Cyan Z22 Technical manual

Release 5.0 Cyan, Inc. 2013
CYAN
Z-Series
Engineering and Planning Guide

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 2 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
Copyright and Trademark
Copyright © 2009 – 2013 Cyan, Inc. All Rights Reserved. All text, images, graphics, animation, videos,
music and other materials in this publication are subject to the copyright and other intellectual property
rights of Cyan, Inc. or its licensors. These materials may not be reproduced, transmitted, distributed,
modified or posted to other websites or printed without the express written permission of Cyan, Inc.
Cyan®, the Cyan logo, Z22™, Z33®, Z77®, Blue Planet™ and other trademarks and service marks of Cyan
appearing in this publication are the property of Cyan. Trade names, trademarks and service marks of other
companies appearing in this publication are the property of the respective holders.

Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 3
Naming Conventions
Throughout this guide, a standardized system is used to identify various functions or to stress importance to
the reader.
Important! — Information that must be seriously considered.
Note: Special suggestions, advice, or information that should be seriously considered.

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 4 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
Safety Symbols and Labels
Read and understand all warning labels before working with equipment.
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury.
Before you work on any equipment, be aware of the hazards involved with electrical circuitry
and be familiar with standard practices for preventing accidents.
SAVE THESE INSTRUCTIONS
Caution
Environment requires
a moderate level of awareness. There is a moderate level of danger to
yourself or others.
Laser Equipment Present
Electrostatic Discharge (ESD) Sensitive Equipment
Safety and Compliance Information
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury.
Before you work on any equipment, be aware of the hazards involved with electrical circuitry
and be familiar with standard practices for preventing accidents.
SAVE THESE INSTRUCTIONS
Warning Before working on the equipment, remove conductive clothing and jewelry (for example:
rings, necklaces, bracelets, key chains, metal wristwatches, and apparel with metal buttons).
Conductive items can cause serious burns or weld the metal object to the terminals.
Warning Only trained and qualified personnel (as defined in IEC 60950-
1 and AS/NZS 3260) should be
allowed to install, replace, or service this equipment.
Warning Installation of the equipment must comply with local and national electrical codes.
Warning This unit is intended for installation in restricted access areas. A restricted access area can
be accessed only through the use of a special tool, lock and key, or other means of security.
Warning Read the installation directions before connecting the system to the power source or
installing the modules and the accessories which are intended to be used only with Cyan
Optical Packet system.
A copy of the installation documents and the list of accessories can be found in CyLibrary in
Cyan Central at http://cyaninc.com/resources/compliance.

Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 5
Warning
Do not perform cabling on an electrically live system. Before performing any of the following
procedures, ensure that power is removed from the DC circuit.
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Warning No user serviceable parts are contained inside. Contact the manufacturer regarding service
of this equipment.
Warning This device requires short-circuit
protection to be provided as part of the facility. Install only
in accordance with national and local wiring regulations.
Warning The copper RJ-45 SFP modules are suitable for connection only to shielded Ethernet
intra-building cabling grounded at both ends.
Warning Do not work on the system, or connect or disconnect cables during periods of lightning
activity.
Warning Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe
bodily injury and equipment damage.
Warning Stability hazard. The rack must be stabilized or bolted to the floor before you mount this
shelf assembly. Failure to ensure rack stability may cause the rack to tip over.
Warning To prevent bodily harm when mounting or servicing this device in a rack, you must ensure
that the shelf remains stable. The Following guidelines are provided to ensure your safety:
•This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
•When mounting this unit in a partially filled rack, load the rack from bottom to the
top with the heaviest component at the bottom of the rack.
•If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Warning
Never use the cable management guide to lift the chassis. This is NOT the intended purpose
of the cable guide. Personal injury and/or damage to the Z22 shelf assembly may result.
Warning
Ensure that all power wiring is sufficient for the load carried to the shelf assembly. All wiring
and installation must be in accordance with local building and electrical codes acceptable to
the authorities in the countries where the equipment is installed and used.
Warning This equipment must be grounded. Never defeat the ground conductor or operate the
equipment in the absence of a suitably installed ground conductor. Contact the appropriate
electrical inspection authority or
an electrician if you are uncertain that suitable grounding is
available.
Warning When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Warning This unit might have more than one power supply connection. All connections must be
removed to de-energize the unit.
Warning For connections outside the building where the equipment is installed, the 10/100/1000
Ethernet ports must be connected through an approved network termination unit with
integral circuit protection.
Warning Operating this equipment in an area that exceeds ambient air temperature of 50° C / 120° F
will result in overheating.

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 6 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
Warning Operating I-Temp equipment in an area that exceeds ambient air temperature of 65° C /
149° F will result in overheating.
Warning Ultimate disposal of this product should be handled according to all national laws and
regulations.
Warning Connect the unit only to DC power source that complies with the safety extra-low voltage
(SELV) requirements in IEC 60950-based safety standards.
Warning This is a Class A product. In a domestic environment this product may cause radio
interference, in which case the user may be required to take adequate measures.
Warning This is a Class A product based on the standard of the VCCI Council. If this equipment is
used in a domestic environment, radio interference may occur, in which case, the user may
be required to take corrective actions.
Warning This equipment is a class A product and should be used and installed properly according to
the Hungarian EMC Class A requirements (MSZEN55022). Class A equipment is designed for
typical commercial establishments for which special conditions of installation and
protection distance are used.
Warning This is a Class A Information Product. When used in residential environment, it may cause
radio frequency interference, under such circumstances, the user may be requested to take
appropriate countermeasures.
Warning This is a Class A Device and is registered for EMC requ
irements for industrial use. The seller
or buyer should be aware of this. If this type was sold or purchased by mistake, it should be
replaced with a residential-use type.
Warning Air Management Boards are required to meet EMI certification standards. Air Management
Boards must be installed to cover all unused slots.
Caution
Environment requires a moderate level of awareness. There is a moderate level of danger to
yourself or others.
Caution To avoid damage to the Z22 shelf, the fan module should not be removed for longer than 60
seconds from an operating system.
Caution Keep all ventilation openings clear and unobstructed.
Caution To prevent damage, do NOT install or remove XFP/SFP transceivers with cables attached.
Caution The Air Management Boards are essential to proper cooling of the shelf assembly. Air
Management Boards must be installed over all unused slot openings to prevent damage
from overheating.
Caution Do not apply power to the unit until you complete all installation steps and check the
continuity of the battery and battery return. When terminating power, return, and frame
ground, do not use soldering lug connectors, push-in connectors, quick-connect
connectors, or other friction-fit connectors.
Caution Star washers must be used for anti-rotation on all power and ground fasteners.
Caution Use copper conductors only.

Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 7
Caution This equipment is suitable for installation in Network Telecommunications Facilities,
Customer Premises, and OSPs. If this equipment is installed in a Customer Premise or an
OSP environment, the appropriate hardened modules must be used and DC power interfaces
must be connected to DC power via a proper fuse panel.
Caution The intra-building port(s) of the equipment or sub-assembly is suitable for connection to
intra building or unexposed wiring or cabling only. The intra-building port(s) of the
equipment or sub-assembly MUST NOT be metallically connected to interfaces that connect
to the Outside Plant (OSP) or its wiring. These interfaces are designed for use as
intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue
4) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is
not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Caution This equipment is intended to be grounded to a Common Bonding Network per GR-CORE
1089. Ensure that the host is connected to earth ground during normal use.
Caution
Hazard Level 1M Laser radiation. Do not view directly with non-attenuating optical
instruments.
Caution This product may employ Class 1M SFP or XFP. Check pluggable transceiver label for laser
classification.
Caution
Some Cyan shelf components are Electrostatic Discharge (ESD) sensitive devices. Conform
to the following rules:
•Observe standard precautions for handling ESD-sensitive devices.
•Assume that all solid-state electronic devices are ESD-sensitive.
•Ensure that you are grounded with a grounded wrist strap or equivalent while
working with ESD-sensitive devices.
•Transport, store, and handle ESD-sensitive devices in static-safe environments.
Note This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case, the user will be required to correct
the interference at own expense.
Note The battery return connection is treated as DC-isolated (DC-I), as defined in Telcordia
GR-1089-CORE Issue 3.
Note This Class A digital apparatus complies with Canadian ICES-003.

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 8 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1

700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 9
Contents
Safety Symbols and Labels.........................................................................................................................4
Safety and Compliance Information..........................................................................................................4
New in this Release....................................................................................................................................21
Chapter 1: Cyan Z-Series Shelves........................................................................................................23
1.1 Cyan Z22 Shelf............................................................................................................................... 23
1.1.1 Z22 Shelf Description .............................................................................................................. 24
1.1.2 Z22 Card Installation Guidelines ............................................................................................. 25
1.1.3 CEMi Controller Card: +24 Volt ............................................................................................. 26
1.1.4 Z22 Physical ............................................................................................................................ 26
1.1.5 Z22 External Timing ................................................................................................................ 27
1.1.6 Z22 Alarms .............................................................................................................................. 27
1.1.7 Z22 Shelf Power ...................................................................................................................... 28
1.2 Cyan Z33 Shelf............................................................................................................................... 29
1.2.1 Z33 Shelf Description .............................................................................................................. 31
1.2.2 Z33 Line Card Configuration Guidelines ................................................................................ 32
1.2.3 Common Equipment Module (CEMi) ..................................................................................... 33
1.2.4 Z33 Timing .............................................................................................................................. 35
1.2.5 Z33 Alarms .............................................................................................................................. 36
1.2.6 Z33 Shelf Power ...................................................................................................................... 36
1.2.7 Z33 Physical ............................................................................................................................ 37
1.3 Cyan Z77 Shelf v2 .......................................................................................................................... 37
1.3.1 Z77 Card Installation Guidelines ............................................................................................. 40
1.3.2 Z77 Power ................................................................................................................................ 41
1.3.3 Z77 Physical ............................................................................................................................ 41
1.3.4 Z77 Timing .............................................................................................................................. 41

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 10 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
1.3.5 Z77 Management ..................................................................................................................... 41
1.4 Cyan L-AMP Shelf ......................................................................................................................... 42
1.4.1 L-AMP Shelf Pinouts .............................................................................................................. 43
1.4.2 L-AMP Interfaces .................................................................................................................... 44
1.4.3 L-AMP OSC Specifications..................................................................................................... 45
1.4.4 L-AMP Features ...................................................................................................................... 45
1.4.5 L-AMP Applications ............................................................................................................... 45
1.4.6 L-AMP Physical ...................................................................................................................... 45
1.4.7 L-AMP Power .......................................................................................................................... 46
1.4.8 L-AMP Compliance ................................................................................................................. 46
Chapter 2: Z-Series Line Cards, Modules, Optics, and Optical Protection.....................................47
2.1 LAD Modules ................................................................................................................................. 49
2.1.1 Functional Interfaces................................................................................................................ 56
2.1.2 LAD OSC Specifications ......................................................................................................... 57
2.1.3 Management ............................................................................................................................ 57
2.1.4 Physical .................................................................................................................................... 57
2.1.5 Power ....................................................................................................................................... 58
2.1.6 Environmental .......................................................................................................................... 58
2.1.7 LAD Module Wavelength Assignments .................................................................................. 58
2.1.8 LAD-2P and LAD-8i 1310nm Add/Drop Port ........................................................................ 60
2.1.9 LAD-2G 1550nm Add/Drop Port ............................................................................................ 60
2.1.10 Compliance / Safety ................................................................................................................. 60
2.2 DTM-8 and DTM-8G Transponder Modules ................................................................................. 61
2.2.1 DTM-8/DTM-8G System Requirements ................................................................................. 64
2.2.2 Applications ............................................................................................................................. 64
2.2.3 DTM-8 Interfaces .................................................................................................................... 64
2.2.4 DTM-8G Interfaces ................................................................................................................. 64
2.2.5 DTM-8/DTM-8G Management ............................................................................................... 65
2.2.6 DTM-8/DTM-8G Physical ...................................................................................................... 65
2.2.7 DTM-8/DTM-8G Power .......................................................................................................... 65
2.2.8 DTM-8/DTM-8G Environmental ............................................................................................ 65
2.2.9 DTM-8/DTM-8G Compliance / Safety ................................................................................... 65
2.3 2.5G-LME4 Multiplex-Transponder Module ................................................................................. 66
2.3.1 System Requirements .............................................................................................................. 67
2.3.2 Interfaces .................................................................................................................................. 67

Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 11
2.3.3 Management ............................................................................................................................ 68
2.3.4 Physical .................................................................................................................................... 68
2.3.5 Power ....................................................................................................................................... 68
2.3.6 Environmental .......................................................................................................................... 68
2.3.7 Compliance / Safety ................................................................................................................. 68
2.4 PME-412 Packet Multiplexer Module ........................................................................................... 69
2.4.1 Synchronous Ethernet .............................................................................................................. 71
2.4.2 System Requirements .............................................................................................................. 71
2.4.3 PME-412 Ethernet Services, OAM, QoS, and Synchronization .............................................. 71
2.4.4 PME-412 Capacity ................................................................................................................... 72
2.4.5 Optical Transport ..................................................................................................................... 73
2.4.6 Interfaces .................................................................................................................................. 73
2.4.7 Management ............................................................................................................................ 73
2.4.8 Physical .................................................................................................................................... 73
2.4.9 Power ....................................................................................................................................... 74
2.4.10 Environmental .......................................................................................................................... 74
2.4.11 Standards.................................................................................................................................. 74
2.4.12 Compliance / Safety ................................................................................................................. 74
2.5 PME-216i Packet Multiplexer Module .......................................................................................... 75
2.5.1 Synchronous Ethernet .............................................................................................................. 78
2.5.2 System Requirements .............................................................................................................. 78
2.5.3 PME-216i Ethernet Services, OAM, QoS, and Synchronization ............................................ 78
2.5.4 PME-216i Capacity ................................................................................................................. 79
2.5.5 Standards.................................................................................................................................. 80
2.5.6 Optical Transport ..................................................................................................................... 80
2.5.7 Interfaces .................................................................................................................................. 80
2.5.8 Management ............................................................................................................................ 81
2.5.9 Physical .................................................................................................................................... 81
2.5.10 Power ....................................................................................................................................... 81
2.5.11 Environmental .......................................................................................................................... 81
2.5.12 Compliance / Safety ................................................................................................................. 81
2.6 PSW-10G10 Packet Module .......................................................................................................... 82
2.6.1 System Requirements .............................................................................................................. 85
2.6.2 Ethernet Services and Standards .............................................................................................. 85
2.6.3 Optical Transport ..................................................................................................................... 85

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 12 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
2.6.4 Interfaces .................................................................................................................................. 85
2.6.5 Management ............................................................................................................................ 85
2.6.6 Physical .................................................................................................................................... 85
2.6.7 Power ....................................................................................................................................... 86
2.6.8 Environmental .......................................................................................................................... 86
2.6.9 Compliance / Safety ................................................................................................................. 86
2.7 PSW-618 Packet Module ............................................................................................................... 87
2.7.1 System Requirements .............................................................................................................. 89
2.7.2 Ethernet Services and Standards .............................................................................................. 89
2.7.3 Optical Transport ..................................................................................................................... 89
2.7.4 Interfaces .................................................................................................................................. 89
2.7.5 Management ............................................................................................................................ 89
2.7.6 Physical .................................................................................................................................... 90
2.7.7 Power ....................................................................................................................................... 90
2.7.8 Environmental .......................................................................................................................... 90
2.7.9 Compliance / Safety ................................................................................................................. 90
2.8 TSW-10G10 Packet Aggregation and Transport Module .............................................................. 91
2.8.1 System Requirements .............................................................................................................. 92
2.8.2 Interfaces and Optical Transport .............................................................................................. 92
2.8.3 Management ............................................................................................................................ 93
2.8.4 Physical .................................................................................................................................... 93
2.8.5 Power ....................................................................................................................................... 93
2.8.6 Environmental .......................................................................................................................... 93
2.8.7 Compliance / Safety ................................................................................................................. 93
2.9 LAC-8 Lambda Aggregator Module .............................................................................................. 94
2.9.1 System Requirements .............................................................................................................. 94
2.9.2 Functional Interfaces................................................................................................................ 94
2.9.3 Management ............................................................................................................................ 95
2.9.4 Physical .................................................................................................................................... 95
2.9.5 Power ....................................................................................................................................... 95
2.9.6 Environmental .......................................................................................................................... 95
2.9.7 LAC-8 Wavelength Assignments ............................................................................................ 95
2.9.8 Compliance / Safety ................................................................................................................. 96

Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 13
2.10 LAC-4P Lambda Aggregator CWDM Terminal Multiplexer ........................................................ 97
2.11 SFT-8 Module Transponder Module .............................................................................................. 98
2.11.1 System Requirements ............................................................................................................ 100
2.11.2 Functional Interfaces.............................................................................................................. 100
2.11.3 Management .......................................................................................................................... 100
2.11.4 Physical .................................................................................................................................. 100
2.11.5 Power ..................................................................................................................................... 100
2.11.6 Environmental ........................................................................................................................ 101
2.11.7 Compliance / Safety ............................................................................................................... 101
2.12 SFT-10G16 Multi-Rate Transponder Module .............................................................................. 102
2.12.1 SFT-10G16 Applications ....................................................................................................... 104
2.12.2 System Requirements ............................................................................................................ 104
2.12.3 Management .......................................................................................................................... 104
2.12.4 Physical .................................................................................................................................. 104
2.12.5 Power ..................................................................................................................................... 104
2.12.6 Environmental ........................................................................................................................ 104
2.12.7 Compliance / Safety ............................................................................................................... 104
2.13 DTM-100G Transponder Module ................................................................................................ 105
2.13.1 System Requirements ............................................................................................................ 107
2.13.2 DTM-100G Applications ....................................................................................................... 107
2.13.3 Interfaces ................................................................................................................................ 107
2.13.4 Optical Transport ................................................................................................................... 108
2.13.5 Management .......................................................................................................................... 108
2.13.6 Physical .................................................................................................................................. 108
2.13.7 Power ..................................................................................................................................... 108
2.13.8 Environmental ........................................................................................................................ 108
2.13.9 Compliance / Safety ............................................................................................................... 109
2.14 MSE-1482 Multiservice SONET/SDH Aggregation/ Transport .................................................. 110
2.14.1 Applications ........................................................................................................................... 114
2.14.2 System Requirements ............................................................................................................ 114
2.14.3 Functional Interfaces.............................................................................................................. 114
2.14.4 GbE Support .......................................................................................................................... 114
2.14.5 Timing / Synchronization ...................................................................................................... 114
2.14.6 Management .......................................................................................................................... 114
2.14.7 Physical .................................................................................................................................. 115

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 14 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
2.14.8 Power ..................................................................................................................................... 115
2.14.9 Environmental ........................................................................................................................ 115
2.14.10 Compliance / Safety ........................................................................................................... 115
2.15 FLX-216i Multi-Rate OTN Muxponder Module ......................................................................... 116
2.15.1 System Requirements ............................................................................................................ 117
2.15.2 Applications ........................................................................................................................... 118
2.15.3 Interfaces ................................................................................................................................ 118
2.15.4 OTN Multiplexing and Cross-Connect Formats .................................................................... 118
2.15.5 Optical Transport ................................................................................................................... 118
2.15.6 Management .......................................................................................................................... 118
2.15.7 Physical .................................................................................................................................. 118
2.15.8 Power ..................................................................................................................................... 118
2.15.9 Environmental ........................................................................................................................ 119
2.15.10 Compliance / Safety ........................................................................................................... 119
2.16 WSS-402 and WSS-404 Wavelength Selective Switch ............................................................... 120
2.16.1 WSS DWDM Specifications ................................................................................................. 126
2.16.2 WSS OSC Specifications ....................................................................................................... 127
2.16.3 System Requirements ............................................................................................................ 127
2.16.4 Physical .................................................................................................................................. 127
2.16.5 Power ..................................................................................................................................... 127
2.16.6 Environmental ........................................................................................................................ 127
2.16.7 WSS/AWG-40 Wavelength Assignments ............................................................................. 128
2.16.8 Compliance / Safety ............................................................................................................... 128
2.17 Broadband Operating System Supervisor .................................................................................... 129
2.17.1 Shelf Compatibility ................................................................................................................ 130
2.17.2 CPU........................................................................................................................................ 130
2.17.3 RAM ...................................................................................................................................... 130
2.17.4 Timing.................................................................................................................................... 130
2.17.5 Craft ....................................................................................................................................... 130
2.17.6 Physical .................................................................................................................................. 130
2.17.7 Power ..................................................................................................................................... 130
2.17.8 Compliance ............................................................................................................................ 130
2.17.9 Electrical ................................................................................................................................ 131
2.18 BOSS Termination Module .......................................................................................................... 131
2.18.1 Shelf Compatibility ................................................................................................................ 133

Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 15
2.18.2 Physical .................................................................................................................................. 133
2.18.3 Timing.................................................................................................................................... 133
2.19 Line Card SYNC LED ................................................................................................................. 134
2.20 Ring Closure Modules .................................................................................................................. 135
2.21 XC-2800 Switch Fabric Modules ................................................................................................. 135
2.21.1 XC-2800 Applications ........................................................................................................... 137
2.21.2 System Requirements ............................................................................................................ 137
2.21.3 Capacity and Throughput....................................................................................................... 137
2.21.4 Redundancy and Protection ................................................................................................... 137
2.21.5 Physical .................................................................................................................................. 137
2.21.6 Power ..................................................................................................................................... 137
2.22 Optical Protection Groups ............................................................................................................ 138
2.22.1 Optical Protection Groups Equipment ................................................................................... 138
2.22.2 Optical Protection Groups – Rules and Guidelines ............................................................... 140
2.23 Optical Protection Switch ............................................................................................................. 141
2.23.1 1+1 Protection ........................................................................................................................ 141
2.23.2 Switching Modes ................................................................................................................... 142
2.23.3 Local or Remote Operation.................................................................................................... 142
2.23.4 OPS Specifications ................................................................................................................ 143
2.24 XFP, SFP, and SFP+ Transceivers ............................................................................................... 143
Chapter 3: Optical Link Design..........................................................................................................145
3.1 DWDM XFP Specifications with GFEC ...................................................................................... 145
3.2 LAD Modules ............................................................................................................................... 146
3.3 Dispersion Compensation Modules.............................................................................................. 151
Chapter 4: Application Configurations .............................................................................................153
4.1 App 1: OC-192/STM-64/10GbE (10G λ) transport ..................................................................... 155
4.1.1 10G Lambda Transport, OEO Application Feature Set ......................................................... 156
4.2 App 2: OC-48/STM-16 Transport ................................................................................................ 158
4.3 App 3: Packet (10GbE and 1GbE) Transport and Switching ....................................................... 159
4.3.1 Protected and Unprotected Configurations ............................................................................ 161
4.4 App 4: Multiservice Lambda Transport, OEO ............................................................................. 162
4.4.1 Multiservice Lambda Transport OEO Application Feature Set ............................................. 163

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 16 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
4.5 App 5: MSE-1482 Transparent Line Functionality ...................................................................... 165
4.6 App 6: MSE-1482 Path Cross-Connect Functionality ................................................................. 167
4.7 App 7: Ethernet over SONET (EoS) ............................................................................................ 168
4.8 App 8: WSS Network Configuration ........................................................................................... 169
4.9 App 9: Ethernet Services and Transport ....................................................................................... 170
4.10 App 10: Collector Rings ............................................................................................................... 171
4.11 App 11: FLX-216i Configurations ............................................................................................... 172
Chapter 5: System Power....................................................................................................................175
5.1 Cyan Z22 Power ........................................................................................................................... 175
5.2 Cyan Z33 Power ........................................................................................................................... 176
5.3 Cyan Z77 Power ........................................................................................................................... 177
5.4 Fuses ............................................................................................................................................. 177
5.5 Z77 Fuse Positions and DC Feeds ................................................................................................ 178
Chapter 6: Management Network Configuration Guidelines..........................................................181
6.1 Single Physical LAN .................................................................................................................... 182
6.2 Multiple Physical LANs ............................................................................................................... 185
6.3 Multiple Physical LANs and the Same IP Sub-Network ............................................................. 192
6.4 Network and Host Routes ............................................................................................................ 198
Appendix A: Best Practices for Network Configurations....................................................................199
Appendix B: Acronyms and Cyan Terminology..................................................................................205

700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 17
Table of Figures
Figure 1: Front and Rear View of the Z22 -48V Shelf Layout ................................................................... 24
Figure 2: Z22 System and Environmental Alarms Connection ................................................................... 27
Figure 3: Z33 Front and Rear Shelf Layout ................................................................................................ 29
Figure 4: CEMi Controller Card ................................................................................................................. 33
Figure 5: CEMi and MSE-1482 Configuration - Traffic via EoS ............................................................... 34
Figure 6: CEMi and MSE-1482 DCN Configuration Option ..................................................................... 34
Figure 7: Z77 Shelf v2 – Front and Rear Views ......................................................................................... 37
Figure 8: L-AMP Shelf – Front View ......................................................................................................... 42
Figure 9: L-AMP Block Diagram ............................................................................................................... 43
Figure 10: Cyan Z22 LAD-2P Module ....................................................................................................... 50
Figure 11: Cyan Z-Series LAD-4A Module ................................................................................................ 50
Figure 12: Cyan Z-Series LAD-8i Module ................................................................................................. 50
Figure 13: Cyan Z-Series LAD-40E Module .............................................................................................. 50
Figure 14: AWG-40 External Module ......................................................................................................... 51
Figure 15: LAD-40E and AWG-40 Installation Example ........................................................................... 51
Figure 16: LAD-2P LGX Passive Module .................................................................................................. 52
Figure 17: LAD-2G LGX Passive Module ................................................................................................. 52
Figure 18: LAD-2P Block Diagram ............................................................................................................ 53
Figure 19: LAD-2G Block Diagram ........................................................................................................... 53
Figure 20: LAD-4 Block Diagram .............................................................................................................. 53
Figure 21: LAD-4A Block Diagram ........................................................................................................... 54
Figure 22: LAD-8 Block Diagram .............................................................................................................. 54
Figure 23: LAD-8i Block Diagram ............................................................................................................. 54
Figure 24: LAD-8A Block Diagram ........................................................................................................... 54
Figure 25: LAD-8E Block Diagram ............................................................................................................ 55

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 18 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
Figure 26: LAD-8X Block Diagram ........................................................................................................... 55
Figure 27: LAD-40 Block Diagram ............................................................................................................ 55
Figure 28: LAD-40E Block Diagram .......................................................................................................... 56
Figure 29: Cyan Z-Series DTM-8 Module .................................................................................................. 61
Figure 30: DTM-8 Functional Block Diagram ............................................................................................ 61
Figure 31: DTM-8G Functional Block Diagram ......................................................................................... 61
Figure 32: Z-Series 2.5G-LME4 Module .................................................................................................... 66
Figure 33: Z-Series 2.5G-LME4 Functional Block Diagram ...................................................................... 66
Figure 34: Z-Series PME-412 Module ........................................................................................................ 69
Figure 35: PME-412 Functional Block Diagram ........................................................................................ 69
Figure 36: Z-Series PME-216i Module ....................................................................................................... 75
Figure 37: PME-216i Functional Block Diagram ....................................................................................... 75
Figure 38: PSW-10G10 Functional Block Diagram ................................................................................... 82
Figure 39: Typical Extended Switch Configuration with PSW-10G10 Line Cards .................................... 82
Figure 40: PSW-618 Functional Block Diagram ........................................................................................ 87
Figure 41: Typical Extended Switch Configuration with PSW-618 Line Cards ........................................ 87
Figure 42: Z77 TSW-10G10 Module .......................................................................................................... 91
Figure 43: TSW-10G10 Configuration Example ........................................................................................ 91
Figure 44: Z77 Aggregation Comparison Using TSW-10G10 Line Cards ................................................. 92
Figure 45: Cyan Z-Series LAC-8 Module ................................................................................................... 94
Figure 46: LAC-8 Block Diagram ............................................................................................................... 94
Figure 47: LAC-4P Wiring Example .......................................................................................................... 97
Figure 48: SFT-8 Module ............................................................................................................................ 98
Figure 49: SFT-8 Module Trunk and Client Interfaces ............................................................................... 98
Figure 50: Z-Series SFT-10G16 Module .................................................................................................. 102
Figure 51: SFT-10G16 Block Diagram ..................................................................................................... 103
Figure 52: Z-Series DTM-100G Transponder Module ............................................................................. 105
Figure 53: DTM-100G Transponder and OTN Functional Block Diagram .............................................. 106
Figure 54: DTM-100G Transponder Block Diagram ................................................................................ 106
Figure 55: Cyan Z-Series MSE-1482 Module ........................................................................................... 110
Figure 56: MSE-1482 Trunk and Client Interfaces ................................................................................... 110
Figure 57: MSE-1482 Any-to-Any Cross-Connect Capabilities ............................................................... 111
Figure 58: MSE-1482 Path (UPSR or SNCP) and Line Protection .......................................................... 112
Figure 59: FLX-216i Trunk and Client Interfaces .................................................................................... 116
Figure 60: WSS-402 and WSS-404 Wavelength Selective Switch Modules ............................................ 120

Cyan Z-Series Engineering and Planning Guide Release 5.0
700-0023-05-00 Rev. 1 © 2013 Cyan, Inc. – All Rights Reserved. Page 19
Figure 61: AWG-40 External Module ....................................................................................................... 121
Figure 62: Z77 Shelf, WSS-402, DTM-8, and AWG-40 Two-Degree Configuration Example ............... 121
Figure 63: WSS-402 AMP Optical RX and TX Paths .............................................................................. 122
Figure 64: OFX-4 Module – External Optical Fabric Cross-Connect ....................................................... 122
Figure 65: WSS-404 Four-Degree Optical Switching ............................................................................... 123
Figure 66: WSS-402 DWDM Diagram ..................................................................................................... 125
Figure 67: Z77 BTM ................................................................................................................................. 131
Figure 68: Ring Closure Module (RCM) .................................................................................................. 135
Figure 69: Z77 with XC-2800 (Rear View) .............................................................................................. 136
Figure 70: Optical protection Group Configuration Example ................................................................... 139
Figure 71: OPS 1+1 Protection ................................................................................................................. 141
Figure 72: Local/Remote Switch on Control Module ............................................................................... 142
Figure 73: LAD-2P Block Diagram .......................................................................................................... 146
Figure 74: LAD-2G Block Diagram ......................................................................................................... 146
Figure 75: LAD-8E Variable Optical Attenuator (VOA) Control Points ................................................. 147
Figure 76: LAD-8X VOA Control Points ................................................................................................. 148
Figure 77: LAD-40E VOA Control Points ................................................................................................ 150
Figure 78: Four-Wave 10G Transport Application with LAD-4/LAD-4A ............................................... 155
Figure 79: Eight-Wave 10G Transport Application with LAD-8/A/E/i/X ................................................ 156
Figure 80: OC-48/STM-16 Transport ....................................................................................................... 158
Figure 81: Application with a Pair of PME Modules – Each PME Supports Two 10 GbE Trunks .......... 159
Figure 82: Z-Series 10G Ring with a Single PME Module ....................................................................... 160
Figure 83: Multiservice Lambda Transport OEO ..................................................................................... 162
Figure 84: Z77 Multiservice Lambda Transport OEO .............................................................................. 163
Figure 85: MSE-1482 Transparent Line Application ................................................................................ 165
Figure 86: MSE-1482 Transparent Line Functionality - Route Diversity ................................................. 166
Figure 87: MSE-1482 Path Cross-Connect Application ........................................................................... 167
Figure 88: MSE-1482 Path Level Capability ............................................................................................ 167
Figure 89: MSE-1482 Ethernet over SONET Application ........................................................................ 168
Figure 90: WSS-402 Network Configuration / Regeneration ................................................................... 169
Figure 91: Z22 - Aggregation, Transport, and Edge Access ..................................................................... 170
Figure 92: Z22, Z33, and Z77 Collector Rings ......................................................................................... 171
Figure 93: Z22 Collector Ring Node Configuration ................................................................................. 171
Figure 94: FLX-216i Point-to-Point Configuration .................................................................................. 172
Figure 95: FLX-216i Ring Topology, Single-Card Configuration............................................................ 172

Cyan Z-Series Engineering and Planning Guide Release 5.0
Page 20 © 2013 Cyan, Inc. – All Rights Reserved. 700-0023-05-00 Rev. 1
Figure 96: FLX-216i Ring Topology, Two-Card Configuration .............................................................. 173
Figure 97: Z77 Fuse Assignment for Fan Module .................................................................................... 178
Figure 98: Z77 Shelf Fuse Assignment for Fan Modules ......................................................................... 179
Figure 99: Single Physical LAN Example ................................................................................................ 182
Figure 100: Collocated Planet Operate Server Example ........................................................................... 183
Figure 101: Non-Collated Planet Operate Server Example....................................................................... 184
Figure 102: Multiple Physical LANs Example ......................................................................................... 185
Figure 103: Collocated Planet Operate Server Sharing Same LAN as the Gateway Cyan Node ............. 186
Figure 104: Collocated Planet Operate Server with Redundant Cyan Gateway Nodes ............................ 187
Figure 105: Non-Collocated Planet Operate Server and Gateway Node Separated by One or More Routers . 188
Figure 106: Non-Collocated Planet Operate Server with Redundant Cyan Gateway Nodes .................... 190
Figure 107: Collocated Planet Operate Server and Cyan Nodes ............................................................... 192
Figure 108: Collocated Planet Operate Server with Redundant Cyan Gateway Nodes ............................ 194
Figure 109: Non-Collocated Planet Operate Server and Cyan Nodes Separated by a Router .................. 195
Figure 110: Non-Collocated Planet Operate Server with Redundant Cyan Gateway Nodes .................... 197
Figure 111: Linear Chain – Slot and Line Card Assignments ................................................................... 201
Figure 112: Typical Z33 and Z77 Ring Configuration ............................................................................. 202
Figure 113: Ring Configuration with WSS-402 Cards Only in a Node Site ............................................. 203
This manual suits for next models
4
Table of contents