Thank you for purchasing our product. We trust it will give you comfort and convenience.
The cooler is a high-tech product, showing simplicity and outstanding reliability, due its European design
origin.
Its working principle is that water evaporation uses up the surrounding heat and causes the
temperature to cool down.
When water is continuously distributed onto the cooling pad surface, the air being drawn through the
pad the water to evaporate makes the air cooler and fresher. The circulating water moves down to the
reservoir, where it’s again pumped up by the water pump. If the hose option is being used (supplied as
standard), a float valve keeps the reservoir full continuously. If filled manually, the big 100 Liter capacity
reservoir ensures hours of interrupted operation. There is a digital level indicator to quickly check the
amount of water remaining.
APPLICATIONS__________________________________________________________________
This cooler is currently being used in many different industries and applied in many countries.
(Company offices, shops, hospitals, schools, workshops, workers dormitories, outdoor teahouse/coffee
bars, restaurants, recreation facilities.)
Manufacturing:
Textile, machinery, ceramic, refined chemical industries, metallurgy, hardware and leather industries.
Industrial processing:
Electronics, clothes & shoe making, plastics, food industries, packaging.
Others:
Indoor sports courts, bakeries, playgrounds, laundries, kitchens, vegetable markets, gymnasiums,
underground parking lots, greenhouses, chicken and pig farms, gardens. The list goes on. . .
-01-
(CM-30000AP) Manual
www.climateplus.ae
SPECIFICATIONS________________________________________________________________
MODEL
cm-30000ap
Max Airflow (m3/h)
23,000
Power Supply/ Frequency
220V/50Hz
Power Consumption (W)
1100
Rate
Three speed
Water Capacity (L)
200
Dimension (L*W*H) (mm)
1600*780*1800
Weight (kg)
105
Effective Cooling Area(m2)
260
TECHNICAL FEATURE___________________________________________________
-02-
(CM-30000AP) Manual
www.climateplus.ae
IMPORTANT REMINDERS_________________________________________________________
Please read the manual carefully before operating the cooler.
A). Operating conditions:
1- Temperature: 18°C to 45°C; Water temperature: <45C.
2- Power supply must not exceed the required voltage (+/-) 5%.
3- Air supply must be largely free of dust or extra cleaning is required.
B). Protect the power cable from vehicle or foot traffic. Connection to incorrect electric voltage, or
faulty installation, will cause danger of electric shock.
C). other tips for cooler use:
1-Keep doors and windows open to allow fresh air to enter, and treated air to exit, when cooler is
operating.
2-Flashing red light on the control panel means water level in reservoir is low.
3- Rinse the reservoir with fresh water and clean prior to use after a period when the cooler has not
been in operation.
4- Take care when moving the cooler, especially when it is full of water. Pushing too hard will cause the
cooler to overbalance and tip over, which may cause injury and will damage the cooler.
5-To prevent buildup of algae and other biological organisms in the reservoir, regularly add
chlorine/bromine tablets as per tablet manufacturer recommendation for evaporative cooler reservoirs.
-03
(CM-30000AP) Manual
www.climateplus.ae
KEYCOMPONENTS____________________________________________________
-04-
(CM-30000AP) Manual
www.climateplus.ae
OPERATION INSTRUCTION_____________________________________________________
WARNING
1. All electrical repairs must only be carried out by a suitability qualifies electrician, after all
power is disconnected.
2. All the instructions state that the guard has to be removed for cleaning purpose, the instructions shall
state the substance of following: ensure that the fan is switched off from the supply mains before
removing the guard.
3. This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lock of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play the appliance.
4. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
5. Water Pressure: 0.1 Mpa (+/-) 10%.
Keypad
Instruction
Comment
ON/OFF
This turs the cooler on or off.
COOL
This activates the cooling function. Note that there is a
delay of one minute before the fan starts while the cooling
pads wet up
SPEED
Pressing SPEED will select low, medium or high fan speed
SWING
This activates/deactivates swing function.
TIMER
Delayed Start
This timer setting can be used to start the cooler after a
certain number of hour’s delays. When only the green
POWER light is on, press TIMER until the number of hours
delay (1-24) is shown.
TIMER
Automatic Stop
When the cooler is already going, press timer to set the
number of hours (1-24) until the machine will
automatically switch off.
WATER Supply
Use only clean, fresh water.
Pour water into the water inlet on the right hand side of
the unit (max 100L). Alternatively, attach a hose to the
water inlet on the left side for automatic filling. Note as
pressure reducing valve is recommended for a high
pressure water supplies.
-05-
(CM-30000AP) Manual
www.climateplus.ae
-06-
(CM-30000AP) Manual
www.climateplus.ae
MAINTENANCE_____________________________________________________
For best results and long term operation, regular maintenance is essential.
To ensure the cooler delivers fresh and clean air, regularly change the water when dirty, and clean
both the dust filter and the cooling pad.
1) Remove the filter pad by unscrewing the 4 screws on the rear of the cooler. Then lift the pad and pull
out the bottom to release. To replace the pad, slide up into the slot under the top of the cooler, push in
at push in at the bottom; and allow dropping into the lower slot.
2)Clean the pad from the inner-side to out-side of pad (inner side is towards motor). Never use any
liquid detergent. Never use pressurized water, as it may damage to the pad.
3)Unscrew the drainage lid to let dirty water flow out, the clean the water tank thoroughly with a soft
cloth. Wash off dirt on the sensor, water pump and the float valve. Rinse thoroughly.
4)Use mild soap and soft clean cloth when cleaning the cooler casing. Do not use any caustic chemical
detergent that may cause damage to the surface of the cooler.
5)To prevent buildup of algae and other biological organisms in the reservoir, regularly add
chlorine/bromine tablet manufacturer recommendation for evaporative cooler reservoirs.
-07-
(CM-30000AP) Manual
www.climateplus.ae
MAINTENANCE_________________________________________________________________
Malfunction
Reason
Remedy/Solution
-Operating screen
Stays dark
-No power
-Main control board
failure
-Fuse is blown
-panel failure
-Check unit is plugged
in
-Change control
board
-Change fuse
-Change panel
-Display is normal
but without air
flow or the air
speed is too low
-The fan is jammed
-Cooling pad or dust
filter is blocked
-Main control board
failure
-Check to ensure
there is nothing
preventing free
rotation of the fan
-Clean the cooling
pad and dust filter
-Change the main
control board
-Motor does not
Respond to
control Panel
-Main control board
Failure
-Panel failure
-Change the main
control board
-Change panel
-Water leaking
From drain valve
-Drain valve is loose
-Dirt in valve
-Change the main
control board
-Change panel
-Air diffuser/swing
-Function not
working
-Synchronous motor
is burnt out
-Crankshaft is
broken
-Change synchronous
motor
-Change crankshaft
-Water drops
splash
Out of the air
diffuser
-Water pipe has
come loose
-Check water pipe to
top of filter pad and
reattach or tighten
as necessary
NOTE: This troubleshooting is for reference purposes only. If any technical assistance is needed, Please
contact your distributer for service/repair
-08-

Popular Accessories manuals by other brands

ZMI PowerPack 20K Pro user guide

ZMI

ZMI PowerPack 20K Pro user guide

Eagle F321 product manual

Eagle

Eagle F321 product manual

xtorm DS200 user manual

xtorm

xtorm DS200 user manual

Shel lab SCO6AD-2 Installation & operation manual

Shel lab

Shel lab SCO6AD-2 Installation & operation manual

Emerson Rosemount 328A Reference manual

Emerson

Emerson Rosemount 328A Reference manual

Philips SWL6163W Specifications

Philips

Philips SWL6163W Specifications

Homelite PS04988 Assembling instructions

Homelite

Homelite PS04988 Assembling instructions

M&C LC Series instruction manual

M&C

M&C LC Series instruction manual

SBI AC01336 installation instructions

SBI

SBI AC01336 installation instructions

Antelope Zen Go Synergy Core user manual

Antelope

Antelope Zen Go Synergy Core user manual

TaoTronics TT-AD001 user manual

TaoTronics

TaoTronics TT-AD001 user manual

AOSafety AOTuffMaster H24M brochure

AOSafety

AOSafety AOTuffMaster H24M brochure

Dixon Bayco FT394 Maintenance & Operating Instructions

Dixon Bayco

Dixon Bayco FT394 Maintenance & Operating Instructions

Smiley Daisy Love In A Mist user manual

Smiley Daisy

Smiley Daisy Love In A Mist user manual

Sealcom KAKADU Programming manual

Sealcom

Sealcom KAKADU Programming manual

Teracom TSH230 user manual

Teracom

Teracom TSH230 user manual

Hama MagPower 5 operating instructions

Hama

Hama MagPower 5 operating instructions

Craftsman Door Kit Operator's manual

Craftsman

Craftsman Door Kit Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.