Simrad RD 301 User manual

RD301 User manual
Remote display RD301
Digital depth repeater
Instruction manual

RD301 User manual
INTRODUCTION
The RD301 remote display is made for use with the EA400/
EA600 and the EN 250 navigation echo sounder. It may also be
used with other echo sounders, if they have NMEA0183 output.
The RD301 is a depth repeater with alarm setting. The operator
may select alarm depth in the meny.
Maximum depth readings are 9999 m and a resolution of 0.1 m.
Brightness is adjusted on the front panel. Brightness can,
optionally, also be adjusted from a remote controller.
OPERATION
1. To switch the unit on: Press any key.
To switch the unit off: At the same time, press both the Up
and the Down key.
2. To adjust brigthness: Press the Up/Down keys to find suitable
setting.
3. Toselectdepthalarm:PresstheSkeyonceandenteralarmsetting
mode. The display shows “SetA“. Set the wanted depth by
using the Up and Down keys. When wanted alarm depth is
set, the unit will go back to normal mode operation after 15
seconds, or press Sto the depth occur. When depth below
transducer become the same, or less, than the alarm depth,
the display will indicate “AL“ alternating with actual depth.
To set alarm off: Repeat operation number 3. and set alarm
depth to 0 m.
4. To select readings in feet, meters or fathoms: Press the Skey
twice and enter alarm setting mode. The display shows “SetU “.
Select requested reading by pressing the Up or Down key. When
readings is set, the unit will go back to normal mode operation
after 15 sec, or press Sto the depth occur.
5. To select transducer position (Only for EN 250): Press the S
key three times and enter the transducer selection mode. The dis-
play shows “SetP”. Press the Up/Down keys to select between
the four choices: Unknown, Forward, Backward or Auto.
- The Unknown selection decode any NMEA depth message and
shows the depth on the display. The position leds will then be
off.
- The other selections decode the NMEA message $PSKPDPT.
If Forward is selected, only the readings from the forward
transducer is shown, and if Backward is selected, only the
readings from the backward transducer is shown.
- The Auto selection switches between Forward, Backward
and Unknown depending on the NMEA messages available.
The led for positions will shift automatically and blink every
third second, indicating that the Auto selection is active. If
the transducer position is unknown, both leds will be on and
blinking.
1 857-164821aa

RD301 User manual
Cable length: 1.5m. (4.9 ft.)
70(2.736)
Tab size 6.3 x 0.8
50(1.968)
70(2.736)
1
(CD7018)
62(2.441)
13(0.492)
Ground stud 4M x 12
Nut M4
Washer DIN 6797 (2x)
2
NMEA Input
1. Accepted messages (NMEA0183,version 2.30),
talker identifier is not processed:
- Depth &Draught
SDDPT,xxxx.x,xxxx.x,xxxx.x <Cr><Lf>
(used by EA400 and EA600)
- Depth below transducer
SDDBT ,xxxx.x,f,xxxx.x,M,xxx.x,F)
- Depth below transducer by EN 250
proprietary sentence shown to the left
(only for EN 250)
PANEL MOUNTING
AMake a cut out in the Panel (5): 125 x 125 mm.
BRemove the mounting bracket (1).
CUnscrew the 4 screws in the frame (3) (one in each corner)
and remove the frame.
DPut the Monitor (4) in the cut out and mark the 4 center-
points for the drill in the Panel (1)(2). (The drilling holes
diam. depends on thickness and material in the Panel).
EUse appropriate bolts with diameter 2.9 mm. Length
depends on the Panel thickness.
FFinally put on the frame (3). Make sure that the screw
heads correspond with the cut outs in the frame.
Before fixing the monitor (4) in the cut out area in console
(1)(2), apply sufficient amount of water sealant compound
between the monitor (4) and console (1)(2). Before the
frame (3) is remounted, apply sufficient amount of water
sealant compound in the inner area of the frame and on the
edges of the monitor (4), to ensure that water can not pen-
etrate into the monitor (4). The front panel of the monitor
is waterproof.
Transducer location *
Echo sounder channel number (0-99)
Bottom echo strength (0,9)
Maximum range scale in use, meters
Offset from transducer, meters
Water depth relative to transducer, meters
* Text string, indicating transducer position: FWD/AFT/PORT/STB.
If position is not preset by operator, empty field is provided.
$PSKPDPT,x.x,x.x,x.x,xx,xx,c-c*hh<CR><LF>
(Cd7019)
Some remote displays may have the text “REMOTE DISPLAY” instead of
“RD301” on the front.
S
ft
M
F
RD301
144 [5,669]
144 [5,669]
100(3.937)
5
S
RD301
F
ft
M
132,5 [5,217]
125 [4,921]
Cut out
The drilling holes diam. depends on thickness and material in the Console.
Hole diam. %%C4.0 (0.157)
125 [4,921]
4
3
96 [3,780]
Mounting bracket
857-164821aa 2

RD301 User manual
About this manual
Kongsberg Simrad AS makes
every effort to ensure that the
information contained within
this document is correct.
However, our equipment is
continuously being improved
and updated, so we cannot
assume liability for any errors
which may occur.
Note about wiring
A wrong type of cable has been used in the production of the first
series of RD301 repeaters. This applies to repeaters with serial
no. 030031 through 030050.
Two of the wires in the cable have a different
colour coding from the original:
- NMEA IN/OUT Brown wire
(originally white)
- DIMKEY Violet wire
(originally grey)
Other cables as marked on the rear wall of the
repeater.
GROUND WITH GROUND STUD
RED
BLUE
WHITE
BLACK
COLOUR
ORANGE
GREEN
GREY
DIM+
DIM-
COLOUR
YELLOW
DIMKEY
WIRING CONNECTING
SIGNAL
NMEA IN+
NMEA IN/OUT-
NMEA OUT+
+ 24V
- 24V
SIGNAL
DIMKEY
REMOTE
DIMMER
DIM-
DIM+
Environmental conditions according to
IEC60945
Supply voltage: 24 Vdc (20-32 V)
Power consumption: 3 W at 24 V
Display area, size: 20 x 11 mm
Operating temperature:
-15 to +55 degree C, according to IEC60945. To increase service
ability and life-time, we suggest the working temperature to be
held at 0 to +40 degrees C.
Storage temperature: -20 to +70 degree C
Humidity: 10 - 90% relative, no condensation
Protection: IP 56
Warning
The equipment to which this
manual applies must only be
used for the purpose for which
it was designed. Improper use
or maintenance may cause
damage to the equipment or
injury to personnel. The user
must be familiar with the
contents of the appropriate
manuals before attempting to
install, operate or maintain the
equipment.
Kongsberg Simrad AS dis-
claims any responsibility for
damage or injury caused by
improper installation, use or
maintenance of the equipment.
Service
All service requests should
be made to the local Kongs-
berg Simrad representative.
Adjustments and repairs
should only be performed by
qualified service engineers,
and unqualified repair attempts
will void the warranty.
Copyright
© 2003 Kongsberg Simrad AS
The information contained
within this document remains
the sole property of Kongs-
berg Simrad AS. No part of
this document may be copied
or reproduced in any form or
by any means, and the infor-
mation contained within is
not to be communicated to a
third party, without the prior
written consent of Kongsberg
Simrad AS.
Generic RS-232 Serial line
This cable comprises a multi-purpose serial
line. It provides interface with any peripheral
unit. One end of the cable connects to the local
unit (DTE) with a 9-pin ‘D’ connector, while
the other connects to the peripheral (DCE) as
described in the peripheral unit’s documenta-
tion.
Note that this cable does not support all the sig-
nals in the standard RS-232 specification.
W103 / Rev G Standard RS-232 serial line
2
3
5
Rx
Tx
Ground
View
Local (DTE) 9-pin
‘D’ connector
Remote unit (DCE) to
be connected as described
in applicable documentation
Looking into
female 9-pin
D-pin connector
51
6
9
Looking into
male 9-pin
D-pin connector
15
96
Screen
To plug housing
3 857-164821aa
Table of contents
Other Simrad Repeater manuals
Popular Repeater manuals by other brands

Ampac
Ampac FireFinder NZS 4512 user manual

Kenwood
Kenwood NEXEDGE NXR-900-K instruction manual

C&C TECHNIC
C&C TECHNIC Smart View Intelligent KVM-S1 user manual

Cellphone-Mate
Cellphone-Mate CM2020 68 dB user manual

Nikrans
Nikrans BD-5000-Voice 3G PRO quick start guide

Edimax
Edimax RE-7478RPC Quick installation guide