Crownline AC-185 User manual

Model
AC-185
Instruction Manual
PLEASE READ THE INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT.
AIR COOLER
Table of Contents
FEATURES ......................... 1
STRUCTURE ....................... 2
WARNINGS AND PRE-CAUTIONS ...... . 1
CONTROL PANEL FUNCTION .............. 3
........... 5
................ 7
TECHNICAL REFERENCE DATA
...
.
...
.
...
.
..
.
..
.
.
.
.
.
.
.
8
8
OPERATING INSTRUCTIONS
SETUP INSTRUCTION
IMPORTANT NOTES

1
WARNINGS AND PRE-CAUTIONS STRUCTURE
1 . Warnings
2 .Notices:
FEATURES
Do not operate the unit near flammable or explosive gas.
Keep unit at least 1 meter away from TV or Radio for interference.
Do not unplug power by pulling the power cord.
Empty water tank and unplug the power before putting unit in storage.
Do not wash the unit using water or chemical solvent.
Turn off machine, unplug the power, and then use dry cloth for cleaning.
Do not shake or beat the unit.
Do not insert any object, spray insecticide or chemical solvent on the unit.
Do not block wind inlet and outlet of the unit.
Do not mix old and new batteries in remote control.
Disconnect power supply if the unit will not be used for long time.
Use the specified power supply.
Do not operate the unit with wet hands.
Do not unplug the power supply while machine is running.
Extension power cord is not recommended.
Do not insert fingers, sticks or other objects into the unit.
In case of bad smell, turn off the unit and then shut off power supply.
Do not cover the air outlet and air inlet.
If the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
3-in-1 functions: cooler, air purifier, and humidifier.
Purify air by removing dusts and unpleasant odors.
Purify and sterilize air by generating negative ion.
Environment-friendly, large cooling capacity, and high performance rating.
Add ice to water tank to achieve additional cooling, down to 3-5 C.
Energy efficiency and low power consumption.
Water curtain provides moisture to protect skin from dryness.
Activated carbon filter and nylon filters can be alternative at will.
The appliance must not be located immediately below a socketoutlet Do not use this appliance;
in the immediate surroundings of a bath a shower or swimming pool, .
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
2
1
2
3
4
5
6
8
1 Handle.
2. Control Panel
3. Horizontal Vane
4. Vertical Vane
5. Caster
6. Filter frame
7. Power Cord
8. Water tank
7

3 4
CONTROL PANEL FUNCTION CONTROL PANEL FUNCTION
TIMER
14
TIMER
SPEED
WIND/COOL
ANION
STAND-BY
MODE
25
36
1.
2. SPEED button
3. MODE button
4.
5. ANION
6.
TIMER button for timer
WIND COOL button for air flow or cooling/
button
stand by run the machine and stand by the machine
-,-
Press TIMER button to set the time off the unit while the unit is running." "
The first press “TIMER” button to enter time setting mode.
The second press “TIMER” button to adjust time . Press the button once by,
an increase of hour up to hours then return so the cycle1 , 24 , 0, ; when setting
the end stop flashing after seconds5 , and exit the set state;
When the user is set to 0 h,
then flash for about 5 seconds,automatic exit t
ime
status
MODE
Press MODE button to setting run mode ." "
Normal wind Natural wind Sleep Wind Super Wind
ANION
Press ANION button to setting run mode ." "
The premise of the fan open press the control key can open the anion, 。
For extra cooling operation, place ice into the large compartment and close the water tank.
EMERGENCY STOP
Press 'SPEED' button on control panel to select fan speed as below.
In the second down as. For refrigeration and wet function .
When the water within the machinery alarm. Filled with water,
The next time when the first. For refrigeration function .
to button and restore the functions of refrigeration.,
When a third off. To put the wind function .
By the fourth, two functions stop, recordset .
WIND
Open or take down the detachable water tank.
COOL & WIND
Add clean water into the water tank
Press 'WIND & COOL' button .
Press ' Stand-by ' button
WIND & COOL
HI STRONG:
MI MEDIUM:
COOL
LO SLOW:
SPEED
NOTE:

56
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS
How to use the remote control panel:
2.SPEED button: Three wind flow level; “HIGH”, “MIDDLE”, “LOW” with
three LED indicator.
1.TIMER button: one press increase 1 hour , total 24 hours,
If the set timer is reached, the machine automatically shut off.
4.COOL button: press this button to cooling.
3.MODE
WIND button: press button can change wind bearing 120°this
Note: If the remote control is not going to be used for a long time, please take out
the batteries to avoid corrosion of parts for leakage of electrolyte from batteries.
6. Button: can run the machine and power the machine
5.ANION button: press this button, then the Anion function isturn on.
button :Press this button toselect Normal, Natural, Sleep mode.
How to install batteries
Slide the cover to open
Be sure the direction
is correct
Inserting batteries
1. Open the back cover, ;
and take off the isolating film on the batteries
2. Put the batteries inside the slot, with anode and cathode in right directions;
3. Put on the back cover.
Notices:
1). The anode and cathode of the batteries must be corresponding to the signs of
“+” and “-” on the remote control;
2). Do not use new battery cells together with run-down cells;
3). For long time no use, take out the batteries;
4). To prevent environmental pollution, take out the used batteries and dispose
safely and appropriately.

7 8
CLEAN & REPLACE THE FILTER
The filter is already assembled before delivery from factory. But the filter
should be cleaned or replaced after a certain time use. It should be operated by
Technical people or ask for advice by local distributor. The method is mentioned
1.Hold the filter down to the board position with force to back side can remove
SETUP INSTRUCTION
IMPORTANT NOTES
1.The range of the remote control is five meters.
2.Batteries must be inserted into the remote control which must be pointed
direct at the unit, using the front portion to activate.
3.Do not obstruct the air outlet when operating the unit.
4.Use indoor only.
5.Should it be necessary to move the unit after the water has been added,
roll gently to the required position and activate the bracket the castors.
6.The unit is safe and reliable if the power socket is earthed.
8.Always ensure that there is water in the unit when in use for cooling.
Model AC-185
Rated Voltage AC220 240V 50Hz
- /
Rated Power(cooling) 80W
Airflow Volume 400 m 3/h
Net Weight 7kg
Water tank 6L
Meas.of
Unit WXDXH( )
344X301.5X677mm
Technical Reference Data
9.If the supply cord is damaged,please contact your dealer for help.
Note: 1 Filter can be used for one year normally, if damage occurs, the filter.
should be changed immediately.
Open or take down the detachable water tank, put
the ice box into water tank, or adding water。Filter Filter Frame
below.
filters.
Electrical Protection Class Ⅱ
Never place any electric tools in your household refuse.
To comply with European Directive 2012/19/EC concerning old electric and electronic equipment
and its implementation in national laws, old electric tools have to be separated from other waste
and disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the demand to return electrical devices:
As an alternative to returning the electrical device, the owner is obliged to cooperate in ensuring
that the device is properly recycled if ownership is relinquished. This can also be done by
handing over the used device to a returns center, which will dispose of it in accordance with national
commercial and industrial waste management legislation. This does not apply to the accessories and
auxiliary equipment without any electrical components which are included with the used device.
7.Clean the filter every 20-30 days of operation for optimum performance .
gently rinsing filter in clean water
How to clean the filter:
take out the dirty filter and clean it (it can be cleaned
please install it as per directive.
2. tap the filter with certain object for
cleaning. if the filter is really dirty, dip it into natural detergent solution to
wash and flush with water.
3.Put the cleaned or newly replaced filter slightly into its proper position
Table of contents
Popular Air Conditioner manuals by other brands

Tokyo Gas
Tokyo Gas MISTY IBD-4110ACSKJ3M manual

GE
GE AEL05 installation instructions

Amana
Amana PGB**C installation instructions

Allied Air
Allied Air 4SCU14LE SERIES Installation and maintenance instructions

Convair
Convair EA70 owner's manual

National Comfort Products
National Comfort Products NCPAH Series installation guide