DALRC QUHF User manual

1
DALRC
QUHF 433 MHZ Operating Manual

2
GND=These 3 GND pins are all common ground.
VCC=transmitter power supply input (support 2s-6s, 3s recommended)
P/S=PPM or SBUS signal input (PPM and SBUS signal will be
identified automatically)
5V=5Voutput (power supply receiver)
1=Channel 1 PWM input (if PPM2 was turn on then PPM2
input via this pin)
2=Channel 2 PMW input
3=Channel 3 PMW input
4=Channel 4 PMW input

3
TX/5=Channel 5 PMW input (when upgrading connect USB to TT
L ’s RX)
RX/6=Channel 6 PMW input (when upgrading connect USB to TT
L ’s TX)
7==Channel 7 PMW input
8==Channel 8 PMW input
Ground wire=These 10 GND pins are all common ground on receiver.
5V=Receiver 5V power supply input (support 3.3v-8v power suppl
y, 5v recommended)
Channel 1=Channel 1 PWM output
Channel 2=Channel 2 PWM output
Channel 3=Channel 3 PWM output
Channel 4=Channel 4 PWM output
Channel 5=Channel 5 PWM output

4
Channel 6=Channel 6 PWM output
Channel 7=Channel 7 PWM output
Channel 8=Channel 8 PWM output
Channel 9=RSSI output (Capable to set output mode)
Channel 10=PPM output (Capable to set output mode)
Above each pin’s function was defaulted by receiver, which is capa
ble to reset to change its function, For example , set the channel
10 to SBUS output, details of setting process please refer the functi
on diagram.
Note :To keep the 433 signal on the best condition, we recommend
setting the transmitter and receiver’s antenna vertical to the ground
,the receiver’s antenna can be set up by using a plastic beverage
straw or a chopstick (Do not using the carbon stick or any metal r
elated sticks)
Setting process of common used function
Note: Before frequency binding or setting fail-safe transmitter must
be accessed in one of PPM,PWM or SBUS signal successfully.
(1) Single receiver’s frequency binding process: keep press receiver’s
button until blue light flashing release it, then power supply to rec
eiver (when transmitter’s blue light stop flashing, receiver’s red lig
ht on, frequency binding success )

5
(2) Lost control protection setting process: Set all the channel of re
mote controller to the position where the receiver was expected to
output the proper signal during the lost control condition, then keep
press the button until the red light start flashing to release it,
power supply to the receiver(transmitter’s red light stop flashing
and receiver’s red light on means set success, Note:before set lost
control protection the frequency binding must be finished successfull
y )
(3) Multiple receivers frequency binding process: Follow the “(1)Sin
gle receiver’s frequency binding process” binding the first receiver’s
frequency. The second one or more than two receivers please refer
following process.
Keep press the transmitter’s button until purple light flashing rel
ease it, then power supply to receiver (when transmitter’s purple lig
ht stop flashing ,frequency binding success )
Transmitter restore to default setting: keep click the button
9 times and wait for instruction, once red light rapidly flashing pr
ess button 1s more, release the button after the red light and blue l
ight start flashing alternately , restore success.
DALRC 433Mhz Transmitter Setup

6
Continuously click the button on the Transmitter “N” times on
standby mode condition system will enter into the corresponding f
unction setting.
•For example: we want to set the transmitting power to (1500mW)
1.5W, only need to click the function button 3 times, then flashes 3 times
purple light (the purple light flashing times are same with the times you
click the button) after that, coming to red light or blue light flashing (if
the blue light intermittent flashed 4 times that mean the current power is
1000mW(1wM)), when need to change the power just click the function
button which will switch to next step setting, intermittent flashed 5 times
red light means 1500mW), by this time in order to save the current setting
you need to press the function button 1s more, red light and blue light
alternately flash 2 times means saving success, automatically restart.
After function 5-8 set finished, transmitter need to reenter
frequency binding mode,(transmitter needs transfer the set parameter to
receiver), then power supply to receiver will finish frequency binding .
(all the setting will be saved permanently unless Restore factory setting or
reset it deliberately) the following is function diagram.

7
Continuously
click button
frequency
Menu
Indicator flash
frequency and
color
Corresponding
function
Description
1
Transmitting
power switch
Blue light 3
times
Low power Low power is 300mw,
available switch to
100-1500mw ,
(Continuously click
button 3 times will
switch) defaulted is
1000mw
Red light 3 times
User defined
power
2
Signal input
mode
selection
Blue light 1 time
(default)
SBUS or PPM or
PWM input mode
(the 3 sorts
signal identific
ation
automatically)
If inputted signal is
SBUS, then 16
channels can be
contain directly
Red light 2 times
Double PPM
input
mode(PPM2
channel
will identificatio
n automatically)
Head tracking input
was suggested this
mode (If this mode can
not identifying
proper
ly then select
below double ppm
mode )
Blue light 3
times
Double PPM
input
mode(channel 7
and 8 acquired
from PPM2
signal, channel
1,2,3,4,5,6
acquired from
PPM1signal )

8
2 Signal
input mode
selection
Red light 4 times
Double PPM
input
mode(channel 5
and 6 acquired
from PPM2
signal, channel
1,2,3,4,7,8
acquired from
PPM1signal)
PPM1 corresponding
with transmitter ‘s
“P/S”
input pin,
PPM2 corresponding
transmitter’
s channel
“1” input pin
Blue light 5 times
Double PPM
input
mode(channel 3
and 4 acquired
from PPM2
signal, channel
1,2,5,6,7,8
acquired from
PPM1 signal)
Red light 6 times
Double PPM
input
mode(channel 1
and 2 acquired
from PPM2
signal, channel
3,4,5,6,7,8
acquired from
PPM1 signal)
Blue light 7 times
16 channel
mode(channel
1-8 inputted from
p/s In , channel
9-
16 inputted
from PPM2)
16 channel model can
be directly with a
receiver SBUS
contains 16 channels
2 receivers can be also
used working
together ,set one of
receiver output 1-8
channel signal or

9
Red light 8 times
16 channel
mode(channel 1-8
input from p/s
In,channel 9-16
input from
PPM1-PWm8 port)
Output 9-16
channel signal
(both of 2
receivers’ lost
control protection
can be set
independent and
running, without
interfere each
other. )
3 Transmitting
power
adjustment
Blue light 1 time 100mw
The greater the
power, the greater
the heat on
transmitter
Blue light 2 times 300mw
Blue light 3 times 700mw
Blue light 4 times
(default)
1000mw
Red light 5 times 1500mw
4 Receiver
output mode
setting
Blue light 1 times
(default)
Receiver’
s channel
1-
8 output PWM,
channel 9 output
RSSI, channel 10
output PPM
This 6 items set is
for set up
receiver’
s output
mode, keep press
the saving button
after receiver was
set to
corresponding
mode, by this time
receiver will flash
purple light enter
to frequency
binding mode,
then power supply
to receiver,
transmitter will
transmit the
Blue light 2 times
Receiver’
s channel
1-
8 output PWM,
channel 9 output
RSSI, channel 10
output SBUS
Blue light 3 times Receiver’
s channel
1-
8 output PWM,
channel 9 output
PPM, channel 10
output SBUS

10
4 Blue light 4 times Receiver’
s channel
1-10 output PWM
set parameters to
receiver, once set
up success
transmitter ‘s
indicator light will
stop flashing
(receiver
outputted SBUS
signal contain 16
channels)
Blue light 5 times Receiver’
s channel
1-8 output 9-16
channel ‘
s PWM,
channel 9 output
RSSI, channel 10
output PPM
Blue light 6 times Receiver’
s channel
1-8 output 9-16
channel ‘
s PWM,
channel 9 output
RSSI, channel 10
output SBUS
5 Data
package
transmitting
frequency
set
Red light 1 time
20Hz (transmitting
20 times data
package per
second) [9600bps]
Reduce this value
distance will be
further, but with
too lower value to
operate the remote
controller will
make the servo
not smooth
(normal remote
controller’s output
won’
t beyond
50HZ(except high
speed SBUS), so
unless flying
helicopter or
mul
tirotor racing
need smoother
operate feeling
otherwise keep
within 50HZ )
Blue light 2 times
35Hz (transmitting
35 times data
package per
second)[19200bps]
Blue light 3 times
(default)
50Hz (transmitting
50 times data
package per
second)[57600bps]
Red light 4 times
100Hz (transmitting
50 times data
package per
second)[125000bps]

11
6 Frequency
hopping
points set
Blue light 1 time
(default)
Random
generated 6
Frequency
hopping points
Keep in default
mode for general
case, the quantity
of frequency
hopping points is
how many
frequency hopping
points can be
divided from the
frequency range
400Mhz-470Mhz
to hopping ,the
more frequency
hopping points the
lower rate to be
interfered,
meanwhile the
higher rate around
device be
interfered.
Blue light 2 times
Random
generated 12
Frequency
hopping points
Blue light 3 times
Random
generated 18
Frequency
hopping points
Red light 4 times Random
generated 24
Frequency
hopping points
7 Frequency
hopping
gap
Red light 1 time 1KHZ
Keep in default
mode for general
case, here is to set
frequency gap
between frequency
hopping points .
Red light 2 times 2KHZ

12
7 Blue light 3 times 3KHZ
Blue light 4 times 4KHZ
Blue light 5 times
(default)
5KHZ
Blue light 6 times 6KHZ
Blue light 7 times 7KHZ
Red light 8 times 8KHZ
Red light 9 times 9KHZ
Red light 10 times 10KHZ
8 Relaying
mode
Blue light 1 time Mode 1
Default relaying
mode is off
state ,when need to
use the relaying
mode all the
transmitter must be
set
up in same
relaying mode.
Note: replaying
mode must be
the final one to
set,if transmitter
has set other
parameters, the
replaying mode
will off
automatically,you
must reset relaying
mode again
(including reset
replaying mode
after frequency
binding )
Red light 2 times Mode 2
Blue light 3 times Mode 3
Red light 4 times Mode 4
Blue light 5 times Mode 5
Red light 6 times Mode 6
Blue light 7 times Mode 7
Red light 8 times Mode 8
Blue light 9 times Mode 9
Red light 10 times Mode 10

13
Firmware upgrade connecting diagram:
QUHF transmit, receive support online upgrade software,
needing computer accessed into internet.
9
Restore Factory
Defaults
Red light 1 time
Set the
transmitter to
restore Factory
Default.
After restore
Factory Defaults
all the settings will
be reset to default

14
Transmitter enter into upgrade mode setting : connecting the
upgrade module with transmitter, keep press the setting button, connect
power, release the button after transmitter indicator light rapidly flashing
in red with blue and to enter in upgrade mode, connect with computer
afterwards.
Receiver enter into upgrade mode setting: connecting the
upgrade module with receiver , linked channel 7 and channel 8 ‘s signal
wire,plug in computer to enter in upgrade mode, then cancel the linking
between channel 7 and channel 8.
Software operation: While plug in QUHF device, after select
the correct COM from COM Port ,QUHF device will connected
automatically (check the COM Port from the device manager), then
select the firmware from the choice box which is below the software and
click start upgrade firmware ,after upgrading finished QUHF will restart,
pull out the upgrade module.
Table of contents
Popular Extender manuals by other brands

Dutypoint
Dutypoint VR2 Operation and maintenance manual

WaveSplitter
WaveSplitter WST-PEX007 Operation manual

StarTech.com
StarTech.com SV565UTPUL instruction manual

Conductive Labs
Conductive Labs MRCC XpandR 4x1 user guide

NETGEAR
NETGEAR WN3100RP Installation

Widearea Telecommunication
Widearea Telecommunication AER800-8P installation manual