SAFETY INSTRUCTIONS
- Only professional technicians must perform installation, complying
with all safety instructions, especially those regarding electrical
connections.
- To avoid short circuits, arrange an automatic bipolar switch with
opening distance of the contacts of at least 3 mm before the circuit.
- The MyRoll control unit was explicitly designed to be installed in
a junction box or socket boxes. Is not waterproof and has a ligh
impact protection. Do not instal the control unit without adequate
protections.
- Do not open or perforate the control unit box.
ELECTRICAL CONNECTIONS
14
L1 N
CL1 N
2 switches
optional
control
M
1- Browm
2- Blue
3- Black
2 2
31 1
3
1
12
GB

15
GB
UP
DOWN
LED
STOP
COMPATIBLE REMOTE CONTROLS
GIRO GIRO Wall
DISPLAY
Change
channel +
Change
channel -
UP
STOP
DOWN
A
B
C
GIRO Plus LED DISPLAY
GIRO Lux
Activating the
Sun sensor
Deactivating the Sun sensor
Sun sensor is “ON”
Wind sensor
is “ON”
GIRO P-LuxDISPLAY
Change channel
Activating/ Deactivating
the Sun sensor
Wind sensor
is “ON”
Sun sensor is
“ON”
To prevent accidental changes to the programming of the motor during the daily use of the
remote control, the possibility of programming is disabled automatically 8 hours after sending
the last sequence (A+B or B+C).
display -
Activating/ Deactivating the
Sun sensor -
Channel selector
LED -
Check the specic instruction book

KEY TO SYMBOLS
GIRO
DOWN
STOP
UP
A
B
C
A
B
C
short motor
rotation in one
direction
long motor rotation
in other direction
double short
rotation
DOWN
UP
Press button A Press buttons A and B
at the same time
TECHNICAL FEATURES
- Power supply 230 V / 50 Hz
- Radio frequency 433,92 MHz
- Decoder system Rolling code
- Modulation AM/ASK
- Max. number storable transmitters 15
- Max motor power 500 W
- Operating temperature -10°C +55°C
- Dimensions 48,5 x 48,5 x 22 mm
- Weight 30 g
16
GB
DOWN
UP

COMMAND SEQUENCES EXAMPLE
Most of the command sequences have three distinct steps, at the
end of which the motor indicates if the step has been concluded
positively or not, by turning in different ways. This section is provided
to demonstrate the motor indications.
The buttons must be pressed as shown in the sequence, without
taking more than 4 seconds between one step and the next.
If more than 4 seconds are taken, the command is not accepted and
the sequence must be repeated.
Command sequence example:
As we can see from the example, when the sequence ends positively,
the motor returns to its starting position in one long rotation. In fact,
two short rotations in the same direction correspond to one long
rotation in the opposite direction. The motor returns to the starting
position even when the sequence is not completed; in this case by
performing one or two short rotations.
Example of a wrong sequence:
Step 1
Step 1 Step 2
> 4 sec repeat the
sequence
repeat the
sequence
> 4 sec
Step 3Step 2Step 1
17
GB

SETTING THE FIRST REMOTE CONTROL
This operation can only be performed when the control unit is new, or
after a total delete of the memory.
T1: First remote control to be set
During this step, power up only one control unit at time!
T1T1 T1 (2 sec)
SETTING THE ROTATION DIRECTION OF THE MOTOR
This operation is mandatory if the rotation direction of the motor does
not match to the UP and DOWN functions of the remote control as an
exemple when giving the ascent command the rolling shutter/awning
descends.
Setting the rotation direction using the button RESET/AUX:
The rotation direction can be reversed also by interchanging the
BROWN motor wire with the BLACK motor wire.
The control unit will keep this setting even after complete
memory clearing!!
SETTING OF ADDITIONAL REMOTE CONTROLS
Up to 15 remote controls can be set.
Tn: Already programmed remote control
Tx: Additional remote control
TnTn Tx (2 sec)
18
GB
max 2 sec
RESET/AUX

REMOTE CONTROL MEMORY CLEARING
It is possible to delete each memorized remote control individually.As
the last one is deleted the control unit initial condition is restored.The
same applies to the single channels of a multichannel remote control:
just select the channel to cancel.
Tn: Remote control to be cleared
TnTn Tn (2 sec)
FULL MEMORY CLEARING
The full memory clearing can be performed in two ways:
1) WITH THE REMOTE CONTROL
Tn: Already programmed remote control
I
Tn (4 sec)
2) WITH THE BUTTON RESET/AUX:
TnTn
19
GB
(8 sec)
RESET/AUX

TIME-OUT SETTING
Time-out is the time during which the
control unit is active, from when an opening
or closing order is given. This time must
always be longer than the opening-closing
time of the device being controlled. The
time-out ends after pressing the STOP
button or also after the time set.
From factory setting: 90 seconds. 2 sec
180 s
45 s
90 s
The control unit will keep this setting even after complete
memory clearing!
SWITCH
It is possible to run the motor through a switch connected to the
control unit with a wire (Optional switch).
The switch must be equipped with mechanical or electrical
interlock, to prevent two commands being sent simultaneously.
Furthermore, the switch must be an unstable pushbutton:
releasing it, the switch opens.
20
GB
OPERATION
Pressing one of the two buttons and releasing,
the motor drives to the desired direction until it
reaches the limits.
To stop the motor before
reaching the limits press
again the same button.
If during the movement
the other button is pressed
the motor changes the
direction.
STOP

21
GB
COMPATIBLE DEVICES
It detects movements caused by the wind on the awning arms.
MISTRAL SENSOR
SETTING THE SENSOR
To associate the sensor to the control unit, a remote control must be
already memorized. Set the sensor selector to the 0 position and then
perform this sequence:
set
2 sec
SELECTOR
LED
SET BUTTON
MISTRAL
cod. A520012
NB: During the wind-alarm the led inside the MyRoll blinks.
I
For the complete description of the functions of this device see the
instruction booklet that came in the box.
DELETING THE SENSOR
To delete the sensor from the control unit, an already programmed
remote control must be used.
Set the sensor selector to the 0 position
, if active wait for the sensor to
go off and then perform this sequence:
set
2 sec

22
GB
Power Supply 230 Vac
Sensor
element
RUGIADA (TX RAIN-SENSOR)
ANEMOMETERS
WINDTEC - Ref. A520007
WINDTEC LUX - Ref. A520008
Sun-sensor
tuning
Set button
Wind-speed
tuning
set
Set button
set
RUGIADA - Ref. A520016
For the complete description of the functions of these devices see the
instruction booklet that came in the box.
SETTING
To associate the sensor to the control unit, a remote control must be
already memorised. The setting sequence is the following:
DELETING
To delete the sensor from the control unit, an already programmed
remote control must be used. The deleting sequence is the following:
set
2 sec
set
2 sec
NB: During the wind-alarm the led inside the MyRoll blinks.

23
GB
ENABLE / DISABLE THE SUN SENSOR
(WindTec Lux)
To enable (automatically) or disable (manually) the sun sensor
refer to the instruction manual provided with the sensor or the
remote control you want to use.
WINDTEC/WINDTEC LUX TEST MODE
This function is useful to check proper radio communications and to
perform the wind and sun function test.
To activate the TEST function, hold the SET button down for around 2
seconds, until the awning opens for 10 seconds and closes briey to
conrm that the test has been activated. The Test function lasts for 3
minutes, during which the wind and sunlight threshold settings can
be checked, without waiting for activation times. After 3 minutes, the
WindTec sensor returns to normal operational mode.
During the test mode the led inside the MyRoll is on.
WIND FUNCTION TEST (WINDTEC, WINDTEC LUX)
To avoid errors during the wind function test, it is suggested that the
sunlight function be deactivated. By spinning the anemometer ns,
when the speed detected by the sensor exceeds the threshold set, the
motor commands the closing of the awning.
SUN FUNCTION TEST (WINDTEC LUX)
Make sure that the sunlight function is on. When the sensor detects a
change in the sunlight intensity, it opens the awning if the sunlight
intensity goes above the threshold set, or it closes the awning if the
light intensity goes below the threshold set. It is possible to repeat this
test several times, so as to nd the desired adjustment levels
precisely.
2 sec
set

SHORT-TERM SETTING OF A REMOTE CONTROL
This function makes it possible to store a remote control temporarily,
for example, with the purpose of setting the limit switches during
assembly in the factory. A later nal saving of the remote control will
be possible using the appropriate command sequence (see: “SETTING
THE FIRST REMOTE CONTROL”).
The operations described below can be carried out only when the
control unit has just come out of the factory or after a full memory
clearing (see: “FULL MEMORY CLEARING”).
The control unit makes the following operations possible only within
the time limits described in order to make sure that the short-term
setting is used only in the installation or factory setting phase and not
during daily use. Power up the control unit, make sure that no other
control units having an empty memory are powered up in the same
operating range.
Within 30 seconds after start, press the B and C buttons
simultaneously until the motor gives a conrmation signal.
The remote control will remain stored for 5 minutes, while the
control unit is powered up. After 5 minutes or when the control unit
has its power cut off, the remote control will be cancelled.
T1: First remote control to be stored
24
GB
T1
CHERUBINI S.p.A. declares that the product is in conformity with
the relevant Union harmonisation legislation:
Directive 2014/53/EU, Directive 2011/65/EU.
The full text of the EU declaration of conformity is available upon
request at the following website: www.cherubini.it.
EU DECLARATION OF CONFORMITY



I
D
F
E
CHERUBINI Deutschland GmbH
Siemensstrasse, 40 - 53121 Bonn - Deutschland
Tel. +49 (0) 228 962 976 34 / 35 | Fax +49 (0) 228 962 976 36
info@cherubini-group.de | www.cherubini-group.de
CHERUBINI France S.a.r.l.
ZI Du Mas Barbet
165 Impasse Ampère
30600 Vauvert -France
Tél. +33 (0) 466 77 88 58 | Fax +33 (0) 466 77 92 32
info@cherubini.fr | www.cherubini.fr
CHERUBINI Iberia S.L.
Avda. Unión Europea 11-H
Apdo. 283 - P. I. El Castillo
03630 Sax Alicante - Spain
Tel. +34 (0) 966 967 504 | Fax +34 (0) 966 967 505
info@cherubini.es | www.cherubini.es
CHERUBINI S.p.A.
Via Adige 55
25081 Bedizzole (BS) - Italy
Tel. +39 030 6872.039 | Fax +39 030 6872.040
info@cherubini.it | www.cherubini.it
Rev: 1 11/2019 - Cod: A4518_6L42
This manual suits for next models
1
Table of contents
Other CHERUBINI Controllers manuals