THE BOX
QR code
Part number
Product name
UNBOXING
• The Conventional Expander Module has removable top and bottom front plastics to cover screw housings.
• The Conventional Expander Module is housed in an IP65 rated box, with knockouts for IP rated
glands.
• 4 plastic screws are provided to secure the lid.
For more information, please refer to the complete product manual.
IMPORTANT TO CONSIDER
When mounting a wireless device a comprehensive radio survey
should have been carried out to establish the location that provides
the best coverage and optimum reach. Taking into consideration the building
structure and materials, the survey identifies the wireless infrastructure
required and product locations for optimum performance, identifying
any factor that could prevent radio integrity.
Avoid fixing or mounting the unit close to the following:
• Equipment that utilises large electrical currents
• Large metal objects or structures
• Fluorescent lighting fittings
• Metal ceiling structures
• IT cabling.
Keep 2 meters minimum spacing between other wireless equipment
in the area to avoid signal interference.
EN54 approved environmental temperature range is -10°C to +55°C
MOUNTING STEPS
The Conventional Expander Module is IP65 rated, suitable for external mounting. The back box must be installed on the wall as flat
as possible to retain IP rating, to prevent distortion of the housing and the ingress of contamination and/or moisture.
Proceed as follows to complete the device installation.
Remove top and bottom front plastics that cover screws,
unscrew all four screws and remove the lid from the back box.
1
3
2
4
5
Using a suitable-sized drill bit (4mm) drill the pre-defined
screw mounting points in the 4 corners of the backbox.
6
SCREWS
Remove the electronic PCB assembly from the enclosure.
The PCB is held by two Philips screws below the display,
it then slides up and out.
Prepare apertures (20mm knockouts) required for cable
access and fit appropriate rated glands.
Screw the back box to the wall using all fixing holes
and appropriate-sized roundhead screws (do not use
countersunk screws). Insert cable, tighten glands and refit PCB and securing screws.
MOUTING HOLES
SCREWS HOLES
NO
YES
TAU-CEM-01
HYFIRE TAURUS CONVENTIONAL EXPANDER MODULE
QUICK START GUIDE
TAU-CEM-01
Hyfire Taurus
Conventional Expander Module
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP
T: +44 (0)1926 485282, E: info@hyfirewireless.co.uk, W: www.hyfirewireless.com
INSIDE THE BOX
• 1 x Conventional
Expander Module
• 4 x Screws
• 1 x Product Manual
• 1 x Quick start guide
• 1 x QR code
L50-MEC-1400 (Rev_P.2)
• Connect the conventional zone line’s terminals to the
relevant connector.
• Install the Alarm and the Line EOL resistors and connect
to the relevant connector. Note: resistor’s value should be
indicated in the control panel’s datasheet / instructions
manual.
• Connect the sounder line’s terminals (optional) to the relevant
connector and ensure you install the correct sounders R EOL resistor.
8
7
10
The conventional expander will power up and will be ready
for commissioning.
• Connect the power supply terminals (EN54-4 certified
power source is required).
• Connect the power supply’s monitoring inputs (optional).
• Screw the lid to the back box using the supplied plastic
screws and refit top and bottom front plastics that cover
screw housings.
• Put the QR code available in the box either on the system
map or on the dedicated pages at the end of conventional
expander manual.
GREEN LED
MAINS FAULT
PULL-UP TO 3V3 BATTERY FAULT
BATTERY
CHARGER FAULT
BATTERY O/C
ext. power (-)ext. power (+)
ZONE
LINE (+)
CIE
ZONE
LINE
ZONE
LINE (-)
LINE EOL (+)
ALARM
EOL (+)
ALARM
EOL (-)
LINE
REOL
ALARM
REOL
LINE EOL (-)
CIE
SOUNDERS
REOL
SOUNDER
LINE
SOUNDERS
LINE (+)
SOUNDERS
LINE (-)
SOUNDERS
EOL (+)
SOUNDERS
EOL (-)
TAU-CEM-01
HYFIRE TAURUS CONVENTIONAL EXPANDER MODULE
QUICK START GUIDE
Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP
T: +44 (0)1926 485282, E: info@hyfirewireless.co.uk, W: www.hyfirewireless.com
L50-MEC-1400 (Rev_P.2)

Other hyfire Extender manuals

hyfire Taurus TAU-CEMD-01 User manual

hyfire

hyfire Taurus TAU-CEMD-01 User manual

hyfire HFW-CEM-02 User manual

hyfire

hyfire HFW-CEM-02 User manual

hyfire TAURUS TAU-EXM-01 User manual

hyfire

hyfire TAURUS TAU-EXM-01 User manual

Popular Extender manuals by other brands

HDCVT TECHNOLOGY HDC-EDB50C user manual

HDCVT TECHNOLOGY

HDCVT TECHNOLOGY HDC-EDB50C user manual

EtherWAN ED3575 installation guide

EtherWAN

EtherWAN ED3575 installation guide

Valens EVX6-USB-KT-POE Setup guide

Valens

Valens EVX6-USB-KT-POE Setup guide

Linsar LSSTB user manual

Linsar

Linsar LSSTB user manual

Safety 1st air protect instructions

Safety 1st

Safety 1st air protect instructions

Patton CopperLink 1314R quick start guide

Patton

Patton CopperLink 1314R quick start guide

Orei UHD-EX230-KVM user manual

Orei

Orei UHD-EX230-KVM user manual

4KDVB HD-F01-TX user manual

4KDVB

4KDVB HD-F01-TX user manual

Ebode IR Link Pro Guide

Ebode

Ebode IR Link Pro Guide

KONDATOR Docky - 4 user manual

KONDATOR

KONDATOR Docky - 4 user manual

Techly IDATA EXTIP-373V user manual

Techly

Techly IDATA EXTIP-373V user manual

Gefen COMPAUD-141 user manual

Gefen

Gefen COMPAUD-141 user manual

CTC Union TEX-100 user manual

CTC Union

CTC Union TEX-100 user manual

PX DSC-IR100A user manual

PX

PX DSC-IR100A user manual

Icron USB Rover 200 user guide

Icron

Icron USB Rover 200 user guide

Toa WE-2 manual

Toa

Toa WE-2 manual

AMG Active AMG1212 instruction manual

AMG

AMG Active AMG1212 instruction manual

SC&T IP02 manual

SC&T

SC&T IP02 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.