1
1.Attentiononhandling
2.Partnumberdesignation
3.Instructionforuse
ThankyouforpurchasingNIDECCOPAL
ELECTRONICSCORP.product.
Inordertousetheproductcorrectlyandmost
appropriately,pleasecompletelyreadthismanual
beforeuseandkeepitforfuturereference.
PressureTransducers
withAmp.
INSTRUCTIONMANUALVer.1.1
PA-838-D
series
…
Nishi-ShinjukuKimurayaBidg.,7-5-25
Nishi-ShinjukuShinjuku-kuTokyo160-0023,Japan
Phone:(03)3364-7055FAX:(03)3364-7078
Formoredetailsinformationpleaseaskforthenearest
distributororthefollowingsalescenter.
NIDECCOPALELECTRONICSCORPRATION
PA−838−□□□D−□□
Fitting Blank:Rc1/4
    F2:Flarefitting(7/16-20UNF)
Ratedpressurerange 101:10kPa
          501:50kPa
          102:100kPa
Thiscautionmarkdescribeswhenthereisapossibilitythatusermaysufferfromdamageorphysicaldamage
mayoccuriftheproductisusedimproperly.
・Theapplicationmediumofthisproductiscorrosivegases/liquidscompatiblewithSUS304.
・Neverinsertanyforeignmatters,likewireorneedle,intothepressureporthole.Itcausesthebreakdown.
・Donotapplyexceedingthemaximumpressureasshowninthespecification.Theexcessivepressuremayaffectthesensorcharacteristicsand
maymakeaccuratemeasurementimpossible.
・Donotgiveunnecessaryforcetothemainbodyandcablewheninstallingtheproduct.Theexcessivepressuremayaffectthesensorcharacteris-
ticsandmaymakeaccuratemeasurementimpossible.
・Besuretoconnecttheoutputterminalscorrectly.Wrongconnectionwillcausedamageoftheinternalelectriccircuit.
・Pleasesupplyastablepowersourceanddonotexceedthespecifiedsupplyvoltage.Itwillcausedamageoftheelectriccircuit.
・Pleasemakeahigh-pressuresidethesameasthepipingconditiononalow-pressuresidewhenyoulaypipes.(Diameterandlengthofthe
tubeetc.)Whenatransitionalpressurefluctuationiscaused,itcausesthebreakdowniftheconditionisnotthesame.
・Thisproductisdustproofanddripproof(toIP65ofIECstandards)andisnotsuitableforuseinenvironmentsrequiringhigherstandards.

・Pleasesupplyastablepowersource.
・Placethewiringasfarawayaspossiblefromthepowerlinescarryinglargepower.Theoutputbecomesunstablebecauseofthenoiseetc.
Pleaseconfirmthepartnumberoftheproductyoupurchased.





・F2typeincludes2piecesofflarefittinginthesamepackage.
Ratedpressure,maximumpressure,andlinepressurearedecidedtothisproductin
eachpressurerange.Becarefulwhenyouusethisproduct.

Ratedpressure:Pressurevalueinwhichspecificationofdifferentialpressuresensorisguaranteed.
        (Onthespecification,itisprovidedbylowpressuresideisequalto0kPa.)
Maximumpressure:Maximumpressurevaluethatcanbeappliedonlytooneofhighpressuresideorlowpressureside.
Linepressure:Maximumpressurevalueinwhichproductisnotdamagedwhenequalpressuretohighpressuresideandlowpressuresideisapplied.
・Piping
 Thefitting forPA-838-D isRc1/4. Usean appropriatepipe toits fitting.To securethe fitting,
holdtheflange-partwhensecuringthefitting.ThetighteningtorqueofR1/4thatourcompany
recommendsisfrom12N・mto14N・m

・Valve
 Inordertopreventfromapplyingpressureexceedingthespecification,pipingisdonewiththe
followingvalve.(Pleaserefertoleftfigure.)
 Followtheprocedurebelowwhenapplyingpressure:
(Ⅰ)ValveA,BmustbeclosedandvalveCmustbeopenwhenpiping.
(Ⅱ)Slowly,openvalveA.
(Ⅲ)Whenthepressureisstabilized,closevalveC
(Ⅳ)Slowly,openvalveB

・Air-bleeding
 Residual air in the piping can result inaccurate measurement and causes difference in high-
pressuresideandlow-pressuresidewhichcouldresultindevelopingexcessivepressure.Please
Air-bleedthesensorafterinstallation.DuringAir-bleed,donotcompletelyremovetheair-bleed
screw.Pleasebeawarethataccuratemeasurementcannotbedonewithoutthestopballbelow
theair-bleedscrew.Pleasetightentheair-bleedscrewfromtheplacewherethescrewstoppedby
1/8rotations.(standardtighteningtorque1.5N・m)

・Wiring
 WiretheredwiretoDC24V(+),andwhitewirethoughloadresistance(below500ohm),and
toDC.COM.Incasethereisapossibilityofapplyingpressureovertheratedpressure,setthe
load resistance to 500ohm.  In case the pressure exceeds rated pressure, the 500ohm load
resistancelimitsthepowercurrenttoabout28mA,thuspreventfromcircuitdamagecausedby
overloadedpowercurrent.
2
4.Installation
5.Specifications
Item
Pressurerange
Pressurereference
Ratedpressurerange
MaximumPressure(Singleside)
Linepressure(Bothside)
Operatingtemp.range
Compensatedtemp.range
Operatinghumidity
Storagetemp.
Pressuremedium
Weight
Enclosedliquid
Protectivestructure
Supplyvoltage


Linearity/Hysteresis


Response
Gravitationaleffect
Specification

Differential


2MPa
−20〜70℃
0〜50℃
35〜85%RH
−20〜70℃
Corrosivegases/liquidscompatiblewithSUS304.
About410g,about500gforF2
Siliconeoil
IP65
24V±10%DC
4±0.2mA
16±0.2mA
±0.5%FS


Approx.2ms.
±3%FSmax.

101

10kPa
200kPa













±0.10%FS
±0.10%FS

±5%FSmax.

501

50kPa
300kPa














102

100kPa
500kPa
















±1%FSmax.
Outputcurrent
Thermalerror
(0to50℃)
Zero
Span
Zero
Span
±0.05%FS
±0.05%FS
GGGGGGGGGGGGG

Popular Transducer manuals by other brands

Airmar CM599LH Owner's guide and installation instructions

Airmar

Airmar CM599LH Owner's guide and installation instructions

Thyracont VSM77D operating instructions

Thyracont

Thyracont VSM77D operating instructions

PCI DPT-4001 Operation & maintenance manual

PCI

PCI DPT-4001 Operation & maintenance manual

HP 5501A Operating and service manual

HP

HP 5501A Operating and service manual

Lowrance StructureScan 3D installation manual

Lowrance

Lowrance StructureScan 3D installation manual

TILLQUIST LQT40F user manual

TILLQUIST

TILLQUIST LQT40F user manual

Oppermann Regelgeräte OPP-SENS M Series manual

Oppermann Regelgeräte

Oppermann Regelgeräte OPP-SENS M Series manual

HBM U93 operating instructions

HBM

HBM U93 operating instructions

Electro-Voice 920-8B Technical specifications

Electro-Voice

Electro-Voice 920-8B Technical specifications

S+S Regeltechnik PREMASGARD 1140 Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik PREMASGARD 1140 Operating Instructions, Mounting & Installation

S+S Regeltechnik THERMSGARD RGTM2 Series Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik THERMSGARD RGTM2 Series Operating Instructions, Mounting & Installation

HBM AED9301B user manual

HBM

HBM AED9301B user manual

B-K Medical 8848 user guide

B-K Medical

B-K Medical 8848 user guide

Simrad TRANSDUCER MOUNTING PROCEDURE - SCHEMA REV B manual

Simrad

Simrad TRANSDUCER MOUNTING PROCEDURE - SCHEMA REV B manual

F&F MB-GPS-1 manual

F&F

F&F MB-GPS-1 manual

Axxeron HESCH HE 5411 operating instructions

Axxeron

Axxeron HESCH HE 5411 operating instructions

SIAP+MICROS t012 TTS User manual and maintenance

SIAP+MICROS

SIAP+MICROS t012 TTS User manual and maintenance

Mianyang Weibo Electronic WBI417S91 user manual

Mianyang Weibo Electronic

Mianyang Weibo Electronic WBI417S91 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.