Coopers 9014 User manual

Please read carefully before use and retain for future reference.
PARTS
1. Handle
2. Float lock
3. Float switch
4. Intake cage
5. Hose fitting
WARNING
•N T for use with petrol, greases, salt water or other
corrosive liquids.
•Do N T use in freezing conditions.
•Do N T submerge into liquid hotter than 35°C
•Do N T operate dry.
•Ensure the work area is clear before use. Keep away
from children.
•To avoid the risk of damage to the cable or to the
waterproof seal, do N T pull on the power cord when disconnecting the pump.
•Never carry the pump by the cable.
•This pump is not a toy. Do N T allow children to play with the pump.
•The pump must be supplied through a residual current device (RCD) having a rated residual operating
current not exceeding 30mA
•Ensure that the voltage supply matches the voltage indicated on the pump (230V~50Hz)
•Do N T use if the power cord or the waterproof seal around the power cord is damaged.
•For domestic use only.
•The pump is not designed for continuous use. Allow at least a 10 minute break for after each hour of
use.
•Always submerge the pump before starting the pump.
•Clear water use only. Do N T use in dirty water.
•Ensure there are no foreign bodies in the water of a greater size than 5mm diameter. Larger foreign
bodies will block the pipes and cause damage to the pump.
•To prevent the pump from running empty, keep upright and ensure that the float switch is not
obstructed or in a position where it can become jammed in mud.
•Do N T use if there are people in the water.
•Do N T use for drinking water. Risk of contamination from lubricants.
•Always unplug after use and before cleaning.
HOW TO CONNECT THE HOSE
•The pump is fitted with a connector that is tapered and can be cut so as to fit 3 different sizes of hose:
1. Hoses of 13mm/15mm/19mm diameter:
•Cut the top section of the connector off at position A.
•crew a 25.4mm tap adaptor onto the end of the connector. Connect appropriate size hose
quick connector onto the tap adaptor, insert the hose and tighten.
2. Hoses of 25mm diameter:
•No cutting required.
•Attach 25mm diameter hose onto the connector and secure using a hose clamp.
3. Hoses of 32mm diameter:
•Cut off the top 2 sections of the connector at position B.
•Attach 32mm diameter hose onto the connector and secure with a hose clamp.
5
250W Clear Water Buffalo Pump 9014

Note: Hose,
tap adaptor
hose quick
connector
and hose
clamps are
not provided
but are
widely
available.
HOW TO USE
•The pump is designed for domestic use only, to be used in sumps or places where there is a risk of
flooding.
•Before use, check for a suitable and safe place to release the displaced water. Please check local
authority regulations. Do not pump water onto a road or pavement.
•Ensure there is sufficient space around the float switch.
•The float switch automatically starts the pump when the water level exceeds the cut-in height and
begins to pump water out. nce the water level falls below the cut-in height, the float switch will
turn the pump off.
•Stand the pump on a flat, firm surface or lower using a rope attached to the handle.
•Plug power cord into mains socket.
•Push the float switch cable into the float switch lock, ensuring the length of cable is not too long or
too short to allow the float switch to turn on and off properly.
•A shorter length of cable will mean a lower cut-in height and a higher cut-out height.
•The cable length between the float switch lock and float switch must be at least 10cm at all times.
BEFORE FIRST USE/TROUBLESHOOTING
•Check the pump and power cord for any damage.
•Check operation in a barrel or other suitable vessel filled with water. Immerse the pump into water
and then lift slightly and put down the float switch. The pump should start and stop.
•The float switch should not touch the bottom before the pump cuts off, otherwise there will be a risk
of running empty.
TECHNICHAL INFORMATION
Voltage: 230V~50Hz
Power: 250 W
Max. flow: 7m3/h
Max. delivery height: 7m
Max. operating depth: 8m
Max foreign bodies size: ø5mm
Height of the switch-on point automatically: 50cm
Height of the switch-off point automatically:5cm
CARE & CLEANING
•Unplug the power cord from the mains
before cleaning.
•Clean plastic parts with a soft, damp
cloth.
•Do N T use detergents, solvents or
abrasives.
•Store in a frost-free environment.
IPX8
PACKAGING
•Dispose of packaging at your local recycling centre.
•Dispose of paper and carton separately from plastic bags at your local recycling centre.
•Dispose of item at the end of its lifespan at your local authorised household waste recycling centre.
5

5
Please read carefully before use and retain for future reference.
PARTS
1. Handle
2. Float lock
3. Float switch
4. Intake cage
5. Hose fitting
WARNING
•This um should NOT be installed in swimming ools.
•NOT for use with etrol, greases, salt water or other
corrosive liquids.
•Do NOT use in freezing conditions.
•Do NOT submerge into liquid hotter than 35°C
•Do NOT o erate dry.
•Ensure the work area is clear before use. Kee away from
children.
•To avoid the risk of damage to the cable or to the
water roof seal, do NOT ull on the ower cord when
disconnecting the um .
•Never carry the um by the cable.
•This um is not a toy. Do NOT allow children to lay with
the um .
•The pump must be supplied through a residual current device (RCD) having a rated residual operating
current not exceeding 30mA
•Ensure that the voltage su ly matches the voltage indicated on the um (230V~50Hz)
•Do NOT use if the ower cord or the water roof seal around the ower cord is damaged.
•For domestic use only.
•The um is not designed for continuous use. Allow at least a 10 minute break for after each hour of
use.
•Always submerge the um before starting the um .
•Ensure there are no foreign bodies in the water of a greater size than 25mm diameter. Larger foreign
bodies will block the i es and cause damage to the um .
•To revent the um from running em ty, kee u right and ensure that the float switch is not
obstructed or in a osition where it can become jammed in mud.
•Do NOT use if there are eo le in the water.
•Do NOT use for drinking water. Risk of contamination from lubricants.
•Always un lug after use and before cleaning.
HOW TO CONNECT THE HOSE
•The um is fitted with a connector that is ta ered and can be cut so as to fit 3 different sizes of hose:
1. Hoses of 13mm/15mm/19mm diameter:
•Cut the top section of the connector off at position A.
•crew a 25.4mm tap adaptor onto the end of the connector. Connect appropriate size hose
quick connector onto the tap adaptor, insert the hose and tighten.
2. Hoses of 25mm diameter:
•No cutting required.
•Attach 25mm diameter hose onto the connector and secure using a hose clamp.
3. Hoses of 32mm diameter:
•Cut off the top 2 sections of the connector at position B.
•Attach 32mm diameter hose onto the connector and secure with a hose clamp.
400W Dirty Water Buffalo Pum
9015

Note: Hose,
ta ada tor
hose quick
connector
and hose
clam s are
not rovided
but are
widely
available.
HOW TO USE
•The um is designed for domestic use only, to be used in sum s or laces where there is a risk of
flooding.
•Before use, check for a suitable and safe lace to release the dis laced water. Please check local
authority regulations. Do not um water onto a road or avement.
•Ensure there is sufficient s ace around the float switch.
•The float switch automatically starts the um when the water level exceeds the cut-in height and
begins to um water out. Once the water level falls below the cut-in height, the float switch will
turn the um off.
•Stand the um on a flat, firm surface or lower using a ro e attached to the handle.
•Plug ower cord into mains socket.
•Push the float switch cable into the float switch lock, ensuring the length of cable is not too long or
too short to allow the float switch to turn on and off ro erly.
•A shorter length of cable will mean a lower cut-in height and a higher cut-out height.
•The cable length between the float switch lock and float switch must be at least 10cm at all times.
BEFORE FIRST USE/TROUBLESHOOTING
•Check the um and ower cord for any damage.
•Check o eration in a barrel or other suitable vessel filled with water. Immerse the um into water
and then lift slightly and ut down the float switch. The um should start and sto .
•The float switch should not touch the bottom before the um cuts off, otherwise there will be a risk
of running em ty.
TECHNICHAL INFORMATION
Voltage: 230V~50Hz
Power: 400 W
Max. flow: 10m3/h
Max. delivery height: 6.5m
Max. o erating de th: 8m
Max foreign bodies size: ø25mm
Height of the switch-on oint automatically: 50cm
Height of the switch-off oint automatically:5cm
CARE & CLEANING
•Un lug the ower cord from the mains
before cleaning.
•Clean lastic arts with a soft, dam
cloth.
•Do NOT use detergents, solvents or
abrasives.
•Store in a frost-free environment.
IPX8
PACKAGING
•Dis ose of ackaging at your local recycling centre.
•Dis ose of a er and carton se arately from lastic bags at your local recycling centre.
•Dis ose of item at the end of its lifes an at your local authorised household waste recycling centre.
5
Table of contents
Popular Water Pump manuals by other brands

swiftech
swiftech MCP600 user guide

Graco
Graco ChemSafe 1590 Instructions - parts

BUSCH
BUSCH R5 Aqua Instruction manual supplement

AMT
AMT 3160-99 Specifications information and repair parts manual

Gardena
Gardena 3000/3 Jet operating instructions

Ariston
Ariston SOLARcomfort Instructions for installation and servicing

Wilo
Wilo Stratos GIGA2.0-I Installation and operating instructions

EINHELL
EINHELL GE-AW 9041 E Original operating instructions

IPM
IPM IP02 Series OPERATIONING MANUAL WITH PARTS IDENTIFICATION

Seliger
Seliger 40340 operating instructions

Kessel
Kessel KTP 300 Installation, operation and maintenance manual

EINHELL
EINHELL GE-PP 5555 RB-A Original operating instructions