Page 2 of 28
INSTRUCTION MANUAL
CLCI-100 BULK CURRENT INJECTION PROBE
with FCLC-100 CALIBRATION FIXTURE
19121 El Toro Rd ●Silverado, California 92676 ●(949) 459-9600 ●com-power.com
REV051917
Table of Contents
1.0 Introduction ........................................................................................................... 4
2.0 Products Available from Com-Power ................................................................. 5
3.0 Product Information .............................................................................................. 6
3.1 Incoming Inspection....................................................................................................... 6
3.2 Package Inventory ......................................................................................................... 6
3.3 Product Safety Information ........................................................................................... 7
3.3.1 Product Hazard Symbols Definitions........................................................................................... 7
3.3.2 Product Warning/Caution Statements...................................................................................... 7
3.3.3 General Safety Instructions.......................................................................................................... 7
3.4 Product Features ............................................................................................................. 8
3.4.1 Description of CLCI-100 Bulk Current Injection Probe Features ............................................ 8
3.4.2 Description of FCLC-100 Calibration Fixture Features............................................................. 9
3.5 Product Specifications ................................................................................................. 10
3.5.1 Specifications for CLCI-100 Bulk Current Injection Probe..................................................... 10
3.5.2 Specifications for FCLC-100 Calibration Fixture ..................................................................... 10
3.6 Product Dimensional Diagrams .................................................................................. 11
3.6.1 Dimensions of CLCI-100 Bulk Current Injection Probe........................................................... 11
3.6.2 Dimensions of FCLC-100 Calibration Fixture ........................................................................... 12
4.0 Using the CLCI-100 Probe with the FCLC-100 Fixture....................................... 13
4.1 Installation of CLCI-100 Probe into FCLC-100 Fixture ............................................. 13
4.2 Insertion Loss/Coupling Factor Measurement.......................................................... 14
4.3 Transfer Impedance Factors ....................................................................................... 15
4.4 Conducted Immunity Test Level Calibration (IEC 61000-4-6)................................ 16
4.4.1 Test Generator Equipment (Method A vs Method B) ........................................................... 16
4.4.2 Calibration-related Calculations .............................................................................................. 18
4.4.2.1 Test Level Calculations ............................................................................................................... 18
4.4.2.2 Test Level Offset Calculations ................................................................................................... 19
4.4.2.3 Test Frequency Calculations .....................................................................................................19
4.4.3 Equipment Setup ......................................................................................................................... 20
4.4.4 Level Setting Process................................................................................................................... 22
4.4.5 Amplifier Saturation Check........................................................................................................ 23
4.4.6 Running the Test .......................................................................................................................... 24
4.5 Conducted Susceptibility Test Level Calibration (50ΩSystem)............................. 26
5.0 Warranty............................................................................................................... 27
6.0 Typical CLCI-100 Calibration Data.................................................................... 28