EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cleveland
  6. •
  7. Water Pump
  8. •
  9. Cleveland AFF-950-FTP User manual

Cleveland AFF-950-FTP User manual

Other Cleveland Water Pump manuals

Cleveland P-FTP-100 User manual

Cleveland

Cleveland P-FTP-100 User manual

Cleveland AFF-1150-FTP User manual

Cleveland

Cleveland AFF-1150-FTP User manual

Cleveland TP User manual

Cleveland

Cleveland TP User manual

Popular Water Pump manuals by other brands

Neptun NPHW 5500 operating instructions

Neptun

Neptun NPHW 5500 operating instructions

Sensidyne Gilian BDX-II Operation & service manual

Sensidyne

Sensidyne Gilian BDX-II Operation & service manual

Draper 47808 instructions

Draper

Draper 47808 instructions

Trolla 12820 manual

Trolla

Trolla 12820 manual

Sunfab SVH Series installation guide

Sunfab

Sunfab SVH Series installation guide

WilTec 50740 Operation manual

WilTec

WilTec 50740 Operation manual

Fieldmann FVC 5015 EK user manual

Fieldmann

Fieldmann FVC 5015 EK user manual

Everbilt EFSUB5-122HD Use and care guide

Everbilt

Everbilt EFSUB5-122HD Use and care guide

Graco Husky 3300e manual

Graco

Graco Husky 3300e manual

esotec 101018 operating manual

esotec

esotec 101018 operating manual

Becker BASIC VASF 2.80/1-0.AC230 operating instructions

Becker

Becker BASIC VASF 2.80/1-0.AC230 operating instructions

Sykes AmeriPumps GP100M Operation and maintenance instructions

Sykes AmeriPumps

Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX XP WX Series user manual

DUROMAX

DUROMAX XP WX Series user manual

BRINKMANN PUMPS SBF550 operating instructions

BRINKMANN PUMPS

BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric IPS Installation & operation manual

Franklin Electric

Franklin Electric IPS Installation & operation manual

Xylem e-1532 Series instruction manual

Xylem

Xylem e-1532 Series instruction manual

Milton Roy PRIMEROYAL instruction manual

Milton Roy

Milton Roy PRIMEROYAL instruction manual

STA-RITE ST33APP owner's manual

STA-RITE

STA-RITE ST33APP owner's manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

SECT. XIV PAGE 29
0707
FOOD TRANSFER PUMP
REQUIRED FOR OPERATION
WITH CYCLE-MATIC
VERTICAL FORM-FI
LL-SEAL MACHINE
MODEL:
c
AFF-950-FTP
Cleveland Standard Features
nAir powered, mobile piston style food transfer pump
with Air and Electrical quick disconnect hookups for
use with the Cycle-Matic Form-Fill-Seal Machine.
nNo additional Air or Electric required if used with
Cycle-Matic Form-Fill-Seall Machine
nPump housing and base are constructed of stainless
steel
nBase mounted on (4) 4" diameter lockable swivel
casters
nManual volume adjustment from 32 oz. to 128 oz. per
stroke (1 quart to on gallon)
nElectrical components, mounted in splash proof
stainless steel housing
nOperation controlled from Cycle-Matic Form Fill
Machine touch screen
nThree-way air operated outlet control valve
nQuick disassembly for ease of cleaning
nAccepted for use in U.S.D.A. Inspected Facilities
Options & Accessories
pCleaning brushes
p3" diameter suction food transfer hoses (specify length)
p2" diameter discharge food transfer hoses
pCycle-Matic, Vertical Form-Fill-Seal machine
.
Shall be CLEVELAND Model AFF-950-FTP AIR OPERATED
FOOD TRANSFER PUMP with; Pump housing and base con-
structed of stainless steel; Base mounted on (4) 4" diameter lock-
able swivel casters; Manual volume adjustment from 32 oz. to
128 oz. per stroke; Electrical components, mounted in splash
proof stainless steel housing; Operation controlled from Cycle-
Matic Form-Fill-Seal Machine touch screen; Three-way air operat-
ed outlet control valve; Quick disassembly for ease of cleaning.
Short Form Specifications
Cleveland
™
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
COOK CHILL SYSTEMS Cook/Chill Systems
SECT. XIV PAGE 1
1201
Litho in USA
Cleveland Range reserves right of design improvement or modification, as warranted.
SECT. XIV PAGE 30
0707
Litho in USA
56.50"
1435mm
21.06"
535mm
45.13"
1146mm
95.50"
2426mm
40.00"
1016mm
35.63"
905mm
CLEARANCE
TO REMOVE
VALVE ASSY.
15.00"
381mm
81.19"
2062mm
PRODUCT
FROM FOOD
TRANSFER
PUMP
2"
TRI-CLAMP
CONN.
61.75"
1569mm
32.5"
826mm
10.25"
260mm
28.00"
711mm
18.00"
457mm
32.38"
823mm
PRODUCT
FROM
KETTLE
PRODUCT TO
AFF-950
3” ACME THREADED
CONNECTION
(optional)
AIR SUPPLY HOSE
TO AFF-950
85 PSI MAX
NO EXTRA AIR
REQUIRED
AIR SUPPLY HOSE
TO AFF-950
85 PSI MAX
NO EXTRA AIR
REQUIRED
CONTROL CABLE
TO AFF-950
CONTROL PANEL
NO EXTRA POWER
REQUIRED
CONTROL CABLE
TO AFF-950
CONTROL PANEL
NO EXTRA POWER
5.31"
135mm
2” TRI-CLAMP
CONNECTION
3
1
1
2
2
4
4
A
19.00"
487mm
MOTOR POWER
CABLE TO
AFF-950 CONTROL PANEL
NO EXTRA POWER
REQUIRED
MOTOR POWER
CABLE TO
AFF-950
CONTROL BOX
NO EXTRA AIR
REQUIRED
AIR SUPPLY HOSE
TO AFF-950
85 PSI MAX
AIR SUPPLIED FROM CYCLEMATIC
NO EXTRA AIR REQUIRED
AIR SUPPLY HOSE
FOR EXITING CONVEYOR
EXITING CONVEYOR
MOTOR POWER CABLE
FOOD TRANSFER
PUMP
CONTROL CABLE
AIR SUPPLY HOSE
FOR FOOD
TRANSFER PUMP
HOSE HOOKUP
FROM FOOD
TRANSFER PUMP
TO AFF-950
AIR QUICK DISCONNECT
FOR EXITING CONVEYOR
FOOD TRANSFER
PUMP
CONTROL CABLE
CONNECTION
EXITING CONVEYOR
MOTOR POWER CABLE
CONNECTION
AIR QUICK DISCONNECT
FOR FOOD PUMP
OFF
8.25" MIN.
(210mm)
25.50" MAX.
(648 mm)
29.75"
(756 mm)
66.25"
1683mm
25.25"
641mm
13.25"
337mm
17.50"
438mm
33.75"
857mm
MUSTBEPULLED
OUTTORUN
PUSHTOSTOP
CONTROL
POWER
OFF ON
FILM CART
WITH STOCK
FILM ROLL
MUSTBEPULLED
OUTTORUN
PUSHTOSTOP
CONTROL
POWER
OFF ON
43
2
1
(NOT TO SCALE)