manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cleveland
  6. •
  7. Convection Oven
  8. •
  9. Cleveland SteamChef 3 User manual

Cleveland SteamChef 3 User manual

Cleveland
™
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
SECT.BPAGE 15
0707
SteamChef TM 3&6
High Speed Convection Steamer,
Automatic Water Fill & Drain, One 45,000 & One
62,000 BTU Gas Boiler-Free Counter Type Design
Cleveland Standard Features
n
Cooking capacity for up to three 12" x 20" x 2.5" deep steam table
pans (1/1 G/N, 65 mm) for the upper compartment and six pans for
the lower compartment.
n
High-speed gas convection steamer with open style 1.5 gallon
water reservoir located at the bottom of the cooking compartment
for easy access and maintenance.
n
Fan forced convection steam with patented KleanShield
TM
cooking
compartment design. KleanShield
TM
collects and removes
condensate waste from the cooking compartment. This keeps the
compartment clean, safe from impurities and easy to maintain.
Reduces foaming and avoids contamination of the reservoir water.
n
Automatic water level controls, fills when main power switch is
turned ON, Low Water and High Water probes inside cooking
compartment maintains water levels during cooking, eliminating the
need to manually refill and monitor water level during cooking.
Large overflow port in rear wall. 193˚preheat and standby
temperature. High Temperature Safety Shut-off.
n
Steam and Fan Shut Off Control when compartment door is
opened.
n
45,000 BTU high efficency atmospheric gas boilerless style heating
system for the upper compartment and 62,000 BTU for the lower
compartment.
n
Front acess works in a drawer style burners for easy servicing.
n
Includes a 60-Minute Electro-Mechanical Timer, LED Indicator
Lights for Power On and Reset. Timed and Manual Bypass Switch
for constant steaming.
n
Exclusive SteamChef
TM
Automatic Drain Control. Compartment
drains when main power is turned OFF via 1/2" ball valve with micro
switch circuitry. Simple 1" NPT drain connection required with water
saving cold water condenser and 3 minute rinse feature.
n
Left Hand Door Hinging: Compartment Doors hinged on the left,
controls on the right.
n
Exclusive, durable 14 gauge stainless steel compartment door and
latch withstands abuse and heavy wear. Two piece compartment
door with free floating inner door is self adjustable and prevents
leaks. Reversible door gasket doubles the life of the gasket.
n
Heavy-duty 4" (102mm) Skid Resistant Adjustable Legs with
Flanged Feet.
n
UL - Gas, UL - Sanitation (NSF Standards).
Shall be a Cleveland
SteamChef TM 3 & 6
, model (2) 22CGT3/6, two
stacked single compartment (45,000 BTU upper and 62,000 BTU lower) high
efficency atmospheric gas boilerless style heating system. Front acess
"works in a drawer" style burners for easy servicing. Standard 60-minute
electro-mechanical timers. Capacity for three 2.5" (1/1 G/N, 65 mm) full size
steam table pans for the upper compartment and six pans for the lower
compartment. Includes 1/2" ball valve style automatic drains. Automatic
water level controls. Heavy-duty 14 gauge stainless steel cooking
compartment doors and latches. KleanShield
TM
clean cavity protection.
Requires field installation. Includes Stacking Stand, Gas Flue Exhaust Kit and
Common Drain and Water Connection Manifold.
Short Form Specifications
MODEL: c(2) 22CGT63
n
Stacking combination requires field installation of the steamers,
stand and flue. This combination includes the following items:
• ES263044 Stacking Stand (PN 111467G)
• Gas Flue Exhaust Kit
• Common Drain and Water Connection Manifold
Options & Accessories
p5 Foot (1524mm) FDA Approved National Hose Thread style water
connection kit (garden hose thread), 2 required (NHT60)
pSingle Point Water Connection (SPW)
By
STEAMCHEF™ BOILERLESS
CONVECTION STEAMERS
(NOT TO SCALE)
SECT.BPAGE 16
0707
Litho in U.S.A.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are
U.L/NSF#4 and CSA (AGA, CGA).
25.50"
648mm
29.25"
743mm
2.68"
68mm
38.84"
987mm
92º 90º
54.94"
1395mm
25.50"
648mm
29.25"
743mm
2.68"
68mm
38.84"
987mm
92º 90º
54.94"
1395mm
25.50"
648mm
29.25"
743mm
2.68"
68mm
38.84"
987mm
92º 90º
54.94"
1395mm
65.06"
1653mm
25.50"
648mm
38.84"
987mm
38.84"
987mm
38.93"
989mm
61.60"
1565mm
25.75"
654mm
20.11"
511mm
16,41"
417mm
8.49"
21.6mm
2.68"
68mm
2.02"
51mm
4.68"
119mm
4.83"
123mm
4.83"
123mm
2.02"
51mm
2.02"
51mm
61.60"
1565mm
25.79"
655mm
20.11"
511mm
16.40"
417mm
8.39"
21.3mm
2.68"
68mm
61.63"
1565mm
25.79"
655mm
20.11"
511mm
16,41"
417mm
8.38"
213mm
3.26"
83mm
2.64"
67mm
43.57"
1107mm
7.73"
196mm
65.06"
1653mm
25.50"
648mm
43.57"
1107mm
7.73"
196mm
65.06"
1653mm
25.50"
648mm
43.57"
1107mm
7.73"
196mm
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
C
C1
C
C2
D
G
G
OPERATING CLEARANCES
3" Left, 3" Right and 3" Rear.
SERVICE CLEARANCES
12" on control side. Contact factory for variances to clearances.
CONTROLS
(per compartment)
60-minute electro mechanical timer with load compensating feature.
Three function control switch for Timed Cooking and Continuous Steaming.
APPROVALS
UL - Gas, UL - Sanitation (NSF Standards)
GAS
(one connection per unit)
1/2” Dia. IPS
45,000 & 62,000 BTU’s
S
SU
UP
PP
PL
LY
YP
PR
RE
ES
SS
SU
UR
RE
E:
NATURAL - 4.00’ W.C. minimum, 14.00” W.C. maximum
PROPANE - 12.00” W.C. minimum, 14.00” W.C. maximum
Manufacturer must be notified if unit will be used above 2,000 ft. altitude.
ELECTRICAL
(one connection per unit)
115V, 1 Phase, 35 Watts.
COLD WATER
C
C1
1: Condensing Water Inlet, 35 Psi Minimum, 60 Psi Maximum.
C
C2
2: Fill Water Inlet, 35 Psi Minimum, 60 Psi Maximum.
Two 3/4" NH-F (Garden Thread) connections. Use NSF approved hose.
DRAIN CONNECTION
1" NPT-M
Do not connect other units to this drain.
Drain line must be vented. Vented drain connection included.
Do not connect drain to PVC pipe.
H
D
C
C1 C2
H
D
C
C1 C2
Top compartment has capacity for:
Three, 12" x 20" x 21⁄2" deep Cafeteria Pans
or
Six, 12" x 20" x 1" deep Cafeteria Pans.
or
Two, 12" x 20" x 4" deep Cafeteria Pans
Bottom compartment has capacity for:
Six, 12" x 20" x 21⁄2" deep Cafeteria Pans.
or
Twelve, 12" x 20" x 1" deep Cafeteria Pans.
or
Four, 12" x 20" x 4" deep Cafeteria Pans

Other manuals for SteamChef 3

3

This manual suits for next models

4

Other Cleveland Convection Oven manuals

Cleveland Convotherm Combination Oven-Steamer Electric... Building instructions

Cleveland

Cleveland Convotherm Combination Oven-Steamer Electric... Building instructions

Cleveland BMR-32 User manual

Cleveland

Cleveland BMR-32 User manual

Cleveland Combi Oven-Steamer OGB-10.20 User manual

Cleveland

Cleveland Combi Oven-Steamer OGB-10.20 User manual

Cleveland ConvectionPro Steamers 36CGM16 User manual

Cleveland

Cleveland ConvectionPro Steamers 36CGM16 User manual

Cleveland BMR-32 User manual

Cleveland

Cleveland BMR-32 User manual

Cleveland Convotherm OGS-20.20 Building instructions

Cleveland

Cleveland Convotherm OGS-20.20 Building instructions

Cleveland SteamCraft 21-CGA-5 User manual

Cleveland

Cleveland SteamCraft 21-CGA-5 User manual

Cleveland Combi Oven-Steamer OGS-6.10 User manual

Cleveland

Cleveland Combi Oven-Steamer OGS-6.10 User manual

Popular Convection Oven manuals by other brands

Avanti TD-25 instruction manual

Avanti

Avanti TD-25 instruction manual

Bartscher AT 110 manual

Bartscher

Bartscher AT 110 manual

Lincoln Impinger 3270 CE Parts & service manual

Lincoln

Lincoln Impinger 3270 CE Parts & service manual

Toastess TO-300 Instruction booklet

Toastess

Toastess TO-300 Instruction booklet

Blodgett Zephaire FA-100 Installation, operation and maintenance

Blodgett

Blodgett Zephaire FA-100 Installation, operation and maintenance

Moffat WALDORF RN8510GC Technical data sheet

Moffat

Moffat WALDORF RN8510GC Technical data sheet

Maksan MKF-20G Installation, operation and maintenance manual

Maksan

Maksan MKF-20G Installation, operation and maintenance manual

ASBER AECO-1 Manual instruction

ASBER

ASBER AECO-1 Manual instruction

Blodgett Mark V Installation operation & maintenance

Blodgett

Blodgett Mark V Installation operation & maintenance

IKEA IBS550P Use & care guide

IKEA

IKEA IBS550P Use & care guide

Adcraft coh-2670w Operation manual

Adcraft

Adcraft coh-2670w Operation manual

Moffat Blue Seal Evolution Series E56D Technical data sheet

Moffat

Moffat Blue Seal Evolution Series E56D Technical data sheet

Panasonic NN-C980B, NN-C988B operating instructions

Panasonic

Panasonic NN-C980B, NN-C988B operating instructions

Cres Cor CO-151-HW-UA-6B Specifications

Cres Cor

Cres Cor CO-151-HW-UA-6B Specifications

Jenn-Air W122 use and care manual

Jenn-Air

Jenn-Air W122 use and care manual

Cres Cor CO151FWUA12DE2081 Installation, operation and maintenance manual

Cres Cor

Cres Cor CO151FWUA12DE2081 Installation, operation and maintenance manual

Vulcan-Hart VCH16 ML-126367 Installation & operation manual

Vulcan-Hart

Vulcan-Hart VCH16 ML-126367 Installation & operation manual

Hendi 227077 manual

Hendi

Hendi 227077 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.