Danish Interpretation Systems DCS 6000 User manual

DCS 6000
User Manual
Danish Interpretation Systems DIS
Digital Conference System
RP 6004 Repeater

Danish Interpretation Systems Operation manual
Copyright © 2003 Danish Interpretation Systems
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.

Danish Interpretation Systems Operation manual
Copyright © 2003 Danish Interpretation Systems
No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
List of Contents
List of Contents .....................................................3
Document version..............................................3
Important...............................................................4
Compliancy ........................................................4
Installation precautions.....................................4
Cleaning..............................................................4
Repacking...........................................................4
Warranty............................................................4
Description of the system......................................5
Features..............................................................5
System components ...........................................6
Central equipment............................................6
Interpreter and delegate equipment..................6
Unit operating instructions ..................................7
RP 6004 Repeater..............................................7
General description.......................................... 7
Features ........................................................... 7
User Controls, indications & connectors......... 7
System design.................................................. 8
System Setup.......................................................10
General guidelines...........................................10
Typical schematics ..........................................11
Large size conference microphone system.... 11
Various configurations with RP 6004 Repeater
and PS 6000 Power Supply........................... 12
Appendix.............................................................. 13
Technical appendix.........................................13
Cabling .......................................................... 13
Accessories (not supplied)............................. 13
Technical specifications ................................ 14
Document version
Printed: 03-11-2003 Version: B
Name: RP6004B.DOC

Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark
4
Important
Compliancy
The equipment has been tested and found to comply
with the limits of the following norms and
approvals:
•EN55013 of 2001 (emission)
•EN55020 of 2002 (immunity)
•EN60065 of 1998
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. The equipment generates, uses, and
can radiate radio frequency energy and if not
installed and used in accordance with the user
manual it may cause harmful interference to radio
communications.
You are cautioned that any changes or
modifications not expressly approved in this manual
could void your authority to operate this equipment.
Installation precautions
Allow adequate air circulation to prevent internal
heat built-up. Do not place the unit on a surface
(rugs, blankets, etc.) that may block the ventilation
holes.
Do not install the unit in a location near heat
sources such as radiators or air ducts, or in a place
exposed to direct sunlight, excessive dust or
humidity, mechanical vibration or shock.
To avoid moisture condensations do not install the
unit where the temperature may rise rapidly.
Cleaning
To keep the cabinet in its original condition,
periodically clean it with a soft cloth. Stubborn
stains may be removed with a cloth lightly
dampened with a mild detergent solution. Never use
organic solvents such as thinners or abrasive
cleaners since these will damage the cabinet.
Repacking
Save the original shipping carton and packing
material; they will become handy if you ever have
to ship the unit. For maximum protection, re-pack
the unit as originally packed from the factory.
Warranty
The individual units in the DCS 6000 system are
minimum covered by 12 months warranty against
defects in materials or workmanship.
.

Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark 5
Description of the system
Features
The DCS 6000 system has the following main
features:
•Fully digital
•Excellent sound quality
•“State of the Art” fully digital integrated
interpretation, discussion and voting system
offering interpretation, language distribution,
conference microphone and voting facilities
with attendance check with Chip Card ™.
•New, unique digital DATA and AUDIO bus.
•39 incoming channels (8 floor channels + 31
interpreted channels)
•33 distributed channel (2 x floor + 31
interpreted channels)
•The Delegate and Interpreter units are powered
and controlled by the CU 6010 Central Unit,
which drives up to app. 200 units on 4 chains.
•EX 6010 Extension Units or PS 6000 Power
Supplies available if more units are required
•A total of 4000 units (delegate or interpreter
units) can be connected to the system.
•Using screened CAT5 cabling (FTP or STP)
ensuring a very cost effective installation and
easy set-up of portable systems
•Firmware in Delegate units, Interpreter Units,
Central Units etc. upgradeable through RS232
on Central Unit
•Can be operated with or without a PC.
•Added functionality and comprehensive
features provided by SW 6000 software
package running on PC
RS232/RS422 connection on CU 6010 for
external operation of the system of a PC or
control system such as AMX or Crestron
The SW 6000 is an optional software package,
which expands the functionality of the DCS 6000
system. The software runs on standard computer
technology (Standard PC with Windows 2000 or
XP).
Main features of the SW 6000 are:
•Microphone management
•Mimic panel operation
•Interpretation management
•Voting management
•Message handling
•Agenda handling
•Data stored on SQL data base for easy
export/import of data as well as easy links to
external databases
•Multi language user interfaces
•Supports different user type with different
priorities, user interfaces and control
possibilities
•Variety of printing facilities such as speaker’s
log, voting results, delegates list etc.

Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark
6
System components
The DCS 6000 system consists of various units.
Central equipment
CU 6000 Central Unit with built-in DCS-LAN
controller and power supply
CU 6010 Central Unit with built-in DCS-LAN
and power supply
EX 6010 Extension Unit
PS 6000 Power Supply
AO 6008 Audio Output box
RP 6004 Repeater for four chains
Interpreter and delegate equipment
IS 6132P Interpreter Set
LS 6032P Interpreter Loudspeaker
CS 6032PChannel selector (portable)
CS 6032F Channel Selector (flush mounted)
DM 6010P Delegate Unit (portable)
DM 6070P Delegate Unit (portable) with two
built in channel selectors
CM 6010P Chairman Unit (portable)
CM 6060P Chairman Unit (portable) with one
built in channel selectors
MU 6040 Microphone Unit for use with
customised front plate with
Loudspeaker, Microphone and
Buttons. Available in Delegate (D)
and Chairman (C) version
JB 6002 Junction Box with 2 outputs
JB 6004 Junction Box with 4 outputs

Danish Interpretation Systems Operation manual
Manual 01 18 04466 Printed in Denmark 7
Unit operating instructions
RP 6004 Repeater
General description
The RP 6004 Repeater provides Repeater and
Splitter functionality for the DCS 6000 system. One
CU 6010 Central Unit is needed in each DCS 6000
system, however for expansion of the system the
RP 6004 Repeater is suitable.. The RP 6004 consist
of two main parts:
•Repeater /splitter board with 4 individual
repeated outputs
Features
The main features of the RP 6004 Repeater are:
•4 outputs for connection to Delegate Units,
Interpreter Units etc.
•Loop through connectors for connection
additional RP 6004 or other units, which are
part of the DCS 6000 system
•Delayed switching on of power to the four
chains, to minimise the total ‘switch-on’ current
on the Mains supply.
•Designed in compact cabinet for easy installing
remotely.
User Controls, indications & connectors
Front plate layout
Front plate controls
The RP 6004 Repeater does not feature any controls
or displays, however the following indications and
connectors are available:
qLoop through connectors
RJ45 connector, 2 pieces
DCS-LAN connectors for connection to the CU
6000/CU 6010 and for connection to other units
with DCS-LAN connector, such as more RP 6004.
qRepeated Chain 1, 2, 3 & 4
RJ45 connector, 4 pieces
DCS-LAN connectors for connection to
DM/CM6xxx, IS6032, CS6032, EX6010, AO6008
etc. For connecting Interpreter Sets for up to 16
languages. If more languages are required,
Interpreter sets for those languages have to be
connected to Chain B1 or B2.
qPower LED
Those LED light up when Power is available on the
connector next to the LED
qIncoming data LED
Those LED flashes, when the units received
incoming data from connected units on the
connector next to the LED.

Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
8
System design
There are no settings to be done on the RP 6004
Repeater.
However it is important to observe, that the unit is
only repeating one of the chains on the CU 6010
Central Unit.
And as so, the specification, which applies to each
of the chain outputs on the CU 6010 Central Units
does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004
Repeaters, bare in mind, that as the RP 6004
Repeater is repeating only one of the four outputs A
(A1 or A2) or B (B1 or B2) the max. number of
languages configured on the four outputs (1, 2, 3
and 4) is totally max. 16.
If more languages are required, Interpreter sets for
those languages have to be connected either to an
other RP 6004 Repeater, which is connected to the
other of the two chains (A or B) on the CU 6010, or
directly to the other of the two chains (A or B) on a
CU 6010.
‘Repeated chain’ connector
When connecting the RP 6004 Repeaters to the CU
6010 the first EX is connected to the ‘Loop
through’ connector. The next RP 6004 Repeaters
can be connected to either the other ‘Loop through’
connector or to one of the ‘Repeated out’
connectors. If using the ‘Repeated’ outputs two
more RP 6004 Repeaters can be connected
extending the maximum cable length in one chain
up to 680 m. The above schematic is showing the
connection using the ‘‘Repeated out’ connectors.

Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark 9
‘Loop through’ connector
When connecting a number of RP 6004 Repeaters
to the CU 6010 an almost unlimited number of EX
can be connected by using the ‘Loop through’
connector. The practical limitation is the maximum
cable length in one chain, which is 200 m. The
following schematic is showing the connections
using the ‘Loop through’ connectors.
A combination of the two methods of connection
can be seen in the section ‘Typical Schematics’.

Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
10
System Setup
General guidelines
Connect the RP 6004 to the various units using Cat
5 FTP or STP cables. Please observe the following
guide lines:
•Maximum cable length in one chain is 200
m without repeater. This includes
interconnection cables between the units.
The max. usable cable length depends on
the units connected and length of feeding
cables etc.
•Maximum cable length in one chain when
using repeaters is 680 m.
•As the RP 6004 Repeater is repeating only
one of the four outputs A (A1 or A2) or B
(B1 or B2) the max. number of languages
configured on the four outputs (1, 2, 3 and
4) is totally max. 16.
If more languages are required, Interpreter
sets for those languages have to be
connected to both chains (A or B) on the
CU 6010. Normally the languages are
supposed to be divided equally on chains A
(A1 or A2) and B (B1 or B2).
•If the last unit in one chain is a CS 6032
Channel Selector, this units has to be
terminated with an external termination, as
the CS 6032 does not have an internal
termination.

Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
11
Typical schematics
The following schematics are showing various configurations:
Large size conference microphone system

Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
12
Various configurations with RP 6004 Repeater and PS 6000 Power Supply

Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
13
Appendix
Technical appendix
Cabling
CAT5
The DCS 6000 system uses CAT5, CAT5e or
CAT6 FTP or STP cables/connectors. And EIA
568-Bwiring shall be used.
But use only FTP or STP cables/connectors and
not UTP.
How to wire a CAT5 (EIA 568-B) Cable:
Pin
Connector #1 Connector #2
1 ORG/WHT ORG/WHT
2 ORG ORG
3 WHT/GRN WHT/GRN
4 BLU BLU
5 BLU/WHT BLU/WHT
6 GRN GRN
7 BRN/WHT BRN/WHT
8 BRN BRN
Note. If other colour codes are used then the four
pairs are connected as follows:
Pair 1: Pin 1 & 2
Pair 2: Pin 3 & 6
Pair 3: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct.
Accessories (not supplied)
Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0,5 m .....................10 03 12500
EC 6000-01 Connection Cable 1 m ........................10 03 13101
EC 6000-02 Connection Cable 2 m ........................10 03 13201
EC 6000-05 Connection Cable 5 m ........................10 03 13501
EC 6000-10 Connection Cable 10 m ......................10 03 14102
EC 6000-20 Connection Cable 20 m ......................10 03 14202
EC 6000-50 Connection Cable 50 m ......................10 03 14502

Danish Interpretation Systems Appendix
Manual 01 18 04466 Printed in Denmark
14
Technical specifications
General
Power consumption .................................................max. 10VA
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight.............................................................................. 5,5 kg
Dimensions (W x H x D)............................ 264 x 42 x 128 mm
Accessories supplied...............................................User manual
..................................................................................Main cable
Connectors
DCS-LAN loop through........................................2 pieces RJ45
DCS-LAN repeated output....................................4 pieces RJ45
Specifications are subject to change without notice.
Other manuals for DCS 6000
15
This manual suits for next models
1
Table of contents