manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Crane
  6. •
  7. Switch
  8. •
  9. Crane AZONIX-DYNALCO SW-200B Use and care manual

Crane AZONIX-DYNALCO SW-200B Use and care manual

Other Crane Switch manuals

Crane Barnes ESPS Series User manual

Crane

Crane Barnes ESPS Series User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Azonix-Dynalco, 3690 N.W. 53rd Street, Fort Lauderdale, U.S.A.
(954)739-4300 • Fax (954)484-3376 • • [email protected]
DIP SWITCH SETTINGS
Switches 1 & 2 set the
full-scale frequency range Switches 3 & 4 set the
overspeed relay logic
DIP
SW 1 DIP
SW 2 Full-Scale
Range DIP
SW 3 DIP
SW 4 Relay
Logic
OFF OFF =0 –11,200 Hz ON N/A =Ener
g
izes
Above
Setpoint
OFF ON = 0 –5,000 Hz OFF N/A =De-Ener
g
ize
Above
Setpoint
ON ON = 0 –1,000 Hz N/A ON = Latches
N/A OFF =Does not
Latch
Installation and Calibration Instructions
SW-200B Speed Switch
1. Installation: Mount the SW-200B to a secure bracket off the engine. If
on-enginemountingisnecessary,shockmountsarerecommended.Wire
according to connection diagram on reverse. Shielded cable is
recommended.Shieldshouldbebroughttogrounddirectly.TheSW-200B
will work with most magnetic pickups provided the signal amplitude is
greater than 50 mVrms and less than 70 Vrms. Mount pickup according
to manufacturer’s instructions.
2. Calibration: Determine the setpoint frequencies from an RPM value
using the following formula:
Frequency = RPM x No. of Teeth (Holes)
60
A. Verify the current calibration: usea signalgenerator. Connect ittothe
SW-200B magnetic pickup input.
B. Confirm the DIP switches are properly set for the frequency range and
overspeed relay logic desired. (See chart below.)
C. Setthesignal generatoroutput toatleast 10%below thelowestsetpoint.
Slowly increase the frequency. Using an ohmmeter across the relay
contacts, determine the frequency at which each relay changes state.
a. Change a setpoint: removetheappropriate accessholescrew toreach
the setpoint's relay adjustment trim pot.
b. Setthe signalgeneratortothefrequency atwhichtherelayshouldchange
state. Connect it to the SW-200B magnetic pickup input.
c. Using a small, flat screwdriver, adjust the trim pot for the appropriate
relay until the relay changes state.
d. Decrease the frequency, then slowly increase it to verify that the relay
trips at the appropriate point.
Replace the access hole screw
.
SW-200B is a trademark of Dynalco Controls
DYNALCO CONTROLS RESERVES THE RIGHT TO CHANGE THESE SPECIFICATIONS WITHOUT NOTICE.
© 2002 Azonix-Dynalco 145F-12044, Rev 0
CONNECTION DRAWINGS
SW-200B
p:rML,Rq
.::i:,
·:::
..
.:::·
•·::::::·
:~·-~~:
··~"
SW
•
200B
""
•u•'"
,,.o
••
01u•
..
•no
......
+
..
.,
_,.,
-1
3.
125
(79.4)
2 (50.8)
_J
i--
--
-
-------
8 (203.2)
____
____
__
_,
.25 (6.4)
DIA
.
i--
-
-----
----
-----<18
.5 (215.
91------
------
"'"
+A
9-40Vdc
Input
Power
Dimensions
in
inches (millimeters)
Optional
Dynalco Indicators
G-101 Analog Meter
or
DPM-105 Digital Meter
(9-40 Vdc power)
SW-200B
shown
with
power
OFF,
no
input, all relays deenergized.
Note
label on SW-200B in Overview, above.
Otber setups are available.
~
AZD
~