Installation Instructions
1.Product Introduction
This wireless photoelectric fire alarm smoke detector adopts
unique structure design and MCU processing to photoelectric
signal in order to increase the functions of anti dust, insects
and white light interference to guarantee the stability. At the
same time, this detector is with wireless net linkage function
and suitable for different environments installation, which
has greatly increased users' sense for smoke alarm signal.
It is with better response to visible smoke caused by smoldering
and burning so it is suitable for fire alarm protection in
residential area, supermarket, factory, office, school, bank,
library, hotels, warehouse etc. Its functions and stability is
much better than those smoke detectors with similar prices
in the market
-Elegant appearance design
-Stable, safe and reliable
-Adopts super low power consumption processor and
software calculation
-Unique self-check function
-Lower power check and remind
-Anti RFI/EMI interference
-Adopts advanced SMT technology
-Detection range reaches 40㎡ when installed at 2.3-6m;
60㎡ at 6-12m
2.Main functions
3.Technical Parameter
5.Installation And Internal Parts
This detector adopts plastic base direct installation
Power input: 3.6V 1/2AA lithium battery
Current: <10uA (stand by) <20mA(in alarm)
Installation way: ceiling mount
Alarm threshold: 5-25% obs/m
Self check: according to client's requirements(H)
Alarm volume: >85dB (3m ahead)
Alarm period: continuous trigger till smoke disappear
Low voltage alarm triggered: at 2.8V
Wireless distance:≥300m (open space)
Frequency: 315/433MHz etc.
Encoding: Ev1527 or Pt2262
Anti REI/EMI: 1-500MHz/10V/m
Operation temperature : -10℃/+55℃
Operation humidity :95% RH
Dimensions:φ101mm×44mm
6m
4.Installation Guide And Operation Principle
1.When installation height is less than 6m, and
detector is installed on diaphragm, the distance
from lower surface of detector to ceiling can't
be over 0.3m
2.Distance from detector to ventilation hole must
be more than 1.5m when there is air-conditioner
in the room
3.Detector must be installed at 0.6m over the wall
or girder.
Detector's protection range and calculation on how
many detectors should be installed in a space
Can get detection range of 40m² when
installed at the height of 2.3-6m
12m
+ -
Plastic base
Installation
bayonet
Screw hole
Installation
slip hook
Press down TEST button for 0.5 second, buzzer will
send out one “Di” sound and then send out wireless
smoke alarm signal
Keep pressing down the TEST button, buzzer will
send out three “Di, Di, Di” sounds and repeat this
each 1.5 seconds, then red alarm LED keeps on, that
means detector is working well, detector will return
to normal working status after release of TEST button
Optical maze
Fit for installation in:
Residential area, cafe, KTV, hotel, restaurant,
apartment, trattoria etc.
Not suitable for:
place full of dust, powder and plenty vapour;
place that might be with corrosive gas;
kitchen and other place that might with smoke remain;
place with oversized temperature and humidity;
place with ventilation speed over 15m/sec
Detector's detection to smoke can be fulfilled by
optical maze, there are a pair of infrared transmitter
and receiver, their ejection angle is around 120°,
when there is no smoke, receiver can't receive the
infrared light from transmitter, so there will be no
voltage output from following circuit. When there
is smoke, smoke enters the maze and scatters the
infrared light from transmitter. Receiver receives
the scattered infrared light and makes voltage output
at the following circuit, the thicker the smoke is,
the stronger scattering is, and the higher voltage is.
When the voltage reaches preset value, detector
sends out alarm signal and alarm is triggered.
Detector operation principle:
Adjustment
Installation position must satisfy following
requirements:
PUSH TO
TEST WEEKLY
A
NU
A
L
F
M
O
`
S
R
R
E
O
N
P
W
E
R
O
A
T
O
I
N
T
N
R
G
E
F
I
N
E
S
R
T
:
R
T
U
N
C
A
T
T
R
I
O
O
N
P
S
M
I
Buzzer
LED
Test button
Can get detection range of 60m² when
installed at the height of 6-12m
Detector
When target space height is 6-12m, protection
range is 60㎡
Battery cover
Accessories
Buzzer output
Battery input
Battery box
(with bat)
Data set
Transmission
antenna(315M or 433M)
Buzzer
When target space height is below 6m, protection
range is 40㎡
Detection range
Protection area for each detector
Detector quantity=
6.Settings And Operations
Rev .00 18/1
1.LED status:
After connecting of power, red LED will flash for
10 times as self check, then detector enters into
working status
During normal working, green LED flashes for one
time each 60 seconds
When voltage is low, green LED and red LED will
flash at the same time each 30 seconds
During alarm status or test status, red LED keeps on
2.Buzzer hooting status:
Fire alarm warning tone: hasty 3 “Di Di Di” sounds
and repeats each 1.5 seconds
Trouble warning tone: 1 short “Di” sound and repeats
each 25 seconds
Detector trouble warning tone: buzzer sends out
sound each 4 seconds
3.Alarm test function:
Detector enters into normal operation status after
connection with power, green LED flashes for 1 time
each 60 seconds. Press down TEST button, buzzer
sends out alarm sound and red LED keeps on, release
the TEST button and detector resume to normal
working status. ( Strongly suggestion with 1 check
each month)
9.Notes
Suggestions
1.Please change a new battery after real fire alarm
2.Suggest to send detector back to factory for check and maintenance after 1-year operation
3.Suggest to change new detector after 10 years operation
Warning
1.Please don't install detector to space with high temperature or heavy soot and keep surrounding air clean
2.Avoid mass usage of paint or thinners which will produce colloid suspended substance to guarantee detector
normal operation
3.This product is home-use photoelectric smoke detector for fire alarm detection, it can send out sound and
light alert but cannot put out a fire!
4.Fire alarm resume:
When fire alarm is triggered, press down TEST button
for 3 seconds then detector resume to normal operation
status. Or re-connect the power to let detector resume
to normal working.
5.Fire alarm function:
When surrounding smoke thickness reaches preset
value, detector will send out fire alarm signal within
3 seconds and red LED keeps on, buzzer sends out
alarm sound, when keep pressing down TEST button
for 3 seconds, detector resumes to normal detection
status.
6.Low power warning function:
Detector is with low power check function, when
battery voltage is lower than 2.8V, detector sends
out trouble warning sound (short DI sound) and green
and red LED flash at the same time and repeats each
30 seconds.
7.Setting of data jumper:
Proper data codes can be obtained by jumper setting
on “DATA SET”,then control panel can recognize
the codes:D1\D2\D3\D4
Setting of
data jumper
D4
D3
D2
D1
8.Preservation And Maintenance
1.After installation and actual operation, please press down TEST button for normal test weekly, if there is
troubles, please check on time or return back to factory for repairing.
2.Usually battery life can be more than 3 years, but severe environment such as high temperature and humidity
might shorten its operation life time
3.Please change same type battery when detector sends out low power signal as following steps:
1)Push open the battery cover
2)Take down the old battery from battery box
3)Put new battery into the battery box, pay attention to polarity
4)Push back the battery cover
5)When battery change finished, press down TEST button, if there is sound and light alarm, then battery
change is successful
6)Detector should be well protected before actual installation to avoid dust, humidity and corrosion
4.Please don't dismantle detector for self repairing when there is trouble. Contact factory or local commercial
center for fast service.
Data set
L
H
H
L
Low level: jumper pin inserted means low
level (Jumpers come with package)
High level: empty jumper means high level
Test button
Battery cover
PUSH TO
TEST WEEKLY
A
N
U
A
L
F
M
O
`
S
R
R
E
O
N
P
W
E
R
O
A
T
O
I
N
T
N
R
G
E
F
I
N
E
S
R
T
:
R
T
U
N
C
A
T
T
R
I
O
O
N
P
S
M
I
Buzzer
LED
7.Trouble Analysis And Removal
Trouble types
Alarm triggered
after power
connection
Buzzer no sound or
very low sound
when alarm triggered
Reason analysis
Detector in unstable status
Heavy smoke dust or humidity
in the room
Damage in circuit
Battery low power
Damage in buzzer
Trouble removal solution
Press down TEST button for over 3
seconds or re-connect power
Re-connect power after dispelling
of smoke dust and humidity
Return to factory for repairing
Change battery with same type
Return to factory for repairing
Note
Battery poor connection Re-connect battery
No alarm after press
down TEST button Battery low power Change battery with same type

Popular Smoke Alarm manuals by other brands

CALECTRO UNIGUARD SUPERFLOW UG-3-NS-AOS quick start guide

CALECTRO

CALECTRO UNIGUARD SUPERFLOW UG-3-NS-AOS quick start guide

Smartek NUBI 4.0 manual

Smartek

Smartek NUBI 4.0 manual

FireAngel Wi-Safe 2 user manual

FireAngel

FireAngel Wi-Safe 2 user manual

aguilera AE/C5-OPT Technical manual

aguilera

aguilera AE/C5-OPT Technical manual

Kidde i9010 user guide

Kidde

Kidde i9010 user guide

United Technologies Kidde P4010ACSCO-WCA user guide

United Technologies

United Technologies Kidde P4010ACSCO-WCA user guide

PSA Lifesaver 6800RL manual

PSA

PSA Lifesaver 6800RL manual

Numens SNA-360 installation instructions

Numens

Numens SNA-360 installation instructions

Honeywell GasAlert Extreme user manual

Honeywell

Honeywell GasAlert Extreme user manual

Teletek electronics SensoIRIS MCP150 installation instructions

Teletek electronics

Teletek electronics SensoIRIS MCP150 installation instructions

System Sensor DNRA Installation and maintenance instructions

System Sensor

System Sensor DNRA Installation and maintenance instructions

LEGRAND tynetec ZXT810 quick start guide

LEGRAND

LEGRAND tynetec ZXT810 quick start guide

Hochiki ESP FIREbeam installation manual

Hochiki

Hochiki ESP FIREbeam installation manual

VESDA VLQ-100 Product guide

VESDA

VESDA VLQ-100 Product guide

First Alert 3120B user manual

First Alert

First Alert 3120B user manual

Universal Security Instruments 2975CN instructions

Universal Security Instruments

Universal Security Instruments 2975CN instructions

American Sensor SA308 manual&nbsp;

American Sensor

American Sensor SA308 manual&nbsp;

H+H RM 04 operating instructions

H+H

H+H RM 04 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.