Ciena 5150 Installation and operation manual

009-3222-001 - Standard Revision H
July 2015
Copyright©2012-2015 Ciena®Corporation. All rights reserved.
5150 Service Aggregation Switch
Hardware Installation and Start-up Manual
What’s inside...
Overview
Installation
Turning Up the System
Maintenance
LED Overview
Technical Specifications
Regulatory Compliance
Mounting Options
Reset Button

5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
LEGAL NOTICES
THIS DOCUMENT CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION OF CIENA
CORPORATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE
OR DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE, OR SELL ANYTHING THAT IT MAY DESCRIBE.
REPRODUCTION, DISCLOSURE, OR USE IN WHOLE OR IN PART WITHOUT THE SPECIFIC WRITTEN
AUTHORIZATION OF CIENA CORPORATION IS STRICTLY FORBIDDEN.
EVERY EFFORT HAS BEEN MADE TO ENSURE THAT THE INFORMATION IN THIS DOCUMENT IS
COMPLETE AND ACCURATE AT THE TIME OF PUBLISHING; HOWEVER, THE INFORMATION CONTAINED IN
THIS DOCUMENT IS SUBJECT TO CHANGE.
While the information in this document is believed to be accurate and reliable, except as otherwise expressly
agreed to in writing CIENA PROVIDES THIS DOCUMENT “AS IS” WITHOUT WARRANTY OR CONDITION OF
ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are
subject to change without notice.
Copyright©2012-2015 Ciena®Corporation. All Rights Reserved
The material contained in this document is also protected by copyright laws of the United States of America and
other countries. It may not be reproduced or distributed in any form by any means, altered in any fashion, or stored
in a data base or retrieval system, without express written permission of the Ciena Corporation.
Security
Ciena®cannot be responsible for unauthorized use of equipment and will not make allowance or credit for
unauthorized use or access.
Contacting Ciena
For additional office locations and phone numbers, please visit the Ciena web site at www.ciena.com.
Corporate Headquarters 410-694-5700 or 800-921-1144 www.ciena.com
Customer Technical Support/Warranty
In North America 1-800-CIENA24 (243-6224)
410-865-4961
In Europe, Middle East,
and Africa 800-CIENA-24-7 (800-2436-2247)
+44-207-012-5508
In Asia-Pacific 800-CIENA-24-7 (800-2436-2247)
+81-3-6367-3989
+91-124-4340-600
In Caribbean and Latin
America 800-CIENA-24-7 (800-2436-2247)
410-865-4944 (USA)
In India +91-124-434-0500 E-mail: sales@ciena.com
Training 877-CIENA-TD (243-6283)

5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
IMPORTANT: PLEASE READ THIS LICENSE AGREEMENT (“AGREEMENT”) CAREFULLY BEFORE
INSTALLING OR USING CIENA CORPORATION (“Ciena”) SOFTWARE, HARDWARE OR DOCUMENTATION
(COLLECTIVELY, THE “EQUIPMENT”).
BY INSTALLING OR USING THE EQUIPMENT, YOU ACKNOWLEDGE THAT YOU HAVE READ THIS
AGREEMENT AND AGREE TO BE BOUND BY ITS TERMS AND CONDITIONS.
1. Right to Use License; Restrictions. Subject to these terms, and the payment of all applicable license fees,
Ciena grants to you, as end user, a non-exclusive license to use the Ciena software (the “Software”) in object code
form solely in connection with, and as embedded within, the Equipment,. You shall have the right to use the
Software solely for your own internal use and benefit. You may make one copy of the Software and documentation
solely for backup and archival purpose, however you must reproduce and affix all copyright and other proprietary
rights notices that appear in or on the original. You may not, without Ciena's prior written consent, (i) sublicense,
assign, sell, rent, lend, lease, transfer or otherwise distribute the Software; (ii) grant any rights in the Software or
documentation not expressly authorized herein; (iii) modify the Software nor provide any third person the means to
do the same; (iv) create derivative works, translate, disassemble, recompile, reverse engineer or attempt to obtain
the source code of the Software in any way; or (v) alter, destroy, or otherwise remove any proprietary notices or
labels on or embedded within the Software or documentation. You acknowledge that this license is subject to
Section 365 of the U.S. Bankruptcy Code and requires Ciena's consent to any assignment related to a bankruptcy
proceeding. Sole title to the Software and documentation, to any derivative works, and to any associated patents
and copyrights, remains with Ciena or its licensors. Ciena reserves to itself and its licensors all rights in the
Software and documentation not expressly granted to you. You shall preserve intact any notice of copyright,
trademark, logo, legend or other notice of ownership from any original or copies of the Software or documentation.
2. Audit: Upon Ciena's reasonable request, but not more frequently than annually without reasonable cause, you
shall permit Ciena to audit the use of the Software at such times as may be mutually agreed upon to ensure
compliance with this Agreement.
3. Confidentiality. You agree that you will receive confidential or proprietary information (“Confidential Information”)
in connection with the purchase, deployment and use of the Equipment. You will not disclose Confidential
Information to any third party without prior written consent of Ciena, will use it only for purposes for which it was
disclosed, use your best efforts to prevent and protect the contents of the Software from unauthorized disclosure or
use, and must treat it with the same degree of care as you do your own similar information, but with no less than
reasonable care. You acknowledge that the design and structure of the Software constitute trade secrets and/or
copyrighted materials of Ciena and agree that the Equipment is Confidential Information for purposes of this
Agreement.
4. U.S. Government Use. The Software is provided to the Government only with restricted rights and limited rights.
Use, duplication, or disclosure by the Government is subject to restrictions set forth in FAR Sections 52-227-14 and
52-227-19 or DFARS Section 52.227-7013(C)(1)(ii), as applicable. The Equipment and any accompanying technical
data (collectively “Materials”) are commercial within the meaning of applicable Federal acquisition regulations.
These Materials were developed fully at private expense. U.S. Government use of the Materials is restricted by this
Agreement, and all other U.S. Government use is prohibited. In accordance with FAR 12.212 and DFAR
Supplement 227.7202, software delivered to you is commercial computer software and the use of that software is
further restricted by this Agreement.
5. Term of License. This license is effective until terminated. Customer may terminate this license at any time by
giving written notice to Ciena [or] and destroying or erasing all copies of Software including any documentation.
Ciena may terminate this Agreement and your license to the Software immediately by giving you written notice of
termination in the event that either (i) you breach any term or condition of this Agreement or (ii) you are wound up
other than voluntarily for the purposes of amalgamation or reorganization, have a receiver appointed or enter into
liquidation or bankruptcy or analogous process in your home country. Termination shall be without prejudice to any
other rights or remedies Ciena may have. In the event of any termination you will have no right to keep or use the
Software or any copy of the Software for any purpose and you shall destroy and erase all copies of such Software in
its possession or control, and forward written certification to Ciena that all such copies of Software have been
destroyed or erased.
6. Compliance with laws. You agree to comply with all applicable laws, including all import regulations, and to
obtain all required licenses and permits related to installation and use of Equipment. Software, including technical
data, is subject to U.S. export control laws, including the U.S. Export Administration Act and its associated
regulations, and may be subject to export or import regulations in other countries. Customer agrees to comply
strictly with all such regulations and acknowledges that it has the responsibility to obtain licenses to export, re-
export, or import Software.

5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
7. Limitation of Liability. ANY LIABILITY OF Ciena SHALL BE LIMITED IN THE AGGREGATE TO THE
AMOUNTS PAID BY YOU FOR THE SOFTWARE. THIS LIMITATION APPLIES TO ALL CAUSES OF ACTION,
INCLUDING WITHOUT LIMITATION BREACH OF CONTRACT, BREACH OF WARRANTY, NEGLIGENCE,
STRICT LIABILITY, MISREPRESENTATION AND OTHER TORTS. THE LIMITATIONS OF LIABILITY
DESCRIBED IN THIS SECTION ALSO APPLY TO ANY THIRD-PARTY SUPPLIER OF Ciena. NEITHER Ciena
NOR ANY OF ITS THIRD-PARTY SUPPLIERS SHALL BE LIABLE FOR ANY INJURY, LOSS OR DAMAGE,
WHETHER INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL INCLUDING WITHOUT LIMITATION ANY
LOST PROFITS, CONTRACTS, DATA OR PROGRAMS, AND THE COST OF RECOVERING SUCH DATA OR
PROGRAMS, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES IN ADVANCE
8. General. Ciena may assign this Agreement to any Ciena affiliate or to a purchaser of the intellectual property
rights in the Software, but otherwise neither this Agreement nor any rights hereunder may be assigned nor duties
delegated by either party, and any attempt to do so will be void. This Agreement shall be governed by the laws of
the State of Maryland (without regard to the conflict of laws provisions) and shall be enforceable in the courts of
Maryland. The U.N. Convention on Contracts for the International Sale of Goods shall not apply hereto. This
Agreement constitutes the complete and exclusive statement of agreement between the parties relating to the
license for the Software and supersedes all proposals, communications, purchase orders, and prior agreements,
verbal or written, between the parties. If any portion hereof is found to be void or unenforceable, the remaining
provisions shall remain in full force and effect.

v
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Publication history 0
October 2012
•Revision A, Standard:
— Document assigned a new document number. This document
replaces the document 009-2009-529.
— Overview material has been moved to 39XX/51XX Product
Fundamentals
— Optics information remains in Packet Networking Transceivers
Reference (009-2011-602)
— Orderable part number information removed. For ordering assistance
please contact your Ciena representative.
December 2012
•Revision B, Standard:
— Updated to add the new 10 GbE Standard with BITS module.
February 2013
•Revision C, Standard:
— Updated the cable requirement for the SYNC port.
— Add a note to the procedure for creating a remote management
interface.
— Add notes/warnings to the Installation chapter.
September 2013
•Revision D, Standard:
— Updated the Alarm Port Pin assignments.
— Rebrand portfolio as Packet Networking (was Carrier Ethernet
Solutions).
— Update name for the transceiver reference to Packet Networking
Transceivers Reference (009-2011-602) and the glossary to Packet
Networking Glossary (009-3299-026)
— Add new appendix covering reset button information

vi Publication history
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
May 2014
•Revision E, Standard:
— Minor update to procedure “Logging in through the Serial Console
Port” on page 3-7
— Added 5150 Packet Timing information to “Overview” on page 1-1
August 2014
•Revision F, Standard:
— Updated “Managing Licenses” on page 3-3
— Updated “Configuring the Local Management Interface” on page 3-4
— Updated “Mounting Options” on page 8-1
May 2015
•Revision G, Standard:
— Updated “Creating a New User Account” on page 3-2
July 2015
•Revision H, Standard:
— Updated “Transceivers” on page 2-10

vii
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Contents 0
About this Document xi
Overview 1-1
Installation 2-1
Package Contents 2-1
Required Tools and Supplies 2-2
Important Safety Information 2-3
Mounting the Device 2-4
Wall Mount Installation 2-4
Frame Installation 2-5
Desktop Installation 2-5
Grounding 2-5
Power Supply Grounding 2-5
Supplemental Ground 2-5
10 Gigabit Ethernet Module(s) 2-6
Power Supply Modules 2-7
Connecting AC power to the 5150 power supplies 2-8
Connecting DC power to the 5150 power supplies 2-9
Transceivers 2-10
Cable Installation and Guidelines 2-11
Connecting Cables to the 5150 2-12
Alarm Cable 2-12
Synchronization Cable 2-13
Fiber Optic Cables 2-13
Ethernet Cables 2-14
Initial Configuration 2-14
2-1 To Install 5150 on a Wall 2-15
2-2 To Install 5150 in a Frame 2-16
2-3 To Install 5150 on a Desktop 2-17
2-4 To Install Supplemental Ground 2-18
2-5 To Install the 10 Gigabit Option Modules 2-19
2-6 To Install an AC Power Supply 2-20
2-7 To Install a DC Power Supply 2-22
2-8 To Install an Alarm Cable (Optional) 2-26
2-9 To Install a Pluggable Optic 2-27
2-10 To Remove a Pluggable Optic 2-28

viii Contents
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Turning Up the System 3-1
Logging in through the Serial Console Port 3-1
Creating a New User Account 3-2
Deleting a User Account 3-3
Managing Licenses 3-3
Configuring the Remote Management Interface 3-3
Accessing the CLI Using Telnet 3-4
Configuring the Local Management Interface 3-4
Configuring an Interface using DHCP 3-5
Setting the System Host Name 3-5
Logging Out of the System 3-6
List of procedures
3-1 Logging in through the Serial Console Port 3-7
3-2 Creating a new user account 3-8
3-3 Deleting a user account 3-11
3-4 Managing Licenses 3-12
3-5 Configuring the Remote Management Interface 3-13
3-6 Accessing the CLI using Telnet 3-14
3-7 Configuring the Local Management Interface 3-15
3-8 Configuring an Interface using DHCP 3-16
3-9 Setting the System Host Name 3-17
3-10 Logging out of the System 3-18
Maintenance 4-1
Adding a 10 Gigabit Ethernet Module 4-2
Replacing a 10 Gigabit Ethernet Module 4-2
Replacing a Power Supply Module 4-3
4-1 To Add a 10 Gigabit Ethernet Module 4-4
4-2 To Replace a 10 Gigabit Ethernet Module 4-5
4-3 To Replace an AC Power Supply Module 4-7
4-4 To Replace a DC Power Supply Module 4-9
LED Overview 5-1
Unit Status LEDs 5-2
Power Supply LEDs 5-3
10 Gigabit Ethernet Pluggable Module LEDs 5-4
10 Gigabit Ethernet Port LEDs 5-5
100/1000 Mbps Port LEDs 5-6
Local Management Port LEDs 5-7
Sync Port 5-8
Technical Specifications 6-1
Regulatory Compliance 7-1
Canada 7-3
CE Compliance 7-3
FCC Statement 7-3

Contents ix
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
VCCI- Japan 7-3
Mounting Options 8-1
Wall Mount Bracket Installation Instructions 8-1
19” Frame Mount Bracket - 2 RU 8-2
23” Frame Mount Bracket - 2 RU 8-4
8-1 Installing the Wallmount Bracket 8-5
8-2 Installing the 19” Frame Mount Bracket - 2 RU 8-7
8-3 Installing the 23” Frame Mount Bracket - 2 RU 8-8
Reset Button 9-1

xContents
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015

xi
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
About this Document 0
This document outlines the methodologies to be followed during the
Installation of 5150 Service Aggregation Switch from Ciena Corporation.
Disclaimer While every effort has been made to ensure that this document is complete
and accurate at the time of publishing, the information that it contains is
subject to change. Ciena®is not responsible for any additions to or alterations
of the original document. Networks vary widely in their configurations,
topologies, and traffic conditions. This document is intended as a general
guide only. It has not been tested for all possible applications, and it may not
be complete or accurate for some situations.
Trademark Acknowledgements
Ciena®is a registered trademark of Ciena Corporation.
Intended Audience
This document is intended for certified system installation technicians and
system administrators responsible for the installation of a 5150 system. All
5150 installationpersonnel are required toread, understand, and observe the
safety precautions described in the product manual.
Related Documentation
AdditionalsupportingdocumentationisavailablethroughtheCienawebsiteat
http://www.ciena.com.
The following list contains the names of the related documents in the suite:
• 39XX/51XX Product Fundamentals
•39XX/51XX Software Management and Licensing
•39XX/51XX Administration and Security
•39XX/51XX Command Reference
•39XX/51XX Configuration
• 39XX/51XX Fault and Performance

xii About this Document
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
• 39XX/51XX MIB Reference
•39XX/51XX System Event Reference
•Packet Networking Glossary (009-3299-026)
•Packet Networking Transceivers Reference (009-2011-602)
Document Comments
Ciena appreciates all comments that will help us improve our documentation
quality. The user can submit comments through the Ciena website (http://
www.ciena.com).
Additional Product Information
Additional product information can be obtained by contacting the local sales
representativeorCienathroughthecontactnumbersand/ore-mailaddresses
listed on the back of the front cover.

1-1
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Overview 1-
The Ciena Service Aggregation Switch (SAS) products provide Ethernet
connectivity to buildings and residences to deliver high-speed voice, video,
and data connectivity. SAS devices are designed to lower the overall cost of
deploying a fiber network.
The 5150 is a Service Aggregation Switch that provides both Gigabit Ethernet
and10GigabitEthernet interfaces. The 5150is based on CienaCorporation’s
field-proven Carrier Ethernet technology which is deployed by dozens of
network operators in tens-of-thousands of homes and businesses. The 5150
combines the low cost and high capacity of Ethernet with the reliability,
management, and service quality associated with SONET and TDM.
Ciena offers two 5150 variants, the original 5150 Sync (5150-900) and the
upgraded 5150 Packet Timing (5150-910). The 5150 Packet Timing provides
an upgraded Stratum 3E OCXO oscillator to provide 1588v2 Precision Time
Protocol (PTP) support.
The 5150 uses the Ciena Service Aware Operating System (SAOS) version
6.x. A full description of the various products in the portfolio, including a full
hardware overview of the 5150, is contained in 39XX/51XX Product
Fundamentals. See Figure 1-1.

1-2 Overview
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Figure 1-1
Front of the 5150
The SAS units are designed to work with Ciena products to deliver complete,
integrated service offerings from a single provider or multiple providers. The
SAS devices incorporate advanced QoS capabilities, flexibility through
pluggable optics, superior multicast control, manageability, and a small form
factor chassis to present the industry’s leading fiber-to-the-building solution.
The 5150 has the following physical characteristics:
• 48 x 100/1000 Mbps SFP ports — The SFPs support both 100 Mbps and
1000Mbpsspeeds.Ports1to36 areUNI only.Ports37 to 48(bottom row)
are NNI and UNI capable. Copper or optical SFPs can be installed in any
of these 48 ports.
• 2 x 10 GBE (total of 4 GBE ports) XFP Option Modules — these optional
modules allow you to add 10 GbE ports to your system. The 10 Gigabit
ports can be usedas either NNI or UNI ports. Their installation is optional.
When these modules are not installed, a filler plate is required over the
empty slot.
• 1 x BITS port (optional) — this port can be used to provide BITS-IN or
BITS-OUT. The port is available on the 10 GbE Standard with BITS option
module only. A single module of this type can be installed in the 5150.
Note: The BITS interface can be configured to be either BITS-IN or BITS-
OUT. It cannot support both BITS-IN and BITS-OUT simultaneously.
• 1 x Serial RJ-45 Console port — The Console port is used for initial
configuration and management.
• 1 x 10/100/1000 RJ-45 Management port — This port is provided for out-
of-band management and uses an RJ-45 connector.
48 x 1 Gigabit Ports Power Modules
10 Gigabit
Modules
Management
Interfaces

Overview 1-3
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
• 1 x DB-15 Alarm Input — Closed contact alarm inputs.
The 5150 occupies 2 rack units (RU) of a standard 19-inch equipment rack.
All ports, management interfaces, LEDs and power connections are
accessible from the front of the 5150 chassis. For more information see 39XX/
51XX Product Fundamentals.

1-4 Overview
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015

2-1
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Installation 2-
The 5150 is designed for deployment in Outdoor Street Cabinets, huts and
other unconditioned locations. The 5150 can also be deployed in a central
office environment. The 5150 can be mounted in a standard equipment rack
and requires 2 RUs of space.
This chapter provides installation instructions. It discusses the following
topics:
•“Package Contents”
•“Important Safety Information”
•“Mounting the Device”
•“Grounding”
•“10 Gigabit Ethernet Module(s)”
•“Power Supply Modules”
•“Transceivers”
•“Cable Installation and Guidelines”
•“Initial Configuration”
Package Contents
Upon receipt, examine all shipping containers and their contents. Carefully
unpack the 5150 from the packing material. Visually inspect all parts for
damage.
The following items are shipped with the 5150:
• Chassis (with two empty power supply slots)
• Filler plates (installed over the two slots where the 10 Gigabit Ethernet
Modules can be installed in the center section of the chassis, see Figure
1-1 on page 1-2)
• Grounding screws (the 2 grounding screws will be attached to the back of
the chassis to the right side of center, see Figure 2-2 on page 2-18)

2-2 Installation
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
• Mounting bracket kit for 19” frame (twobrackets, four cable supports, four
8-32 x 1/2 lengthscrews used toattach the cable supports to the brackets,
and eight 8-32 x 5/16 length pan head screws used to attach the brackets
to the side of the chassis. See Figure 8-1 on page 8-3.)
If the unit is damaged or if any of the above items are missing, please contact
your sales representative.
Note: Mounting brackets for wall mount, and 23-inch racks are also
available. If they are required for your installation, you need to order these
brackets separately.
You will also need to order:
• Power supplies (2 DC power supplies)
• Power cables
• Grounding lug and grounding wire
• 10 Gigabit Ethernet Option Modules (optional, up to 2 modules can be
installed)
• XFPs (for the 10 Gigabit ports on the Ethernet Option Modules, 2 or 4
XFPs can be installed)
• SFPs for the 100/1000 Mbps ports (up to 48 ports)
• Faceplate cabling
Required Tools and Supplies
For rack mount installations you will also require the following tools:
• Phillips #2 screwdriver
• Digital Milli-Ohm meter
• Rack screws (4 per device)
• Cable ties / cord retainers — to secure ground, power and interface
cabling
• Wire-strippers (for DC power cable)
• Fork terminal spade lugs (3 per DC power supply) — to install power
cabling to a DC system
• Power wire (14 AWG) — to install power cabling to a DC system
Note: Table 2-2 on page 2-9 provides a summary of the DC lugs that are
recommended for use with the 5150.

Installation 2-3
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Important Safety Information
Note: This unit has been designed and tested for installation in areas
prone to earthquakes (zone 4). To ensure proper operation it must be
installed in a proper frame.
WARNING: Read all installation instructions before connecting a 5150 device to a
power source.
WARNING: The chassis of the 5150 should never be opened under any
circumstances. Opening the chassis will void the warranty.
The system chassis must be returned to Ciena for service or replacement.
Power supply modules and transceivers are field-replaceable, however, the modules
or transceivers must be returned to Ciena for service or replacement.
WARNING: Before working on equipment that is connected to power lines, remove
jewelry (including rings, necklaces, and watches). Metal objects will heat up when
connected to power and ground and can cause serious burns or weld the metal
object to the terminals.
WARNING: Do not work on the system or connect or disconnect cables during
periods of lightning activity
WARNING: To prevent ESD damage to electronic components, always use an ESD
wrist strap when handling modules.
WARNING: This equipment is to be installed in a Restricted Access Location (RAL)
and maintained by qualified service personnel only.

2-4 Installation
5150 Service Aggregation Switch Hardware Installation and Start-up Manual
009-3222-001 Standard Revision H
Copyright©2012-2015 Ciena®Corporation July 2015
Note: Cabling and wiring that is part or the same physical installation,
even if it exits the building or enclosure for a short distance, should
generally be classified as intra-building.
Mounting the Device
The following installation options are available:
• Wall Mount
• Rack installation (19-inch frame or 23-inch frame)
• Desktop Installation
Before you start, ensure that the frame or mounting surface (wall mount
installations) is capable of supporting the weight of the system, SFPs and
cabling.
Wall Mount Installation
The wall mounting brackets are attached to the chassis, so that the chassis
can be mounted on a wall or other vertical surface. The wall mount bracket
does not contain any cable management features. See “Installing the
Wallmount Bracket” on page 8-5 for more information.
Note: For installations using the wallmount bracket, the hardware
required to attach the mounting bracket to the wall is Customer supplied.
In addition, the reinforced mounting surface should be capable of
supporting approximately 100 pounds. Please ensure that the hardware
usedincludestheproper fasteners/anchorsrequired to support theweight
of the unit.
See “To Install 5150 on a Wall” on page 2-15 for a high level procedure.
WARNING: Do not stack anything on top of this unit. The mounting brackets
provided with this unit are designed to support only the weight of this unit, if they fail
due to excess weight, it can cause bodily injury and damage the equipment.
WARNING: When installing the unit, ensure that the wiring meets the local electrical
code.
WARNING: All electrical interfaces on this product are intended for intra-building
connections only. These interfaces are designed as type 2 or type 4 ports as
described in GR-1089-CORE, Issue 4 and require isolation from the exposed outside
plant cabling.
Table of contents