COUNTDOWN TIMER MODE
Maximum setting time: 9 Hour, 59 Minutes and 59 seconds.
BATTERY LIFE INDICATOR
Battery life indicator (upper left corner) on the display will e on when the attery
needs to e replaced. Lithium attery CR 2032 or equivalent is used.
IF THERE IS ANY IRREGULAR SEGMENTS OR MALFUNCTIONS, PLEASE HOLD
DOWN THE 4 BUTTONS TO RESET THE STOPWATCH
<TIMER>
DISPLAY
<STOPWATCH>
DISPLAY
COUNTDOWN TIMER MODE
Maximum setting time: 9 Hour, 59 Minutes and 59 seconds. If started from zero,
counting time is 10 hours.
Upper left corner shows the repeat counter.
Middle Row shows the setting time. Hour, Minute
and Second (Initial value: 0:00’00”0)
“TMR▼” icon will display.
Bottom Row shows the running time: Hour, Minute
and Second (Initial value: 0:00’00”0
1. Press “A”: Start/Stop the Timer
2. Press “B”: If Timer is stopped: reload the Timer Run value to Timer Set
value. If timer is running: No function.
3. Press “C”: Hold for 2 seconds will enter into Timer setting Mode
4. Press “D”: Change to next mode.
SETTING MODE
(Repeat counter will clear to zero when enter this setting mode)
Hour digits will e set first
After enter the setting mode:
1. Press “B” to select the digits (flashing ) to e adjusted in the following order.
2. Press “ A “to set the flashing digits. *The digits move quickly if “A” is kept press
over 2 seconds.
3. After all the adjustment are completed, press “C”.
Notes:
When the Timer Alarm is on, it will last for 5 seconds:
After exit setting, the Lower Row will load the set value of the Middle Row.
STOPWATCH MODE
The Stopwatch can measure up to 10 hours in hours, minutes, seconds and 1/100
seconds.
Press “D” to enter this mode
After enter this mode, display will
show “STW” icon.
● Before using the stopwatch, e sure to reset the digits to “0:000000 When the
stopwatch is stopped, press “B”.
When the stopwatch is counting, press “A” to stop the measurement and then
press “B”.
● “Split time” refers to an elapsed time required to cover a distance from the start
to a given point.
“Lap time” refers to an elapsed time required to cover a given section of the
whole distance.
1. Standard Measurement
2. Accumulated Elapsed Time Measurement
3. Split Time/Lap Time measurement
HOW TO USE THE MEMORY FUNCTION.
The stopwatch can store up to the first 8 split / lap times and the total elapsed time.
They are automatically entered into the memory. In additional, the fastest lap, and the
slowest lap can also e recalled
TRACEABLE
®
DUAL-DISPLAY DIGITAL STOPWATCH INSTRUCTIONS
● With each press of “C”, the time stored is recalled. The time can e recalled
successively e keeping the utton pressed.
● To stop the recall of the stored data, press “A”, “B” or “D”. The measurements
when the stopwatch was stopped will e shown. Then press “B” to reset the
digits to “00”.
● The time stored in the memory can e recalled even while the stopwatch is
measuring.
WITH EACH PRESS OF C”
When the stopwatch is stopped Fastest Lap, Slowest Lap, after that.
Split time and lap time are recalled starting with
the first ones.
When the stopwatch is running Fastest Lap, Slowest Lap, after that, Split time
and lap time are recalled starting with the last
ones.
Notes:
1. To measure the lap time and split time while the stored data is recalled, operate
the uttons as follows. Press “B” to measure new lap time and split time. Press
“A” to stop or start the measurement.
2. When the memory is full, “split / lap num er” flash, extra split / lap times will not
store into memory ut the memory counter will still show extra split/lap times.
The fastest, slowest and average laps will not store into the memory.
Warranty, Service, or Recalibration
For warranty, service, or recali ration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714
Fax 281-482-9448
E- ail sales@control3.co
www.control3.co
Control Co pany is ISO 9001 Quality-Certified by
DNV and ISO 17025 accredited as a Calibration
Laboratory by A2LA.
Control Company Cat. No. 92-1034-00 Rev. 0 051508
Tracea le
®
is a registered trademark of
Control Company
© 2008 Control Company

Other manuals for TRACEABLE

5

Other Control Company Watch manuals

Control Company Traceable 300-Memory User manual

Control Company

Control Company Traceable 300-Memory User manual

Popular Watch manuals by other brands

Lotus Chronograph Calendar ILMOS10 instruction manual

Lotus

Lotus Chronograph Calendar ILMOS10 instruction manual

Piaget 1200D1 Instructions for use

Piaget

Piaget 1200D1 Instructions for use

Nordval SW102 manual

Nordval

Nordval SW102 manual

Samsung SM-R820 Golf Edition user manual

Samsung

Samsung SM-R820 Golf Edition user manual

Uniform Wares M42 User instructions

Uniform Wares

Uniform Wares M42 User instructions

G-Tab W101hero Operation manual

G-Tab

G-Tab W101hero Operation manual

Coheretech UW80 user guide

Coheretech

Coheretech UW80 user guide

Rodania RONDA CAL. 7003.L User instructions

Rodania

Rodania RONDA CAL. 7003.L User instructions

Citizen E210 Abbreviated Instruction

Citizen

Citizen E210 Abbreviated Instruction

Auriol 2-LD3975-5 Usage and safety instructions

Auriol

Auriol 2-LD3975-5 Usage and safety instructions

Samsung Galaxy Smartwatch manual

Samsung

Samsung Galaxy Smartwatch manual

LG G Watch R LG-W110 user guide

LG

LG G Watch R LG-W110 user guide

LORUS V621 quick guide

LORUS

LORUS V621 quick guide

Casio QW-389 manual

Casio

Casio QW-389 manual

ROD iCONIC GRANDE DATE user manual

ROD

ROD iCONIC GRANDE DATE user manual

Garmin FENIX 6 PRO Series owner's manual

Garmin

Garmin FENIX 6 PRO Series owner's manual

Seiko SRX011P1 quick start guide

Seiko

Seiko SRX011P1 quick start guide

Mido GMT Calibre 80 user manual

Mido

Mido GMT Calibre 80 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.