Code Blue CB 4 Series Service manual

800.205.7186 •www.codeblue.com
Administrator Guide
Installation | Configuration | Operation | Troubleshooting
CB 4 Series

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 2 of 65
CB 4 Series
Administrator Guide
WARNING
ONLY QUALIFIED PERSONNEL SHOULD INSTALL THESE UNITS. THE INSTALLATION
SHOULD CONFORM TO ALL LOCAL CODES. IN SOME COUNTRIES, A CERTIFIED ELECTRI-
CIAN MAY BE REQUIRED.
NOTICE TO USERS
Copyright © Code Blue Corporation. All rights reserved. This guide or software described herein, in
whole or part, shall not be reproduced, translated or reduced to any machine-readable form without
prior written approval from Code Blue Corporation.
CODE BLUE CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS GUIDE, THE
SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DIS-
CLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICU-
LAR PURPOSE WITH REGARD TO THIS GUIDE, THE SOFTWARE OR SUCH OTHER INFORMA-
TION. IN NO EVENT SHALL CODE BLUE CORPORATION BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL, OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR
OTHERWISE, ARISING OUT OF OR IN CONNECTIONS WITH THIS GUIDE, THE SOFTWARE
OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF.
Code Blue Corporation reserves the right to make any modications to this guide or the information
contained herein at any time without notice. The software described herein may also be governed
by the terms of a separate user license agreement.
Code Blue®is a registered trademark of Code Blue Corporation.

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 3 of 65
CB 4 Series
Administrator Guide
Table of Contents
(NOTE: Phone programming instructions can be found in the IP5000 and IA4100 Guides.)
Section Page
2 Introduction..........................................................................................5
3 Getting Started.....................................................................................7
4 Spare Parts...........................................................................................9
5 Power Requirements..........................................................................11
6 Legacy Power Requirements.............................................................14
7 Software Conguration...................................................................... 16
8 CB 4-s Low Voltage Exploded View..................................................17
9 CB 4-r Low Voltage Exploded View.................................................. 18
10 CB 4-s with Dual Faceplates Low Voltage Exploded View............. 19
11 CB 4-u Low Voltage Exploded View................................................. 20
12 CB 4-u High Voltage Exploded View................................................. 21
13 How to Replace LED Light Connectors............................................22
14 CB 4-s Installation Instructions........................................................ 24
15 CB 4-s with Dual Faceplates Installation Instructions.................... 26
16 CB 4-r Installation Instructions......................................................... 28
17 CB 4-u Installation Instructions........................................................ 30
18 CB 4 Series Remote Mount Beacon/Strobe Installation................. 33
19 S-1000/S-1050 Installation Instructions.............................................34
20 PoE Installation Instructions..............................................................36
21 CB 4 Series Pole Mount Installation Instructions............................37
22 CB 4 Series Curb Mount Installation Instructions...........................38
23 CB 4-u Solar Installation Instructions...............................................40
24 CB 4 Series 24V Standard Wiring (2020)..............................................41
25 CB 4 Series PoE Wiring (2020)..............................................................42
26 CB 4 Series 24V Standard Wiring (2015-2020)........................................43
27 CB 4 Series 24V Standard Wiring (prior to 2015).....................................44
28 CB 4-u 24V or Multi-Tap Power Brick Wiring (prior to 2015)...................45
29 CB 4-u Series Standard Wiring (after 2015) (with 24V Fuse Block)...................46
30 CB 4-u Series Standard Wiring (prior to 3/2013) (with Hammond Transformer).....47
31 CB 4-u Series Standard Wiring Diagram (after 2015) (with Triad Transformer).48

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 4 of 65
CB 4 Series
Administrator Guide
32 GSM Wireless Wiring Diagram (CB 4-u only)............................... 49
33 Cellular Retro Instructions (CB 4-u only)......................................50
34 Solar and WindAssist Wiring Diagram (CB 4-u only).................. 55
35 NightCharge®Wiring Diagram (CB 4-u only)................................ 56
36 WM-180 Wall Mount Installation Instructions.............................. 57
37 WM-180 Pole Mount Installation Instructions.............................. 60
38 Maintenance Schedule................................................................... 61
39 Locating Unit Serial Numbers........................................................63
40 Warranty........................................................................................... 64
41 Download Information.................................................................... 65

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 5 of 65
CB 4 Series
Administrator Guide
2 Introduction
The 4 Series Wall Mount Enclosures
Thank you for choosing the CB 4 Series for your Code Blue application.
The CB 4 Series is our basic communication unit designed for wall or pole installations in interior
and exterior applications. The all-steel housing and Code Blue’s speakerphone system meet the
need for a highly vandal resistant unit, while providing a cost-effective and reliable solution.
The CB 4 Series is a good choice for dorm and building entrances, hallways and transit centers.
The exclusive analog InterAct and VoIP speakerphones are designed for maximum reliability, vandal
resistance, auxiliary functions, mass notication control, and fault monitoring and reporting capabili-
ties. (see IA4100 or IP5000 guides for more information on our speakerphones)
Our unmistakable craftsmanship makes our enclosures the most rugged on the market, withstand-
ing the punishment of natural and man-made disasters. CB 4 Series units have a rugged steel
construction, industrial engineering grade reective graphics and weather, UV and grafti resistant
paint.
Other options include:
• IP and analog phones
• Low power consumption LED faceplate light
• 180° Public Address Speaker (PAS)
• Remote Mount Beacon/Strobe
• GSM – CB 4-u Only
• NightCharge®– CB 4-u only
• Solar – CB 4-u only
• Directory Plate
• Color IP Camera – CB 4-s with Dual Faceplates only
• Custom Cut-out Stainless Steel Plate – CB 4-u only

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 6 of 65
CB 4 Series
Administrator Guide
This guide contains all of the Code Blue CB 4 Series information for the CB 4-s, CB 4-u, and CB 4-r.
This guide contains a general overview of the CB 4 Series options and its application, installation
and wiring.
CB 4-u
CB 4-u
CB 4-s with
Dual Faceplates
CB 4-s with
CB 4-s
CB 4-s
CB 4-s
CB 4-r
CB 4-r

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 7 of 65
CB 4 Series
Administrator Guide
3 Getting Started
Basic Install Instructions
1. EIA/TIA, ANSI, CSA and BICSI cabling or similar standards shall be adhered to for proper
operation of Code Blue communication devices connected to copper or ber infrastructures.
Communications cable and electrical cable in the same conduit is not an acceptable instal-
lation and shall not be supported. Analog phones require a minimum of 23mA for proper
operation (26-29mA recommended).
2. Each analog speakerphone requires its own phone line or PBX extension. Multiple units
shall not be supported.
3. Speakerphones require programming before operation. Consult the User Guide or Admin-
istrator Guide enclosed with the unit or go to www.codeblue.com > Support > Downloads to
read or download manuals.
4. If you are installing IP speakerphones, please read the appropriate manuals and consult
with your Network Administrator.
5. Size electrical wiring based on length of run.
6. Consult the enclosed document packet for internal wiring instructions.
What’s Included
Quantity Part Description
1 Wall Anchor Kit - 4-3/8 Bolts, 4-Washers, 4-Rubber Washers 4-Cement Anchors
1 Security Bit
1 Enclosure
1 Access Plate – CB 4-u Only
1 URL listing sheet of Installation, Programming, Wiring & Warranty locations
1 Blank Stainless Steel Plate - CB 4-s with Dual Faceplates only
2 40 amp Batteries – CB 4-u Solar only
1 Solar Panel Assembly – CB 4-u only

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 8 of 65
CB 4 Series
Administrator Guide
Tools Required
CB 4-s and CB 4-r
1. Ladder to reach above unit – For Remote Beacon/Strobe Only
2. Drill and security bit for removing and inserting security screws on phone
3. 3/8 socket set to mount unit onto wall
CB 4-u
1. Ladder to reach above unit – CB4-u Solar or Remote Mount Beacon/Strobe Kit
2. Drill and security bit for removing and inserting security screws on phone and access plate
3. 3/8 socket set to mount unit onto wall
4. Banding Tool for Pole Mount Kit

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 9 of 65
CB 4 Series
Administrator Guide
4 Spare Parts
CB 4-s
Part Part Number
Faceplate Screws 41544 (6pk)
Power 4 Connector 24V 40109
Analog Surge Suppressor 41471
IP Surge Suppressor 41421
CB 4-s with Dual Faceplates
Part Part Number
Faceplate Screws 41544 (6pk)
Power 4 Connector 24V 40109
Analog Surge Suppressor 41471
IP Surge Suppressor 41421
Blank Stainless Steel Plate Assembly 40066
CB 4-r
Part Part Number
LED Faceplate Light 40196
Faceplate Screws 41544 (6pk)
Analog Surge Suppressor 41471
IP Surge Suppressor 41421
Power 4 Connector 24V 40109
CB 4-u
Part Part Number
LED Faceplate Light 40196
Faceplate Screws 41544 (6pk)
Access Plate Screws 41500 x 2
Manifold R/B 5-way 40101
Analog Surge Suppressor 41471
IP Surge Suppressor 41421

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 10 of 65
CB 4 Series
Administrator Guide
CB 4 Series Additional Options
Part Part Number
Solar Battery – CB 4-u only 41436
Solar Panel – CB 4-u only 40156
GSM Assembly – CB 4-u only - Solar only 40028
GSM Assembly – CB 4-u only – NightCharge®only 40026
Service Plate - Lexan w/graphics (This Location Being Serviced) 40208
Pole Mount Kit 40027
Triad Transformer 40VA 120V (will not power accessories) – CB 4-u only 41246
Remote Mount Beacon/Strobe Kit 40525
PoE Power Splitter Kit Assembly 41574
IP5000 Speakerphone FP1 50101
IP5000 Speakerphone FP2 50102
Keypad IP5000 Speakerphone 50103
IA4100 Speakerphone FP1 50001
IA4100 Speakerphone FP2 50002
Keypad IA4100 Speakerphone 50003
Directory Plate Assembly – CB 4-s with Dual Faceplates only 40057
Color Camera Assembly – CB 4-s With Dual Faceplates only 41420
Wind Operated Generator – CB 4-u only 40355
Remote Mount Beacon Kit (Photocell) 40528
Multi-tap Power Brick – CB 4-u only 40104
Curb Mount Stand – (Excludes the CB 4-u) 41432

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 11 of 65
CB 4 Series
Administrator Guide
5 Power Requirements (2020)
(The following power requirements include the 4 Series and also ALL OTHER Code Blue units.)
Component Specs
Faceplates Voltage Max Current Max Watts Norm Current Norm Watts KWHrs
High Votage AC Components Voltage Current Watts KWHrs
IA4100 24V AC 0.40 9.60 0.22 5.28 0.13
Multi-Tap Power Supply 120V AC 1.75A/210VAC 210 5.04
12V DC 0.90 10.80 0.39 4.68 0.11
Din Rail Power Supply 120V AC 1.2A/115VAC 115 2.76
24V DC 0.90 21.60 0.39 9.36 0.22
Heater -AED 120V AC 1.6 192 4.61
IP5000 24V AC 0.10 2.40 0.07 1.68 0.04
DC - PS AED 120V AC 2.6 312 7.49
12V DC 0.19 2.28 0.15 1.8 0.04
PAS Amp 120V AC 3.83 459.6 11.03
24V DC 0.19 4.56 0.15 3.6 0.09
Centry®12V DC 0.50 6.00 0.38 4.56 0.11
Lights Voltage Max Current Max Watts Norm Current Norm Watts KWHrs
High Voltage Models Voltage Current Watts KWHrs
S-1000 LED Strobe 24V AC 2.80 67.20 0.22 5.28 0.13
CB 1 AED 120V AC 3.35 402 9.6
12V DC 0.26 3.12 0.24 2.88 0.07
CB 2 AED 120V AC 3.35 402 9.6
24V DC 0.26 6.24 0.24 5.76 0.14
CB 1 PAS 120V AC 3.83 460 11
A-700 Area Light 24 VAC 1.80 43.20 0.83 19.92 0.48
CB 5 PAS 120V AC 3.33 400 9.6
12V DC 2.68 32.16 0.38 4.56 0.11
CB 1-s w/ NightCharge®120V AC 2.5 300 2.4
24V DC 2.68 64.32 0.38 9.12 0.22
CB 4-u w/ NightCharge®120V AC 2.5 300 2.4
S-1050 LED Strobe w/ Photocell 24V AC 2.80 67.20 0.22 5.28 0.13
12V DC 2.68 32.16 0.38 4.56 0.11
24V DC 2.68 64.32 0.38 9.12 0.22
LED Light Bar 24V AC 0.04 0.96 0.04 0.96 0.02
12V DC 0.04 0.48 0.04 0.48 0.01
24V DC 0.04 0.96 0.04 0.96 0.02
WM-180 PAS with LED Strobe 24V AC 7.30 175.20 2.10 50.4 1.21
Common Configurations
Models With IA4100 Faceplate Voltage Current Watts KWHrs Models With IP5000 Faceplate Voltage Current Watts KWHrs
CB 1-e 24V AC 0.48 11.52 0.28 CB 1-e 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19 12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39 24V DC 0.43 10.32 0.25
CB 1-s 24V AC 1.31 31.44 0.75 CB 1-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30 12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60 24V DC 0.81 19.44 0.47
CB 5-s/5-p 24V AC 0.48 11.52 0.28 CB 5-s/5-p 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19 12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39 24V DC 0.43 10.32 0.25
CB 9-s 24V AC 0.26 6.24 0.15 CB 9-s 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12 12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25 24V DC 0.19 4.56 0.11
CB 2-e 24V AC 0.44 10.56 0.25 CB 2-e 24V AC 0.29 6.96 0.17
12V DC 0.63 7.56 0.18 12V DC 0.39 4.68 0.11
24V DC 0.63 15.12 0.36 24V DC 0.39 9.36 0.22
CB 2-a 24V AC 0.48 11.52 0.28 CB 2-a 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19 12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39 24V DC 0.43 10.32 0.25
CB 2-s 24V AC 1.31 31.44 0.75 CB 2-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30 12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60 24V DC 0.81 19.44 0.47
CB 2-e W/ PAS 24V AC 6.44 154.56 3.71 CB 2-e / PAS 24V AC 6.44 154.56 3.71
CB 4-s 24V AC 0.22 5.28 0.13 CB 4-s 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11 12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22 24V DC 0.15 3.6 0.09
CB 4-r 24V AC 0.26 6.24 0.15 CB 4-r 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12 12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25 24V DC 0.19 4.56 0.11
CB 4-u 24V AC 0.26 6.24 0.15 CB 4-u 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12 12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25 24V DC 0.19 4.56 0.11
Surface Mount/Flush Mount 24V AC 0.22 5.28 0.13 Surface Mount/Flush Mount 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11 12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22 24V DC 0.15 3.6 0.09
CB RT 24V AC 1.10 26.33 0.63 CB RT 24V AC 1.21 28.96 0.70
12V DC 0.81 9.75 0.23 12V DC 1.03 12.37 0.30
24V DC 1.61 38.57 0.93 24V DC 1.13 27.10 0.65
Component Specs
Faceplates Voltage Max Current Max Watts Norm Current Norm Watts KWHrs
High Votage AC Components Voltage Current Watts KWHrs
IA4100 24V AC 0.40 9.60 0.22 5.28 0.13
Multi-Tap Power Supply 120V AC 1.75A/210VAC 210 5.04
12V DC 0.90 10.80 0.39 4.68 0.11
Din Rail Power Supply 120V AC 1.2A/115VAC 115 2.76
24V DC 0.90 21.60 0.39 9.36 0.22
Heater -AED 120V AC 1.6 192 4.61
IP5000 24V AC 0.10 2.40 0.07 1.68 0.04
DC - PS AED 120V AC 2.6 312 7.49
12V DC 0.19 2.28 0.15 1.8 0.04
PAS Amp 120V AC 3.83 459.6 11.03
24V DC 0.19 4.56 0.15 3.6 0.09
Centry®12V DC 0.50 6.00 0.38 4.56 0.11
Lights Voltage Max Current Max Watts Norm Current Norm Watts KWHrs
High Voltage Models Voltage Current Watts KWHrs
S-1000 LED Strobe 24V AC 2.80 67.20 0.22 5.28 0.13
CB 1 AED 120V AC 3.35 402 9.6
12V DC 0.26 3.12 0.24 2.88 0.07
CB 2 AED 120V AC 3.35 402 9.6
24V DC 0.26 6.24 0.24 5.76 0.14
CB 1 PAS 120V AC 3.83 460 11
A-700 Area Light 24 VAC 1.80 43.20 0.83 19.92 0.48
CB 5 PAS 120V AC 3.33 400 9.6
12V DC 2.68 32.16 0.38 4.56 0.11
CB 1-s w/ NightCharge®120V AC 2.5 300 2.4
24V DC 2.68 64.32 0.38 9.12 0.22
CB 4-u w/ NightCharge®120V AC 2.5 300 2.4
S-1050 LED Strobe w/ Photocell 24V AC 2.80 67.20 0.22 5.28 0.13
12V DC 2.68 32.16 0.38 4.56 0.11
24V DC 2.68 64.32 0.38 9.12 0.22
LED Light Bar 24V AC 0.04 0.96 0.04 0.96 0.02
12V DC 0.04 0.48 0.04 0.48 0.01
24V DC 0.04 0.96 0.04 0.96 0.02
WM-180 PAS with LED Strobe 24V AC 7.30 175.20 2.10 50.4 1.21
Common Configurations
Models With IA4100 Faceplate Voltage Current Watts KWHrs Models With IP5000 Faceplate Voltage Current Watts KWHrs
CB 1-e 24V AC 0.48 11.52 0.28 CB 1-e 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19 12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39 24V DC 0.43 10.32 0.25
CB 1-s 24V AC 1.31 31.44 0.75 CB 1-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30 12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60 24V DC 0.81 19.44 0.47
CB 5-s/5-p 24V AC 0.48 11.52 0.28 CB 5-s/5-p 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19 12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39 24V DC 0.43 10.32 0.25
CB 9-s 24V AC 0.26 6.24 0.15 CB 9-s 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12 12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25 24V DC 0.19 4.56 0.11
CB 2-e 24V AC 0.44 10.56 0.25 CB 2-e 24V AC 0.29 6.96 0.17
12V DC 0.63 7.56 0.18 12V DC 0.39 4.68 0.11
24V DC 0.63 15.12 0.36 24V DC 0.39 9.36 0.22
CB 2-a 24V AC 0.48 11.52 0.28 CB 2-a 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19 12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39 24V DC 0.43 10.32 0.25
CB 2-s 24V AC 1.31 31.44 0.75 CB 2-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30 12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60 24V DC 0.81 19.44 0.47
CB 2-e W/ PAS 24V AC 6.44 154.56 3.71 CB 2-e / PAS 24V AC 6.44 154.56 3.71
CB 4-s 24V AC 0.22 5.28 0.13 CB 4-s 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11 12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22 24V DC 0.15 3.6 0.09
CB 4-r 24V AC 0.26 6.24 0.15 CB 4-r 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12 12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25 24V DC 0.19 4.56 0.11
CB 4-u 24V AC 0.26 6.24 0.15 CB 4-u 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12 12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25 24V DC 0.19 4.56 0.11
Surface Mount/Flush Mount 24V AC 0.22 5.28 0.13 Surface Mount/Flush Mount 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11 12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22 24V DC 0.15 3.6 0.09
CB RT 24V AC 1.10 26.33 0.63 CB RT 24V AC 1.21 28.96 0.70
12V DC 0.81 9.75 0.23 12V DC 1.03 12.37 0.30
24V DC 1.61 38.57 0.93 24V DC 1.13 27.10 0.65

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 12 of 65
CB 4 Series
Administrator Guide
Power Requirements continued
Component Specs
Faceplates Voltage Max Current Max Watts Norm Current Norm Watts KWHrs High Votage AC Components Voltage Current Watts KWHrs
IA4100 24V AC 0.40 9.60 0.22 5.28 0.13 Multi-Tap Power Supply 120V AC 1.75A/210VAC 210 5.04
12V DC 0.90 10.80 0.39 4.68 0.11 Din Rail Power Supply 120V AC 1.2A/115VAC 115 2.76
24V DC 0.90 21.60 0.39 9.36 0.22 Heater -AED 120V AC 1.6 192 4.61
IP5000 24V AC 0.10 2.40 0.07 1.68 0.04 DC - PS AED 120V AC 2.6 312 7.49
12V DC 0.19 2.28 0.15 1.8 0.04 PAS Amp 120V AC 3.83 459.6 11.03
24V DC 0.19 4.56 0.15 3.6 0.09
Centry®12V DC 0.50 6.00 0.38 4.56 0.11
Lights Voltage Max Current Max Watts Norm Current Norm Watts KWHrs High Voltage Models Voltage Current Watts KWHrs
S-1000 LED Strobe 24V AC 2.80 67.20 0.22 5.28 0.13 CB 1 AED 120V AC 3.35 402 9.6
12V DC 0.26 3.12 0.24 2.88 0.07 CB 2 AED 120V AC 3.35 402 9.6
24V DC 0.26 6.24 0.24 5.76 0.14 CB 1 PAS 120V AC 3.83 460 11
A-700 Area Light 24 VAC 1.80 43.20 0.83 19.92 0.48 CB 5 PAS 120V AC 3.33 400 9.6
12V DC 2.68 32.16 0.38 4.56 0.11
CB 1-s w/ NightCharge®120V AC 2.5 300 2.4
24V DC 2.68 64.32 0.38 9.12 0.22
CB 4-u w/ NightCharge®120V AC 2.5 300 2.4
S-1050 LED Strobe w/ Photocell 24V AC 2.80 67.20 0.22 5.28 0.13
12V DC 2.68 32.16 0.38 4.56 0.11
24V DC 2.68 64.32 0.38 9.12 0.22
LED Light Bar 24V AC 0.04 0.96 0.04 0.96 0.02
12V DC 0.04 0.48 0.04 0.48 0.01
24V DC 0.04 0.96 0.04 0.96 0.02
WM-180 PAS with LED Strobe 24V AC 7.30 175.20 2.10 50.4 1.21
Common Configurations
Models With IA4100 Faceplate Voltage Current Watts KWHrs
Models With IP5000 Faceplate Voltage Current Watts KWHrs
CB 1-e 24V AC 0.48 11.52 0.28
CB 1-e 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19
12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39
24V DC 0.43 10.32 0.25
CB 1-s 24V AC 1.31 31.44 0.75
CB 1-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30
12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60
24V DC 0.81 19.44 0.47
CB 5-s/5-p 24V AC 0.48 11.52 0.28
CB 5-s/5-p 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19
12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39
24V DC 0.43 10.32 0.25
CB 9-s 24V AC 0.26 6.24 0.15
CB 9-s 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12
12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25
24V DC 0.19 4.56 0.11
CB 2-e 24V AC 0.44 10.56 0.25
CB 2-e 24V AC 0.29 6.96 0.17
12V DC 0.63 7.56 0.18
12V DC 0.39 4.68 0.11
24V DC 0.63 15.12 0.36
24V DC 0.39 9.36 0.22
CB 2-a 24V AC 0.48 11.52 0.28
CB 2-a 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19
12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39
24V DC 0.43 10.32 0.25
CB 2-s 24V AC 1.31 31.44 0.75
CB 2-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30
12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60
24V DC 0.81 19.44 0.47
CB 2-e W/ PAS 24V AC 6.44 154.56 3.71
CB 2-e / PAS 24V AC 6.44 154.56 3.71
CB 4-s 24V AC 0.22 5.28 0.13
CB 4-s 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11
12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22
24V DC 0.15 3.6 0.09
CB 4-r 24V AC 0.26 6.24 0.15
CB 4-r 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12
12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25
24V DC 0.19 4.56 0.11
CB 4-u 24V AC 0.26 6.24 0.15
CB 4-u 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12
12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25
24V DC 0.19 4.56 0.11
Surface Mount/Flush Mount 24V AC 0.22 5.28 0.13
Surface Mount/Flush Mount 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11
12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22
24V DC 0.15 3.6 0.09
CB RT 24V AC 1.10 26.33 0.63
CB RT 24V AC 1.21 28.96 0.70
12V DC 0.81 9.75 0.23
12V DC 1.03 12.37 0.30
24V DC 1.61 38.57 0.93
24V DC 1.13 27.10 0.65

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 13 of 65
CB 4 Series
Administrator Guide
Power Requirements continued
Component Specs
Faceplates Voltage Max Current Max Watts Norm Current Norm Watts KWHrs High Votage AC Components Voltage Current Watts KWHrs
IA4100 24V AC 0.40 9.60 0.22 5.28 0.13 Multi-Tap Power Supply 120V AC 1.75A/210VAC 210 5.04
12V DC 0.90 10.80 0.39 4.68 0.11 Din Rail Power Supply 120V AC 1.2A/115VAC 115 2.76
24V DC 0.90 21.60 0.39 9.36 0.22 Heater -AED 120V AC 1.6 192 4.61
IP5000 24V AC 0.10 2.40 0.07 1.68 0.04 DC - PS AED 120V AC 2.6 312 7.49
12V DC 0.19 2.28 0.15 1.8 0.04 PAS Amp 120V AC 3.83 459.6 11.03
24V DC 0.19 4.56 0.15 3.6 0.09
Centry®12V DC 0.50 6.00 0.38 4.56 0.11
Lights Voltage Max Current Max Watts Norm Current Norm Watts KWHrs High Voltage Models Voltage Current Watts KWHrs
S-1000 LED Strobe 24V AC 2.80 67.20 0.22 5.28 0.13 CB 1 AED 120V AC 3.35 402 9.6
12V DC 0.26 3.12 0.24 2.88 0.07 CB 2 AED 120V AC 3.35 402 9.6
24V DC 0.26 6.24 0.24 5.76 0.14 CB 1 PAS 120V AC 3.83 460 11
A-700 Area Light 24 VAC 1.80 43.20 0.83 19.92 0.48 CB 5 PAS 120V AC 3.33 400 9.6
12V DC 2.68 32.16 0.38 4.56 0.11
CB 1-s w/ NightCharge®120V AC 2.5 300 2.4
24V DC 2.68 64.32 0.38 9.12 0.22
CB 4-u w/ NightCharge®120V AC 2.5 300 2.4
S-1050 LED Strobe w/ Photocell 24V AC 2.80 67.20 0.22 5.28 0.13
12V DC 2.68 32.16 0.38 4.56 0.11
24V DC 2.68 64.32 0.38 9.12 0.22
LED Light Bar 24V AC 0.04 0.96 0.04 0.96 0.02
12V DC 0.04 0.48 0.04 0.48 0.01
24V DC 0.04 0.96 0.04 0.96 0.02
WM-180 PAS with LED Strobe 24V AC 7.30 175.20 2.10 50.4 1.21
Common Configurations
Models With IA4100 Faceplate Voltage Current Watts KWHrs
Models With IP5000 Faceplate Voltage Current Watts KWHrs
CB 1-e 24V AC 0.48 11.52 0.28
CB 1-e 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19
12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39
24V DC 0.43 10.32 0.25
CB 1-s 24V AC 1.31 31.44 0.75
CB 1-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30
12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60
24V DC 0.81 19.44 0.47
CB 5-s/5-p 24V AC 0.48 11.52 0.28
CB 5-s/5-p 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19
12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39
24V DC 0.43 10.32 0.25
CB 9-s 24V AC 0.26 6.24 0.15
CB 9-s 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12
12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25
24V DC 0.19 4.56 0.11
CB 2-e 24V AC 0.44 10.56 0.25
CB 2-e 24V AC 0.29 6.96 0.17
12V DC 0.63 7.56 0.18
12V DC 0.39 4.68 0.11
24V DC 0.63 15.12 0.36
24V DC 0.39 9.36 0.22
CB 2-a 24V AC 0.48 11.52 0.28
CB 2-a 24V AC 0.33 7.92 0.19
12V DC 0.67 8.04 0.19
12V DC 0.43 5.16 0.12
24V DC 0.67 16.08 0.39
24V DC 0.43 10.32 0.25
CB 2-s 24V AC 1.31 31.44 0.75
CB 2-s 24V AC 1.16 27.84 0.67
12V DC 1.05 12.60 0.30
12V DC 0.81 9.72 0.23
24V DC 1.05 25.20 0.60
24V DC 0.81 19.44 0.47
CB 2-e W/ PAS 24V AC 6.44 154.56 3.71
CB 2-e / PAS 24V AC 6.44 154.56 3.71
CB 4-s 24V AC 0.22 5.28 0.13
CB 4-s 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11
12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22
24V DC 0.15 3.6 0.09
CB 4-r 24V AC 0.26 6.24 0.15
CB 4-r 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12
12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25
24V DC 0.19 4.56 0.11
CB 4-u 24V AC 0.26 6.24 0.15
CB 4-u 24V AC 0.11 2.64 0.06
12V DC 0.43 5.16 0.12
12V DC 0.19 2.28 0.05
24V DC 0.43 10.32 0.25
24V DC 0.19 4.56 0.11
Surface Mount/Flush Mount 24V AC 0.22 5.28 0.13
Surface Mount/Flush Mount 24V AC 0.07 1.68 0.04
12V DC 0.39 4.68 0.11
12V DC 0.15 1.8 0.04
24V DC 0.39 9.36 0.22
24V DC 0.15 3.6 0.09
CB RT 24V AC 1.10 26.33 0.63
CB RT 24V AC 1.21 28.96 0.70
12V DC 0.81 9.75 0.23
12V DC 1.03 12.37 0.30
24V DC 1.61 38.57 0.93
24V DC 1.13 27.10 0.65

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 14 of 65
CB 4 Series
Administrator Guide
6 Legacy Power Requirements
(The following power requirements include the 4 Series and also ALL OTHER Code Blue units.)

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 15 of 65
CB 4 Series
Administrator Guide

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 16 of 65
CB 4 Series
Administrator Guide
7 Software Configuration
Blue Alert® MNS Software
Blue Alert MNS (Mass Notication Software) lls a need in the marketplace for an incident response
solution that is both comprehensive and cost-effective, while also providing an efcient way to detect
and respond. The advanced mass notication system allows responders to deliver multi-layered
emergency notications via a wide range of platforms, including email, text message (SMS), emer-
gency phones, public address speakers, social media, desktop alerts and more, quickly informing
and directing people in emergency situations.
Blue Alert® EMS
Blue Alert EMS is an advanced software solution that handles all incoming events effectively by re-
motely controlling emergency communication devices with an easy-to-use Graphical User Interface
(GUI). You also will have the ability to open gates and AED access doors, turn LED beacon/strobes
on or off, transfer calls to Public Address Systems to make area wide announcements and incor-
porate other ancillary devices and applications while the system securely archives data for future
reference.
ToolVox®
A sophisticated emergency management platform for your blue light phone network, ToolVox offers
unique real-time monitoring and provisioning options for emergency phones and public address
speakers, effectively acting as a hub for connecting Help Points®and other Code Blue devices. Us-
ing our proprietary incident response software, Blue Alert®MNS and EMS, you can send alerts via
outdoor platforms, such as blue light phones and public address speakers. It also provides connec-
tions to PBX, public telephone (PSTN) and Internet (ISP) networks, in addition to third party security
platforms.

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 17 of 65
CB 4 Series
Administrator Guide
8 CB 4-s Low Voltage Exploded View
DISCLAIMER: Product design and component use subject to change without notice. Product shown reasonably represents current offering and
is intended to assist in component identication. Reference the model and serial number from the unit ID tag and contact manufacturer to conrm
replacement part version and availability.
2
4 31
5
ITEM # DESCRIPTION QTY
1 Wall Mount Painted Assy 1
2 Standard / Custom Graphic 2
3 Grounding Lug 1
4 10-24 Nylock Nut 1
5 Power 4 Connector 24V 1

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 18 of 65
CB 4 Series
Administrator Guide
9 CB 4-r Low Voltage Exploded View
DISCLAIMER: Product design and component use subject to change without notice. Product shown reasonably represents current offering and
is intended to assist in component identication. Reference the model and serial number from the unit ID tag and contact manufacturer to conrm
replacement part version and availability.
1
5
4
2
6
3
2
ITEM # DESCRIPTION QTY
1 Hooded Wall Mount Painted Assy 1
2 Standard / Custom Graphic 3
3Faceplate Light Assy 1
4 Grounding Lug 1
5 10-24 Nylock Nut 1
6 Power 4 Connector 24V 1

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 19 of 65
CB 4 Series
Administrator Guide
DISCLAIMER: Product design and component use subject to change without notice. Product shown reasonably represents current offering and
is intended to assist in component identication. Reference the model and serial number from the unit ID tag and contact manufacturer to conrm
replacement part version and availability.
4
3
1
5
2
10 CB 4-s with Dual Faceplates Low Voltage Exploded View
ITEM # DESCRIPTION QTY
1 Hooded Wall Mount Dual Painted Assy 1
2 Standard / Custom Graphic 2
3 Grounding Lug 1
4 10-24 Nylock Nut 1
5 Power 4 Connector 24V 1

Code Blue •259 Hedcor Street •Holland, MI 49423 USA •800.205.7186 •www.codeblue.com GU-160-Tpage 20 of 65
CB 4 Series
Administrator Guide
11 CB 4-u Low Voltage Exploded View
DISCLAIMER: Product design and component use subject to change without notice. Product shown reasonably represents current offering and
is intended to assist in component identi cation. Reference the model and serial number from the unit ID tag and contact manufacturer to con rm
replacement part version and availability.
BALL # PART # DESCRIPTION
1 CALL Standard / Custom Graphic
2 41471 Analog Surge Suppressor
2 41421 IP Surge Suppressor
3 40102 Wall Anchor Kit
4 41548 LED Faceplate Light
5 41700 24V Fuse Block
6 41544 Faceplate Security Screw 10x24 (6 pk)
7 50001 Single Button IA4100 Analog Phone – PUSH FOR HELP
7 50002 Double Button IA4100 Analog Phone – PUSH FOR HELP
7 50003 Keypad IA4100 Analog Phone – PUSH FOR HELP
7 50004 Single Button IA4100 Analog Phone – EMERGENCY
7 50005 Double Button IA4100 Analog Phone – EMERGENCY
7 50006 Keypad IA4100 Analog Phone – EMERGENCY
BALL # PART # DESCRIPTION
7 50101 Single Button IP5000 VoIP Phone – PUSH FOR HELP
7 50102 Double Button IP5000 VoIP Phone – PUSH FOR HELP
7 50103 Keypad IP5000 VoIP Phone – PUSH FOR HELP
7 50104 Single Button IP5000 VoIP Phone – EMERGENCY
7 50105 Double Button IP5000 VoIP Phone – EMERGENCY
7 50106 Keypad IP5000 VoIP Phone – EMERGENCY
8 41500 Button Head Security Screws (3 pk)
9 40357 Bezel Assembly IA4100 Analog Phone – PUSH FOR HELP
9 40407 Bezel Assembly IA4100 Analog Phone – EMERGENCY
9 40313 Bezel Assembly IP5000 VoIP Phone – PUSH FOR HELP
9 40405 Bezel Assembly IP5000 VoIP Phone – EMERGENCY
1
2
3
1
4
6
9
7
8
3
5
Other manuals for CB 4 Series
1
This manual suits for next models
4
Table of contents
Other Code Blue Enclosure manuals
Popular Enclosure manuals by other brands

Leviton
Leviton 49605-14P quick start guide

TSI Instruments
TSI Instruments DUSTTRAK 854030 Operation and maintenance manual

Hubbell
Hubbell Killark USF Series INSTALLATION, OPERATION & MAINTENANCE DATA SHEET

Peavey
Peavey PVs 18 Sub operating manual

nfortec
nfortec AZIR instruction manual

Siemens
Siemens EB-32 Installation and Power Limited Wiring Instructions