Coriant 8600 User manual

8600 Smart Routers
8602 Smart Router FP7.0 Reference Manual
76.8670-40130A
04.05.2015

Document Information
Revision History
Document No. Date Description of Changes
76.8670-40130A 04.05.2015 VCCI Compliance for 8602 Smart Router added.
This revision of the manual documents the following network elements and the corresponding
feature packs or higher.
8602 Smart Router FP7.0
If you have a different feature pack of 8600 products, please refer to the relevant product document
program on the Tellabs and Coriant Portal by navigating to www.portal.tellabs.com > Product
Documentation & Software > Data Networking > 8600 Smart Routers > Technical Documentation.
© 2015 Coriant. All rights reserved.
This manual is protected by U.S. and international copyright laws, conventions and treaties. Your right to use this manual is
subject to limitations and restrictions imposed by applicable licenses and copyright laws. Unauthorized reproduction, modification,
distribution, display or other use of this manual may result in criminal and civil penalties.
The specifications and information regarding the products in this manual are subject to change without notice. All statements,
information, and recommendations in this manual are believed to be accurate but are presented without warranty of any kind,
express or implied. Users must take full responsibility for their application of any products.
Adobe®Reader®are registered trademarks of Adobe Systems Incorporated in the United States and/or other countries.
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
2

Document Information
Terms and Abbreviations
Term Explanation
ATM Asynchronous Transfer Mode
BGP Border Gateway Protocol
BFD Bidirectional Forwarding Detection
BMP Broadband Management Protocol. A communication protocol that is used between
8600 network elements and 8000 intelligent network manager.
CIR Controlled Introduction Ready
CLI Command Line Interface
CPU Central Processor Unit
DSCP DiffServ Code Point
EEC Ethernet Equipment Clock
EEPROM Electrically Erasable Programmable Read Only Memory
EMC Electromagnetic Compatibility
EMI Electromagnetic Interference
ESD Electrostatic Discharge
Fan One fan in a fan module
Fan Module A module consisting of two or more fans, the mechanics and possibly the control
electronics
FLASH Electrically erasable and programmable memory type
FP Feature Pack
FTP Foil Shielded Twisted Pair
GA General Availability
GNSS Global Navigation Satellite Systems
GPS Global Positioning System
IP Internet Protocol or Ingress Protection
IS-IS Intermediate System to Intermediate System (Interior Gateway Protocol)
ITU-T International Telecommunication Union - Telecom Standardization Sector
LAG Ethernet Link Aggregation
LAN Local Area Network
LDP Label DistributionProtocol
LED Light-Emitting Diode
LM Line Module
LSP Label SwitchedPath
LTE Long Term Evolution
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
3

Document Information
MAC Media Access Control Sublayer of Data Link Layer
MPLS Multiprotocol Label Switching
MTU Maximum Transfer/Transmission Unit
Multi-card
NE
Network element whose hw-inventory contains multiple slots. Refers to 8611 Smart
Router, 8615 Smart Router, 8630 Smart Router and 8660 Smart Router.
NE Network Element
NPU Network Processor Unit
OAM Operations, Administration and Maintenance
OCXO Oven Controlled Crystal Oscillator
OSPF Open Shortest Path First
PLL Phase Locked Loop
PPS Pulse-per-Second
PRI Primary Rate Interface
PWE3 Pseudowire Edge to Edge Emulation
QinQ Stacked VLAN
QoS Quality of Service
RAN Radio Access Network
RFC Request For Comments
RNC Radio Network Controller
RSVP-TE Resource Reservation Protocol – Traffic Engineering
RTC Real Time Clock
SDH Synchronous Digital Hierarchy
SEC Synchronous Equipment Clock
SFP Small Form-Factor Pluggable
Single-card
NE
Network element whose hw-inventory contains only one slot. Refers to 8602 Smart
Router, 8605 Smart Router, 8607 Smart Router, 8609 Smart Router, 8615 Smart
Router and 8620 Smart Router.
SNMP Simple Network Management Protocol
SONET Synchronous Optical Network
SR System Release
TDM Time Division Multiplexing
TE Traffic Engineering
ToS Type of Service
VCCV Virtual Circuit Connectivity Verification
VLAN Virtual LAN (Local Area Network)
VPN Virtual Private Network
WFQ Weighted Fair Queueing
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
4

Document Information
Compliance Statement
Hereby, Coriant Oy declares that this product is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC and Directive 2011/65/EU.
VCCI Compliance Statement
FCC Notification Statement
Federal Communications Commission (FCC) Rules require that you be notified of the following:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by Coriant Operations, Inc., in writing can void
the user's authority to operate the equipment.
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
5

Document Information
Industry Canada Notification Statement
Industry Canada interference-causing equipment regulations require that you be notified of the
following:
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
6

Table of Contents
Table of Contents
About This Manual ............................................................................................................ 9
Objectives....................................................................................................................................................................... 9
Audience......................................................................................................................................................................... 9
8600 Smart Routers Technical Documentation.............................................................................................................. 9
Document Conventions .................................................................................................................................................. 12
Documentation Feedback ............................................................................................................................................... 12
8600 Smart Routers Discontinued Products ..................................................................13
Safety Notes ...................................................................................................................... 14
Intended Purpose ............................................................................................................................................................ 14
Class 1 Laser Product..................................................................................................................................................... 14
Jewelry Removal ............................................................................................................................................................ 15
Installation and Maintenance ......................................................................................................................................... 15
Lightning Activity .......................................................................................................................................................... 17
1 Network Element Overview ........................................................................................18
1.1 Enclosure ............................................................................................................................................................. 18
1.1.1 Baseboard ............................................................................................................................................ 19
1.1.2 Product Variants................................................................................................................................... 19
1.1.3 Interfaces ............................................................................................................................................. 20
1.1.4 Cooling ................................................................................................................................................ 20
1.2 NE Powering........................................................................................................................................................ 20
1.3 NE Synchronization............................................................................................................................................. 21
2 Baseboard....................................................................................................................22
2.1 Overview ............................................................................................................................................................. 22
2.2 Main Features ...................................................................................................................................................... 22
2.3 Operation ............................................................................................................................................................. 22
2.3.1 CPU Block........................................................................................................................................... 24
2.3.2 NPU Block........................................................................................................................................... 25
2.3.3 Asynchronous Serial Interface............................................................................................................. 25
2.3.4 Power Supply....................................................................................................................................... 25
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
7

Table of Contents
2.3.5 Test Features ........................................................................................................................................ 25
2.4 Interfaces ............................................................................................................................................................. 25
2.4.1 8602-A Variant .................................................................................................................................... 25
2.4.2 8602-D Variant .................................................................................................................................... 26
2.5 Front Panel and Connectors................................................................................................................................. 26
2.5.1 Optical Ethernet Interface.................................................................................................................... 26
2.5.2 Electrical Ethernet Interface ................................................................................................................ 28
2.5.3 CLI Interface........................................................................................................................................ 29
2.5.4 Power Input Connector........................................................................................................................ 29
2.6 LEDs.................................................................................................................................................................... 30
2.6.1 NE Status LEDs................................................................................................................................... 30
2.6.2 Ethernet LEDs ..................................................................................................................................... 30
3 DC Power Supply ........................................................................................................32
3.1 Overview ............................................................................................................................................................. 32
3.2 Operation ............................................................................................................................................................. 32
3.3 Input Fault Detection........................................................................................................................................... 32
3.4 Technical Specifications ...................................................................................................................................... 32
3.5 DC Power Connection ......................................................................................................................................... 32
4 AC Power Supply ........................................................................................................34
4.1 Overview ............................................................................................................................................................. 34
4.2 Operation ............................................................................................................................................................. 34
4.3 Input Fault Detection........................................................................................................................................... 34
4.4 Technical Specifications ...................................................................................................................................... 34
4.5 AC Power Connection ......................................................................................................................................... 34
5 Technical Specifications.............................................................................................36
5.1 8602 Smart Router Technical Specifications....................................................................................................... 36
5.2 8602 Smart Router Baseboard Technical Specifications ..................................................................................... 40
5.2.1 Ethernet Specifications ........................................................................................................................ 40
5.2.2 Timing Block ....................................................................................................................................... 41
5.2.3 CLI Specifications ............................................................................................................................... 41
End of Life Treatment .......................................................................................................42
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
8

About This Manual
About This Manual
This chapter discusses the objectives and intended audience of this manual, 8600 Smart Routers
8602 Smart Router FP7.0 Reference Manual and consists of the following sections:
• Objectives
• Audience
• 8600 Smart Routers Technical Documentation
• Document Conventions
• Documentation Feedback
Objectives
The goal of this manual is to describe the network element features of the 8602 Smart Router.
Audience
This manual is intended for system specialists and personnel involved in network planning.
8600 Smart Routers Technical Documentation
The document numbering scheme consists of the document ID, indicated by numbers, and the
document revision, indicated by a letter. The references in the Related Documentation table below
are generic and include only the document ID. To make sure the references point to the latest
available document versions, please refer to the relevant product document program on the Tellabs
and Coriant Portal by navigating to www.portal.tellabs.com > Product Documentation & Software
> Data Networking > 8600 Smart Routers > Technical Documentation.
The table below reflects the customer document content planned for SR7.0 GA, and is subject to
change. Before General Availability of SR7.0, the configuration guides have the status of draft, and
they do not always describe the full functionality.
Document Title Description
8600 Smart Routers
ATMandTDMConfiguration Guide
(76.8600-50110)
Provides an overview of 8600 NEs PWE3 applications,
including types, Single-Segment and Multi-Segment; PWE3
Redundancy; ATM applications, including PWE3 tunnelling,
Traffic Management, Fault Management OAM, protection and
TDM applications as well as instructions on how to configure
them with CLI.
8600 Smart Routers
Boot and Mini-Applications
Embedded Software Release Notes
(76.8600-50108)
Provides information related to the boot and mini-applications
software of 8605 Smart Router, 8607 Smart Router, 8609
Smart Router, 8611 Smart Router, 8620 Smart Router, 8630
Smart Router and 8660 Smart Router as well as the installation
instructions.
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
9

About This Manual
Document Title Description
8600 Smart Routers
CLI Commands Manual
(76.8600-50117)
Provides commands available to configure, monitor and maintain
8600 system with CLI.
8600 Smart Routers
Embedded Software Release Notes
8600 Smart Routers SR7.0 Embedded Software Release Notes
(76.8670-50177) for the following products:
• 8602 Smart Router FP7.0
• 8609 Smart Router and 8611 Smart Router FP7.0
• 8615 Smart Router FP7.0
• 8630 Smart Router and 8660 Smart Router FP7.0
• 8665 Smart Router FP7.0
8600 Smart Routers
Equipment Management
Configuration Guide
(76.8600-50118)
Provides an overview of 8600 system HW inventory, software
management, equipment protection 1+1 (CDC and SCM) as well
as instructions on how to configure them with CLI.
8600 Smart Routers
Ethernet Configuration Guide (76.
8600-50133)
Provides an overview of 8600 system Ethernet applications,
including interfaces; Ethernet forwarding (MAC Switching,
Ethernet PWE3, IRB, VLAN, VPLS); Ethernet OAM; LAG;
ELP as well as instructions on how to configure them with CLI.
8600 Smart Routers Smart Routers
Fault Management Configuration
Guide (76.8600-50115)
Provides an overview of 8600 system fault management,
including fault source, types and status as well as instructions on
how to configure it with CLI.
8600 Smart Routers
Frame Relay Configuration Guide
(76.8600-50120)
Provides an overview of 8600 system Frame Relay applications,
including interfaces; Performance Monitoring; protection; Traffic
Management as well as instructions on how to configure them
with CLI.
8600 Smart Routers
Hardware Installation Guide
(76.8600-40039)
Provides guidance on mechanical installation, cooling,
grounding, powering, cabling, maintenance, commissioning and
ESW downloading.
8600 Smart Routers
Interface Configuration Guides
The Interface Configuration Guides provides an overview of the
8600 NEs interface functions, including NE supported interface
types and equipping; interface features; configuration options and
operating modes; fault management; performance monitoring;
interface configuration layers and port protocols as well as
instructions on how to configure them with CLI. The following
interface configuration guides are available:
• 8600 Smart Routers Network Interfaces Configuration
Guide (76.8600-50161) (for 8602 Smart Router, 8615 Smart
Router and 8665 Smart Router)
• 8609 Smart Router and 8611 Smart Router FP7.0 Interface
Configuration Guide (76.8670-50179)
• 8600 Smart Routers FP7.0 Interface Configuration Guide
(76.8670-50180) (for 8630 Smart Router and 8660 Smart
Router)
8600 Smart Routers
IP Forwarding and Traffic
Management Configuration Guide
(76.8600-50122)
Provides an overview of 8600 NEs IP, forwarding and traffic
management functionality, including: IP addressing; IP hosting
(ARP, DHCP); IP routing (static); ACL; Differentiated Services
(Policing, Queue Management, Shaping) as well as instructions
on how to configure them with CLI.
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
10

About This Manual
Document Title Description
8600 Smart Routers
Management Communications
Configuration Guide
(76.8600-50125)
Provides an overview of 8600 system management
communications functions, including communication protocols:
BMP; FTP; RADIUS; SNMP; SSH; TELNET as well as
instructions for configuring them with CLI.
8600 Smart Routers
Mobile Optimization Configuration
Guide (76.8600-50100)
Provides an overview of 8600 system Mobile Optimization
applications as well as instructions on how to configure them
with CLI.
8600 Smart Routers
MPLS Applications Configuration
Guide (76.8600-50123)
Provides an overview of 8600 NEs MPLS applications (including
FRR (one-to-one and facility backup); LDP; protection and
Traffic Engineering), MPLS-TP applications (including OAM,
linear protection), S-MPLS applications as well as instructions
on how to configure them with CLI.
8600 Smart Routers
Performance Counters Reference
Guide (76.8600-50143)
Provides an overview of 8600 system supported performance
counters.
8600 Smart Routers
Reference Manuals
The reference manuals describe the 8600 network element
features including:
• NE enclosure, baseboard, power supply modules, and
interfaces in 8602 Smart Router FP7.0 Reference Manual
(76.8670-40130)
• NE enclosure, baseboard, power supply modules, interfaces
and physical LM types in 8609 Smart Router FP7.0 Refer-
ence Manual
• NE enclosure, baseboard, power supply modules, SCMs, HM
and LM types in 8611 Smart Router FP7.0 Reference Manual
• NE enclosure, baseboard, power supply modules, and in-
terfaces in 8615 Smart Router FP7.0 Reference Manual
(76.8670-40132)
• NE subrack, fan modules, CDCs, line cards and IFMs in 8630
Smart Router FP7.0 Reference Manual
• NE subrack, fan modules, CDCs, line cards and IFMs in 8660
Smart Router FP7.0 Reference Manual
• NE subrack, fan modules, line unit and switch unit in 8665
Smart Router FP7.0 Reference Manual (76.8670-40128)
8600 Smart Routers
Routing Protocols Configuration
Guide (76.8600-50121)
Provides an overview of 8600 NEs routing protocols, including
BFD; BGP; BGP MP; ECMP; IS-IS; OSPF and VRRP as well as
instructions on how to configure them with CLI.
8600 Smart Routers
SNMP MIB Support
(76.8600-50116)
Describes SNMP MIB support by the 8600 NEs and provides
information on the supported objects and traps. For further
information on SNMP MIBs, see the related RFCs.
8600 Smart Routers
Statistic Counters Reference Guide
(76.8600-50142)
Provides an overview of 8600 system supported statistic counters.
8600 Smart Routers
Synchronization Configuration
Guide (76.8600-50114)
Provides an overview of 8600 NEs synchronization functionality,
including physical layer Frequency Synchronization (SEC, EEC);
PTP Frequency Synchronization; Phase-Time Synchronization
(L2 and L3 applications) as well as instructions on how to
configure them with CLI.
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
11

About This Manual
Document Title Description
8600 Smart Routers
Test and Measurement Configuration
Guide (76.8600-50124)
Provides an overview of 8600 NEs measurement and connectivity
verification tools, including Ethernet loopback; IP ping and
traceroute; MAC swap loopback; MPLS ping and traceroute;
PLT; PWE3 loopback; VCCV (BFD, LSP ping) as well as
instructions on how to configure them with CLI.
8600 Smart Routers
VPNs Configuration Guide
(76.8600-50128)
Provides an overview of 8600 system virtual private network
(VPN) layer 3 applications as well as instructions on how to
configure them with CLI.
8000 Intelligent Network Manager
Online Help
Provides instructions on how different operations are performed
with the 8000 Intelligent Network Manager. Describes also
different parameters and controls of the 8000 Intelligent Network
Manager dialogs and windows.
Note that the Online Help is not available on the Portal but it is
incorporated in the 8000 Intelligent Network Manager.
Document Conventions
This is a note symbol. It emphasizes or supplements information in the document.
This is a caution symbol. It indicates that damage to equipment is possible if the instructions
are not followed.
This is a warning symbol. It indicates that bodily injury is possible if the instructions are not
followed.
Documentation Feedback
Please contact us to suggest improvements or to report errors in our documentation:
Email: fi-documentation@tellabs.com
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
12

8600 Smart Routers Discontinued Products
8600 Smart Routers Discontinued Products
8600 Smart Routers Manufacture Discontinued (MD) notifications are available on the Tellabs
and Coriant Portal, www.portal.tellabs.com > Product Documentation & Software > Data
Networking > [8600 Smart Router product name] > Product Notifications.
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
13

Safety Notes
Safety Notes
This chapter lists safety notes and their translations for 8600 network elements.
Intended Purpose
The equipment shall be used only for its intended purpose.
Das Gerät soll nur für den vorgesehen Einsatzzweck verwendet werden.
CAUTION: Do not insert an RJ-11 (telephone) plug into Ethernet or E1/T1 ports. Equipment
damage may result.
ACHTUNG: Stecken Sie keine RJ-11 (Telefon) Stecker in die Ethernet oder E1/T1 Anschlüsse
da dieses zu einer Beschädigung des Gerätes führen kann.
CAUTION: Do not climb on or stand on the 8600 network element. Neither the network element
nor its enclosure is designed to support the weight of a person.
ACHTUNG: Steigen Sie oder stellen Sie sich nicht auf das 8600 Netzwerk Element. Weder
des Netzwerk Element noch das Gehäuse sind dafür ausgelegt worden das Gewicht einer
Person zu tragen.
Class 1 Laser Product
Class 1 laser product.
Laserprodukt der Klasse 1.
WARNING: No other types of lasers can be used than supplied and approved by Coriant. If
other types are used, the laser class and compliance to laser safety and EMC standards
must be checked.
WARNUNG: Verwenden Sie keine anderen als die von Coriant gelieferten und zugelassenen
Lasertypen. Falls Sie andere Typen verwenden, müssen die Laserklasse und die Einhaltung
von Lasersicherheits- undEMV-Normengeprüftwerden.
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
14

Safety Notes
WARNING: Install only lasers that have been demonstrated to meet Class 1 eye safe levels by
a Nationally recognized Authority such as The Food and Drug administration's 21CFR1040
Laser Energy Source, UL 60950-1 Information Technology equipment and European norms
EN60950-1, EN60825-1 and EN60825-2. Failure to use laser transceivers which meet these
standards could result in eye damage to users or service personnel working around the
equipment.
WARNUNG: Installieren Sie nur Laser der Klasse 1 die die Augenschutz Richtlinien
der staatlich anerkannten Organisationen wie z.B. The Food and Drug administration’s
21CFR1040 Laser Energy Source, UL 60950-1 Information Technology equipment oder die
Europa Normen EN60950-1, EN60825-1 und EN60825-2 erfüllen. Laser die diese Standards
nichterfüllenkönnenzuVerletzungenanAugendesBenutzersunddesServicePersonals
das in der Nähe der Geräte arbeitet führen.
WARNING: Optic operation should be verified by observing the status LEDs. Do not look into
the laser or fiber to verify operation.
WARNUNG: Überprüfen Sie die Funktionstüchtigkeit der Optischen Einheit anhand der Status
LED. Schauen Sie nie in den Laser oder die Glasfaser um die Funktion zu prüfen.
WARNING: Because invisible radiation may be emitted from the aperture of the port when no
fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
WARNUNG: Aus der Stecker Öffnung können unsichtbare Strahlen emittieren wenn kein
Glasfaserkabel angeschlossen ist. Vermeiden Sie es sich den Strahlungen auszusetzen und
starren Sie nicht in die Öffnungen.
Jewelry Removal
WARNING: Before working on equipment that is connected to power source, remove jewelry
(including rings, necklaces, and watches). Metal objects will heat up when connected to
power and ground and can cause serious burns or weld the metal object to the terminals.
WARNUNG: Bevor Sie an Geräten arbeiten die an eine Spannungsversorgung angeschlossen
sind, entfernen Sie all Ihren Schmuck (einschließlich Ringe, Ketten und Uhren). Metallobjekte
erhitzen sich wenn sie einen Kurzschluss zwischen Spannungsversorgung und Masse/Erdung
verursachen. Dieses kann zu schweren Verbrennungen führen oder das Anschweißen an die
Anschlussklemmen zur Folge haben.
Installation and Maintenance
WARNING: This equipment is to be installed and maintained by qualified service personnel
only.
WARNUNG: Dieses Gerät darf nur von qualifiziertem Fach- oder Servicepersonal installiert
oder gewartet werden.
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
15

Safety Notes
CAUTION: Electrical interfaces may require external protection devices to safeguard against
overvoltages, transients, earth potential differences and/or power cross-contacts.
ACHTUNG: Elektrische Anschlüsse benötigen evtl. externe Schutzschaltungen
um sie vor Überspannung, Einschaltspitzen, Erdpotentialunterschieden und/oder
Fremdspannungsüberlagerung zu schützen.
CAUTION: While handling the modules (Interface Modules, Line Modules, High Speed
Modules, SCM, CDC, Line Cards, Power Modules, Power Input Modules and Fan Modules) of
the 8600 network elements, always take care of proper handling, e.g. do not bend or twist
the modules, do not touch the components on the modules, take care of good ESD working
practices, do not use excessive force while inserting or removing the modules, do not drop
the modules.
ACHTUNG: Achten Sie darauf, dass Sie mit den Modulen (Schnittstellenmodulen,
Netzmodulen, Hochgeschwindigkeits-Netzmodulen, SCM, CDC, Netzkarten, Netzteilmodulen,
Netzeingangsmodulen und Lüftermodulen) der 8600-Netzwerkelemente sorgsam umgehen
und diese nicht verbiegen oder verdrehen. Berühren Sie nicht die Bauteile auf den Modulen.
Wenden Sie beim Ein- oder Ausbauen der Module keine übermäßige Kraft an und lassen Sie
die Module nicht fallen. Beachten Sie außerdem die Arbeitsrichtlinien im Zusammenhang
mit elektrostatischer Entladung.
WARNING: For US usage: this equipment must only be used with a Nationally Recognized
Testing Laboratory (NRTL) approved power supply.
WARNUNG: Für den Gebrauch in den USA: Dieses Gerät darf nur mit einer von einer national
anerkannten Test Einrichtung (NTRL) zugelassenen Spannungsversorgung betrieben werden.
WARNING: Read the installation instructions before you connect the system to its power
source.
WARNUNG: Lesen Sie die Installationsanweisungen bevor Sie das System an die
Spannungsversorgung anschließen.
WARNING: When installing or performing maintenance on the equipment, the ground
connection must always be made first. Never operate or maintain an ungrounded equipment.
WARNUNG: Bei der Installation oder bei Wartungsarbeiten am Gerät muss die Masse/Erdung
immer als erstes angeschlossen werden. Betreiben Sie oder arbeiten Sie niemals an einem
Gerät das nicht geerdet ist.
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
16

Safety Notes
Lightning Activity
WARNING: Do not work on the system or connect or disconnect cables during periods of
lightning activity.
WARNUNG: Arbeiten Sie während eines Gewitters mit Blitzschlag nicht an dem Gerät oder
schließen Sie auch keine Kabel an bzw. trennen Sie keine ab.
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
17

1 Network Element Overview
1 Network Element Overview
The 8602 Smart Router is an optimized cell site router for macro and small cell backhauling.
The 8602 Smart Router is an extremely compact IP/MPLS and Ethernet device meeting various
networking needs. 8602 Smart Router 8602-A variant provides 2 optical SFP and 4 electrical
Gigabit Ethernet ports for access and network connectivity. 8602 Smart Router 8602-D variant
offers the same number of Gigabit Ethernet interfaces, all SFP-based. 8602 Smart Router is a perfect
fit for IP- or Ethernet-based traffic aggregation with full QoS awareness and IP routing capabilities.
1.1 Enclosure
Fig. 1 8602 Smart Router Enclosure with Outdoor Kit Installed
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
18

1 Network Element Overview
Fig. 2 8602 Smart Router with Service Cover Open
1.1.1 Baseboard
The 8602 Smart Router is a stand-alone device and uses a baseboard architecture. This means that
the functionality including the interfaces has been integrated into a single main baseboard. All the
interfaces can be accessed under the access cover.
1.1.2 Product Variants
The 8602 Smart Router is available in several variants depending on the equipping:
• 8602-A AC (support for mains powering, 100 - 240Vac nominal input voltages)
• 8602-A DC (support for both -48 Vdc and +24 Vdc nominal input voltages)
• 8602-D AC (support for mains powering, 100 - 240Vac nominal input voltages)
• 8602-D DC (support for both -48 Vdc and +24 Vdc nominal input voltages).
Different installation accessories and kits are available for the network element (please see the table
below). Refer to the 8600 Smart Routers Hardware Installation Guide for more information.
Product Code Product Description
81.86K-8602ADPT-R6 8602 19/21/23IN/600MM RACK ADPT FOR 2 NE
81.86K-8602IND-R6 8602 INDOOR KIT AC/DC
81.86K-8602OUTD-R6 8602 OUTDOOR KIT AC/DC
81.86K-8602WMNT-R6 8602 WALL MOUNT ADAPTER KIT WITH HANDLE
81.86K-8602SUNC-R6 8602 SUN COVER
76.8670-40130A 8600 Smart Routers
© 2015 Coriant. 8602 Smart Router FP7.0 Reference Manual
19

1 Network Element Overview
1.1.3 Interfaces
The 8602 Smart Router provides the following types of interfaces:
8602-A:
• 2 x 1000BASE-X (SFP transceiver)
• 4x100/1000BASE-T
• Management interface: RS-232 serial (RJ-45 type) and Ethernet ports (management via user ports
possible).
8602-D:
• 6 x 1000BASE-X (SFP transceiver)
• Management interface: RS-232 serial (RJ-45 type) and Ethernet ports (management via user ports
possible).
1.1.4 Cooling
The 8602 Smart Router is a free convection-cooled equipment. Thus there are no fans nor air dust
filter. For adequate cooling please follow the installation instructions for the equipment.
The baseboard is able to monitor the equipment temperature. The temperature warning is raised
when the measured temperature exceeds +80 °C/177.8 °F. The warning indicates that the operating
ambient temperature is high and about to exceed the allowed operating range. This will occur at
ambient near +65 °C/149 °F. The equipment will go to reset mode after 15 minutes if the measured
temperature is +90 °C/194 °F or higher or immediately if it is +100 °C/212 °F or higher. This is to
protect the equipment from permanent damage caused by high temperature.
1.2 NE Powering
There are two different powering possibilities for the 8602 Smart Router depending on the product
variant:
• AC: 100 Vac … 240 Vac nominal input voltage range
• DC: -48 Vdc/+24 Vdc nominal input voltage.
The power supply is a separate module inside the 8602 Smart Router. The power module is not
field-replaceable. The power modules, connectors and mechanics are different in each type. The
power module has an isolated AC/DC or DC/DC converter to create the needed supply voltage to
operate the NE.
The AC power module features are the following:
• AC/DC converter
• Input over-current protection (fuse)
•EMIfiltering
8600 Smart Routers 76.8670-40130A
8602 Smart Router FP7.0 Reference Manual © 2015 Coriant.
20