.Features .
Auto Detect Open Door
When the system is being ARMED, if any door having Magnetic Switch (Wired or Wireless) is open, the system will
alert the user with a intermittent Siren Sound. The same is true for all wired sensors.
During this time, if the Opened Sensor or the opened Wired Zone is closed, the system will get ARMED and the
intermittent Siren sound will stop.
The main Panel display in this case is explained under the heading “Display explanations” – sub heading “while
Arming the system”.
Always Armed Zones
Some sensors can be configured to work 24 Hours. Whether the system is ARMED or not, these sensors would
initiate Siren hooting and Telephone dialing.
For example, a heat detector can be placed near Generator so that whenever generator heats due to a fault, the
siren would alert the user & also inform on his Cell number.
For further details refer the heading “Wireless Sensor – Operating Mode” and “Wired Sensor – Operating Mode”
Auto ARM / DISARM
System can be programmed to ARM / DISARM at set time.
ARM Bypass
User has option to ARM all the Zones or selected Zones. This helps in ARMING the system while servants are
present in some part of the building. For further details refer the heading “ARM Bypass”
Auto Dialer (Dialing through GSM SIM during intrusion)
The system dials up to 6 Telephone numbers and plays siren sound (pre-recorded message-Optional), during
intrusion. After 10 secs of Siren Sound, it plays the message “Batt low, Wired Zone Open, Wireless Sensor
Number, etc”
Each Telephone number can be programmed to dial from 1 to 14 times.
For further details refer the headings ”Telephone Numbers Entry” + “Telephone Number Redial Times” +
“Telephone Number Display - ON / OFF”
Battery (Rechargeable) In-built Li rechargeable batteries for backup lasting up to 15 hours. Can be extended by
connecting optional BAS-PS (Power Supply with 12V 7AH Maintenance Free Battery).
Battery Low warning –of Main Unit
When the in-built Batteries of the Main Unit goes low & the SYSTEM is in ARMED condition, it will dial the pre-fed
Telephone number to inform the user with a Voice Message “Battery is Low”. It is possible to Listen-in and Disarm
the system through Telephone.
In case the system is DISARMED then display will show “Main Batt is low” & it will give a beep every 15 secs. In
this condition, the display back light keeps getting ON for 10 secs and then OFF for 10 secs.
Note: When Battery goes low and the system is ARMED, intrusion will not work.
Battery Low warning –of Wireless Magnetic / Vibration Sensors (MSW, VSW, VSW-T, PIRW, PIRW-T)
When the cell of any of the wireless Magnetic / Vibration Sensors goes low & the system is in ARMED condition,
it will dial the pre-fed Telephone number to inform the user with a Voice Message “Battery is Low + ID Number”.
The user can Disarm the system & can also Listen-in.
When a new Cell is restored in the Sensor, the system registers that the sensor is now operative.
When the cell of any of the wireless Magnetic / Vibration Sensors goes low & the system is in DISARMED
condition, the display gives a message and the display back light keeps getting ON for 10 secs and then OFF for
10 secs. During this condition, the system also gives a mild beep every 15 secs.
Note: However, SMS message is not to be relied upon and low battery LED indication on the sensor should be
checked periodically.
Capacity: Can connect to 50 Wireless Sensors
: Has 6 Wired zones & each Zone can connect to unlimited Wired Sensors
The system can work with up to 50 Wireless Sensors (including Wireless Remotes & Signal Repeaters) and any
number of Wired Sensors as long as the total resistance of the Sensors and the wires is less than 200 Ohms.
Electrical Lights ON during Intrusion (Optional)
Selected Light load (not exceeding 200Watts) can be connected to it which gets ON whenever there is an
intrusion.
Multilevel Passwords
The system has 1 Master & 5 User Passwords
Master Password can do all operations and programming as well. User level Passwords can ARM /
DISARM their own defined Sensors, check balance in SIM, check system details.
The History records would show which Password had ARMED / DISARMED the system.
Remote Monitoring –Whenever user wants or during Intrusion.
User can make a Telephone call from anywhere and perform the following:
ARM or DISARM the system.