CHERUBINI WiDom Smart Roller Shutter 7 User manual

EN English
OPERATING INSTRUCTIONS
PRODUCT CODE
PRODUCT VARIANT
UMS700
Standard
RXMC700
RX (white wire)
1 2 3 4 5 6
Smart Roller Shutter 7

Smart Roller Shutter 7 - Operating Instructions II
Revision History
Content
Revision History..............................................................................................................................................................II
Device description..........................................................................................................................................................1
Technical Specifications..............................................................................................................................................2
Safety information .....................................................................................................................................................2
Electrical Connections diagram.......................................................................................................................................3
Device Installation..........................................................................................................................................................4
LED status indicator........................................................................................................................................................4
Add/Remove the device into a Z-Wave™network (classic).............................................................................................4
SmartStart Inclusion .......................................................................................................................................................5
S2 Secure inclusion.........................................................................................................................................................5
Supported Command Classes .........................................................................................................................................6
Supporting Command Class Basic...............................................................................................................................6
Supporting Command Class Indicator.........................................................................................................................6
Device Control................................................................................................................................................................7
Controlling the device by External Switches ...............................................................................................................7
Controlling the device by a Z-Wave™controller .........................................................................................................8
Associations ...................................................................................................................................................................8
Reset to the factory settings...........................................................................................................................................8
Firmware Update ...........................................................................................................................................................9
Offline setup Mode ........................................................................................................................................................9
Configurations..............................................................................................................................................................10
Favorite positions.....................................................................................................................................................10
Calibration ...............................................................................................................................................................10
Report Configuration................................................................................................................................................12
Other parameters ....................................................................................................................................................12
Disposing the devices ...................................................................................................................................................13
Rev. Doc.
Date
Page
Description
0
30/06/2022
Initial version
1
29/09/2022
Update of the Association section
2
21/10/2022
Parameter 38 has been removed
Parameter 37: size has been changed to 1
Supported Command Classes paragraph has been updated
3
07/12/2022
Electrical connection diagram (added RX variant)
4
02/02/2023
Integrated Max transmitted power update

Smart Roller Shutter 7 - Operating Instructions III
Compliance with directives...........................................................................................................................................13
Warranty......................................................................................................................................................................13
Legal Notes...................................................................................................................................................................13

Smart Roller Shutter 7 - Operating Instructions 1
Device description
Smart Roller Shutter 7 is an "in wall device", for the multilevel control of roller shutter motors. It can accurately control
the opening and closing of blinds, curtains, shutters, venetian blinds as requested by the user through local commands
or remotely using computers, smartphones, tablets.
At the same time, it is completely configurable so that it can adapt to the most varied customers’ needs, while being
ready for use without needing additional configurations in order to operate.
After an initial calibration procedure, thanks to a proprietary algorithm, the device is able to identify the exact position
of the roller shutter without using external sensors. During the operation, a continuous and automatic control of the
limit switches allows maintaining the calibration. In the absence of a power source, the system runs a self-repositioning
procedure that restores calibration.
The device is equipped with contact protection technology (Zero Crossing) which reduces the electrical stress on the
relay contacts and ensures a longer life. The open / closed switching of the device always occur when the instantaneous
value of voltage is 0.
It operates in any Z-Wave™network with other Z-Wave™/Z-Wave Plus™certified devices and controllers from any
other manufacturer. As a constantly powered node, the device will act as repeater regardless of the vendor in order to
increase the reliability of the network.
This device is a security enabled Z-Wave Plus™product that is able to use encrypted Z-Wave Plus™messages to
communicate to other security enabled Z-Wave Plus™products.
This device must be used in conjunction with a Security Enabled Z-Wave™Controller in order to fully utilize all
implemented functions.
Integrated Button
1 or 3 clicks to enter in Learn Mode
6 clicks to reset the system to manufacturer's settings
2 clicks to enter in Offline setup mode
Power Supply
1 –Null
6 - Line
Open/Close Buttons
2, 3
Motor Contacts
4, 5
1 2 3 4 5 6
Integrated Button
with LED indicator

Smart Roller Shutter 7 - Operating Instructions 2
Technical Specifications
Power supply
110 - 230 VAC±10% 50/60 Hz
Maximum Load
1200 Watt
System temperature limitation
105°C
Work temperature
From -10° to 40° C
Power consumption
< 230 mW in standby mode
< 500 mW when motor is moving
Radio frequency
868.4 MHz
Maximum transmitted power
5 dBm
Protection system
S2 Security
Maximum distance
Up to 100 m outdoor
Up to 40 m indoor
Dimensions
37x37x17 mm
Actuator element
Relay
Compliance
CE, RoHs
Electrical IP Rating
IP20
Safety information
INFO: The device is designed to be installed in flush mounting junction boxes or close to the motor to be
controlled.
WARNING: The device must be installed by electricians qualified to intervene on electrical systems in compliance
with safety requirements set out by the regulations in force.
DANGER The device must be connected with a voltage of 230 VAC, before carrying out any operation, please
make sure the power main switch is in OFF position.
DANGER: Any procedure requiring the use of the Integrated Button is related only to the installation phase and
is to be considered a service procedure that must be performed by qualified personnel. This operation must be
performed with all necessary precautions for operating in areas with a single level of insulation.
WARNING: Do not connect loads that exceed the maximum load permitted by the actuator element.
WARNING: All connections must be performed according to the electrical diagrams provided
WARNING: The device must be installed in norm-compliant systems suitably protected from overloads and short
circuits.

Smart Roller Shutter 7 - Operating Instructions 3
Electrical Connections diagram
The device must be supplied by 230 AC Power Supply.
Connections must be done following one of the diagrams below:
Standard Variant
RX Variant
Power Supply: 1 –Null, 6 - Line
Comand Switch: 2, 3
Motor Terminals: 4, 5
Power Supply: 1 –Null, 6 - Line
Comand Switch: 2, 3
Motor Terminals: 4 (white wire), 5
WARNING: The power line must be opportunely protected from short-circuits and excess load due to a potential
motor malfunction.
1 2 3 4 5 6
M
N
L
1 2 3 4 5 6
M
N
L

Smart Roller Shutter 7 - Operating Instructions 4
Device Installation
1) Make sure the main switch is set to the OFF position
2) Connect the device based on the diagrams provided
3) Turn the main switch to the ON position
4) If necessary, calibrate the motor limit switches (see motor manufacturer's manual)
5) Include the device in the Z-Wave™network
TIP: The antenna must not be shortened, removed or modified. To ensure maximum
efficiency, it must be installed as shown. Large size metal equipment near the
antenna can negatively affect reception. Each device is a node in a mesh network. If there
are metal obstacles, the obstacle can often be overcome with a further triangulation node.
LED status indicator
The system includes an RGB LED that shows the device’s status during installation:
Solid RED: the device is not included in any network
Solid BLUE: the device is Offline setup mode state
Blink BLUE: calibration
4 GREEN blinks then OFF: the device has been just added to a Z-Wave™network in S2 Authenticate Mode
4BLUE blinks then OFF: the device has been just added to a Z-Wave™network in S2 Unauthenticated Mode
4RED blinks then OFF: the device has been just added to a Z-Wave™network without security
Sequence of GREEN-BLUE Learn Mode for inclusion
Sequence of RED-BLUE Learn Mode for exclusion
Rapid sequence of GREEN-BLUE-RED: the event on the input (external switch) is not valid
TIP: To test if the electrical connections are correct, before the inclusion of the device, while pressing ntimes the
external switch, the RGB LED should flash green for the same amount of times. If it does not, check the wire
connections.
Add/Remove the device into a Z-Wave™network (classic)
Standard Inclusion (add)
All Smart Serie 7 devices are compatible with all Z-Wave™/Z-Wave Plus™certified controllers. The devices support both
the Network Wide Inclusion mechanism (which offers the ability to be included in a network, even if the device is not
directly connected to the controller) and Normal Inclusion.
By default, the inclusion procedure starts in Normal Inclusion mode and after a short timeout the procedure continues
in Network Wide Inclusion mode that lasts for about 20 Seconds.
Only a controller can add the device into the network. After activating the inclusion function by the controller, the device
can be added by setting it in Learn Mode.
Before including the device, the LED status indicator is solid RED. The adding of a device is executed by activating the
adding procedure in the inclusion section of the controller interface and executing 1 or 3 click on the integrated button
(the device is set in Learn Mode). As soon as the inclusion procedure initiates the LED indicator starts a sequence of
GREEN-BLUE blinks. The device is included in the network when the LED status is OFF and the interview is completed.
1 2 3 4 5 6

Smart Roller Shutter 7 - Operating Instructions 5
Standard exclusion (remove)
Only a controller can remove the device from the network. After activating the exclusion function by the controller, the
device can be removed by setting it in Learn Mode.
The procedure of exclusion can be activated by Removing a node from the Z-Wave™network and executing 1 or 3 click
on the integrated button; as soon as the exclusion initiates, the LED indicator starts a sequence of RED-BLUE blinks. The
device is excluded from the network when the LED status indicator is solid RED and the App_status in the interface
is OK.
SmartStart Inclusion
Z-Wave™SmartStart aims to shift the tasks related to inclusion of an end device into a Z-Wave™network away from
the end device itself, and towards the more user-friendly interface of the gateway.
Z-Wave™SmartStart removes the need for initiating the end device to start inclusion. Inclusion is initiated automatically
on power-ON and repeated at dynamic intervals for as long as the device is not included into a Z-Wave™network. As
the new device announces itself on power-ON, the protocol will provide notifications, and the gateway can initiate the
inclusion process in the background, without the need for user interaction or any interruption of normal operation. The
SmartStart inclusion process only includes authenticated devices.
Smart Serie 7 devices can be added into a Z-Wave™network by scanning the Z-Wave™QR Code present on the product
with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added
automatically within 10 minutes of being switched on in the network vicinity.
The SmartStart QR and the full DSK string code can be found on the back of the device. The PIN is the first group of
5 digits printed underlined. If you plan to use the DSK, it is important that you take a picture of the label and keep it in
a safe place.
S2 Secure inclusion
When adding Smart Serie 7 devices to a Z-Wave™network with a controller supporting Security 2 Authenticated (S2),
the PIN code of the Z-Wave™Device Specific Key (DSK) is required. The unique DSK code is printed on the product label.
The first five digits of the key are highlighted and underlined to help the user identify the PIN code.
Pin Code

Smart Roller Shutter 7 - Operating Instructions 6
Supported Command Classes
Command Class
Version
Non-Secure CC
Secure CC
BASIC
2
x
ZWAVEPLUS_INFO
2
x
ASSOCIATION
2
x
MULTI_CHANNEL_ASSOCIATION
3
x
ASSOCIATION_GRP_INFO
3
x
TRANSPORT_SERVICE
2
x
VERSION
3
x
MANUFACTURER_SPECIFIC
2
x
DEVICE_RESET_LOCALLY
1
x
INDICATOR
3
x
POWERLEVEL
1
x
SECURITY_2
1
x
SUPERVISION
1
x
FIRMWARE_UPDATE_MD
5
x
APPLICATION_STATUS
1
x
CONFIGURATION_V4
4
x
SWITCH_MULTILEVEL
4
x
WINDOW_COVERING
1
x
Supporting Command Class Basic
The basic command classes are mapped into the Switch Multilevel Command Class.
Basic Command received
Mapped Command (multilevel Switch)
Basic Set (0xFF)
Multilevel Switch (0xFF)
Basic Set (0x00)
Multilevel Switch (0x00)
Basic Set (1, 0x63)
Multilevel Switch (1, 0x63)
Basic GET
Basic Report (Current Value, Target Value, Duration) Current Value and Target Value
MUST be set to 0xFE if not position aware
Supporting Command Class Indicator
The device supports the Command Class Indicator V3 (ID 0x50). When the device receives an indicator set, the led blinks
accordingly to the Indicator set received.
The color shown by the indicator will be:
RED: if the device is included without Security
BLUE:if the device is included in S2 Unauthenticated Mode
GREEN:if the device is already included in S2 Authenticated Mode

Smart Roller Shutter 7 - Operating Instructions 7
Device Control
Smart Roller Shutter 7 is an "in wall device", for the multilevel control of roller shutter motors. It can accurately control
the opening and closing of blinds, curtains, shutters, venetian blinds by using an external switch, or from remote through
a controller.
Controlling the device by External Switches
For the operation of the device within the Z-Wave™network and controlling the motors connected to the device, control
actions are performed on the external switches.
The CONTROL ACTIONS are EVENTS executed on EXTERNAL SWITCHES connected to the UP and DOWN
terminal of the device which can be Clicks, Hold Down and Up.
Event
Type of switch
Actions on the switch
Click
Double command button:
UP/DOWN, open/close,
ON/OFF
Press briefly & Release
(when pressed it autonomously returns to the initial position)
MultiClick=nclicks
Sequence of consecutive nclicks
Hold Down
Press longer than click.
After a Hold Down always follows an UP event.
Up
Release.
The event applies only if there has been a previous Hold Down
event.
Device status: ON/OFF/STOP, Open/Close/Stop refers to the fact that the motor is rotating towards the direction
Open/Close or it is stopped.
Result of Control Actions
•Holding down the UP/DOWN button makes the motor move in the relevant direction and stops it as
soon as the button is released (Up event) or the shutter reaches its limit switch.
•A click ordering an UP/DOWN movement while the motor is moving in opposite direction, will stop
the motor.
•A click ordering an UP/DOWN movement while the motor is moving in the same direction, will be
ignored.
•A single click on the UP/DOWN button makes the motor move until it reaches the limit switch for
UP/DOWN position.
•A double click on the UP/DOWN button makes the motor move until it reaches the favorite position
set for the UP/DOWN position.

Smart Roller Shutter 7 - Operating Instructions 8
Controlling the device by a Z-Wave™controller
The device can be controlled by any Z-Wave™/ Z-Wave Plus™certified controller available in the market.
In the figure below, are represented a couple of examples of control panel interfaces that show how the device will
appear once included into the Gateway.
By moving the cursor in the scrollbar is possible to regulate the opening level of the shutter.
Associations
Smart Roller Shutter 7 can control other devices like other relays or dimmers. The device supports 3 association group,
which supports the association of up to 8 devices (nodes):
Group
ID
Group
Name
N° of max
nodes
supported
in the group
Description
Command sent
1
Lifeline
8
Lifeline Group. Nodes belonging to
this group will receive: notifications
about device reset; changes related
to the shutter status and Indicator
Status.
DEVICE_RESET_LOCALLY_NOTIFICAT
ION
WIDOM COVERING REPORT
MULTILEVEL REPORT
INDICATOR_REPORT
2
Follow me
8
Nodes belonging to this group will
receive basic Set Command with the
same level reached by the device
BASIC SET
3
Control by
switch
8
Nodes belonging to this group will be
controlled by the events on the
switch, and the movement of the
controlled device will be in sync with
the controller device
WINDOW_COVERING_SET,
WINDOW_COVERING_STOP_LEVEL_
CHANGE
INFO: Association ensures direct transfer of control commands between devices and is performed without
participation of the main controller.
Reset to the factory settings
The device can be reset to the original factory settings with 6 consecutive clicks on the integrated button.
After the reset is completed, the device will reboot and a RED solid led is showed.
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
INFO: If the reset is performed while the device is still part of a network, it notifies the other devices that it has
been removed (Device Reset Locally Notification).

Smart Roller Shutter 7 - Operating Instructions 9
Firmware Update
The system supports over-the-air firmware updates that do not require the device to be removed from its location. The
firmware update can be activated from all certified controllers supporting version 2 of the Firmware Update function.
WARNING: The system will be rebooted at the end of the firmware update procedure. It is advisable to carry out
the firmware update procedure only when necessary and following careful planning of the intervention.
Offline setup Mode
The device has a unique feature that allows to configure some parameters without using any user interface. This feature
enables the professional user to setup the main features of the device in the field even if the device is not included in a
Z-Wave™Network. When the device will be included in the network all these configuration parameters will be
maintained.
To enter in offline setup mode, operate 2 clicks on the integrated button.
When the device is in Offline setup mode the led becomes solid Blue and the following configurations are permitted:
1 click
Invert the movement of the motor. Equivalent to set parameter n.61 to 1
2 clicks
Reset calibration. Equivalent to set parameter n.20 to 0
3 clicks
This configuration will apply only if the calibration is completed.
Set “ON-OFF favorite Level”. The current level will be set as ON_FAVORITE_LEVEL if
the current level is greater than 49 or will be set to OFF_FAVORITE_LEVEL if the
current level is smaller than 50.
If you want to set both ON and Off favorite Level you have to carry on this setup two
times:
One time for the ON position by moving the motor in the chosen
ON_FAVORITE_LEVEL; and a second time for the chosen OFF_FAVORITE_LEVEL
4 clicks
Set the current level as 50% of the opening range
After receiving the command the led blinks a number of times equal to the number of clicks recognized
6 clicks
Exit from Offline setup mode and return to normal operation
Hold down for 5 seconds
Reset all configuration parameters to their default value and return to normal
operation
After entering in Offline setup mode, the device returns to normal operation if no action on the switch is detected for
more than 20 Seconds.

Smart Roller Shutter 7 - Operating Instructions 10
Configurations
Favorite positions
The system can set two favorite positions: one for the upward movements (opening movements) Favorite level for ON
position, the other for the downward movements (closing movements) Favorite level for OFF position.
Parameter
Number
Size
Parameter Name
Default
Value
Description
2
1
ON_FAVORITE_LEVEL
80
The On level reached when the Up Button received a
double click.
Parameters Values Min: 50 Max: 99
Value
Description
50-99
50-99% opening level (99% correspond to completely open)
Parameter
Number
Size
Parameter Name
Default
Value
Description
3
1
OFF_FAVORITE_LEVEL
20
The Off level reached when the Down Button received a
double click.
Parameters Values Min: 0 Max: 49
Value
Description
0-49
0-49% opening level (0 correspond to completely closed)
Calibration
Defines the status of the calibration procedure. By default, the calibration starts in automatic mode as soon as a
movement command has been set by external switch or by Z-Wave™network.
Afterwards the calibration can be done again by setting the parameter 20 to 0 or by using the offline setup mode.
The calibration procedure can be made manually by setting the time needed to complete a full movement from
complete close to complete open and vice versa. The procedure can be carried on by setting parameter 20 to 1 and
parameter 21 and 22, to the appropriate time in millisecond.
During the calibration, the LED indicator blinks repeatedly in BLUE.
Parameter
Number
Size
Parameter Name
Default Value
Description
20
1
CALIBRATION_COMPLETE
0
Define if the device has been
calibrated.
Parameters Values Min: 0 Max: 1
Value
Description
0
TO_BE_DONE (Calibration to be done)
1
DONE (Calibration has been done)

Smart Roller Shutter 7 - Operating Instructions 11
Parameter
Number
Size
Parameter Name
Default
Value
Description
21
4
MAX_LEVEL_TIME
100
Time to reach Max level starting from the Min Level
Defines the time in thousandth of a second necessary to
reach the complete open position starting from complete
close position.
Parameters Values Min: 100 Max: 100.000
Value
Description
100-100.000
Time expressed in thousandths of a second
Parameter
Number
Size
Parameter Name
Default
Value
Description
22
4
MIN_LEVEL_TIME
100
Time to reach Min level starting from the Max Level
Defines the time thousandth of a second necessary to
reach the complete close position starting from complete
open position.
Parameters Values Min: 100 Max: 100.000
Value
Description
100-100.000
Time expressed in thousandths of a second
Parameter
Number
Size
Parameter Name
Default
Value
Description
23
4
INVERTION_TIMEOUT
500
Time in thousandth of a second after which the
movement direction can be changed.
Parameters Values Min: 500 Max: 3.000
Value
Description
500 - 3.000
Time expressed in thousandths of a second
Parameter
Number
Size
Parameter Name
Default
Value
Description
24
4
LIMIT_SWITCH_TIMEOUT
2500
Time in thousandth of a second for recognizing that
the limit switch has been reached.
Parameters Values Min: 1000 Max: 5.000
Value
Description
1000-5.000
Time expressed in thousandths of a second

Smart Roller Shutter 7 - Operating Instructions 12
Parameter
Number
Size
Parameter Name
Default
Value
Description
25
1
FINE_CALIBRATION
100
Adjustment in Percentage value of the 50% level
position after the initial calibration.
Increasing/decreasing of this value will move the
50% level in the UP direction/Down direction.
Parameters Values Min: 50 Max: 150
Value
Description
50-150
Expressed in percentage
Report Configuration
Parameter
Number
Size
Parameter Name
Default
Value
Description
37
1
REPORT_FREQUENCY
5
Time in seconds after which the new position
report is sent if the target position is not
reached. When the target position has been
reached a final position report is sent.
Parameters Values Min: 1 Max: 100
Value
Description
1-100
Time expressed in second
Other parameters
Parameter
Number
Size
Parameter Name
Default
Value
Description
61
1
INVERT_MOVEMENT
0
Movement inversion
If after the calibration, the movement of the motor is
opposite to the command issue (goes up, if it is required
to go down and vice versa) the movement can be
inverted.
This parameter can be set also using the offline setup
mode.
Parameters Values Min: 0 Max: 1
Value
Description
0
NOT_INVERTED
1
INVERTED

Smart Roller Shutter 7 - Operating Instructions 13
Disposing the devices
This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE)
and must be handled pursuant to European Directive WEEE in order to be recycled or dismantled to
minimize its impact on the environment.
For further information, please contact your local or regional authorities.
Electronic products not included in the selective sorting process are potentially dangerous for the
environment and human health due to the presence of hazardous substances.
Compliance with directives
WiDom Srl declares that Smart Roller Shutter 7 is built in compliance with directive 2014/53/EU. The complete version
of the Declaration of Conformity is available upon request at the following internet address www.widom.it.
Warranty
For detailed information on the warranty please refer to the Standard Warranty Conditions indicated in company’s
website at www.widom.it.
Please check at www.widom.it the newest version of this document.
Legal Notes
WiDom Srl shall not be held responsible for any damage caused by these devices if they are used in a manner that is not
compliant with the instructions in this manual. WiDom Srl reserves the right to make any changes to the product that it
considers necessary or useful without jeopardizing its primary features, to change characteristics and technical
specifications without notice, and is not responsible for any graphic or typographical errors that that may appear in this
document.
WiDom Srl
Adress: Via Mameli 88 - 09123 - Cagliari (ITALIA)
E-mail: [email protected]
Tel: +39 0702057916
This manual suits for next models
2
Table of contents
Other CHERUBINI Switch manuals