manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CommScope
  6. •
  7. Amplifier
  8. •
  9. CommScope BUDI-2S User manual

CommScope BUDI-2S User manual

Popular Amplifier manuals by other brands

ASTRO HVO V40 P operating manual

ASTRO

ASTRO HVO V40 P operating manual

Marantz SUPERSCOPE BLA-545 Service data

Marantz

Marantz SUPERSCOPE BLA-545 Service data

NAD CI980 Quick setup guide

NAD

NAD CI980 Quick setup guide

Technics SE-CH770 Service manual

Technics

Technics SE-CH770 Service manual

Harman Kardon HK6300 instruction manual

Harman Kardon

Harman Kardon HK6300 instruction manual

NAD T975 owner's manual

NAD

NAD T975 owner's manual

McIntosh MA6850 Brochure & specs

McIntosh

McIntosh MA6850 Brochure & specs

Electro-Harmonix ENGLISH MUFF’N manual

Electro-Harmonix

Electro-Harmonix ENGLISH MUFF’N manual

Viatron Autrix Technical manual

Viatron

Viatron Autrix Technical manual

GME GA9800 instruction manual

GME

GME GA9800 instruction manual

Atlas CP700 Specification sheet

Atlas

Atlas CP700 Specification sheet

Roland KC-1000 owner's manual

Roland

Roland KC-1000 owner's manual

Pyle PFMRA350BW user manual

Pyle

Pyle PFMRA350BW user manual

Advantage S-250 manual

Advantage

Advantage S-250 manual

IRT Electronics DVA-3007 manual

IRT Electronics

IRT Electronics DVA-3007 manual

Dimavery BA-100 Series user manual

Dimavery

Dimavery BA-100 Series user manual

Sony XM-S400D operating instructions

Sony

Sony XM-S400D operating instructions

Schertler ROY X quick guide

Schertler

Schertler ROY X quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

BUDI-2S
INSTALLATION INSTRUCTION
Building distributor
Introduction
Suitable for FTTH applications where easily pre-connectorized splitters
modules can be build in.
1.2 Blown fiber application, with splitter configuration.
1 Kit configurations
1.1 Blown fiber application , no splitter configuration.
1.3 Drop cable application.
2.1.1 Strip the outer jacket over a length of 1.5 m and leave some
aramid strength member to install onto the termination unit.
2 Installation
2.1 Drop cable application
2.1.2 Install the termination unit onto the cable.
TC-925-IP
Rev A, Mar 2017
www.commscope.com
2.1.5 Cut into the rubber seal to open the cable port.
2.1.3 Slide the termination unit to the end of the outer jacket and
route the aramid strength member in the groove under need the
termination unit and route the aramid strength member back to the front
in between the termination unit and the outer jacket. Install a tie-wrap
around the termination unit and the cable.
2.1.6 Install the cable with the termination unit into the box, Click the
termination unit in one of the ports foreseen for the termination units and
install the cable in the rubber seal. Start with termination unit positions
1, 2, 3 and finally 4.
2.1.4 Cut the overlength of the aramid strength member.
2.2.1 Open the wrap around rubber seal.
2.2 Blown fiber application
1
2
3
4
2.3.1 Route the fibers to the storage area. All fibers should enter
through this port.
2.2.2 Install the tube with fiber into the cable entrance and secure
with the tie-wrap.
2.2.3 Close the wrap around rubber seal with the top part.
2.3 Fiber routing
2.3.2 Fibers who will be spliced can be stored in this storage area,
fibers who will be used later should be routed to the dark storage area
trough the port shown on the picture.
This to avoid crossing when dark fibers has to be spliced later.
Splice 1-6
Splice 7-12
2.3.3 Connect the pigtails into the designated adaptors.
2.4.1 Install the splitter into the splitter holder, take care of the
orientation. Splice the incoming fiber of the splitter to the fiber cable.
Store the overlength into the storage area.
2.3.6 Close the storage area with the dark fiber storage tray.
2.3.4 The pigtails should be stripped when entering the storage area
in a straight line.
2.4 In case of splitters
2.3.5 Splice the pigtails and store the splices in the splice holder, first
use the left holder as shown on the picture, this to avoid crossings when
adding a new incoming cable.
2.4.2 Install the outgoing pigtails of the splitter into the designated
adaptors. Store the overlength into the storage area.
2.5.1 Install the patchcords into the designated adaptors.
2.5.3 Install the patchcords into the designated adaptors and install
them into the rubber seal one on top of the other as shown on the
picture.
2.5 Patchcords
2.5.2 Cut open the ports needed for the patchcords.
2.5.4 Close the box.
© 2017 CommScope, Inc. All rights reserved.
All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc.
This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to
CommScope products or services.
This product is covered by one or more U.S. patents or their foreign equivalents. For patents, see:
www.commscope.com/ProductPatent/ProductPatent.aspx.
To find out more about CommScope® products, visit us on the
web at www.commscope.com
For technical assistance, customer service, or to report any
missing/damaged parts, visit us at:
http://www.commscope.com/SupportCenter