03/2015 VUCUA212 Danfoss Floor Heating Hydronics 3
The function consists of 2 programs:
P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.) P2 with 4 events in 2 days (Sat. Sun.).
P1: Press to display Mo. Tu. We. Th. Fr.
P1, Event 1:
1. Use <or >to select the start time.
2. Press to accept the setting.
3. Use <or >to select the temperature.
4. Press to accept the setting.
P1, Event 2-4:
Repeat the Event 1 procedure for programming
Event 2-4.
P2: Sa. Su. are now shown in the display.
P2, Event 1:
1. Use <or >to select the start time.
2. Press to accept the setting.
3. Use <or >to select the temperature.
4. Press to accept the setting.
P2, Event 2-4:
Repeat the Event 1 procedure for programming
Event 2-4.
The thermostat will continue the 4-event program based on the present time and day.
To set and change the room temperature temporarily:
1. Press <or >at any time to change the desired temperature value. SET is shown in the display.
2. When releasing the <or >, the display returns to showing the actual temperature. This temperature change is
only temporary and will be maintained only until the next programmed setting!
A default program provides timer control if the customer does not create own programs:
Days Event 1 Event 2 Event 3 Event 4
Start time Temp. Start time Temp. Start time Temp. Start time Temp.
Mon - Fri 6:30 20° C
(27° C)* 8:30 15° C
(25° C)* 16:30 20° C
(27° C)* 22:30 15° C
(25° C)*
Sat - Sun 7:30 20° C
(27° C)* 9:30 20° C
(27° C)* 16:30 21° C
(28° C)* 22:30 15° C
(25° C)*
* Floor temperature control mode.
7 Check Floor Temperature
• Press Mand hold. Press <within 6 seconds.
• ashes and the current oor temperature is displayed. Operate again, then exit (automatic exit after 6
seconds with no operation).
8 Child Safety Lock
• Press Mand hold. Press >within 6 seconds to lock all buttons.
• Press again to exit the child safety lock.
9 Set Control Parameters
Press Mbutton for 6 seconds to enter the parameter setting mode. Press Mfor parameter selection and set the
parameter range via <or >. Complete all adjustments.
To exit WT-P/PR, press , which is available for this purpose (automatic exit after 30 seconds with no operation).
To exit WT-D/DR, wait for automatic exit (30 seconds). The upper digits indicate the parameter number.