SMR1-601-NC-PAR16
Installation Instructions ( New Construction)
Black
Black
White
White
Ground Ground
Wiring Diagram
Transformer Power
Install xture frame above ceiling (lines 1-4)
1. Cut a 3 1/4” Dia. Hole in Ceiling tile
2. Insert two hanger bars into the slots located on either side of the plaster frame.
The nail-in tabs point away from the xture. Repeat on the other side.
3. Fasten the hanger bars to the joist using screws or nails. The bottom of the bars should be ush with the
bottom of the joist. Slide the xture along the hanger bars to desired position and secure by depressing
one set of the plaster frame prongs together.
4. Feed the ex with the supply wires to the junction box. Make your electrical connections Black to
Black / White to White and replace snap-lock cover.
www.clartelighting.com 975 N. Todd Ave. Azusa, CA 91702 Tel. No. (626) 261-4242 Fax No. (626) 598-3750
READ AND FOLLOW ALL SAFETY AND INSTALLATION INSTRUCTIONS CAREFULLY.
TURN OFF ELECTRICAL POWER BEFORE STARTING INSTALLATION.
SAVE THESE INSTRUCTIONS