Clearfield StreetSmart Pre-Assigned FDH User manual

StreetSmart Pre-Terminated FDH Cabinet
Installation Manual ______________________________________________________
Manual 021814 REV A - Jan 2021

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
2
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
Table of Contents
Application 3
Description 3
Technical Specications 3
Mounting Base to Vault Lid 4
Mounting Cabinet to Base 6
Pole Mount Installation 7
Pre-Loaded Splitters 10
Connector Cleaning Procedure 11
Standard Warranty 16
Proprietary Notice 17
Technical Support 17

3
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
Application
Technical Specications
StreetSmart Pre-Terminated FDH Cabinet
Dimensions 22.72” T x 15.47” W x 14.18” D (577.08mm T x 393.94mm W x 360.17mm D) * Without Riser
Weight 40 lbs. (18.14 kg)
Dist. Port Density 144 or 288
Max. Feeder/Express Ports 12 or 24
Cable Entrances 4
Mounting Options (Hoist kits
included with each cabinet) Vault mount; pole mount; pad mount
Riser Base 6”; 8 lbs (127 mm; 2.72 kg)
12”; 12 lbs. (304.80 mm; 5.44 kg)
Pre-loaded WaveSmart High
Density Splitters with 900um Legs 4 or 8
Splitter Staging Capacity 72
Connector Modules 12 Pack Adapter Modules
Connector Types SC/UPC, SC/APC
Cable Types Indoor/Outdoor, Outdoor, Outdoor Armored, Ribbon and Loose Tube
Door Locks 2 per door
Venting Built-in Replaceable Roof Vent
Material 0.90 (2.286 mm) Aluminum with almond powder coating
Cleareld’s StreetSmart Pre-Assigned FDH PON Cabinet provides an interconnect
environment from the feeder network through the passive optical splitter to the
distribution network.
Designed for rapid PON Network deployments, these cabinets provide a single
distribution point to deploy FTTH in large scale MDU’s, urban or dense neighbor-
hoods. Pre-Assigned WaveSmart High Density 1 x 32 Splitters are loaded into the
cabinet with a pre-terminated ber tail, making installation and deployment very
cost and time effective.
Description
The StreetSmart Pre-Assigned FDH PON Cabinet provides a turn-key solution for up to 288 distribution bers for an outside
plant FTTx PON application. WaveSmart High Density 1 x 32 Splitters are installed and pre-assigned into Cleareld’s 12
pack SC/APC module adapters, allowing the service provider to instantly turn-up revenue-generating circuits.
The StreetSmart 288 PON Cabinet incorporates a cross-cut roof designed to shed water and includes a roof/solar shield
and a reusable/replaceable venting feature, providing additional protection for deployed ber. The outer shell of the cabinet
is replaceable, allowing the cabinet to be repaired if damaged. Mounting options include pad, pole or vault mounted with
either a 6” or 12” riser.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
4
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
Mounting Base to Vault Lid
1.
2.
3.
Remove the access door from the back of the cabi-
net base with a 7/16” socket or can wrench.
Remove the nuts from the threaded studs holding
the cabinet to the base and lift the cabinet from the
base.
Place the cabinet base over the hole in the vault lid.

5
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
4.
5.
6.
Place the rectangular washer plates over the
round cutouts in the cabinet base.
Insert the J-bolts through the base of the
rectangular washer plates, ensuring that the
J hook is hooked under a rib of the vault lid
underneath.
Using the washers, lock washers, and nuts
provided, secure the cabinet vase to the
vault lid.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
6
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
Mounting Cabinet to Base
1.
2.
3.
Feed the cables through the cabinet base and vault
lid as you lower the cabinet onto the base. Carefully
align all the threaded studs on the bottom of the
cabinet with the holes in the top of the base as you
seat it into place.
Using the provided washers and nuts, rmly secure the cabinet to the base.
Reinstall the base access door

7
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
Pole Mount Installation
1. Locate the hoist plate and install, using the included hardware, to the top of the cabinet on the side that will be
closest to the pole.
2. Locate the toothed bracket that has the mounting holes in the ange and mount it to the cabinet (below the previously
installed hoist plate) using the included hardware.
3. Determine the top height of the cabinet. Drill a 5/8” hole 8 inches below the anticipated height of the cabinet, all the way
through the pole.
Note: Cleareld does not provide the mounting hardware. Required hardware includes a 5/8” threaded rod (3” longer than
pole diameter), washers, lock washers, nuts and Lock Tight (red).
Note: 288 PON FSC cabinet shown for reference. Pre-Terminated FDH cabinet will be mounted to the pole using the same
method.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
8
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
4. Mount the loose toothed bracket to the pole using
threaded rod, washers avnd nuts on either side of
the pole. Rod length will depend on the diameter of
the pole. It is suggested to add 3” to the diameter
of pole for rod length.
Note: Cleareld does not recommend using lag bolts to mount cabinet to pole. Cleareld recommends using hardware with
a minimum of 5/8” diameter. Care should be taken to avoid over-tightening and deforming the hoist plate. Lock tight (red)
should be used on nuts to prevent loosening of nuts. Make sure the thread rod/nut does not exceed the top bend in bracket
or it will interfere with cabinet.
5. Lower the cabinet onto the pole mounted toothed
bracket until the hoist plate is over the ange of the
toothed bracket.

9
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
6. Level cabinet and drill 5/8” hole through lower bracket and pole, and install 5/8” rod, washers and nuts.
Note: Care should be taken to avoid over-tightening and deforming the hoist plate.
7. Cabinet Fully Mounted

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
10
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
Pre-Loaded Splitters
The StreetSmart Pre-Terminated FDH Cabinet will come with 1x32 WaveSmart
HD Splitters pre-insttalled. Splitter 1’s feeder leg will be connected to feeder
port 1, and its distribution legs will be connected to distribution ports 1-32.
Splitter 2 will connect to feeder port 2, and distribution ports 33-64, and so on,
for the number of splitters pre-installed in the ordered conguration.
If you wish to pull service from a pre-installed splitter leg, the connector can be
installed into one of the adapters in the provided staging plates.
Note: Splitter legs will be secured in place with a velcro strap around the radius
ngers.
Staging
Plates
Splitter
Cage
Distribution
Ports
Feeder
Ports

11
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
Inspect Then Connect
These are Cleareld recommended products/applications. Use the product
you feel will complete your cleaning procedures. Create a “best practice” for
your company and follow those procedures.
The use of Chemtronics end face and bulkhead cleaning products and
techniques ensures a clean end face, no matter the type of contamination.
Before cleaning any connector, be sure you know what type of contaminate
you are cleaning (dry, uidic, or combination). All the available products are
good, it’s the process that you need to be aware of. Using a dry cleaning
method to clean “dirt” can lead to scratching of the end face. Learn the
process of cleaning properly.
Note: It is NOT recommended to use isopropyl alcohol to clean the end face.
Cleaning an SC/LC Connector
Cleaning the End Face
• Place one wiping paper on QbE-2 FiberSafe™ Cleaning Platen.
(Figure 1)
• Apply small amount of precision cleaner (about 1” in diameter) with
Electro-Wash MX pen on to one end of the wipe. (Figure 2)
• Hold end face at a 90 degree angle. For APC connection, adjust by
slightly tilting the container or end face. Angle is correct when no drag is
felt on the end face. (Figure 3)
• Draw end face from wet to dry part of the wipe 3 times. Use just enough
pressure to ensure complete contact between end face and the wipe.
Note: DO NOT retrace previous step.
Figure 1
Figure 2
Figure 3
Connector Cleaning Procedure
Whether factory terminated or eld spliced, clean connectors are essential for proper system operation. Even the smallest
dust particle can cause transmission problems, so for optimal network performance inspect, and if necessary, clean
connectors and adapters prior to mating.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
12
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
Cleaning the Ferrule
• Lightly moisten the ber optic swab (2.5mm/38542F or 1.25mm/38040)
by spotting a small amount (about 1”) of Electro-Wash PX or
Electro-Wash MX pen onto the QbE. Hold the swab, 1 side down to the
wetted area and hold for a count of 1-2-3-4-5. (Figure 4)
Figure 4
Figure 5
Figure 6
Cleaning the Mate Through an Adapter AND the Adapter Itself
• Lightly moisten the ber optic swab (2.5mm/38542F or 1.25mm/38040)
by spotting a small amount (about 1”) of Electro-Wash PX or
Electro-Wash MX pen onto the QbE. Hold the tip of the swab onto the
wetted area and hold for a count of 1-2-3-4-5.
• Insert the swab into the adapter to the connector, press lightly against
the connector, twist 2-3 times, remove and discard.
• Dry with a second dry swab.
• Inspect, repeat cleaning if necessary, and test for signal strength.
• Use additional swabs to clean inside the actual adapter. Moisten
swab, like above, and insert through hole and remove while twisting.
(Figure 6)
• Insert swab into side of ferrule, wet side to the ceramic ferrule and
circle around 2-3 times and remove. Turn swab to dry side and repeat.
(Figure 5)

13
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
Male Connector
• Use of Chemtronics MTP Connector Cleaning Swabs (CC505F) is rec-
ommended. Even after cleaning with a probe cleaner, you should always
clean the pins with this (or an equivalent) type swab. Cleans ALL MTP/
MPO connector end faces. This swab also cleans the “pins” of the male
connector
• Lightly “spot” a QbE-2 wipe on the platen with Electro-Wash PX Fiber
Optic Cleaner, the FiberWash or MX Pen.
• Lightly touch short side of the MTP/MPO Connector Swab to the wetted
area (3-5 secs) to absorb some cleaning solution (DO NOT over saturate
the swab).
• Wipe connector areas to be cleaned, sliding pad from bottom of pad
across and forward to tip of swab, from 1 side to the other, turn over and
use long side to dry in same movement.
Cleaning an MPO/MTP Connector

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
14
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
• Use the hole on end of pad to
clean one alignment pin, then
press the end of the swab
into the other pin to clean.
• Check your work with a ber
scope. This can take several
attempts to get the endface
clean.
Female Connector (without pins)
• Cleaned like a single ber connector, using a cleaning platform. The
receptacles will be cleaned as long as you are using a combination clean-
ing process as recommended.
• Again, using a platen, moisten the platen with cleaning solvent on one
end to accommodate 3 swipes of the MPO female endface.
• Holding the connector (If APC, slightly at an angle to accommodate for 8°
angle) swiping with medium pressure, from the wet area into the dry area
3 times, without wiping over previous area.
• Inspect, and if clean, make the connection. If NOT, repeat above steps
until clean or if determined that the end face is damaged (based on stan-
dards of 5 cleanings per connection), replace.

15
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
Cleaning Using a Probe-Style Cleaning Tool
• The probe style cleaning tools are capable of cleaning a connector end face separately or through the adapter.
• Slightly engage probe by pulling back but do not allow to click. Lightly “spot” a QbE-2 wipe on the platen with Elec-
tro-Wash PX Fiber Optic Cleaner, this will help alleviate “over saturation” of the material.
• Lightly touch the tip of probe and release.
Wipe
Material
Wet
End
Face
Dry
• Insert connector or insert probe though adapter and click 2-3 times to move past the wet area and allow material to dry
wipe.
• Inspect connector, repeat if necessary (following standards)
• If cleaning a male connector, clean the pins (see above)

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
16
StreetSmart Pre-Terminated FDH Cabinet
Installation Manual _________________________________________________________
Manual 021814 REV A - Jan 2021
Standard Warranty
Cleareld warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and
service, subject to exceptions stated herein. Product purchased is warranted as follows: Cleareld designed and branded Products are warranted for
three (3) years: Products manufactured by Cleareld to customer prints and/or specications are warranted for one (1) year; and any Product Clear-
eld acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s
pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.
Warranty Claim Procedure
If any Product purchased from Cleareld is found defective under the above warranty, the following basic procedure must be followed:
1. Customer must contact Cleareld and obtain a Return Materials Authorization
2. Following authorization, the Customer ships the product-freight collect-to Cleareld’s manufacturing facility
3. Cleareld shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus-
tomer’s site, freight prepaid
Note: If the Product is not found to be defective by Cleareld, the product will be returned to the Customer and the customer billed for freight in both
directions.
View our warranty policy here: https://www.seecleareld.com/warranty.html
Limitations of Warranty
Correction of defects by repair or replacement, at the option of Cleareld Inc, shall constitute the exclusive sole remedy for a breach of this limited
warranty. Cleareld shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising
out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost prots, loss
of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon
principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or
exclusive remedy to achieve its essential purpose, or otherwise.
Cleareld will not be responsible for any labor or materials costs associated with installation or incorporation of Cleareld products at customer sites,
including any costs of alteration, replacement or defective product, or any eld repairs.
Other Limitations
Cleareld assumes no warranty liability regarding defects caused by:
1. Customer’s modication of Product, excepting installation activities described in Cleareld documentation
2. Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Cleareld, or any de-
fects suffered during shipping where the Product has been re-packaged
3. Customer’s installation or maintenance, excepting activities described in and performed in accordance with Cleareld documentation
4. Customer’s improper or negligent use or application of Product
5. Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil
commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Cleareld
6. Environmental factors and weathering resulting in aging and damage not necessary or applicable to the function of the product

17
StreetSmart Pre-Terminated FDH Cabinet
__________________________________________________________ Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 021814 REV A - Jan 2021
Proprietary Notice
Information contained in this document is copyrighted by Cleareld, Inc. and may not be duplicated in full or part by any person without prior written
approval of Cleareld, Inc.
Its purpose is to provide the user with adequately detailed documentation to efciently install the equipment supplied. Every effort has been made to
keep the information contained in this document current and accurate as of the date of publication or revision.
However, no guarantee is given or implied that the document is error free or that it is accurate with regard to any specication.
Technical Support
Cleareld, Inc. can be contacted for any issues that arise with the supplied product.
If you need to return the supplied product, you must contact the Cleareld, Inc. Customer Service Department to request a Returned Materials
Authorization (RMA) number.
Cleareld, Inc.
7050 Winnetka Ave N
Minneapolis, MN 55428
Toll Free: 800.422.2537
Phone: 763.476.6866
Fax: 763.475.8457
Customer Support: sales@seecleareld.com
Technical Support: techsupport@seecleareld.com
Table of contents
Other Clearfield Enclosure manuals
Popular Enclosure manuals by other brands

Abysm Gaming
Abysm Gaming EBONY RGB DEEP Series user manual

Pulsar
Pulsar 17/TRZ75/SATEL/GRADE3 manual

Watec
Watec APAQ2000 Series Installation and operating instructions

Riotoro
Riotoro MORPHEUS manual

Giacomini
Giacomini GE551 Datasheet / Operating Instructions

Eterna
Eterna LEDTWNSPOT Installation instructions manual