Ciena 3916 AC Standard Installation and operation manual

009-3226-001 - Standard Revision E
July 2015
Copyright©2013-2015 Ciena®Corporation. All rights reserved.
3916 Service Delivery Switch
Hardware Installation and Start-up Manual
3916 AC Standard (170-3916-900)
3916 DC Standard (170-3916-901)
3916 Dual AC Standard (170-3916-902)
3916 AC Mini (170-3916-904)
3916 Dual AC Mini (170-3916-906)
What’s inside...
Overview
Installation
Turning Up the System
LED Overview
Technical Specifications
Regulatory Compliance
Reset Button

3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
LEGAL NOTICES
THIS DOCUMENT CONTAINS TRADE SECRET INFORMATION OF CIENA CORPORATION AND
ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR DISCLOSE ITS
CONTENTS, OR TO MANUFACTURE, USE, OR SELL ANYTHING THAT IT MAY DESCRIBE. REPRODUCTION,
DISCLOSURE, OR USE IN WHOLE OR IN PART WITHOUT THE SPECIFIC WRITTEN AUTHORIZATION
OF CIENA CORPORATION IS STRICTLY FORBIDDEN.
EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION IN THIS DOCUMENT IS
COMPLETE AND ACCURATE AT THE TIME OF PUBLISHING; HOWEVER, THE INFORMATION CONTAINED IN
THIS DOCUMENT IS SUBJECT TO CHANGE.
While the information in this document is believed to be accurate and reliable, except as otherwise expressly
agreed to in writing CIENA PROVIDES THIS DOCUMENT “AS IS” WITHOUT WARRANTY OR CONDITION OF
ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are
subject to change without notice.
Copyright©2013-2015 Ciena®Corporation. All Rights Reserved
The material contained in this document is also protected by copyright laws of the United States of America and
other countries. It may not be reproduced or distributed in any form by any means, altered in any fashion, or stored
in a data base or retrieval system, without express written permission of the Ciena Corporation.
Security
Ciena®cannot be responsible for unauthorized use of equipment and will not make allowance or credit for
unauthorized use or access.
Contacting Ciena
For additional office locations and phone numbers, please visit the Ciena web site at www.ciena.com.
Corporate Headquarters 410-694-5700 or 800-921-1144 www.ciena.com
Customer Technical Support/Warranty
In North America 1-800-CIENA24 (243-6224)
410-865-4961
In Europe, Middle East,
and Africa 800-CIENA-24-7 (800-2436-2247)
+44-207-012-5508
In Asia-Pacific 800-CIENA-24-7 (800-2436-2247)
+81-3-6367-3989
+91-124-4340-600
In Caribbean and Latin
America 800-CIENA-24-7 (800-2436-2247)
410-865-4944 (USA)
In India +91-124-434-0500 E-mail: sales@ciena.com
Training 877-CIENA-TD (243-6283)

3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
IMPORTANT: PLEASE READ THIS LICENSE AGREEMENT (“AGREEMENT”) CAREFULLY BEFORE
INSTALLING OR USING CIENA CORPORATION (“Ciena”) SOFTWARE, HARDWARE OR DOCUMENTATION
(COLLECTIVELY, THE “EQUIPMENT”).
BY INSTALLING OR USING THE EQUIPMENT, YOU ACKNOWLEDGE THAT YOU HAVE READ THIS
AGREEMENT AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS.
1. Right to Use License; Restrictions. Subject to these terms, and the payment of all applicable license fees,
Ciena grants to you, as end user, a non-exclusive license to use the Ciena software (the “Software”) in object code
form solely in connection with, and as embedded within, the Equipment,. You shall have the right to use the
Software solely for your own internal use and benefit. You may make one copy of the Software and documentation
solely for backup and archival purpose, however you must reproduce and affix all copyright and other proprietary
rights notices that appear in or on the original. You may not, without Ciena's prior written consent, (i) sublicense,
assign, sell, rent, lend, lease, transfer or otherwise distribute the Software; (ii) grant any rights in the Software or
documentation not expressly authorized herein; (iii) modify the Software nor provide any third person the means to
do the same; (iv) create derivative works, translate, disassemble, recompile, reverse engineer or attempt to obtain
the source code of the Software in any way; or (v) alter, destroy, or otherwise remove any proprietary notices or
labels on or embedded within the Software or documentation. You acknowledge that this license is subject to
Section 365 of the U.S. Bankruptcy Code and requires Ciena's consent to any assignment related to a bankruptcy
proceeding. Sole title to the Software and documentation, to any derivative works, and to any associated patents
and copyrights, remains with Ciena or its licensors. Ciena reserves to itself and its licensors all rights in the
Software and documentation not expressly granted to you. You shall preserve intact any notice of copyright,
trademark, logo, legend or other notice of ownership from any original or copies of the Software or documentation.
2. Audit: Upon Ciena's reasonable request, but not more frequently than annually without reasonable cause, you
shall permit Ciena to audit the use of the Software at such times as may be mutually agreed upon to ensure
compliance with this Agreement.
3.U.S. Government Use. The Software is provided to the Government only with restricted rights and limited rights.
Use, duplication, or disclosure by the Government is subject to restrictions set forth in FAR Sections 52-227-14 and
52-227-19 or DFARS Section 52.227-7013(C)(1)(ii), as applicable. The Equipment and any accompanying technical
data (collectively “Materials”) are commercial within the meaning of applicable Federal acquisition regulations.
These Materials were developed fully at private expense. U.S. Government use of the Materials is restricted by this
Agreement, and all other U.S. Government use is prohibited. In accordance with FAR 12.212 and DFAR
Supplement 227.7202, software delivered to you is commercial computer software and the use of that software is
further restricted by this Agreement.
4.Term of License. This license is effective until terminated. Customer may terminate this license at any time by
giving written notice to Ciena [or] and destroying or erasing all copies of Software including any documentation.
Ciena may terminate this Agreement and your license to the Software immediately by giving you written notice of
termination in the event that either (i) you breach any term or condition of this Agreement or (ii) you are wound up
other than voluntarily for the purposes of amalgamation or reorganization, have a receiver appointed or enter into
liquidation or bankruptcy or analogous process in your home country. Termination shall be without prejudice to any
other rights or remedies Ciena may have. In the event of any termination you will have no right to keep or use the
Software or any copy of the Software for any purpose and you shall destroy and erase all copies of such Software in
its possession or control, and forward written certification to Ciena that all such copies of Software have been
destroyed or erased.
5.Compliance with laws. You agree to comply with all applicable laws, including all import regulations, and to
obtain all required licenses and permits related to installation and use of Equipment. Software, including technical
data, is subject to U.S. export control laws, including the U.S. Export Administration Act and its associated
regulations, and may be subject to export or import regulations in other countries. Customer agrees to comply
strictly with all such regulations and acknowledges that it has the responsibility to obtain licenses to export, re-
export, or import Software.

3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
6.Limitation of Liability. ANY LIABILITY OF Ciena SHALL BE LIMITED IN THE AGGREGATE TO THE
AMOUNTS PAID BY YOU FOR THE SOFTWARE. THIS LIMITATION APPLIES TO ALL CAUSES OF ACTION,
INCLUDING WITHOUT LIMITATION BREACH OF CONTRACT, BREACH OF WARRANTY, NEGLIGENCE,
STRICT LIABILITY, MISREPRESENTATION AND OTHER TORTS. THE LIMITATIONS OF LIABILITY
DESCRIBED IN THIS SECTION ALSO APPLY TO ANY THIRD-PARTY SUPPLIER OF Ciena. NEITHER Ciena
NOR ANY OF ITS THIRD-PARTY SUPPLIERS SHALL BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE,
WHETHER INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL INCLUDING WITHOUT LIMITATION ANY
LOST PROFITS, CONTRACTS, DATA OR PROGRAMS, AND THE COST OF RECOVERING SUCH DATA OR
PROGRAMS, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE
7General. Ciena may assign this Agreement to any Ciena affiliate or to a purchaser of the intellectual property
rights in the Software, but otherwise neither this Agreement nor any rights hereunder may be assigned nor duties
delegated by either party, and any attempt to do so will be void. This Agreement shall be governed by the laws of
the State of Maryland (without regard to the conflict of laws provisions) and shall be enforceable in the courts of
Maryland. The U.N. Convention on Contracts for the International Sale of Goods shall not apply hereto. This
Agreement constitutes the complete and exclusive statement of agreement between the parties relating to the
license for the Software and supersedes all proposals, communications, purchase orders, and prior agreements,
verbal or written, between the parties. If any portion hereof is found to be void or unenforceable, the remaining
provisions shall remain in full force and effect.

v
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Publication History 0
August 2012
•Revision A, Standard:
— Documentconvertedtoanewtemplateandassignedanewdocument
number. This document replaces the document 009-2010-118.
— Existing content covering 3916 AC and 3916 DC systems has been
restructured
— Document updated to include 3916 Dual AC system
— Overview material has been moved to 39XX/51XX Product
Fundamentals
— Optics information remains in Packet Networking Transceivers
Reference (009-2011-602)
— Orderable part number information removed. For ordering assistance
please contact your Ciena representative.
October 2012
•Revision B, Standard:
— Change title of document
— Update references to other documents in the set
September 2013
•Revision C, Standard:
— Minor maintenance changes to reincorporate notes and cautions in
the installation chapter and to add a note to the procedure for creating
a remote management interface.
— Updated the document to cover the new mini chassis versions for the
single and dual AC systems. These units have the same functionality
as the original units. Changes to the chassis include: a smaller form
factor, new faceplate layout, and front to back airflow.
August 2014
•Revision D, Standard:
— Updated “Turning Up the System” on page 3-1

vi Publication History
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
— Minor update to procedure, “Logging in through the Serial Console
Port” on page 3-7
— Updated “Managing Licenses” on page 3-4
July 2015
•Revision E, Standard:
— Updated “Overview” on page 1-1
— Updated “Creating a New User Account” on page 3-3
— Updated “Ethernet Cables” on page 2-12
— Updated“10/100/1000 Mbps Port LEDs” on page 4-5

vii
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Contents 0
About this Document ix
Overview 1-1
Installation 2-1
Important Safety Information 2-1
Package Contents 2-4
Required Tools and Supplies 2-4
Mounting the 3916 2-5
Frame Installation 2-5
Wall Mounting 2-5
Desktop Installation 2-5
Grounding the Chassis 2-6
Power Supply Grounding 2-6
Supplemental Ground 2-6
Power Cabling 2-7
Installing Power to a 3916 AC System 2-7
Installing Power to a 3916 DC System 2-9
Transceivers 2-10
Cable Installation and Guidelines 2-11
Connecting Cables to the 3916 2-12
Fiber Optic Cables 2-12
Ethernet Cables 2-12
Initial Configuration 2-13
List of procedures
2-1 To Install 3916 in a Frame 2-14
2-2 To Install 3916 on a Wall 2-16
2-3 To Install 3916 on a Desktop 2-17
2-4 Installing the Mounting Brackets for a 19-inch Frame Installation 2-18
2-5 Installing Mounting Brackets for a 23-inch Frame Installation 2-19
2-6 Installing the Mounting Brackets in a Wall Mount Installation 2-21
2-7 Mounting the Chassis and Installing Supplemental Ground in a Frame
Installation 2-22
2-8 Mounting the Chassis (Supplemental Ground not required) in a Frame
Installation 2-24
2-9 Mounting the Chassis and Installing Supplemental Ground in a Wall Mount
Installation 2-25

viii Contents
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
2-10 Mounting the Chassis (Supplemental Ground not required) in a Wall Mount
Installation 2-27
2-11 Installing the Cable Support Brackets 2-29
2-12 Installing an AC Power Cable in a Standard Chassis system 2-30
2-13 Installing an AC Power Cable in a Mini Chassis system 2-32
2-14 Installing a DC Power Cable 2-34
2-15 To Install a Pluggable Optic 2-37
2-16 To Remove a Pluggable Optic 2-39
2-17 Installing a Fiber Optic Cable 2-40
Turning Up the System 3-1
Logging in through the Serial Console Port 3-2
Console Cable 3-2
Creating a New User Account 3-3
Deleting a User Account 3-4
Managing Licenses 3-4
Configuring the Remote Management Interface 3-4
Accessing the CLI Using Telnet 3-5
Setting the System Host Name 3-5
Logging Out of the System 3-6
List of procedures
3-1 Logging in through the Serial Console Port 3-7
3-2 Creating a new user account 3-8
3-3 Deleting a user account 3-11
3-4 Managing Licenses 3-12
3-5 Configuring the Remote Management Interface 3-13
3-6 Accessing the CLI using Telnet 3-14
3-7 Setting the System Host Name 3-15
3-8 Logging out of the System 3-16
LED Overview 4-1
Unit Status LEDs 4-2
Power Status LEDs 4-3
10/100/1000 Mbps Port LEDs 4-5
Reset Button 5-1
Technical Specifications 6-1
Regulatory Compliance 7-1
Canada 7-2
CE Compliance 7-2
FCC Statement 7-3
VCCI - Japan 7-3

ix
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
About this Document 0
This document outlines the methodologies to be followed during the
Installation of 3916 Service Delivery Switch from Ciena Corporation. The
following versions of the 3916 are available:
• 3916 AC Standard (170-3916-900) with integrated front fixed AC power
supply in the standard chassis size
• 3916 Dual AC Standard(170-3916-902) with two integrated front fixed AC
power supplies in the standard chassis size
• 3916 DC Standard (170-3916-901) with integrated front fixed DC power
supply in the standard chassis size
• 3916 AC Mini (170-3916-904) with integrated frontfixed AC power supply
in the mini chassis size
• 3916 Dual AC Mini (170-3916-906) with integrated front fixed AC power
supply in the mini chassis size
This document covers the installation instructions for both the AC and DC
variants of the product.
Overview information about the 3916 is discussed in 39XX/51XX Product
Fundamentals. Please see that document for background information.
Intended Audience
This document is intended for certified system installation technicians and
system administrators responsible for the installation of a 3916 system. All
3916 installationpersonnel are required to read, understand, and observe the
safety precautions described in the product manual.

xAbout this Document
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Related Documentation
The latest version of this document, release notes, and all Ciena
documentation are available through the Ciena website at:
http://www.ciena.com.
The following list contains the names of the related documents in the suite:
• 39XX/51XX Product Fundamentals
•39XX/51XX Software Management and Licensing
•39XX/51XX Administration and Security
•39XX/51XX Command Reference
•39XX/51XX Configuration
• 39XX/51XX Fault and Performance
• 39XX/51XX MIB Reference
•39XX/51XX System Event Reference
•Packet Networking Glossary (009-3299-026)
•Packet Networking Transceivers Reference (009-2011-602)
Document Ordering Information
To order additional documentation, the user can contact the local sales
representativeorCiena throughthecontactnumbersand/ore-mailaddresses
listed on the back of the front cover.
Document Comments
Ciena appreciates all comments that will help us to improve our
documentationquality.The usercansubmitcommentsthroughtheCienaweb
site (http://www.ciena.com).
Additional Product Information
Additional product information can be obtained by contacting the local sales
representativeorCiena throughthecontactnumbersand/ore-mailaddresses
listed on the back of the front cover.

About this Document xi
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015

xii About this Document
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015

1-1
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Overview 1-
The Ciena Service Delivery Switch (SDS) products provide Ethernet
connectivity to buildings and residences to deliver high-speed voice, video,
and data connectivity. SDS devices are designed to lower the overall cost of
building out a fiber network.
The 3916 small SDS is a low port count Carrier Ethernet platform providing
premium Ethernet capability and targeting highly competitive Network
Termination and Intelligent Demarcation applications. Multiple versions of the
3916 are available. All of the systems have the same port count, but the
following items differ between systems:
• Chassis size — both standard and mini chassis sizes are available. The
dimensions are as follows:
— Standard Chassis dimensions: 13.1 inches x 7.9 inches x 1.75 inches
(33.3 cm x 20.1 cm x 4.4 cm)
— Mini chassis dimensions: 10.85 inches x 6.78 inches x 1.71 inches
(27.6 cm x 17.2 cm x 4.3 cm)
• Power system — both AC and DC systems are available. As well, the AC
systemis availablein bothsingle ordual variants.Inall systems thepower
connections are integrated and accessed on the front faceplate.
• Airflow — the airflow in the chassis differs between the standard and mini
chassis as follows:
— StandardChassis:airflowis sidetoside,drawingair fromtherightside
and exhausting air to the left of the chassis.
— Mini chassis: airflow is front to back, drawing air from the front
faceplate and exhausting air to the rear of the chassis.
Table 1-1 on page 1-2 provides a summary.

1-2 Overview
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
The 3916 can be deployed in Central Offices (CO), customer premises (CPE)
and other environmentally controlled telecommunications spaces. The 3916
is part of a group of products designed to address the connectivity
requirementsof different sites and services.In addition, Ciena offers SDS and
SAS units designed for both outside plant and interior applications. A full
description of the various products in the portfolio, including a hardware
overview of the 3916, is contained in 39XX/51XX Product Fundamentals.
The SDS units are designed to work with other Ciena products to deliver
complete, integrated service offerings from a single provider or multiple
providers. The SDS devices incorporate advanced QoS capabilities, flexibility
through pluggable optics, superior multicast control, manageability, and a
smallform factor chassisto presentthe industry’sleadingfiber-to-the-building
solution.
Table 1-2 provides anoverview of the interfaces available on the 3916 switch.
In addition, the 3916 has the following physical characteristics:
• Single integrated front fixed AC or DC power supply or dual integrated
front fixed AC power supplies
• 1 RU form factor
Table 1-1
3916 System Summary
System Part Number Power System Chassis Size Airflow
3916 AC Standard 170-3916-900 Single AC Standard Side to Side
(right to left)
3916 Dual AC Standard 170-3916-902 Dual AC Standard Side to Side
(right to left)
3916 DC Standard 170-3916-901 Single DC Standard Side to Side
(right to left)
3916 AC Mini 170-3916-904 Single AC Mini Front to back
3916 Dual AC Mini 170-3916-906 Dual AC Mini Front to back
Note: For more information, see 39XX/51XX Product Fundamentals.

Overview 1-3
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Figure 1-1 on page 1-4 shows the 3916 standard chassis. Figure 1-2 on page
1-4 shows the 3916 mini chassis.
Table 1-2
3916 interface summary
Port type Number of
ports Description
NNI 2 100/1000 Mbps ports with SFP connectors. These are ports 3 and 4.
Copper SFPs installed in these ports support 10/100/1000 Mbps.
NNI 2 1000 Mbps ports with SFP connectors. These are ports 5 and 6.
Copper SFPs installed in these ports support 1G.
UNI 2 10/100/1000Mbps combo RJ-45/SFP ports. The SFPs support both 100
Mbps and 1000 Mbps speeds. These are ports 1 and 2.
The combo ports have both a copper and an optical version of the same
port. Both ports can be cabled, however only one of the pair of copper/
optic ports will be active at any time. The combo ports are controlled
through the software.
Copper SFPs installed in these ports support 1G.
Console 1 Serial EIA-561 (RJ-45) port
Note 1: For the combo ports, only one of the two ports will be active. Either the copper or the optical
port will be active.
Note 2: Only Ciena approved SFPs can be used with the 3916. For more information see Packet
Networking Transceivers Reference (009-2011-602).

1-4 Overview
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Figure 1-1
View of the 3916 (Standard Chassis)
Figure 1-2
View of the 3916 (Mini Chassis)
3916 AC Standard
3916 DC Standard
3916 Dual AC Standard
3916 Single AC Mini
3916 Dual AC Mini

2-1
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Installation 2-
The 3916 is designed for deployment in indoor locations and partially
controlled environments. This includes: Outside Plant (OSP) Huts, Controlled
Environmental Vaults (CEVs) and other OSP enclosures with active
environmental controls. The 3916 can also be deployed in a central office
environment. The 3916 can be mounted on a wall, desk or rack. When rack
mounted the unit requires 1 RU of space.
This chapter provides installation instructions. It discusses the following
topics:
•“Important Safety Information”
•“Package Contents”
•“Mounting the 3916”
•“Grounding the Chassis”
•“Power Cabling”
•“Transceivers”
•“Cable Installation and Guidelines”
•“Initial Configuration”
Important Safety Information
Please review the safety information before beginning the installation.
WARNING
Read all installation instructions before connecting a 3916
device to a power source.

2-2 Installation
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Note: This unit has been designed and tested for installation in areas
prone to earthquakes (zone 4). To ensure proper operation it must be
installed in a proper frame.
WARNING
The chassis of the 3916 should never be opened under any
circumstances. Opening the chassis will void the warranty.
The system chassis must be returned to Ciena for service or
replacement.
Power supply modules and transceivers are field-replaceable,
however, the modules or transceivers must be returned to
Ciena for service or replacement.
WARNING
Before working on equipment that is connected to power lines,
remove jewelry (including rings, necklaces, and watches).
Metal objects will heat up when connected to power and
ground and can cause serious burns or weld the metal object
to the terminals.
WARNING
Do not work on the system or connect or disconnect cables
during periods of lightning activity.
WARNING
To preventESDdamagetoelectroniccomponents,alwaysuse
an ESD wrist strap when handling modules.
WARNING
Do not stack anything on top of this unit. The mounting
brackets provided with this unit are designed to support only
the weight of this unit, if they fail due to excess weight, it can
cause bodily injury and damage the equipment.

Installation 2-3
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
WARNING
When installing the unit, ensure that the wiring meets the
national and local electrical codes.
WARNING
All AC power cords must meet the requirements of the local
and national electric codes prior to installation
WARNING
The 3916 AC relies on the AC power cord for the safety
ground. The outlet providing power to the 3916 must meet the
local and national Safety codes. The 3916 DC relies on the DC
Input connector GND connection for safety ground.
WARNING
All electrical interfaces on this product are intended for intra-
building connections only. These interfaces are designed as
type 2 or type 4 ports as described in GR-1089-CORE, Issue 6
and require isolation from the exposed outside plant cabling.
WARNING
For pluggable equipment, the socket outlet shall be installed
near the equipment and be easily accessible.

2-4 Installation
3916 Service Delivery Switch Hardware Installation and Start-up Manual
009-3226-001 Standard Revision E
Copyright©2013-2015 Ciena®Corporation July 2015
Package Contents
Upon receipt, examine all shipping containers and their contents. Carefully
unpack the 3916 from the packing material. Visually inspect all parts for
damage.
The following items are shipped with the 3916:
• Chassis
• Mounting bracket kit for 19” frame (two brackets, two cable supports, two
8-32 x 1/2 lengthscrews used to attach the cable supports to thebrackets,
and four 8-32 x 5/16 length pan head screws used to attach the brackets
to the side of the chassis)
• Four self-adhesive rubber feet
If the unit is damaged or if any of the above items are missing, please contact
your sales representative.
Note: Mounting brackets for 23-inch racks are also available. If they are
required for your installation, you need to order these brackets separately.
You will also need to order:
• Power cable(s)
• SFP modules for the 100/1000 Mbps ports (up to 6 ports)
• Faceplate cabling (Cat 5e STP and optical cabling to match the SFP
connector types used)
Required Tools and Supplies
For rack mount installations you will also require the following tools:
• Flat head screwdriver
• Phillips #2 screwdriver
• Ratchet crimper (for ground wire/lug)
• Wire-strippers (for DC power cable)
• Digital Volt Ohm Meter
• Rack screws (4 per device)
• Cable ties / cord retainers — to secure ground, power and interface
cabling
• Fork terminal spade lugs (3 per DC power supply) — to install power
cabling to a DC system
• Power wire (14 to 18 AWG) — to install power cabling to a DC system
Note: Table 2-1 on page 2-9 provides a summary of the DC lugs that are
recommended for use with the 3916.
This manual suits for next models
9
Table of contents
Other Ciena Switch manuals