CommScope FACT NG4 User manual

860648849
Rev. A Page 1 of 11
© 2018 CommScope, Inc. All Rights Reserved
Contents
Installation Instructions
FACT NG4 CHASSIS FOR MODULES & ADAPTER PACKS
TC-40161-IP-EN
Rev A, March 2019
www.commscope.com
1. General product information
The universal FACT NG4 chassis (FACT-xENG4) for modules & adapter packs supports the NG4-access connectivity
packs and modules that easily snap in the chassis. It accommodates SC, LC and MPO adapter packs, MPO-modules
(MPO to LC, or MPO to SC), Cabled modules (CMOD) and Value-added modules (VAM).
2. Warnings and caution
• Fiber optic cables may be damaged if bent or curved to a radius that is less than the recommended minimum
bend radius. Always observe the recommended bend radius limit when installing ber optic cables and patch
cords.
• Exposure to laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical
ber. Do not assume the laser power is turned o or that the ber is disconnected at the other end.
• Pay attention to the routing of the patch cords. These should move/hang freely, where they leave the bend control.
If you see that there is tension occuring on the patch cords, please reroute these.
1. General product information ................................................ 1
2. Warnings and caution ............................................................ 1
3. Product image......................................................................... 2
4. Kit content............................................................................... 2
5. Mounting FACT chassis in rack ............................................. 2
5.1. Mounting FACT chassis ............................................................................. 2
5.2. Dismounting FACT chassis........................................................................ 2
6. Installation of the modules ................................................... 3
7. Routing the patch cords (modules)..................................... 5
8. Installation of the adapter packs...........................................7
9. Routing the patch cords (adapter packs) ............................ 9
10. Trademarks............................................................................11
11. Contact Information..............................................................11

Page 2 of 11
© 2018 CommScope, Inc. All Rights Reserved
3. Product image
Note: FACT chassis with LC-Adapters shown as example.
4. Kit content
• FACT element NG4
• Brackets
• Color coding labels
• Transparent pockets with labels
5. Mounting FACT chassis in rack
5.1. Mounting FACT chassis
5.1.1. Prepare the rack with the brackets on the position
where you want to install the FACT chassis (by sliding them
in ).
5.1.2. Take the FACT chassis with both hands and align
with the brackets on both sides.
5.1.3. Slide the FACT chassis into the ngers until you
hear a “clicking noise”.
5.2. Dismounting FACT chassis
5.2.1. Open upper drawer (releasable).
Note: empty drawer is shown. This one is marked at the front
(blue marking at the bend control).
5.2.2. Pull the blue puller locks (make sure both sides
-left & right- are in the unlocked position).

Page 3 of 11
© 2018 CommScope, Inc. All Rights Reserved
5.2.3. Slowly slide the FACT chassis out (pull simultaneously
on both sides, with both hands).
Note: empty drawer is shown.
6. Installation of the modules
6.1. FACT element is provided with 2 trays (1 module per
tray) per drawer.
6.2. To access the bottom tray, remove the velcro and
rotate the top tray to a 90° position.
6.3. Use the latch to detach the insert on the desired
side.
6.4. Remove the insert.
6.5. Align the module in on the side where the insert
was removed, by placing it on top.
6.6. Align the module as illustrated. Don’t push it in yet.
12
34
5
3

Page 4 of 11
© 2018 CommScope, Inc. All Rights Reserved
4
6.7. Align the module as illustrated. Don’t push it in yet.
6.8. Push in snapping feature number 1.
6.9. Push in snapping feature number 2.
6.10. Push in snapping feature number 3.
6.11. Push in snapping feature number 4.
6.12. Push in snapping feature number 5.
4
1
2
3
4
5
4

Page 5 of 11
© 2018 CommScope, Inc. All Rights Reserved
6.13. SC-MPO Module installed.
6.14. VA Module installed.
6.15. LC-MPO Module installed
6.16. Cabled Module installed.
7. Routing the patch cords
(modules)
7.1. Open the bend control cover. Unlatch the snapping
feature (on the backside of the bend control) as shown.
7.2. The retaining feature can be opened (hinged back) if
additional space is needed (optional).

Page 6 of 11
© 2018 CommScope, Inc. All Rights Reserved
7.3. Open the back lid by pushing the snap feature to
the inside and then lifting the lid.
7.4. Route the patch cords through the rst bend as
illustrated. Use 3 patch cords per bend control for the SC-
MPO Module. Clean the connectors before installing!
7.5. Route the patch cords through the rst bendµ as
illustrated. Use 6 patch cords per bend control for the VA
Module. Clean the connectors before installing!
7.6. Route the patch cords through the rst bend as
illustrated. Use 6 patch cords per bend control for the LC-
MPO Module. Clean the connectors before installing!
7.7. Route the patch cords through the rst bend as
illustrated. Use 6 patch cords per bend control for the Cabled
Module. Clean the connectors before installing!
7.8. Route the patch cords to the back side of the FACT
element.

Page 7 of 11
© 2018 CommScope, Inc. All Rights Reserved
7.9. When you route both trays, it should look as
illustrated.
7.10. Carefully close the back lid.
7.11. Close the bend control cover (retaining feature
down).
7.12. Route the patch cords through the trumpet.
7.13. Before closing the drawer, pay attention to the patch
cord routing.
8. Installation of the Adapter
Packs
8.1. FACT element is provided with 2 trays (2 apapter
packs per tray) per drawer.

Page 8 of 11
© 2018 CommScope, Inc. All Rights Reserved
8.2. To access the bottom tray, remove the velcro and
rotate the top tray to a 90° position.
8.3. Align the Adapter Packs.
8.4. Make sure that features 1, 2 & 3 are aligned
correct.
8.5. Align feature number 1 and push it in (ush with
edge).
8.6. Align snapping feature number 2 and push it in.
8.7. Align snapping feature number 3 and push it in.
3
12
3
1
2

Page 9 of 11
© 2018 CommScope, Inc. All Rights Reserved
8.8. SC-SC Adapter Packs installed.
8.9. LC-LC Adapter Packs installed.
8.10. MPO-MPO Adapter Packs installed.
9. Routing of the patch cords
(Adapter Packs)
9.1. Open the bend control cover. Unlatch the snapping
feature (on the backside of the bend control) as shown.
9.2. The retaining feature can be opened (hinged back) if
additional space is needed (optional).
9.3. Open the back lid by pushing the snap feature to
the inside and then lifting the lid.

Page 10 of 11
© 2018 CommScope, Inc. All Rights Reserved
9.4. Route the patch cords through the rst bend as
illustrated. Use 3 patch cords per bend control for the SC-SC
Adapter Packs. Clean the connectors before installing!
9.5. Route the pach cords through the rst bend as
illutrated. Use 6 patch cords per bend control for the LC-LC
Adapter Packs. Clean the connectors before installing!
9.6. Route the patch cords through the rst bend as
illustrated. Use 2 patch cords per bend control for the MPO-
MPO Adapter Packs. Clean the connectors before installing!
9.7. Route the patch cords to the back side of the FACT
element.
9.8. When you route both trays, it should look as
illustrated.
9.9. Carefully close the back lid.

Page 11 of 11
© 2018 CommScope, Inc. All Rights Reserved
9.10. Close the bend control cover (retaining feature
down).
9.11. Route the patch cords through the trumpet.
9.12. Before closing the drawer, pay attention to the patch
cord routing.
10. Trademarks
All trademarks identied by ® or ™ are registered
trademarks or trademarks, respectively, of CommScope,
Inc. This document is for planning purposes only and is
not intended to modify or supplement any specications
or warranties relating to CommScope products or services.
CommScope is committed to the highest standards of
business integrity and environmental sustainability, with a
number of CommScope’s facilities across the globe certied
in accordance with international standards, including ISO
9001, TL 9000, and ISO 14001.
Further information regarding CommScope’s commitment
can be found at
www.commscope.com/About-Us/Corporate-Responsibility-
and-Sustainability.
11. Contact information
Visit our website or contact your local CommScope
representative for more information.
For technical assistance, customer service, or to report any
missing/damaged parts, visit us at:
http://www.commscope.com/SupportCenter
This product may be covered by one or more U.S. patents or
their foreign equivalents.
For patents, see www.cs-pat.com
Table of contents