manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Coolon
  6. •
  7. Floodlight
  8. •
  9. Coolon BUTCH User manual

Coolon BUTCH User manual

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Butch LED Floodlight 75W / 150W
Voltage In
200 – 440VAC 50/60Hz
Power
85W / 160W
IP/IK Rating
IP66 / IK09
Operating Temperature
-20 to +50°C
The U-Bolt Pole Mounting Clamp Kit is specifically
designed for mounting products with a flat mounting
surface on a variety of circular poles that are widely
used in the industry.
For more information visit:
https://www.coolon.com.au/dl/ind-acc-u-bolt-pmc
Electrical Characteristics
Voltage In
200 – 440VAC 50/60Hz
Power
250W
IP/IK Rating
IP66 / IK09
Operating Temperature
-20 to +50°C
Electrical Characteristics
Butch LED Floodlight 240W
Bracket Footprint U-Bolt Pole Mounting Clamp Kit (Optional)
WIRING DIAGRAM
AC INPUT
M20 Cable Gland
Wire diameter
Ø7–10mm
AC OUTPUT
M20 Cable Gland
Wire diameter
Ø7–10mm
N E L
NNeutral
Earth
LLine (Active)
Page 1 / 2BUTCH INDUSTRIAL LED MANUAL EDITION 1.2
Page 1 / 2[email protected] • aus. 1300 287 533 • intl. +613 8681 3633 • www.coolon.com.au
As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field.
The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information.
Product must be installed by a suitably qualified person. All documentation is subject to change without notice.
www.coolon.com.au
385mm 62mm187mm
413mm 446mm
385mm 62mm
187mm
304mm 340mm
Ø17mmØ13mm Ø13mm
60mm
102mm
195mm
275mm
385mm
Excessive and prolonged obstruction of the
optical surface may result in associated
damage which is not covered by warranty.
ATTENTION
The mounting bracket allows for a flat surface and pole mounting.
When mounting to a flat surface, secure using a minimum of
2x M10 bolts. When mounting to a pole use a
U-Bolt Pole Mounting Clamp Kit.
MOUNTING
NOTE: In order to adjust bracket angle the bracket armlock
teeth must be separated completely from the housing.
6mm
Butch LED Floodlight 75W / 150W Butch LED Floodlight 240W
120°
120°
0°
Mounting to comply with Dark Sky (DS43)
When mounting to comply
with Dark Sky (DS43)
B L F-15 0 - W W T-T4 - M P
or B L F -24 0 - W W T-T4 - M P
ensure the luminaire is
mounted horizontally
Page 2 / 2[email protected] • aus. 1300 287 533 • intl. +613 8681 3633 • www.coolon.com.au
As a matter of continual improvement, the requirements and recommendations in our manuals evolve to reflect new industry requirements and the latest feedback from the field.
The Coolon team is working hard to ensure optimal product operation and the safety of all users, please check our website periodically to ensure you are up to date with the latest information.
Product must be installed by a suitably qualified person. All documentation is subject to change without notice.
www.coolon.com.au
IMPORTANT
• Read through this manual before installation
• Handle the product with care
• Class I products must be grounded
• The product must be installed by a suitably qualified person
• Do not stare at operating lamp, may be harmful to the eyes
• Turn OFF the power before installation and maintenance
• Make sure the product is securely installed
• The housing might become hot after operation
• Keep optical face clean
Primary use: commercial and industrial applications.
Page 2 / 2BUTCH INDUSTRIAL LED MANUAL EDITION 1.2
186°
156°
0°