comfortel AquaGlo 7762 User manual

comfortel.com.au
#7762 AQUAGLO
AquaGlo
owners manual

IMPORTANT PLEASE READ THESE SAFETY INSTRUCTIONS
GENERAL SAFETY & OPERATION
1. Read carefully and keep these instructions in a safe place.
2. Use this product only for its intended function and do not use attachments not recommended by the manufacturer.
3. Do not use outdoors.
4. Do not store or use the unit near water or at extreme temperatures, either cold or hot.
5. Do not expose unit to corosive air or dust.
6. Do not expose the unit to flammables or any closed space where oxygen is used.
7. Use only approved solutions and cleaners for servicing unit.
8. Do not open, alter, renovate or disassemble the unit in any way except when instructed by Customer Service.
9. Stop the unit immediately if there is any error in operations.
10. Only trained, authorized person(s) should operate the unit.
11. To avoid excessive heat build up, unit should be powered down for 10-15 minutes after each hour of continuous
use
12. Exposure to electrical surge or shock can damage the internal components of the unit. Ensure the unit's electrical
cord is in good condition and is plugged into a surge protected outlet. Unplug the power cable if unit is not in use
for a long period of time
13. Unit should be checked regularly and any damaged, broken part of the unit should be marked and the whole unit
should be returned to distributor for service
BIOLOGICAL HAZARDS & CLIENT SAFETY
1. Residues such as blood, sebum, and skin debris in the suction bottle should be completely removed and cleaned
after use.
2. All used tips must be immediately disposed of after treatment OR the correct sterilisation procedure (outlined
in cleaning procedures) must be followed before the tips may be re-used. Failure to comply with this may result in
transmission of infection
3. Extremely high suction pressure may cause damage to the client's skin. Select proper suction pressure according to
skin conditions.
CONTRAINDICATIONS & PRECAUTIONS
As with any beauty treatment, there are some individuals who may not be suited to receiving treatment with this
equipment. We recommend that you DO NOT treat the following:
• Undiagnosed skin lesions
• Areas of damaged skin
• Active rosacea
• Large areas of inflammatory acne
• Clients taking RoAccutane
• Clients with a cold sore
• Eyelid areas
• Areas of eczema/dermatitis
• Very vascular (red) skins with fragile capillaries
• Clients with very thin or loose skin
• Clients taking medicines that cause thinning of
skin (oral cortisone etc.)
• Cold sore suerers should be aware that treating over the prone area may stimulate an outbreak of a cold sore
(avoid area if possible)
• Clients who take blood thinning medications may be more prone to bruising or capillary damage. Treat with
caution and use low vacuum settings.
CONTRAINDICATIONS
PRECAUTIONS

`
AQUAGLO UNIT
1. Main housing
2. Solution 3 bottle
3. ON/OFF switch for solution 3
4. Solution 1 bottle
5. ON/OFF switch for solution 1
6. Storage tray
7. Hand piece
8. Suction 'IN' tube
9. Suction 'OUT' tube
10. ON/OFF switch
11. Suction bottle
12. Power cord
13. Vacuum control (right panel)
14. Flow control (left panel)
COMPONENTS
1
2
3
4
5
6
8
11
12
9
10
13
14
1. Main unit x1
2. Tips - large (disposable) x10
3. Tips - small (disposable) x10
4. Blue cleaning tips (disposable) x2
5. White cleaning bottle x1
6. Suction bottle x1
7. Solution 1 bottle x4
8. Solution 3 bottle x2
9. Owners manual x1
10. Power cable x1
IN THE BOX
7

PREPARATION
1. Check the mains power supply matches the specifications
(220V)
2. Check if switches, tubes and accessories are properly
connected and if the unit works normally.
3. Refill the serum bottles if necessary
4. Check the condition and contents of suction bottles and
tubes before use. Contents of the suction bottle should
be cleaned out after every use. Wash with warm water
and mild detergent, rinse clean before re-attaching to
system.
5. Connect the suction bottle as shown. Make sure the
bottle is properly installed on the unit and suction bottle
cover is sealed correctly. Make sure the bottle has
sucient space to collect waste.
6. Ensure the stainless steel springs are firmly connected to
the two large tubes.
Note:
Ensure only authorized, qualified persons operate the unit.
Read owners manual thoroughly before first use.
1. Remove clear treatment tip from hand piece and fit the blue cleaning tip in its place.
2. Remove Solution 1 bottle and replace with white cleaning bottle filled with a 10:1 distilled water and white vinegar
solution. Place suction tube and cap onto white cleaning bottle
3. Turn the flow dial to maximum.
4. Press the Solution 1 on/o button and run cleaning tip for 2 minutes.
5. after 2 minutes, repeat the same procedure with the solution 3 side of the system.
6. Turn o machine, empty cleaning bottle and rinse thoroughly.
7. Repeat steps 2 - 6 with distilled water only (no vinegar) in the cleaning bottles to flush the system of cleaning fluid.
1. Install power cord into base and plug into power source and turn on main power switch
2. Press the on/o button for Solution 1 (green) or Solution 3 (orange) to start
3. Set vacuum setting to 3, and flow rate setting just above minimum to begin, then adjust according to client skin
type and comfort, and treatment objective.
4. Put hand piece on skin and apply treatment
5. After finishing each session, ensure equipment is cleaned as per recommended procedure
OPERATION
CLEANING

STERILIZATION OF TREATMENT TIPS
All used tips must be immediately disposed of after treatment OR the correct
sterilization procedure (outlided below) must be followed before the tips may be re-
used. Washing with soap and water only is NOT an adequate method of cleaning
the tips, and may result in the transmission of infection.
STERILIZATION PROCEDURE:
1. Wearing gloves, remove the used tips from the handpiece immediately after
treatment
2. Using warm running water, mild alkaline detergent and a small bristle brush (a
toothbrush is ideal), scrub any product residue and skin debris out of the tips
and rinse thoroughly. Ensure all surfaces are scrubbed - inside and out.
3. Dry with lint-free cloth or paper towel
4. Prepare an industry-approved chemical sterilizing agent according to
manufacturer instructions. Carefully follow out correct dilution instructions
5. soak the cleaned tips in the solution for the recommended amount of time
(follow manufacturer instructions, as this will vary depending on chemical used
and dilution recommended)
6. remove the tips from the solution, allow to air dry on paper towel
7. store the dry tips in a covered container until next use.
SPECIFICATIONS
Size: 350 (W) x 200 (D) x 323 (H)
Weight: 13kg
Vacuum: 550mmHg
Voltage: AC220V
Frequency: 50/60 Hz
Power: 100W
Ranges of vacuum suction adjustment: 0 - 10
Ranges of solution flow rate adjustment: LOW to HIGH
Noise level: Less than 60dB
Operation mode: Continuous
Operation and storage temperatures:
Operation temperatures
- Temperature: 15~40 C
- Humidity: 30~75%
Transport and storage temperatures
- Temperature: -15~50 C
- Humidity: 10~95%

The information contained in this document is subject to change without notice and
should not be construed as a commitment by Comfortel Furniture Pty Ltd.
Comfortel Furniture Pty Ltd. assumes no responsibility for any errors that may appear in
this document nor does it make expressed or implied warranty of any kind with regard
to this material, including, but not limited to, the implied warranties of merchantability
and fitness for a particular purpose.
Comfortel Furniture Pty Ltd. shall not be liable for incidental or consequential damages
in connection with or arising out of the use of this document and the program material.
PRODUCT CODE
PURCHASE DATE INVOICE NUMBER
NOTE YOUR PURCHASE DATE & INVOICE NUMBER FOR FUTURE REFERENCE
#7762 AQUAGLO
A periodic inspection of all components and fasteners
should be made to ensure that your Comfortel
product is structurally intact and functioning properly.
Damaged and broken parts should be replaced and
loose fasteners tightened.
All maintenance to be carried out by a suitably
qualified tradesperson.
GENERAL CLEANING
·We recommend the use of soapy water or
approved cleaners.
·This product should not be cleaned with abrasive
materials.
·Damage caused by any improper treatment is not
covered by the product warranty
MAINTENANCE
CLEANING
PLEASE RETAIN THIS INFORMATION FOR FUTURE REFERENCE
For more information about our products and services, contact us at comfortel.com.au
comfortel.com.au
Revision Date: 11.06.2019
©Comfortel Furniture 1997-2019. All rights are reserved.
No part of this document may be photocopied,
reproduced or translated to another language without
written consent of Comfortel Furniture Pty Ltd.
PERIOD AND DESCRIPTION PRODUCTS
12 MONTHS PARTS & LABOR All products
2 YEARS PARTS ONLY All products excluding small electrical appliances
3 YEARS PARTS ONLY All Linak electric actuators
5 YEARS PARTS ONLY Taps cartridge, Ceramic basins
TERMS AND CONDITIONS
For more information about our terms and conditions including warranty, please refer to our website.
WARRANTY PERIOD
Table of contents
Other comfortel Personal Care Product manuals
Popular Personal Care Product manuals by other brands

HoMedics Beauty
HoMedics Beauty attach&glow Instructions for use

TensCare
TensCare Flexistim Instructions for use

iHome
iHome ZENERGY iZ2 user manual

Orliman
Orliman Arnetec 1000 Use and maintenance instructions

Kinetik Wellbeing
Kinetik Wellbeing HRM4 quick start guide

REH4MAT
REH4MAT AM-GJ-01 quick start guide