INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
INSTRUCTIONMANUAL
For
LINEIMPEDANCESTABILIZATIONNETWORK
ModelLI‐215A
9kHzto30MHz

Page2of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
TableofContents
1.0Introduction..............................................................................................................3
2.0ProductDescription......................................................................................................4
Overview.....................................................................................................................................4
Standarditemsincluded:...........................................................................................................4
3.0ProductSpecifications..............................................................................................5
3.1OtherequipmentavailablefromCom‐Power............................................................5
4.0ImportantSafetyPrecautions..................................................................................6
5.0Warranty...................................................................................................................7
5.1Maintenance..................................................................................................................7
6.0Frontandrearpanelmarking.....................................................................................8
6.1Powerinputport............................................................................................................................8
6.2EUTpowerport...............................................................................................................................8
6.3EMImeasurementPort..................................................................................................................8
6.4Testleadselectionswitch(Line/LIorNeutral/L2).....................................................................8
6.5Groundingbolt(GND)....................................................................................................................8
7.0LISNTheory...............................................................................................................9
7.1Overview.......................................................................................................................9
Figure1–ExampleofanequivalentLISNcircuit..................................................................................9
8.0TypicalPerformanceData.......................................................................................10
Figure2‐Impedancec0mparedtoCISPR16‐1‐2andANSI63.4requirements.....................................10
Figure3‐PhasecomparedtoCISPR16‐1‐2andANSI63.4requirements............................................10

Page3of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
1.0Introduction
Thismanualincludesproductspecifications,safetyprecautions,productmaintenanceand
warrantyinformation.Italsoincludessomebasicguidanceonproperlyconfiguring
calibration,testsetup,runningtestlevelcalibrationsandperformingconductedemissions
testing.
InformationcontainedinthismanualisthepropertyofCom‐PowerCorporation.Itisissued
withtheunderstandingthatnoneofthematerialmaybereproducedorcopiedwithout
permissionfromCom‐Power.

Page4of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
2.0ProductDescription
Overview
TheLI‐215ALineImpedanceStabilizationNetworkwasspecificallydesignedforproviding
standardizedlineimpedanceduringElectromagneticCompatibility(EMC)testinginaccordance
withFCC,CISPRandCErequirements.
Inaddition,itminimizesthenoisegeneratedbyequipmentotherthantheEUTtobeincludedin
themeasurement.
Standarditemsincluded:
Equipment,accessories,anddocumentssuppliedwiththemodelLI‐215ALISNareasfollows:
oUser'sguide.
oACPowercord.
oCalibrationdataandCertificatetraceabletoNIST.
Optionalitems
oISO‐17025calibrationdataandcertificate.
oExternaltransientlimitermodelLIT‐930

Page5of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
3.0ProductSpecifications
Model:LI‐215A
Electrical
FrequencyRange:9kHzto30MHz
CompliantStandards:CISPR16‐1‐2Edition1.2:2006‐08,ANSIC63.4:2003&2009
Numberoflines:Twolines
Maxcurrentrating:15AmpAC,10AmpDC
MaxVoltageRating:270VAC,50/60Hz(LinetoGround)/380VDC
Inductortype:250µHand50µH
Internallinetermination:Yes,50Ω
EUTPowerConnector:NEMA5‐15Rreceptacle
Powerinputconnector:IEC60320Inlet
RFmeasurementconnector:50Ω,Ntype(female)
OperatingTemperature:5°Cto40°C/40°Fto104°F
M
echanical
Dimensions(LxWxH):17.5x13x7.5inches/44x33x19cm
Weight:28lb./12.5kg
Thisequipmentisdesignedforindooruseonly.
3.1OtherequipmentavailablefromCom‐Power
•SPA‐3000SpectrumAnalyzer
•PS‐400NearFieldProbekit
•PS‐500NearFieldProbekit
•LIN‐115A,LISN150kHz–30MHz,15A
•LI‐125A,LISN150kHz–30MHz,25A
•LI‐150A,LISN150kHz–30MHz,50A
•SpecialorderLISNswithhighervoltageand/orcurrent
•LIT‐930TransientLimiter
•LIT‐153TransientLimiter

Page6of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
4.0 ImportantSafetyPrecautions
TheLISNmustbesecurelyfastenedtotheearthgroundbeforemakinganyconnectionsto
externalpower.PropergroundingoftheLISNnotonlyensurescorrectconductedemissions
measurementsandalsopreventspotentialhighleakagecurrentfrompresentingahazardtest
personnel.TohelpestablishpropergroundingthebottomsurfaceoftheLISNisunpainted.In
addition,thebottomplatehasholesforsecurelyboltingtheLISNtothegroundplane.
OnlyconnectEUTswithpowerplugwithaprotectiveearthcontactshouldbeinsertedintoLISN
powerinputport.Theprotectiveactionmustnotbenegatedbytheuseofacheaterplugoran
extensioncordwithoutaprotectiveconductor.
Maintenance
Therearenouserserviceablepartsinsidetheunit.UsermodificationstotheLISNswillvoid
warrantyandmayalsoinvalidatethecalibration.SendtheLISNtoauthorizedCom‐Power
servicecenterifneedsrepair.Pleasevisitourwebsiteatwww.com‐power.comtorequesta
returnmerchandiseauthorizationnumber(RMA)beforeyousendtheunitinforservice.
Environmentalconditions
Thisequipmentisdesignedforindoorusetobesafeunderthefollowingenvironmental
Conditions:
•Temperature:5°Cto40°C
•Maximumrelativehumidity:80%

Page7of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
5.0 Warranty
Com‐PowerwarrantstoitsCustomersthattheproductsitmanufactureswillbefreefrom
defectsinmaterialsandworkmanshipforaperiodof3years.Thiswarrantyshallnotapplyto:
•Transportdamagesduringshipmentfromyourplant.
•Damagesduetopoorpackaging.
•Productsoperatedoutsidetheirspecifications.
•ProductsImproperlymaintainedormodified.
•Consumableitemssuchasfuses,powercords,cables,etc.
•Normalwear
•Calibration
•ProductsshippedoutsidetheUnitedStateswithoutthepriorknowlegeofCom‐
Power.
Inaddition,Com‐Powershallnotbeobligedtoprovideserviceunderthiswarrantytorepair
damageresultingfromattemptstoinstall,repair,serviceormodifytheinstrumentby
personnelotherthanCom‐Powerservicerepresentatives.
UndernocircumstancesdoesCom‐Powerrecognizeorassumeliabilityforanyloss,damage
orexpensearising,eitherdirectlyorindirectly,fromtheuseorhandlingofthisproduct,or
anyinabilitytousethisproductseperatelyorincombinationwithanyotherequipment.
Whenrequestingwarrantyservices,itisrecommendedthattheoriginalpackagingmaterial
beusedforshipping.Damageduetoimproperpackagingwillvoidwarranty.
Inthecaseofrepairorcomplaint,alabelshouldbeattachedtothehousingofthe
instrumentwhichdescribesbrieflythefaultsobserved.Pleaseincludethename,telephone
numberandemailaddressofthecontactperson.Pleasevisitourwebsitewww.com‐
power.comandobtainanRMAnumberbyselectingserviceandcompletingtheonlineform.
5.1Maintenance
Thisproductcontainnouserserviceablepartsinside.Iftheunitdoesnotoperateorneeds
calibration,pleasecontactCom‐PowerCorporation.Donotinstrumentcover.Any
modificationsorrepairsperformedontheunitbysomeoneotherthananauthorizedfactory
trainedtechnicianwillvoidwarranty.
Theexteriorsurfacemaybecleanedwithmilddetergentandthenbewipedwithadry,clean,
lint‐freecloth.Usecaretoavoidliquidsorotherforeignobjectsenteringthechassis.

Page8of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
6.0Frontandrearpanelmarking
6.1Powerinputport
TheModelLI‐215AhasastandardIECinletlocatedonthebackpanelforconnectiontoexternal
DCorACpowersource.Itcanhandle270VACor380VDCinput.Seespecificationtableonpage
3ofthismanual.
6.2EUTpowerport
TheLI‐215AusesaNEMA5‐15R(standardUSwallsocket)sockettopowertheequipmentunder
test.
6.3EMImeasurementPort
The50ΩType'N'connectorlocatedtotherightoftheEUTPowerPortisforconnectingthe
SpectrumanalyzerorEMIreceiverformakingconductednoisemeasurements.
6.4Testleadselectionswitch(Line/LIorNeutral/L2)
Thisswitchallowsmeasurementofnoisefromeachline.Thelinethatisnotbeingmeasuredis
automaticallyterminatedinternallybya50Ωterminator.However,thepowertoEUTis
uninterrupted.
6.5Groundingbolt(GND)
Theboltmarked'GND'onbackpaneloftheLISNisusedforextragroundingwithabraidor
shortwire.ThisisinadditiontomountingtheLISNontheRFgroundplaneusingconductive
bottomsurface.

Page9of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
7.0 LISNTheory
7.1Overview
LineImpedanceStabilizationNetworksusedsupplystandardizedlineimpedancetotheEUT
duringconductedemissionstestingwhichisindependentoftheexternalpowerlineimpedance.
ThestandardizedimpedanceenablesconsistentreadingsforRFnoisemeasurementsonthe
powerline.ThemodelLI‐215AconsistsoftwoseparateLISNnetworkshousedinasingle
enclosurefortestingEUTswithsinglephasepowerrequirementsdownto9kHz.
Inadditiontoprovidingstandardizedimpedance,theLISNalsoactsasalowpassfilterforthe
powertoequipmentundertest.TheLISNblocksRFnoisefromthepowerlinefromreachingthe
equipmentundertest,however,thepowertotheequipmentpassesthroughtheLISNwith
minimaleffect.ThisfiltercomprisesoftwostagelowpassLCfilters.Therefore,therearetwo
capacitorsandtwoinductorsforthefilters.ThetwoinductorsusedintheLI‐215Aareaircore
typetoeliminatethepossibilityofsaturationandtoprovidestability.
TheLISNalsoprovidesalowimpedancepathfortheRFnoisefromtheEUTtothemeasuring
equipment,therebyfacilitatingthemeasurementoftheRFnoise.Theinsertionlossofthe
measurednoisemaybesignificantatlowfrequency.Therefore,atfrequenciesbelow400kHz,
theinsertionlosscorrectionfactormustbecompensatedforhighestaccuracynoise
measurement.
TheschematicoftheLISNaswellaslineimpedanceisspecifiedintheANSIC63.4asCISPR‐16‐1‐
2standards.AtypicalcircuitdiagramofanLISNisgiveninFigure1below.
Figure1–ExampleofanequivalentLISNcircuit

Page10of10
INSTRUCTIONMANUALFORLI‐215A
LINEIMPEDANCESTABILIZATIONNETWORK(LISN)
114OLINDADRIVE●BREA,CALIFORNIA92823●(714)528‐8800●fax(714)528‐1992●com‐power.com
REV043013
8.0TypicalPerformanceData
Figure2‐Impedancec0mparedtoCISPR16‐1‐2andANSI63.4requirements.
Figure3‐PhasecomparedtoCISPR16‐1‐2requirements.
0
10
20
30
40
50
60
70
0.01 0.1 1 10 100
Impedance(Ω)
Frequency(MHz)
CISPR16‐1‐2 Limit
ANSI63.42009Limit
‐20
0
20
40
60
80
0.001 0.01 0.1 1 10 100
PhaseAngle(degrees)
Frequency(MHz)
Table of contents