4
3. Programming
Box 485-4 is from the factory delivered with a standard programming. Further pro-
gramming can be made through the PC Interface (PCI2000 or LogBox3).
3.1 Programming positions
Position Programming
100 Address(IDnumber)ofrstslave(keypad)
101 Address (ID number) of second slave (keypad)
102 Address (ID number) of Box 485-4
103 Relay mask for relay 1
104 Relay mask for relay 2
105 Relay mask for relay 3
106 Relay mask for relay 4
107 Pre-activation time of slave relay 3 (master relay is relay 1)
108 Pre-activation time of slave relay 4 (master relay is relay 2)
109 Relay activation time for exit button, ¼ second
110to122 Allowedtimezonesfortherstandsecondslavekeypad,
reserved for future development
123 Active mask,
reserved for future development
3.2 Default programming
Position Value Programming
100 1 Address(IDnumber)ofrstslave(keypad)
101 1 Address (ID number) of second slave (keypad)
102 200 Address (ID number) of Box 485-4
103 incactive Relay mask for relay 1 is group 0, 1, 2 and 3
104 inactive Relay mask for relay 2 is group 4, 5, 6 and 7
105 inactive Relay mask for relay 3 is group 8, 9, 10 and 11
106 inactive Relay mask for relay 4 is group 12
107 0 Pre-activation time of slave relay 3 is 0
108 0 Pre-activation time of slave relay 4 is 0
109 4 Relay activation time for exit button, 1 second
110 to 122 255 Reserved for future development (must be value 255)
123 127 Reserved for future development (must be value 127)