1
1.Attentiononhandling
2.Partnumberdesignation
3.Instructionforuse
ThankyouforpurchasingNIDECCOPAL
ELECTRONICSCORP.product.
Inordertousetheproductcorrectlyandmost
appropriately,pleasecompletelyreadthismanual
beforeuseandkeepitforfuturereference.
PressureTransducers
withAmp.
INSTRUCTIONMANUALVer.1.1
PA-838-D
series
…
Nishi-ShinjukuKimurayaBidg.,7-5-25
Nishi-ShinjukuShinjuku-kuTokyo160-0023,Japan
Phone:(03)3364-7055FAX:(03)3364-7078
Formoredetailsinformationpleaseaskforthenearest
distributororthefollowingsalescenter.
NIDECCOPALELECTRONICSCORPRATION
PA−838−□□□D−□□
Fitting Blank:Rc1/4
    F2:Flarefitting(7/16-20UNF)
Ratedpressurerange 101:10kPa
          501:50kPa
          102:100kPa
Thiscautionmarkdescribeswhenthereisapossibilitythatusermaysufferfromdamageorphysicaldamage
mayoccuriftheproductisusedimproperly.
・Theapplicationmediumofthisproductiscorrosivegases/liquidscompatiblewithSUS304.
・Neverinsertanyforeignmatters,likewireorneedle,intothepressureporthole.Itcausesthebreakdown.
・Donotapplyexceedingthemaximumpressureasshowninthespecification.Theexcessivepressuremayaffectthesensorcharacteristicsand
maymakeaccuratemeasurementimpossible.
・Donotgiveunnecessaryforcetothemainbodyandcablewheninstallingtheproduct.Theexcessivepressuremayaffectthesensorcharacteris-
ticsandmaymakeaccuratemeasurementimpossible.
・Besuretoconnecttheoutputterminalscorrectly.Wrongconnectionwillcausedamageoftheinternalelectriccircuit.
・Pleasesupplyastablepowersourceanddonotexceedthespecifiedsupplyvoltage.Itwillcausedamageoftheelectriccircuit.
・Pleasemakeahigh-pressuresidethesameasthepipingconditiononalow-pressuresidewhenyoulaypipes.(Diameterandlengthofthe
tubeetc.)Whenatransitionalpressurefluctuationiscaused,itcausesthebreakdowniftheconditionisnotthesame.
・Thisproductisdustproofanddripproof(toIP65ofIECstandards)andisnotsuitableforuseinenvironmentsrequiringhigherstandards.

・Pleasesupplyastablepowersource.
・Placethewiringasfarawayaspossiblefromthepowerlinescarryinglargepower.Theoutputbecomesunstablebecauseofthenoiseetc.
Pleaseconfirmthepartnumberoftheproductyoupurchased.





・F2typeincludes2piecesofflarefittinginthesamepackage.
Ratedpressure,maximumpressure,andlinepressurearedecidedtothisproductin
eachpressurerange.Becarefulwhenyouusethisproduct.

Ratedpressure:Pressurevalueinwhichspecificationofdifferentialpressuresensorisguaranteed.
        (Onthespecification,itisprovidedbylowpressuresideisequalto0kPa.)
Maximumpressure:Maximumpressurevaluethatcanbeappliedonlytooneofhighpressuresideorlowpressureside.
Linepressure:Maximumpressurevalueinwhichproductisnotdamagedwhenequalpressuretohighpressuresideandlowpressuresideisapplied.
・Piping
 Thefitting forPA-838-D isRc1/4. Usean appropriatepipe toits fitting.To securethe fitting,
holdtheflange-partwhensecuringthefitting.ThetighteningtorqueofR1/4thatourcompany
recommendsisfrom12N・mto14N・m

・Valve
 Inordertopreventfromapplyingpressureexceedingthespecification,pipingisdonewiththe
followingvalve.(Pleaserefertoleftfigure.)
 Followtheprocedurebelowwhenapplyingpressure:
(Ⅰ)ValveA,BmustbeclosedandvalveCmustbeopenwhenpiping.
(Ⅱ)Slowly,openvalveA.
(Ⅲ)Whenthepressureisstabilized,closevalveC
(Ⅳ)Slowly,openvalveB

・Air-bleeding
 Residual air in the piping can result inaccurate measurement and causes difference in high-
pressuresideandlow-pressuresidewhichcouldresultindevelopingexcessivepressure.Please
Air-bleedthesensorafterinstallation.DuringAir-bleed,donotcompletelyremovetheair-bleed
screw.Pleasebeawarethataccuratemeasurementcannotbedonewithoutthestopballbelow
theair-bleedscrew.Pleasetightentheair-bleedscrewfromtheplacewherethescrewstoppedby
1/8rotations.(standardtighteningtorque1.5N・m)

・Wiring
 WiretheredwiretoDC24V(+),andwhitewirethoughloadresistance(below500ohm),and
toDC.COM.Incasethereisapossibilityofapplyingpressureovertheratedpressure,setthe
load resistance to 500ohm.  In case the pressure exceeds rated pressure, the 500ohm load
resistancelimitsthepowercurrenttoabout28mA,thuspreventfromcircuitdamagecausedby
overloadedpowercurrent.
2
4.Installation
5.Specifications
Item
Pressurerange
Pressurereference
Ratedpressurerange
MaximumPressure(Singleside)
Linepressure(Bothside)
Operatingtemp.range
Compensatedtemp.range
Operatinghumidity
Storagetemp.
Pressuremedium
Weight
Enclosedliquid
Protectivestructure
Supplyvoltage


Linearity/Hysteresis


Response
Gravitationaleffect
Specification

Differential


2MPa
−20〜70℃
0〜50℃
35〜85%RH
−20〜70℃
Corrosivegases/liquidscompatiblewithSUS304.
About410g,about500gforF2
Siliconeoil
IP65
24V±10%DC
4±0.2mA
16±0.2mA
±0.5%FS


Approx.2ms.
±3%FSmax.

101

10kPa
200kPa













±0.10%FS
±0.10%FS

±5%FSmax.

501

50kPa
300kPa














102

100kPa
500kPa
















±1%FSmax.
Outputcurrent
Thermalerror
(0to50℃)
Zero
Span
Zero
Span
±0.05%FS
±0.05%FS
GGGGGGGGGGGGG

Popular Transducer manuals by other brands

Humminbird XP 9 20 T quick start guide

Humminbird

Humminbird XP 9 20 T quick start guide

HBM C16A Series operating manual

HBM

HBM C16A Series operating manual

Humminbird XTH 9 20 P manual

Humminbird

Humminbird XTH 9 20 P manual

gtm MKA Series operating manual

gtm

gtm MKA Series operating manual

Veris PX3 Series installation guide

Veris

Veris PX3 Series installation guide

Kanomax 6333 user manual

Kanomax

Kanomax 6333 user manual

Swagelok S user manual

Swagelok

Swagelok S user manual

Omega RH62 Series manual

Omega

Omega RH62 Series manual

Mastech CT300 Operator's manual

Mastech

Mastech CT300 Operator's manual

Nexus Compass 35 Installation and operation manual

Nexus

Nexus Compass 35 Installation and operation manual

Lowrance StructureScan 3D installation manual

Lowrance

Lowrance StructureScan 3D installation manual

Garmin GT15M-IH installation instructions

Garmin

Garmin GT15M-IH installation instructions

NK TECHNOLOGIES VTU Series instructions

NK TECHNOLOGIES

NK TECHNOLOGIES VTU Series instructions

PICO WPS600C user guide

PICO

PICO WPS600C user guide

ZIEHL STWA1FH operating manual

ZIEHL

ZIEHL STWA1FH operating manual

Setra Systems 526 installation guide

Setra Systems

Setra Systems 526 installation guide

aci ACCESS series Installation & operation instructions

aci

aci ACCESS series Installation & operation instructions

Simrad 38-200 COMBI C -  REV D installation manual

Simrad

Simrad 38-200 COMBI C - REV D installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.