
Technical specications.......................................................................................... p. 5
Safety information ................................................................................................. p. 5
Electrical connections diagram .............................................................................. p. 6
Device installation.................................................................................................. p. 7
LED status indicator ............................................................................................... p. 7
Add/remove the device into a Z-WaveTM network (classic)..................................... p. 8
SmartStart inclusion............................................................................................... p. 9
S2 Secure Inclusion ................................................................................................ p. 9
Supported command classes ............................................................................ p. 10-11
Device control ........................................................................................................ p. 12
Controlling the device by External Switches ....................................................... p. 12
Controlling the device by a Z-WaveTM controller ................................................. p. 13
Reset to the factory settings .................................................................................. p. 14
Firmware update.................................................................................................... p. 14
Ofine setup mode ................................................................................................ p. 15
Congurations ................................................................................................. p. 16-20
EU declaration of conformity
CHERUBINI S.p.A. declares that the product is in conformity with the relevant Union
harmonisation legislation: Directive 2014/53/EU, Directive 2011/65/EU.
The full text of the EU declaration of conformity is available upon request at the following
website: www.cherubini.it.
Failure to comply with these instructions annuls CHERUBINI’s responsibilities and
guarantee.
The crossed-out wheelie bin symbol indicates that the product must be collected
separately from other waste at the end of its useful life. Therefore, users should
deliver this product to appropriate waste collection points or return it to their
dealers at the end of its service life. See your local authority’s regulations.
Adequate waste sorting for subsequent processing and environmentally compatible
disposal helps to avoid possible negative effects on the environment and public health
and promotes reuse and/or recycling of the materials used to make the equipment.
ENGLISH

META Wired Motor Controller 7 is an “in wall device”, for the multilevel control of
roller shutter motors. It can accurately control the opening and closing of blinds,
curtains, shutters, venetian blinds as requested by the user through local commands
or remotely using computers, smartphones, tablets. At the same time, it is completely
congurable so that it can adapt to the most varied customers’ needs, while being
ready for use without needing additional congurations in order to operate. After
an initial calibration procedure, thanks to a proprietary algorithm, the device is able
to identify the exact position of the roller shutter without using external sensors.
During the operation, a continuous and automatic control of the limit switches allows
maintaining the calibration. In the absence of a power source, the system runs a self-
repositioning procedure that restores calibration. The device is equipped with contact
protection technology (Zero Crossing) which reduces the electrical stress on the relay
contacts and ensures a longer life. The open / closed switching of the device always
occur when the instantaneous value of voltage is 0. It operates in any Z-Wave™
network with other Z-Wave™/Z-Wave Plus™ certied devices and controllers from
any other manufacturer. As a constantly powered node, the device will act as repeater
regardless of the vendor in order to increase the reliability of the network. This device
is a security enabled Z-Wave Plus™ product that is able to use encrypted Z-Wave
Plus™ messages to communicate to other security enabled Z-Wave Plus™ products.
This device must be used in conjunction with a Security Enabled Z-Wave™ Controller
in order to fully utilize all implemented functions.
Integrated Button 1 or 3 clicks to enter in Learn Mode
6 clicks to reset the system to manufacturer’s settings
2 clicks to enter in setup mode
Power Supply 1 – Null
6 – Line
Open/Close Buttons
2, 3
Motor Contacts 4, 5
4
DEVICE DESCRIPTION
Integrated Button
with LED indicator
ENGLISH

TECHNICAL SPECIFICATIONS
SAFETY INFORMATION
Power supply 110 - 230 VAC ± 10% 50/60 Hz
Maximum Load 1200 Watt
System temperature limitation 105 °C
Work temperature From -10° to 40° C
Power consumption < 230 mW in standby mode
< 500 mW when motor is moving
Radio frequency 868.4 MHz
Protection system S2 Security
Maximum distance Up to 100 m outdoor
Up to 40 m indoor
Dimensions 37x37x17 mm
Actuator element Relay
Compliance CE, RoHs
Electrical IP Rating IP20
5
INFO: The device is designed to be installed in ush mounting junction boxes or
close to the motor to be controlled.
WARNING: The device must be installed by electricians qualied to intervene
on electrical systems in compliance with safety requirements set out by the
regulations in force.
DANGER: The device must be connected with a voltage of 230 VAC, before
carrying out any operation, please make sure the power main switch is in OFF
position.
DANGER: Any procedure requiring the use of the Integrated Button is related
only to the installation phase and is to be considered a service procedure that
must be performed by qualied personnel. This operation must be performed
with all necessary precautions for operating in areas with a single level of
insulation.
WARNING: Do not connect loads that exceed the maximum load permitted by
the actuator element.
WARNING: All connections must be performed according to the electrical
diagrams provided.
WARNING: The device must be installed in norm-compliant systems suitably
protected from overloads and short circuits.
ENGLISH

The device must be supplied by 230 AC Power Supply.
Connections must be done following one of the diagrams below:
ELECTRICAL CONNECTIONS DIAGRAM
6
WARNING: The power line must be opportunely protected from short-circuits
and excess load due to a potential motor malfunction.
Power Supply 1 – Null
6 – Line
Commands Switch 2, 3
Motor terminals 4, 5
ENGLISH
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
M
N
L
1) Neutral; 6) Phase; 4, 5) Motor terminals; 2, 3) Commands switch

7
1) Make sure the main switch is set to the OFF position
2) Connect the device based on the diagrams provided
3) Turn the main switch to the ON position
4) If necessary, calibrate the motor limit switches (see motor manufacturer’s manual)
5) Include the device in the Z-WaveTM network
DEVICE INSTALLATION
LED STATUS INDICATOR
TIP: The antenna must not be shortened, removed or
modied. To ensure maximum efciency, it must be
installed as shown. Large size metal equipment near the
antenna can negatively affect reception. Each device is a node
in a mesh network. If there are metal obstacles, the obstacle
can often be overcome with a further triangulation node.
The system includes an RGB LED that shows the device’s status during installation:
Solid RED: the device is not included in any network
Solid BLUE: the device is Ofine setup mode
Blink BLUE: calibration
4 GREEN blinks then OFF: the device has been just added to a Z-WaveTM network in
S2 Authenticate Mode
4 BLUE blinks then OFF: the device has been just added to a Z-WaveTM network in S2
Unauthenticated Mode
4 RED blinks then OFF: the device has been just added to a Z-WaveTM network without
security
Sequence of GREEN-BLUE Learn Mode for inclusion
Sequence of RED-BLUE Learn Mode for exclusion
Rapid sequence of GREEN-BLUE-RED: the event on the input (external switch) is not
valid.
TIP: To test if the electrical connections are correct, before the inclusion of the
device, while pressing ntimes the external switch, the RGB LED should ash
green for the same amount of times. If it does not, check the wire connections.
ENGLISH

8
ADD/REMOVE THE DEVICE INTO A Z-WAVETM NETWORK
(classic)
Standard Inclusion (add)
All META Serie 7 devices are compatible with all Z-WaveTM/Z-Wave PlusTM certied
controllers. The devices support both the
Network Wide Inclusion
mechanism (which
offers the ability to be included in a network, even if the device is not directly connected
to the controller) and
Normal Inclusion
.
By default, the inclusion procedure starts in
Normal Inclusion
mode and after a short
timeout the procedure continues in
Network Wide Inclusion
mode that lasts for about
20 Seconds.
Only a controller can add the device into the network. After activating the inclusion
function by the controller, the device can be added by setting it in
Learn Mode
.
Before including the device, the LED status indicator is solid RED. The adding of a
device is executed by activating the adding procedure in the inclusion section of the
controller interface and then executing 1 or 3 click on the integrated button (the device
is set in
Learn Mode
). As soon as the inclusion procedure initiates the LED indicator
starts a sequence of GREEN-BLUE blinks. The device is included in the network when
the LED status is OFF and the interview is completed.
Standard exclusion (remove)
Only a controller can remove the device from the network. After activating the exclusion
function by the controller, the device can be removed by setting it in
Learn Mode
.
The procedure of exclusion can be activated by Removing a node from the Z-WaveTM
network and executing 1 or 3 click on the integrated button; as soon as the exclusion
initiates, the LED indicator starts a sequence of RED-BLUE blinks. The device is excluded
from the network when the LED status indicator is solid RED and the App_status in the
interface is OK.
ENGLISH

9
SMARTSTART INCLUSION
Z-WaveTM SmartStart aims to shift the tasks related to inclusion of an end device into a
Z-WaveTM network away from the end device itself, and towards the more user-friendly
interface of the gateway.
Z-WaveTM SmartStart removes the need for initiating the end device to start inclusion.
Inclusion is initiated automatically on power-ON and repeated at dynamic intervals
for as long as the device is not included into a Z-WaveTM network. As the new device
announces itself on power-ON, the protocol will provide notications, and the
gateway can initiate the inclusion process in the background, without the need for user
interaction or any interruption of normal operation. The SmartStart inclusion process
only includes authenticated devices.
META Serie 7 devices can be added into a Z-WaveTM network by scanning the Z-WaveTM
QR Code present on the product with a controller providing SmartStart inclusion. No
further action is required and the SmartStart product will be added automatically
within 10 minutes of being switched on in the network vicinity.
The SmartStart QR and the full DSK string code can be found on the back of the device.
The PIN is the rst group of 5 digits printed underlined. If you plan to use the DSK, it is
important that you take a picture of the label and keep it in a safe place.
S2 SECURE INCLUSION
When adding META Serie 7 devices to a Z-WaveTM network with a controller supporting
Security 2 Authenticated (S2), the PIN code of the Z-WaveTM Device Specic Key (DSK) is
required. The unique DSK code is printed on the product label. The rst ve digits of the
key are highlighted and underlined to help the user identify the PIN code.
Pin Code
ENGLISH

10
SUPPORTED COMMAND CLASSES
Command Class
Version Non-Secure
CC
Secure CC
BASIC 2
x
ZWAVEPLUS_INFO 2
x
INDICATOR 2
X
ASSOCIATION 2
x
MULTI_CHANNEL_ASSOCIATION 3
x
ASSOCIATION_GRP_INFO 2
x
TRANSPORT_SERVICE 1
x
VERSION 2
x
MANUFACTURER_SPECIFIC 2
x
POWERLEVEL 1
x
CONFIGURATION 4
x
SECURITY_2 1
x
SUPERVISION
1x
FIRMWARE_UPDATE_MD
5x
WINDOW_COVERING 1
x
MULTILEVEL 4
x
NOTIFICATION 9
x
ENGLISH

Supporting Command Class Basic
The basic command classes are mapped into the Switch Multilevel Command Class.
Supporting Command Class Indicator
The device supports the Command Class Indicator V3 (ID 0x50). When the device
receives an indicator set, the led blinks accordingly to the Indicator set received.
The color shown by the indicator will be:
RED: if the device is included without Security
BLUE: if the device is included in S2 Unauthenticated Mode
GREEN: if the device is already included in S2 Authenticated Mode.
Basic Command received Commando Mappato (multilevel Switch)
Basic Set (0xFF) Multilevel Switch (0xFF)
Basic Set (0x00) Multilevel Switch (0x00)
Basic Set (1, 0x63)
Multilevel Switch (1, 0x63)
Basic GET Basic Report (Current Value, Target Value, Duration)
Current Value and Target Value MUST be set to 0xFE if
not position aware
ENGLISH
11

12
DEVICE CONTROL
META Wired Motor Controller 7 is an “in wall device”, for the multilevel control of
roller shutter motors. It can accurately control the opening and closing of blinds,
curtains, shutters, venetian blinds by using an external switch, or from remote through
a controller.
Controlling the device by External Switches
For the operation of the device within the Z-WaveTM network and controlling the loads
connected to the device, control actions are performed on the external switches.
Event Type of switch
Actions on the switch
Click
Double command button:
UP/DOWN, open/close,
ON/OFF
Press briey & Release
(when pressed it autonomously
returns to the initial position)
MultiClick=nclick Sequence of consecutive nclicks
Hold Down
Press longer than click.
After a Hold Down always follows
an UP event.
Up
Release.
The event applies only if there has
been a previous Hold Down event.
ENGLISH
The CONTROL ACTIONS are EVENTS executed on EXTERNAL SWITCHES
connected to the UP and DOWN terminal of the device which can be
Clicks,
Hold
Down and Up
.
Device status: ON/OFF/STOP, Open/Close/Stop refers to the fact that the motor
is rotating towards the direction Open/Close or it is stopped.
Result of Control Actions
• Holding down the UP/DOWN button makes the motor move in the relevant direction
and stops it as soon as the button is released (Up event) or the shutter reaches its limit
switch.
• A click ordering an UP/DOWN movement while the motor is moving in opposite
direction, will stop the motor.
• A click ordering an UP/DOWN movement while the motor is moving in the same
direction, will be ignored.
• A single click on the UP/DOWN button makes the motor move until it reaches the limit
switch for UP/DOWN position.
• A double click on the UP/DOWN button makes the motor move until it reaches the
favorite position set for the UP/DOWN position.

Controlling the device by a Z-WaveTM controller
The device can be controlled by any Z-WaveTM / Z-Wave PlusTM certied controller
available in the market.
In the gure below, are represented a couple of examples of control panel interfaces
that show how the device will appear once included into the Gateway.
13
ENGLISH
By moving the cursor in the scrollbar is possible to regulate the opening level of the
shutter.
ASSOCIATIONS
META Wired Motor Controller 7 can control other devices like other relays or dimmers.
The device supports 1 association group, which supports the association of up to 8
devices (nodes):
Group
ID
Group
Name
N° of max
nodes sup-
ported in
the group
Description
Command sent
1Lifeline 8
Lifeline Group. Nodes
belonging to this group
will receive: notica-
tions about device reset;
changes related to the
shutter status and Indica-
tor Status.
DEVICE_RESET_LOCALLY_
NOTIFICATION
WIDOM COVERING
REPORT
MULTILEVEL REPORT
INDICATOR_REPORT
INFO: Association ensures direct transfer of control commands between devices
and is performed without participation of the main controller.

14
FIRMWARE UPDATE
RESET TO THE FACTORY SETTINGS
The system supports over-the-air rmware updates that do not require the device to
be removed from its location. The rmware update can be activated from all certied
controllers supporting version 2 of the Firmware Update function.
The device can be reset to the original factory with 6 consecutive clicks on the integrated
button.
After the reset is completed, the device will reboot and a RED solid led is showed.
Please use this procedure only when the network primary controller is missing or
otherwise inoperable.
INFO: If the reset is performed while the device is still part of a network, it
noties the other devices that it has been removed
(Device Reset Locally
Notication).
WARNING: The system will be rebooted at the end of the rmware update
procedure. It is advisable to carry out the rmware update procedure only when
necessary and following careful planning of the intervention.
ENGLISH

15
OFFLINE SETUP MODE
The device has a unique feature that allows to congure some parameters without using
any user interface. This feature enables the professional user to setup the main features
of the device in the eld even if the device is not included in a Z-WaveTM Network. When
the device will be included in the network all these conguration parameters will be
maintained.
To enter in ofine setup mode, operate 2 clicks on the integrated button.
When the device is in Ofine setup mode the led becomes solid Blue and the following
congurations are permitted:
1 click Invert the movement of the motor. Equivalent to set parameter
n. 61 to 1.
2 clicks Reset calibration. Equivalent to set parameter n. 20 to 0.
3 clicks
This conguration will apply only if the calibration is completed.
Set “ON-OFF favorite Level”. The current level will be set as ON_
FAVORITE_LEVEL if the current level is greater than 49 or will be
set to OFF_FAVORITE_LEVEL if the current level is smaller than 50.
If you want to set both ON and Off favorite Level you have to carry
on this setup two times:
One time for the ON position by moving the motor in the chosen
ON_FAVORITE_LEVEL; and a second time for the chosen OFF_
FAVORITE_LEVEL.
After receiving the command the led blinks a number of times equal to the number of
clicks recognized.
6 clicks Exit from Ofine setup mode and return to normal operation.
Hold down for 5
seconds
Reset all conguration parameters to their default value and
return to normal operation.
After entering in Ofine setup mode, the device returns to normal operation if no action
on the switch is detected for more than 20 Seconds.
ENGLISH

16
CONFIGURATIONS
Favorite positions
Parameter
Number Size Parameter
Name
Default
Value Description
2 1
ON_
FAVORITE_
LEVEL
80 The On level reached when the Up
Button received a double click.
Parameters Values Min: 50 Max: 99
Value Description
50-99 50-99% opening level (99% correspond to completely open)
Parameter
Number Size Parameter
Name
Default
Value Description
3 1
ON_
FAVORITE_
LEVEL
20 The Off level reached when the Down
Button received a double click.
Parameters Values Min: 0 Max: 49
Value Description
0-49 0-49% opening level (0 correspond to completely closed)
The system can set two favorite positions: one for the upward movements (opening
movements) Favorite level for ON position, the other for the downward movements
(closing movements) Favorite level for OFF position.
ENGLISH

17
Calibration
Denes the status of the calibration procedure. By default, the calibration starts in
automatic mode as soon as a movement command has been set by external switch or
by Z-Wave™ network.
Afterwards the calibration can be done again by setting this parameter to 20 to 0 or
using the ofine setup mode.
The calibration procedure can be made manually by setting the time needed to
complete a full movement from complete close to complete open and vice versa. The
procedure can be carried on by setting parameter 20 to 1 and parameter 21 and 22, to
the appropriate time in millisecond.
During the calibration, the LED indicator blinks repeatedly in BLUE.
Parameter
Number Size Parameter
Name
Default
Value Description
20 1
CALIBRA-
TION_COM-
PLETE
0Dene if the device has been calibrated.
Parameters Values Min: 0 Max: 1
Value Description
0 TO_BE_DONE (Calibration to be done)
1 DONE (Calibration has been done)
Parameter
Number Size Parameter
Name
Default
Value Description
21 4
MAX_
LEVEL_
TIME
100
Time to reach Max level starting from
the Min Level.
Denes the time in thousandth of a se-
cond necessary to reach the complete
open position starting from complete
close position.
Parameters Values Min: 100 Max: 100.000
Value Description
100-100.000
Time expressed in thousandths of a second
ENGLISH

18
Parameter
Number Size Parameter
Name
Default
Value Description
22 4
MIN_
LEVEL_
TIME
100
Time to reach Min level starting from the
Max Level.
Denes the time thousandth of a second
necessary to reach the complete close
position starting from complete open
position.
Parameters Values Min: 100 Max: 100.000
Value Description
100-100.000
Time expressed in thousandths of a second
Parameter
Number Size Parameter
Name
Default
Value Description
23 4 INVERTION_
TIMEOUT 1000
Time in thousandth of a second after
which the movement direction can be
changed.
Parameters Values Min: 1000 Max: 10.000
Value Description
1000-10.000
Time expressed in thousandths of a second
Parameter
Number Size Parameter
Name
Default
Value Description
24 4
LIMIT_
SWITCH_
TIMEOUT
3000
Time in thousandth of a second for
recognizing that the limit switch has
been reached.
Parameters Values Min: 1000 Max: 10.000
Value Description
1000-10.000
Time expressed in thousandths of a second
ENGLISH

19
ITALIANO
Parameter
Number Size Parameter
Name
Default
Value Description
25 1
FINE_
CALIBRA-
TION
100
Adjustment in Percentage value of the
50% level position after the initial ca-
libration. Increasing/decreasing of this
value will move the 50% level in the UP
direction/Down direction,
Parameters Values Min: 90 Max: 110
Value Description
90-110 Expressed in percentage
Parameter
Number Size Parameter
Name
Default
Value Description
37 4 REPORT_
FREQUENCY 5
Time in seconds after which the new po-
sition report is sent if the target position
is not reached. When the target position
has been reached a nal position report
is sent.
Parameters Values Min: 1 Max: 100
Value Description
1-100 Time expressed in second
Parameter
Number Size Parameter
Name
Default
Value Description
38 4
SEND_
MULTILE-
VEL_
REPORT
0Dene if the Multilevel Report will be
sent unsolicited.
Parameters Values Min: 0 Max: 1
Value Description
0 Only Windom Covering report will be sent
1 Both WiDom Covering and Multilevel Report will be sent
Report Conguration
ENGLISH

20
Other parameters
Parameter
Number Size Parameter
Name
Default
Value Description
61 1 INVERT_
MOVEMENT 0
Movement inversion.
If after the calibration, the movement of
the motor is opposite to the command
issue (goes up, if it is required to go
down and vice versa) the movement can
be inverted.
This parameter can be set also using the
ofine setup mode.
Parameters Values Min: 0 Max: 1
Value Description
0 NOT_INVERTED
1 INVERTED
ENGLISH
Table of contents
Other CHERUBINI Controllers manuals
Popular Controllers manuals by other brands

Shure
Shure AD600 user manual

YOKOGAWA
YOKOGAWA CX2000 Installation and connection guide

Minarik
Minarik MM23001C quick start guide

tousek
tousek ST 80 Installation and connection manual

Chamberlain
Chamberlain LiftMaster Professional CB224 Instructions and electrical set up

Resol
Resol DeltaSol BS Plus manual