Eable Tracker
Send TONE:
Connect the test leads to the pair, or attach one lead to ground
and one lead to either side of the line. A dual alternating tone, or a
single solid tone can be selected from the switch inside the
Sender. Probe the suspected wires with the Receiver, reception
oftone will be strongest on the subject wire. in cases of ready
access to bare conductors, the Receiver may be used to receive
the tone.
*ATTENTtoN: Do Nor coNNEcr ro ANyAcnvE AC
CIRCUIT EXCEEDING 24V IN THIS MODE.
Track Gables or Wires:
Use Sondor(switch to "TONE")and Receiver
Connect the test leads to the pair, or attach one lead to ground
and one lead to either side of the line. using the Receiver close to
and along the object pair, and reception of the tone is indication
tracking.
*ATTENTION;DO NOT CONNECT TO ANYACTIVE CIRICUIT
IN THIS MODE.
Eable Tracker
Identify the state of working telephone line:
Use Sender (switch "OFF")
Oldentify TIP&RING:
Connect the RED test lead to the side of one line and the
BLACK lead to the another side of line.
a."CONT" indicator light is "green" when you connect
the RED test lead to the RING side of line.
b."CONT' indicator light is "red" when you connect
the RED test lead to the TIP side of line.
@ldentify CLEAR, RINGING, BUSY state on the working
telephone line:
Connect the RED test lead to the RING side, BLACK to the
TIP side.
a."CONT" indicator light is "green",indicates a CLEAR line.
b"'CONT' indicator dose not glow, indicates a BUSY
line.
c."CONT" indicator light brightly flickering 'YELLOW",
indicates a RINGING lin€.(Switching to "CONT" will
termlnatB the call on the subject line)
@ln cases of ready access to baro conductors, Receiver may be
used to receive the tone.
Battery Replacement:
@Sender Battery replacement:
Remove the battery cabinet cover on the back
of the Sender, and replace the new 9V battery.
@Receiver Battery replacement:
Rrmove the bolt of the battery cabinet cover on
the back of the Receiver, and replace the new
9V battery.
j
Eable Tracker
Attention
@ When nonuse, take away the Sender from the
test circuitry, and switch to "OFF".
@ Keep away from moisture.
@ Do not use the tester under the hight voltage
enviroment. Allways follow this user's manual,
otherwise it may cause the damage to the tester
or personal injury.
rT
r!