Operation manual
7
EKHVH/X008BB6V3 + EKHVH/X008BB6+9WN
Daikin Altherma indoor unit
4PW64330-1 – 07.2010
Selection and setting of domestic water heating (w)
1Use the vbutton to activate the programmed storage and
re-heat domestic water heating (w).
Icon wappears on the display.
2Use the wi or wj button to display the actual storage
temperature set point and subsequently, to set the correct
temperature.
The actual storage temperature set point only appears on the
display after pressing one of the buttons wi or wj. If no
button is pressed for 5 seconds, the temperature set point will
automatically disappear from the display again.
Temperature range for domestic water heating: 30°C to 60°C
3Press the vbutton to deactivate the programmed storage
and re-heat domestic water heating (w).
Icon wdisappears from the display.
Selecting powerful domestic water heating operation
1Press vfor 5 seconds to activate powerful domestic water
heating operation.
Icons wand )start flashing.
Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.
Selecting quiet mode operation (s)
1Use the sbutton to activate quiet mode operation (s).
Icon sappears on the display.
If the controller is set in permission level 2 or 3 (refer to "Field
settings" on page 12), the sbutton will not be operable.
Selecting weather dependent set point operation (only in
heating mode)
1Press the ba button to select weather dependent set point
operation.
Icon aappears on the display as well as the calculated weather
dependent set point.
The actual shift value only appears on the display after pressing
one of the buttons bi or bj. If no button is pressed for 5
seconds, the shift value will automatically disappear and the
calculated weather dependent setpoint is displayed again.
2Use the bi and bj buttons to set the shift value.
Range for the shift value: –5°C to +5°C
Displaying actual temperatures
1Push the ba button for 5 seconds.
The bicon and the outgoing water temperature are displayed.
The icons land =are flashing.
2Use the pi and pj buttons to display:
If no button is pressed for 5 seconds, the controller leaves the
display mode.
Schedule timer operation
In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.
The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to "Manual operation" on page 6). The schedule timer will regain
control over the installation as soon as the next programmed
command of the schedule timer occurs.
The schedule timer is enabled (picon displayed) or disabled (picon
not displayed), by pressing the pr button.
To set up the SCHEDULE TIMER refer to chapter "Programming and
consulting the schedule timer" on page 8.
What can the schedule timer do?
The schedule timer allows the programming of:
1. Space heating (refer to "Programming space heating or
domestic water heating" on page 9)
Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set).
Four actions per weekday can be programmed, totalling
28 actions.
2. Space cooling (refer to "Programming space cooling or quiet
mode" on page 10).
Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Four
actions can be programmed. These actions are repeated daily.
3. Quiet mode (refer to "Programming space cooling or quiet
mode" on page 10)
Switch the mode on or off at a scheduled time. Four actions can
be programmed per mode. These actions are repeated daily.
Remark that pushing the ybutton has no influence on
the domestic water heating. Domestic water heating is only
switched on or off by means of the vbutton.
Flashing icon(s) Meaning
hor cThe entering water temperature
hor cand éThe outgoing water temperature after plate heat
exchanger
hor cand )The outgoing water temperature after backup
heater
uThe outdoor temperature
wThe domestic hot water temperature
■Only use the pr button to enable or disable the
schedule timer. The schedule timer overrules the y
button. The ybutton only overrules the schedule
timer until the next programmed action.
■If the auto restart function is disabled, the schedule
timer will not be activated when power returns to the
unit after a power supply failure. Press the pr button
to enable the schedule timer again.
■When power returns after a power supply failure, the
auto restart function reapplies the user interface
settings at the time of the power supply failure.
It is therefore recommended to leave the auto restart
function enabled.
■The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to "Setting the clock" on page 5.
■Manually adjust the clock for summertime and
wintertime. Refer to "Setting the clock" on page 5.
■A power failure exceeding 2 hours will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to "Setting the clock" on page 5 to adjust the clock and
the day of the week.
■The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.
When the unit is connected to an external room
thermostat, the schedule timer for space heating and
space cooling is overruled by the external room
thermostat.