Product Introduction
Door sensor is an intelligent security equipment that can transmit through Z-wave network and radio
waves. In the Z-wave network communications, door sensor can be connected to any Z-wave gateway.
Door sensor can send messages to Z-wave gateway, then realize association with other devices. Different
countries or areas, the radio frequency is different.
Each door sensor has a unique ID code. When we add or remove door sensor from gateway, just place it in
the z wave network range of gateway. Then we can easily find the door sensor through device ID code.
In the communication with Z-wave gateway, door sensor can only send messages to Z-wave
gateway, but can not receive messages. When alarm is triggered, door sensor would send messages to
gateway, then Z-wave gateway would display the current status of door sensor. At the same time, door
sensor can realize association with other devices through z wave gateway. Door sensor is powered by
batteries, with small body , and can be installed on the window or door easily. When door or window is
open, door sensor would be triggered, then associates with other devices to work, to realize the goal of
safety protection.
TECHNICAL SPECIFICATIONS
TECHNICAL PARAMETERS
Power
CR2-3V x1
Standby Current
1uA
Battery Life
1 Year
Radio Protocol
Z-wave
Radio Frequency
865.2MHz IN
Compatible with
300 Series and 500 Series
Wireless Distance
Upto 60m Outdoor, Upto 30m Indoor
Operation Temperature
0- 45℃
Storage Temperature
0 -60℃
Size
Door sensor main body (L x W x H):
71mmX20mmX22mm
Door sensor deputy body (L x W x H):
40mmX11mmX11mm
TECHNICAL INFORMATION
Installed on the door or window
Battery powered
Easily installed with screws or sticker
Associate with other devices through gateway
Compatible with any Z-wave network
Product Configuration
Figure 1
Items List
Door sensor main body - 1No.
Door sensor deputy body - 1No.
Battery - 1No.
Screw - 4Nos.
Screw Stopper - 4Nos.
Sticker -2Nos.
User Manual - 1No.
Installation Steps
Door Sensor Installation.
Battery Installation.
Door Sensor Installation
Step 1 :
Dismantle the door sensor main body and take out the battery, fix the main body on the door with
screws.
Dismantle the door sensor deputy body and fix it on the corresponding door frame position.
Figure 2
Step 2 :
Put the sticker on the bottom of door sensor then fix it on the wall
Figure 3
Note:
When installing door sensor, door sensor deputy body must be installed on the bulge side of the
door sensor main body.
Battery Installation
Figure 4
Tips
When installing the door sensor, the distance between main body and deputy body should be less
than 2cm in the state of door closed.
When door is closed, that is to say, distance between main body of door sensor and deputy body
is less than 2cm, app would display door is closed.
When door is opened, that is to say, distance between main body of door sensor and deputy body
is more than 2cm, the app would display the door is opened. Through gateway, door sensor can
associate with IP camera to take pictures and record video, siren to alarm.
Make sure door sensor is placed in the Z-wave network range of gateway.
Battery Usage Tips
Battery life of door sensor is approximately 1 year. The power level of battery would be displayed in the
gateway. Red icon means the battery needs replacing, and then mobile app would receive a message
“Power level is low, Please remember to replace battery”from gateway. In order to avoid false alarm,
before replacing battery, please disconnect association of door sensor with other devices.
Note:
Door sensor is powered by battery, and please use battery in a correct way to avoid exploding.
When handling the battery, refer to environmental law please.
The status of LED
1. When door sensor is triggered, LED lights would flash red color 1 time.
2. When door sensor is installed with battery, LED lights would flash red color 5 times.
3. Add or Remove door sensor from Z-wave network by quickly pressing the button 3 times , then
LED lights would flash red color 5 times.
4. Press and Hold the code button for 10-15 seconds, then door sensor would be restored to factory
default settings. Meanwhile, LED lights would flash red color 5 times on and off alternately.
5. Under the normal state, LED lights would keep “off “state.

Add Door sensor to Z-wave Network
Door sensor can be included to Z-wave network by pressing the code button.
1)Disassemble the main body of door sensor by pressing the disassemble button, then install battery.
After making it powered on, please do not operate it within 20s.
2) Place door sensor within z wave network range of gateway.
3) Set Z-Wave gateway into inclusion mode (Refer to gateway user manual)
4) Press the code button in door sensor three times continuously, then door sensor will enter inclusion
mode. Meanwhile, LED light would flash red color five times on and off alternately.
5) Door sensor will be detected and included in the Z-wave network.
6) Wait for gateway to configure the sensor.
Remove Door sensor from Z-wave Network
1)Make sure door sensor is powered on.
2) Set Z-Wave gateway into exclusion mode (Refer to gateway user manual)
3)Press the code button in door sensor three times continuously, then door sensor will enter exclusion
mode. Meanwhile, LED light would flash red color five times on and off alternately.
4) Wait for gateway to remove the sensor.
Note:
During the process of resetting, please make sure door sensor is powered on all the time.
Associations (Association Command Class Version 2)
This Sensor supports 4 association groups. Every group can be supported to associate 5 devices max.
This has the effect that when the sensor is triggered, all devices associated with it will receive relevant
reports. Through association, door sensor can control another Z‐Wave network device, e.g. a alarm device,
wall plug, lamp etc.
GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector) status –Open/Close.
It enables the sensor to send reports and readings to Z‐Wave Gateway whenever the sensor is triggered.
This Group Support:
NOTIFICATION_REPORT
BATTERY_REPORT
SENSOR_BINARY_REPORT
DEVICE_RESET_LOCALLY_NOTIFICATION
GROUP 2 allows sending control commands to associated devices such as relay module, lighting, etc.
This association group is configured through the advanced parameters no. 1 and no. 2.
This Group Support:
BASIC_SET.
GROUP 3 allows Sending Notification to associated devices in this group.
This Group Support:
NOTIFICATION_REPORT
GROUP 4 allows for Send Notification to associated devices in this group.
This Group Support:
SENSOR_BINARY_REPORT
Advanced Configuration
1. Configuring the OFF Delay
This configuration parameter can be used to adjust the amount of delay before the "OFF" command is
transmitted. This parameter can be configured with the value of "0" through "65535", where "0" means
send "OFF" command immediately and "65535" means "65535" seconds of delay.
Function : On/Off Duration.
Parameter Number : 1.
Parameter Size : 2 Byte
Available Settings : 0-65535 (in seconds, each 1s).
Default Setting : 0(s).
2. Basic Set Level
Basic Set Command will be sent where contains a value when the door/window is opened or closed, z
wave controller or z wave gateway will take it for consideration; for instance, if a lamp module receives the
Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be.
Function : Basic Set
Parameter Number : 2
Parameter Size : 1 Byte
Available Settings : 0, 1 - 99 or 255
0 –OFF, Alarm cancelling or turning a device off.
1 - 99 o 255 –ON (Binary Switch Device).
Dim Level (Multilevel Switch Device).
Default Setting : 255
Notification Command Class
Once the detector detects the magnet of sensor is to be opened, it will send NOTIFICATION_REPORT and
SENSOR_BINARY_REPORT to the nodes of lifeline to inform there is an intrusion event. When the magnet
is to be closed, NOTIFICATION_REPORT and SENSOR_BINARY_REPORT will be sent again to the nodes in
lifeline.
For compliant to Z‐Wave 300 Series, There also realize the Binary Sensor Command Class.
Notification Report Command
Event Present:
Command Class : COMMAND_CLASS_NOTIFICATION
Command : NOTIFICATION_REPORT
Notification Type :NOTIFICATION_TYPE_ACCESS_CONTROL3
Event : NOTIFICATION_EVENT_ACCESS_CONTROL_WINDOW_OR_DOOR_IS_OPENED
Event Clear:
Command Class : COMMAND_CLASS_NOTIFICATION,
Command : NOTIFICATION_REPORT
Notification Type : NOTIFICATION_TYPE_ACCESS_CONTROL
Event : NOTIFICATION_EVENT_ACCESS_CONTROL_WINDOW_OR_DOOR_IS_CLOSED
Binary Sensor Report Command
Event Present:
Command Class : COMMAND_CLASS_SENSOR_BINARY
Command : SENSOR_BINARY_REPORT
Sensor Type : SENSOR_DOOR_WINDOW
Value : 0xFF
Event Clear:
Command Class : COMMAND_CLASS_SENSOR_BINARY
Command : SENSOR_BINARY_REPORT
Sensor Type : SENSOR_DOOR_WINDOW
Value : 0x00
Wakeup Command Class
Door sensor stays in dormant state for the majority of time in order to conserve battery life.
The minimum wakeup interval is 300s (5 minutes)
The maximum wakeup interval is 16,777,200s (about 194 days)
Allowable min step among each wakeup interval is 60 seconds, such as 360s, 420s, 480s…
Note: The default value is 12 hours. The larger the value is, the greater the battery life is.
Battery Check Command
Users can also enquire the battery status of door sensor by sending BATTERY_GET command. Once door
sensor receives the command, it will return BATTERY_REPORT command. Door sensor would send
BATTERY_LEVEL = 0xFF command to Z‐Wave gateway to inform that door sensor is in dead battery status,
otherwise BATTERY_LEVEL value range is 0% to 100%.
Command Classes
This Sensor(Door/Windows Detector) supports Command Classes as Below:
* COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
* COMMAND_CLASS_VERSION (V2)
* COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
* COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
* COMMAND_CLASS_POWERLEVEL (V1)
* COMMAND_CLASS_BATTERY (V1)
* COMMAND_CLASS_ASSOCIATION (V2)
* COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
* COMMAND_CLASS_WAKE_UP (V2)
* COMMAND_CLASS_NOTIFICATION (V4)
* COMMAND_CLASS_SENSOR_BINARY (V2)
* COMMAND_CLASS_CONFIGURATION (V1)
For any technical and support queries, please contact
CONFIO TECHNOLOGIES PRIVATE LIMITED
276, 7TH MAIN, JP NAGAR 4TH PHASE,
BANGALORE-560078
KARNATAKA –INDIA
EMAIL: [email protected]
Mobile: +91-80-4809 4848
Serial Number:
Dealer Code:
Installation Date:
Stamp: