Commax CMD-404FU User manual

Floor distributor CMD-404FU/CMD-404FUD
User Manual
•Thank you for purchasing COMMAX products.
•Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
•The company is not responsible for any safety accidents caused by abnormal operation of the product.

1
1. Introduction .......................................................................2
2. Important Safeguard .........................................................3
3. Product Concept and Features .........................................4
4. Wiring diagram .................................................................6
5. Configuration of DEVICE ID & mode ...............................9
6. Specification...................................................................15
Contents

2
Your unit is designed so it can be flush mounted on the or used. When flush mounted on the wall, the stand permils you to the
unit for an gular of unit view. The model number is located on the bottom and record the serial number in the space provided
below(available). Refer to these numbers whenever you call upon your COMMAX dealer regarding this product.
Model No. Serial No.
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
This symbol is intended to alert the use to the presence of uninsulated
“
“dangerous Voltage”
”
within the product’s enclose that
may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the use to the presence of important operating and maintemance(servicing) instructions in the
literature accompanying the appliance
1. Introduction
CAUTION : To reduce the risk of electric shock, do not remove cover(or back) no user-serviceable
part inside refer servicing to qualified service personnel
caution
Risk of electric shock
do not open

3
▲
Damage Requiring Service : This equipment from the power source and source and refer servicing to qualified service per-
sonnel under the following conditions
ⓐwhen the power is damaged.
ⓑif liquid has been spoiled or objects have hallen into the unit
ⓒif the equipment has been exposed to rain or water.
ⓓif the equipment has been dropped or otherwise damaged.
ⓔwhen the equipment exhibits a distinct change in performance- this indicates a need for service.
▲
Water and Moisture : Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry
tub, in a wet basement, or near a swimming pool, and the like.
▲
Accessories : The product may fall, causing serious injury to a child or adult, and serious damage to the appliance. Any
mounting of the manufacture’s instructions, and should use a mounting accessory recommended by the manu-
facturer.
▲
Object and Liquid Entry : Never push objects of any kind into this product through openings as they may touch dangerous
voltage points or short-out parts that could result in a fire or electric shock. Never spill liquid of any
kind on the product.
▲
Lightning : For added protection for this product before a lightning storm, or when it is left unattached and un used for long
periods of time, unplug it from the wall outlet and disconnect the other system. This will prevent damage to the
product due to lightning and power-line surges. If you live in an ared heavily prone to lightning storms, it is recom-
mended that you invest in power-line, telephone-line, RF cable and actuator / polarization surge protectors to pro-
tect your appliance system from possible damage
2. Important Safeguards

4
3. Product Concept and Features
●
CMD-404FU(D) building distributor is used to interlock with floor distributor
(CMD-101BU) and is developed for interlocking Modum system monitor with lobby and
security.
●
CMD-404FU(AC TYPE) is limited to the following devices that can be
connected to interlock.
Lobby phone : Export-oriented type LOBBY (Gate View , Multi panel)
Building distributor: Modum distributor (CMD-101BU) (Required)
Video phone : (AC TYPE) The video phone for 4-wire way Modum system.
(Required)
(CMV-43A/CMV-77K/CMV-43S/CMV-70S)
Adapter (Power): RF-2A
Power(DC24V / 1A) input basically should be advised to be installed
with one power supply r per one CMD-404FU.
CMD-404FUD(DC TYPE) is limited to the following devices that can be
connected to interlock.
※
●

●
CMD-404FU(D) Notes on wiring (It doesn't guarantee the quality of product for
connec-tion if you do not keep the following)
- Wire the "IN" of CMD-404FU(D) with distributor or, CMD-404FU(D) installed with
"OUT" on the floor below
-Wire "LINE 1~4" of CMD-404FU(D) with 2nd CCTV of MODUME system
video phone.(Max 4 Houses connection)
Lobby phone : Export-oriented type LOBBY (Gate View , Multi panel)
Building distributor: Modum distributor (CMD-101BU) (Required)
Video phone : (DC TYPE) The video phone for 4-wire way Modum system.
(Required)
(CMV-43AD/CMV-77KD/CMV-43SD/CMV-70SD)
Adapter (Power): DC24V / 3A (Required)
Power(DC24V / 3A) input basically should be advised to be installed
with one power supply r per one CMD-404FUD. (Required)
※
5

6
- CMD-404FU(D) distribute wires up four houses on one floor and output common 6 lines
after receiving common 6 lines (DATA/GND/LB-TALKA,B/VD_P,N) from
within 30m.
[CMD-404FU] AC-TYPE
- Separate power source must be connected to CMD-404FU.
(DC24V / 80mA or higher) (Required)
In case one source of power is used, then maximum devices connected
should be Eight.
[CMD-404FUD] DC-TYPE
- Separate power source must be connected to CMD-404FUD.
(DC24V / 3A or higher) (Required)
Power(DC24V / 3A) input basically should be advised to be installed
with one power supply r per one CMD-404FUD. (Required)
Distributor(CMD-101BU)
- Maximum 79 CMD-404FU(D) can be operated within 300 meter from lobby or
CCTV. - Thedistant from floor di stri butor(CMD -404FU(D))to Mo dum System
video phone is
※

7
●Floor distributor should be connected with 2nd terminal of camera (Caution: When
interlocking or expanding with external device, do connect two or more video phone.
AC-TYPE
CMD-404FU: (AC TYPE) The video phone for 4-wire way Modum system.(Required)
(CMV-43A/CMV-77K/CMV-43S/CMV-70S)
Adapter (Power): RF-2A
Power(DC24V / 1A) input basically should be advised to be installed with one
power supply r per one CMD-404FU.
DC-TYPE
CMD-404FUD: (DC TYPE) The video phone for 4-wire way Modum system. (Required)
(CMV-43AD/CMV-77KD/CMV-43SD/CMV-70SD)
Adapter (Power): DC24V / 3A (Required)
Power(DC24V / 3A) input basically should be advised to be installed with one
power supply r per one CMD-404FUD. (Required)
※
※

8
4.
Wiring diagram
●
CCTV / LOBBY Building distributor(CMD-101BU)
CMD-404FU(D)(1ST FLOOR) CMD-404FU(D)(1ST FLOOR)
CMD-404FU(D)(2ND FLOOR) ... MODUME VIDEO PHONE
: UTP CABLE [CAT.5e] - MAX 300m

9

10

11
●OPTION (Use for easy connection: CMD-101BU/CCU-204AGF LINE BOARD)
CASE : MODUM SYSTEM + AUDIO GATE SYSTEM

5. Configuration of DEVICE ID & MODE for Household Unit Number
registration
※ The following CMD-404FU(D) Configuration must be done before setting
MODUM SYSTEM Lobby Camera Phone.
- When configuring the Device ID, set up Dip switch on the back panel of the product.
Different ID should be used when installing the multiple floor distributor.
12

●
13
●
Functions for each switches
# 1 (Select MANUAL /AUTO) : OFF= MANUAL / ON=AUTO
# 2 ~4 (ID configuration: 10 digit figure) : Composed of BCD code (Refer to picture
below)
# 5~6 (ID configuration: single digit figure) : Composed of BCD code (Refer to picture
below)

●Number description method by switches (There are three 10 digit figure switches
which can be used to seven)
[''Enter ten digit number : 0~7] ['Enter single digit number: 0~9]
** ID configuration range: 1 ~ 79(MAX) room number can be entered. **
14

15
●Auto / Manual mode function
Auto Mode (ON): When booted with number one switch on, it operates with auto mode.
Room numbers are allocated sequentially by the ID number configured.
(Building # is fixed as #101, designated ID X '4' will be final channel of room #)
Ex) When ID = 1 configured
Channel 1 (Line1) = Block 101 unit 1
Channel 2 (Line2) = Block 101 unit 2
Channel 3 (Line3) = Block 101 unit 3
Channel 4 (Line4) = Block 101 unit 4
(1(ID#) X 4 = 4[ Last channel unit number is designated as 4])
Ex) ID = 79(max) configured
Channel 1 (Line1) = Block 101 unit 313

Channel 2 (Line2) = Block 101 unit 314
Channel 3 (Line3) = Block 101 unit 315
Channel 4 (Line4) = Block 101 unit 316( 79(ID#) X 4 = 316
[Last channel unit number is designated as 316])
** Reference: On Auto Mode block number is fixed as 101.**
Manual Mode (OFF): When booted with number 1 switch off, it operates on MANUAL
mode. Irrelevant to ID number configured, you can directly set up the block and unit num-
ber from external device(Lobby phone)
Caution
You can only set up MANUAL Mode from separate lobby phone (program mode
supported 36
After DEVICE ID and mode is set, it should be booted with adapter power OFF/ON
If there was a connection of the common power, it should be reconnected after
the “IN” PORT UTP cable was disconnecte
16

17
When you register the lobby information to floor distributor from the lobby phone, this floor
distributor will be set with the building No. of lobby phone.
After that, the household unit which is connected with this floor distributor can check the
image of lobby phone during monitoring mode
●Initialization
When you turn on the product after you set up all switch on or off, then factory reset will be
initiated.
(Initial value = Block101 Unit 1(line1), Unit 2(line2), Unit 3 (line3), Unit 4 (line4) )
Caution : Product only operates after OFF/ON when configured.

18
6. Specification
CMD-404FU / CMD-404FUD [Floor Distributor]
Building distributor(CMD-101BU) 6 lines (Polarity), MODUME
VIDEO-PHONE 4 lines (Polarity)
(RJ45 CAT5e Patch Cable)
Voltage
1.
MODUM System building distributor(CMD-404FU(D))
CMD-404FU(D) IN (Input)
2.
CMD-404FU(D) OUT(Output) Upstairs CMD-404FU(D) IN (Expansio
3.
CMD-404FU(D) LINE1,2,3,4 Monitor (MODUM System video phone)
Maximum 300m : Main entrance
monitor, the distance from each floor
distributor to each monitor is limited by 30m.
(79 floor distributor can be interlocked)
Model
Spec
Transmission type
Wiring Sequence
Wiring distance
CMD-404FU : DC 24V / 80mA (MAX)
CMD-404FUD : DC 24V / 3A (MAX)

19
MEMO
This manual suits for next models
1
Table of contents
Other Commax Amplifier manuals
Popular Amplifier manuals by other brands

EUROCOM
EUROCOM SN2408 manual

ATI Technologies
ATI Technologies AT7000 Series owner's guide

Rockford Fosgate
Rockford Fosgate Punch PM300X1 Installation & operation

Factor Electronics
Factor Electronics PA-1000 User and installation manual

Arylic
Arylic S10 user manual

Musical Fidelity
Musical Fidelity X-A1 Instructioms for use