Commax JNS-36 User manual

513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea
Int’l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133
Web site : www.commax.com
User Manual
•Thank you for purchasing COMMAXproducts.
•Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
•The company is not responsible for anysafety accidents caused byabnormaloperation of the product.
NURSE CALL SYSTEM JNS-36(Series)
Printed In Korea/ 2010.04.101
User Manual
POWER
VOLUME TONE
BUSY
LOCK TALK

JNS-36 Series JNS-600 Series JNS-1000 Series
System
Features
System type Analogue Analogue Digital
Nurse Stations JNS-12/24/36
JNS-6012M/6028M/6044M/6060M
JNS-1060M/1108M
Patient Station JNS-101 JNS-102 JNS-1050M/1050S
Central controller
JNS-6012, 6060 JNS-1060, 1108
2 common+ 1 common+
1 individual 2 individual
wire
5pair(10wires)common
Max
acconmodation
Max 36 beds
(36 stations call
&
communication)
a. Max 36 beds
(30 ststions call &
communication)
b. 8 rooms of public
toilets(emergency)
a. Max 29wards of 108 beds
(1080 stations call &
communication)
b. Max 29 ward's shower room &
toilets. (emergency function)
c. 16 rooms of public toilets
(emergency function)
Available
functions
a. Corridor light
a. Corridos light
b. Master to Master talk
(Max 6 stations)
c. Call cord only.
d. Guiding light
a. Corridor light/Guiding light
b. Master to Master talk
(max 90 stations)
c. Presence switch.
d. Staff call
e. Emergency switch.
f. Call cord & pillow speaker
g. Compatible with TP-90AN
upto 90 station's communication
of nurse and staff stations.
Effective distance Max 1,000m Max 500m Max 500m
-1-
Introduction
Established in 1968 Jung Ang Electronics Co., Ltd. has specialized in the field of
intercommunication system for 27 years, and and now it is our greatest pleasure to present a
highly advanced hospital communication network system which we assure to level up your
hospital culture.
Nurse call system introduction
We have three types of unrse sall system as below table.

-2-
Table of Contents
Introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
Nurse call System introduction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
Contents table - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
Manual of JNS-36 Series - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
1. Model No - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
2. Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
3. Structure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
4. System Working diagram - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
5. Figure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5
6. Connection Diagram - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
7. Operating Instruction - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
8. Specification - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7
9. Warranty Service - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 7

-3-
Manual of JNS-36 Series
1. Model No
The model No of the nurse call system would be devided by it's accomodating interphone station
number as belows;
2. Features
2-1. Clear communicating line.
2-2. You can adjust each call volume and talk volume separatly.
2-3. When a call receiving. LED lamp turn off automatically.
2-4. When a communicating, the lamp of the line will be on.
2-5. Two way communication.
2-6. Hands-fred talk function.
No Wiring station No MODEL No ETC
1 8wire 6 station JNS-6 Basic Case
2 14 wire 12 station JNS-12 Basic Case
3 20 wire 18 station JNS-18 Basic Case
4 26 wire 24 station JNS-24 Basic Case
5 32 wire 30 station JNS-30 Basic Case
6 32 wire 36 station JNS-36 Basic Case
7 44 wire 42 station JNS-42 additional case
(order made)
station number
+ 2wire add ed. up
by 6 stations JNS-
station No.

-4-
POWER
VOLUME TONE
BUSY
LOCK TALK
3.STRUCTURE
3-1. MASTER STATION
①HAND SET :
②POWER LED : To check the Power Switch's condition.
③POWER S/W : To provide a power.
④C-MIC : To transmit a message.
⑤BUSY LEN : To indicate busy line by lamp On.
⑥LOCK BUTTON : Only to transmit a message in one way, the lamp is on.
⑦TALK BUTTON : To press the button for talking. (during H/F communicating)
⑧VOICE : To adjust receiving volume by three stage, High, Mid & Low.
⑨TONE : To adjust receiving signal by three stage, High, Mid & Low.
⑩SPEAKER : To output the message.

-5-
CALL TALK
CALL CORD MIC
3-2. SUB STATION
4. System working diagram
5. Figure
①SPEAKER :
②CALL JACK : Can be connected with
call cord CC-200.
③CALL BUTTON : To call a master.
④C-MIC :
⑤CANCEL BUTTON : To cancel a call.
⑥CALL LAMP : LED's off in calling.
⑦TALK LAMP : LED's on in talking.
MASTER STATION (JNS-36) SUB STATION (CM-200)SUB STATION
(W/ARM SWITCH)

-6-
6. Connection diagram
7. Operating Instruction
7-1. When call a sub station in master.
7-2. When call a master in substation.
•common two wire and individual one wire
①Please press a select button that you want then a LED in the button is "ON".
②With hand-set communicating you can talk in two way communication.
③Under using a intercom way of communication, You can talk through talk button.
①With pressing the call button in substation the LED Lamp in master is "ON" and Melody is
transmited.
②The call Lamp & corrider lights will be "OFF" at same time.
③Please press the master button or lift up the hand set to talk.
④Please return the select button after finishing a talk.

-7-
9. WARRANTY SERVICE INSTRUCTIONS
8. SPECIFICATIONS
Wiring Common 2 wires and individual 1 wire
Power AC 110V/220V (60Hz)
Power consumption in standdoy DC 24V (22mA)
Max power consumption DC 24V (190mA) in one line
Communication Way Two way communication system
Distance 600m/0.65mm
Station Number Max 36 sub stations
Dimension 360(W) x 232(D) x 105(H)mm
Model No
Divison
If you experience a problem with your JNS-36 Nurse Call System, please refer to the
"Operating Instructions" sections of this Owner's Manual to review the proper operation. Check
the power source to insure adequate power available to operate the JNS-36 System.
If the JNS-36 still will not function, please return the unit (with proof of purchase) to the place of
purchase.
FOR YOUR RECORDS
Purchase Date:
Purchased From:
Serial Number:
KEEP THIS INFORMATION
IN A SAFE PLACE.

Memo
Table of contents
Other Commax Cordless Telephone manuals