4. Troubleshooting 
Item NG point NGAnalyzing solution 
Charge 
Triggering 
System 
 Charging failure 1>. Check if connectors TP45-TP50 of J401 are 
cold solder, no solder, insufficient solder, 
short-circuit, wrong solder, and etc. if there is 
any, remove the abnormity; 
2>. If (1) is normal, check if U401 and related 
components and voltage are normal, remove 
the abnormity; 
3>. If (1), (2) are normal, check if Q402 and 
T401 are normal, remove the abnormity; 
4>. If (1), (2), (3), check if D401, R401~R406 
and big capacitor are normal, remove the 
abnormity; 
5>. If above are normal, check if controlled pins 
of MCU board are normal, remove the 
abnormity. 
 Triggering failure/ 
flash missing/ flash 
only once 
1>. Check if tube is offset or installed reversely, 
wires of tube are cold solder or insufficient 
solder, remove the abnormity; 
2>. If (1) is normal, check if copper foil of 
reflector contact well; 
3>. If (1), (2) are normal, check if big capacitor 
is insufficient solder and voltage is normal. If 
voltage is too low, check if R401~R406 are 
normal, remove the abnormity; 
4>. If (1), (2), (3) are normal, check if Q403 is 
triggered, cold solder or insufficient solder, 
C505 is cold solder or broken, remove the 
abnormity; 
5>. If (1), (2), (3), (4) are normal, check if +5V 
voltage is normal, remove the abnormity; 
6>. If above items are normal, check controlled 
pins on MCU board are normal, removes the 
abnormity. 
Lens 
system Lens flexing issue 1>. Check if connecting board of lens is NG, 
cold solder or insufficient solder, remove the 
abnormity; 
2>. If (1) is normal, check if R84, R87, R89, R90 
on MCU board are cold solder or insufficient 
solder, remove the abnormity; 
3>. If (1), (2) are normal, check if CN1 and CN2 
contact well, remove the abnormity; 
4>. If above items are normal, check if U8 and 
related circuit are cold solder or insufficient 
solder, remove the abnormity.