Table of contents
Installer reference guide
3
ERGA04~08E + EHVZ04+08S18+23E
Daikin Altherma 3 R F
4P629093-1B – 2022.05
7.2.4 To open the indoor unit ................................................................................................................................. 58
7.2.5 To lower the switch box on the indoor unit .................................................................................................. 60
7.2.6 To close the indoor unit ................................................................................................................................. 61
7.3 Mounting the outdoor unit............................................................................................................................................. 61
7.3.1 About mounting the outdoor unit ................................................................................................................. 61
7.3.2 Precautions when mounting the outdoor unit.............................................................................................. 61
7.3.3 To provide the installation structure ............................................................................................................. 61
7.3.4 To install the outdoor unit ............................................................................................................................. 64
7.3.5 To provide drainage........................................................................................................................................ 65
7.3.6 To prevent the outdoor unit from falling over .............................................................................................. 67
7.4 Mounting the indoor unit ............................................................................................................................................... 68
7.4.1 About mounting the indoor unit.................................................................................................................... 68
7.4.2 Precautions when mounting the indoor unit................................................................................................. 68
7.4.3 To install the indoor unit ................................................................................................................................ 68
7.4.4 To connect the drain hose to the drain ......................................................................................................... 69
8 Piping installation 70
8.1 Preparing refrigerant piping ........................................................................................................................................... 70
8.1.1 Refrigerant piping requirements.................................................................................................................... 70
8.1.2 Refrigerant piping insulation.......................................................................................................................... 71
8.2 Connecting the refrigerant piping .................................................................................................................................. 71
8.2.1 About connecting the refrigerant piping ....................................................................................................... 71
8.2.2 Precautions when connecting the refrigerant piping.................................................................................... 72
8.2.3 Guidelines when connecting the refrigerant piping...................................................................................... 73
8.2.4 Pipe bending guidelines ................................................................................................................................. 73
8.2.5 To flare the pipe end ...................................................................................................................................... 73
8.2.6 To braze the pipe end..................................................................................................................................... 74
8.2.7 Using the stop valve and service port............................................................................................................ 75
8.2.8 To connect the refrigerant piping to the outdoor unit ................................................................................. 76
8.2.9 To connect the refrigerant piping to the indoor unit .................................................................................... 77
8.3 Checking the refrigerant piping...................................................................................................................................... 77
8.3.1 About checking the refrigerant piping........................................................................................................... 77
8.3.2 Precautions when checking the refrigerant piping........................................................................................ 78
8.3.3 To check for leaks ........................................................................................................................................... 78
8.3.4 To perform vacuum drying............................................................................................................................. 79
8.3.5 To insulate the refrigerant piping .................................................................................................................. 80
8.4 Charging refrigerant........................................................................................................................................................ 80
8.4.1 About charging refrigerant............................................................................................................................. 80
8.4.2 Precautions when charging refrigerant ......................................................................................................... 81
8.4.3 To determine the additional refrigerant amount.......................................................................................... 81
8.4.4 To determine the complete recharge amount.............................................................................................. 82
8.4.5 To charge additional refrigerant .................................................................................................................... 82
8.4.6 To fix the fluorinated greenhouse gases label............................................................................................... 82
8.5 Preparing water piping ................................................................................................................................................... 83
8.5.1 Water circuit requirements............................................................................................................................ 83
8.5.2 Formula to calculate the expansion vessel pre-pressure.............................................................................. 86
8.5.3 To check the water volume and flow rate ..................................................................................................... 86
8.5.4 Changing the pre-pressure of the expansion vessel...................................................................................... 88
8.5.5 To check the water volume: Examples .......................................................................................................... 89
8.6 Connecting water piping................................................................................................................................................. 89
8.6.1 About connecting the water piping ............................................................................................................... 89
8.6.2 Precautions when connecting the water piping............................................................................................ 90
8.6.3 To connect the water piping .......................................................................................................................... 90
8.6.4 To connect the recirculation piping ............................................................................................................... 92
8.6.5 To fill the water circuit ................................................................................................................................... 92
8.6.6 To fill the domestic hot water tank................................................................................................................ 92
8.6.7 To insulate the water piping .......................................................................................................................... 93
9 Electrical installation 94
9.1 About connecting the electrical wiring .......................................................................................................................... 94
9.1.1 Precautions when connecting the electrical wiring....................................................................................... 95
9.1.2 Guidelines when connecting the electrical wiring......................................................................................... 95
9.1.3 Specifications of standard wiring components.............................................................................................. 97
9.1.4 About electrical compliance........................................................................................................................... 97
9.1.5 About preferential kWh rate power supply................................................................................................... 97
9.1.6 Overview of electrical connections except external actuators ..................................................................... 98
9.2 Connections to the outdoor unit.................................................................................................................................... 98
9.2.1 To connect the electrical wiring to the outdoor unit .................................................................................... 98
9.3 Connections to the indoor unit ...................................................................................................................................... 100
9.3.1 To connect the main power supply................................................................................................................ 103