Dali IRTECH C Series User manual

www.dali-irtech.com
C-series pocket thermal camera
User manual
Copyright © 2022 DALI TECHNOLOGY

2
! Warnings, cautions and notes
Definition
Warning Represents a dangerous situation or act that may result in
personal injury or death.
Caution Represents a situation or action that could result in damage to the
camera or permanent loss of data.
NOTE Indicates a useful hint for the user.
Important information –Please read before using the instrument
Caution –As the camera uses a very sensitive thermal sensor, the lens must
not be pointed directly at a strong source of radiation (e.g. sun, direct laser
beam or reflection) under any circumstances (on or off) as this will cause
permanent damage to the camera!
Caution - The camera must be transported in its original box and must not be
shaken or bumped strongly during use or transport.
Caution –It is recommended that the camera be stored in its original case in a
cool, dry, ventilated environment free from strong electromagnetic fields.
Caution - Avoid staining the surface of the lens with oil and various chemicals
and damaging the surface. Close the lens cap after use.
Caution - To prevent the potential risk of data loss, always copy (back up) data
to your computer.

3
NOTE - The camera may require a 3-5 minute warm-up process before
accurate readings can be taken.
NOTE - Every thermal imaging camera is factory calibrated for temperature
and it is recommended that this be done annually.
Caution - Do not open the case or make modifications without permission,
repairs should only be carried out by authorized personnel.
CONTENTS
! Warnings, cautions and notes............................................................... 2
1Introduction .................................................................................. 5
1.1 Standard configuration...............................................................................................6
2Thermal camera introduction............................................................ 7
2.1 Key function...................................................................................................................7
2.2 Interface..........................................................................................................................8
3Basic operation .............................................................................. 8
3.1 The battery cannot be replaced...............................................................................8
3.2 Quick Start......................................................................................................................8
3.2.1 Obtaining thermal images.................................................................................8
3.2.2 Temperature measurement ...............................................................................8

4
3.2.3 Image storage .......................................................................................................9
3.2.4 Image playback.....................................................................................................9
3.2.5 Image export.........................................................................................................9
3.2.6 LCD settings.........................................................................................................10
3.2.7 Menu Operation Description ..........................................................................10
4Operation guide ........................................................................... 10
4.1 Operation Interface Description ............................................................................10
4.1.1 User interface of working state ......................................................................10
4.1.2 Drop-down menu...............................................................................................12
4.1.3 Main menu...........................................................................................................12
4.2 Temperature Measurement Mode.........................................................................13
4.3 Color code switching.................................................................................................13
4.4 Image adjustment......................................................................................................14
4.5 Image Storage.............................................................................................................15
4.6 Image playback...........................................................................................................15
4.7 System Settings ..........................................................................................................16
4.7.1 Temperature Measurement Parameters Settings ......................................16
4.7.2 Temperature measurement settings.............................................................17
4.7.3 Network Settings................................................................................................18
4.7.4 Storage settings..................................................................................................19
4.7.5 Alarm Settings.....................................................................................................19
4.7.6 Device Settings ...................................................................................................20

5
4.7.7 System Information ...........................................................................................21
5RFQ ............................................................................................ 22
Appendix A ....................................................................................... 23
Emissivity of common materials (for reference only)...................................................23
1Introduction
Thank you for choosing C16/C25 series pocket Thermal Imaging Camera from
Zhejiang Dali Technology Co.,Ltd.
Main features
Measurement of maximum temperature, minimum temperature and
multiple movable points
Multiple movable area temperature measurement
Arbitrary line temperature measurement
6 color codes to choose
Infrared and visible image fusion
Temperature setting
Focus free
3.5-inch color LCD touch screen
Adjustable LCD brightness
LED fill light
WiFi wireless network
Gravity sensor
Enhanced Mode
Multiple language options

6
Applications:
Preventive maintenance
Electric power industry: thermal state inspection of transmission lines and
power equipment, fault diagnosis.
Electrical system: Identifies circuit overloads in advance before they
happen.
Mechanical system: reduce downtime and prevent failure.
Building science
Roof: Detect water leakage quickly and efficiently.
Building structure: Infrared energy assessment survey for commercial
buildings and residential buildings.
Moisture detection: finds the root of dampness and mildew.
Remediation: Evaluate remedies and make sure the area is completely dry.
Other applications
Iron and steel industry: monitoring the process of steel-making and
rolling, diagnosing the damage of hot blast stove, detecting the temperature of
sheet and embryo.
Fire protection: forest fire prevention and potential fire source search,
special materials spontaneous combustion prevention and testing, electrical fire
safety testing.
Medical: human body surface temperature detection and temperature
field distribution analysis.
Petrochemical industry: oil pipeline status inspection, material interface
inspection, heat leakage and insulation structure, power equipment status
inspection, etc.
1.1 Standard configuration
Pocket thermal camera
TYPE-C data cable
Packaging box
Certificate

7
2Thermal camera introduction
2.1 Key function
[1] power key
Used for thermal imager on and off, standby and wake up. Press this switch for
more than three seconds to start/close the thermal imager; Short press to enter
standby/wake up (any other key can also wake up).
! Note: After power off, it is recommended to wait at least ten seconds before
starting up again to ensure the safety of the thermal imager.

8
2.2 Interface
[3] USB
For data transfer and charging
[4]Indicator
For charging indication
3Basic operation
3.1 The battery cannot be replaced
3.2 Quick Start
3.2.1 Obtaining thermal images
Long press the power key (more than 3 seconds) until the power light
turns green. About 10 seconds later, the device is initialized and enters
the working state.
The thermal imager is free of focusing and can make the target image
clear without focusing operation.
3.2.2 Temperature measurement
Move the cross temperature measuring point on the screen to the target
object, and the "XX" displayed in the upper left corner of the screen is the
temperature of the target.
When the target temperature is greater or less than the upper or lower

9
limit of the temperature measured by the thermal imager, the screen
temperature will display > XXX℃or < XXX℃to prompt the user.
Menu for setting temperature measurement area properties
Click to select the temperature measuring point, temperature
measuring area and temperature measuring line, and drag the whole
temperature measuring object. You can drag the angle of the temperature
measurement area by holding down any point of the four corners of the
area to change the size of the area. Hold down a section of the
temperature line for extension.
3.2.3 Image storage
To store the current image, you can choose the following methods.
Click the button on the screen, and then click to take photos for
storage.
3.2.4 Image playback
Click the playback button to pop up the image library and select the
folder to play back the image.
3.2.5 Image export
USB data cable can be used to connect the computer to operate the stored
data in the thermal imager, including image export, deletion, formatting
and other operations.

10
3.2.6 LCD settings
You can adjust the screen brightness by exhaling the drop-down menu and
sliding the brightness.
3.2.7 Menu Operation Description
Touch screen operation:
Click the icon at the bottom right of the touch screen and click each icon
to perform corresponding operations. Enter the setting menu, click the
menu item to set, enter the sub-menu of the next level, the last level
menu for function switch, parameter setting, option selection and other
operations; Click the arrow before the interface name to return to the
previous menu.
Click the touch screen drop-down shortcut menu to switch on and off
WiFi and LED lights. Click the clear screen icon to clear the main interface
UI, lock screen, and adjust the brightness.
4Operation guide
4.1 Operation Interface Description
4.1.1 User interface of working state
1
2
3
4
6
7
8

11
User interface of working state of thermal imager
[1] Temperature unit: A unit of temperature
[2] Upper limit temperature: upper limit temperature value of color label.
[3] Temperature color code: the color bar of the current image display
[4] Lower limit temperature: lower limit temperature value of color label.
[5] Temperature measurement object: you can choose point temperature
measurement, line temperature measurement, region temperature measurement.
[6] Menu buttons: the menu includes Settings, mode selection, color code
selection, temperature measurement object selection, etc
[7] Storage button: it can take photos and store.
[8] Playback button: You can view stored photos.
5

12
4.1.2 Drop-down menu
Drop-down menu interface
Drop-down menu interface: Click the corresponding icon to turn on/off WIFI,
LED fill light, clear screen, lock screen. Adjust screen brightness by sliding.
4.1.3 Main menu
Main menu interface
Main menu interface: The ICONS of the main menu on the right are image
playback, photo saving and menu button in sequence.

13
4.2 Temperature Measurement Mode
Add or delete a temperature measurement object, including a temperature
measurement point, temperature measurement area, and temperature
measurement line.
Tap the touch screen. Click the temperature measurement mode icon on
the touch screen, and the following interface appears.
Temperature measurement mode interface
Click the ICONS of temperature measurement objects such as temperature
measurement point, temperature measurement area, and temperature
measurement line on the touch screen to add temperature measurement objects
such as temperature measurement point, temperature measurement area, and
temperature measurement line on the screen. Click the delete icon on the far
right to clear all the added temperature objects.
4.3 Color code switching
This function is used to select the color code of the image display. There are
six color codes to choose from.
Click the touch screen to pop up the main menu. Click the color label on
the touch screen to pop up the following interface.

14
Color code switching interface
According to the display requirements of the target scene, directly click the
corresponding color bar on the touch screen to switch to the selected color bar.
4.4 Image adjustment
This function is used for manual/automatic mode selection of image
adjustment.
Click on the touch screen to pop up the main menu. Click on the touch screen
to pop up the ICONS of automatic /manual mode as shown below. Click the
mode icon to select, and switch to the selected mode.
To adjust the mode manually, click to select the upper and lower temperature
values of the color label and slide your finger on the right side of the color label to
adjust the upper and lower temperature values of the color label separately or
simultaneously. Click the selected temperature value again to deselect it.

15
Image adjustment interface
4.5 Image Storage
This feature is used to save images in JPG format.
Tap the touch screen and tap the photo icon . Click on the touch screen
to save the current image directly.
Photo interface
4.6 Image playback
This function is used to browse and play back the saved image file.
Click the playback icon on the touch screen to pop up the picture library
interface, as shown below. Click the corresponding folder to open the folder, click
the icon to delete the folder.

16
Photo gallery interface
4.7 System Settings
This function is used to set various parameters of thermal imager, including
temperature measurement parameter setting, temperature measurement function
setting, network setting, storage setting, alarm setting, device setting, etc.
Click the touch screen to pop up the main menu. Click the setting icon on
the touch screen to pop up the system setting menu interface, as shown below.
System Setting interface
4.7.1 Temperature Measurement Parameters Settings
In the temperature measurement parameter setting menu, there are
temperature measurement gear setting, specific emissivity setting, ambient
temperature setting, background temperature setting, humidity setting,
temperature measurement distance setting, and temperature correction setting.

17
Temperature measurement parameter setting menu
Temperature measurement gear setting: The temperature gear can be switched.
Radiation coefficient setting: You can select the emissivity value of the target
through the touch screen.
Ambient temperature setting: You can select the ambient temperature by
touching the screen.
Background temperature setting: You can select the desired background
temperature value by touching the screen.
Humidity setting: You can select the relative humidity of the environment
through the touch screen.
Distance setting: You can select the distance of the target by touching the screen.
Temperature correction : You can select the required correction temperature
value by touching the screen.
4.7.2 Temperature measurement settings
In the temperature measurement setting menu, there are automatic zero
adjustment interval, automatic enhancement mode, high and low temperature
point settings of temperature measurement line and temperature measurement
area.

18
Temperature measurement setting menu
Auto-zero interval: You can select the time interval to be zero-adjusted by
touching the screen.
Auto Enhance Mode: On/Off can be selected via touch screen.
High and low temperature points of the temperature measurement line: You
can set the display conditions of the high and low temperature points.
High and low temperature points in the temperature measurement area: You
can set the display conditions of the high and low temperature points.
4.7.3 Network Settings
In the network settings menu, WIFI settings can be performed.
Network settings menu
WIFI setting: You can turn on/off WIFI through the touch screen. The default
password of WIFI is 12345678, which can be connected through the mobile APP
and realize remote monitoring and other functions.

19
4.7.4 Storage settings
In the storage settings menu, there are image storage format settings,
memory card capacity display, and format settings.
Storage settings menu
Image storage settings: You can set a separate JPG format, or you can set an
associated visible light format.
Memory Card Capacity: Displays the available memory capacity.
Format: You can format the memory card.
4.7.5 Alarm Settings
In the alarm setting menu, there are temperature alarm mode, high and low
temperature alarm settings, alarm temperature settings, alarm linkage interval
settings, and alarm buzzer settings.

20
Alarm Settings Menu
Temperature alarm mode: On/off can be selected by touch screen.
Alarm type: High /low temperature alarm can be selected by touch screen.
Alarm temperature: The alarm temperature threshold can be selected through
the touch screen.
Alarm linkage interval: The alarm linkage interval can be selected by touching
the screen.
Alarm buzzer: Alarm buzzer on/off can be selected by touch screen.
4.7.6 Device Settings
In the device settings menu, there are language and time settings, brightness
settings, shutdown time settings, sleep time settings, screen rotation lock settings,
color code bar display settings, update and upgrade settings, and restore factory
settings.
Image settings menu
Table of contents