________________________________________________________________________________
Page 2 OSRAM Operating Instructions DALI REPEATER SO
Contents
Installation
Operation
Appendix
Contents................................................................................................................. 2
Application and function.......................................................................................... 2
Safety information................................................................................................... 2
Design and dimensions .......................................................................................... 4
Wiring schemes ...................................................................................................... 4
DALI operation with supervisory control unit ........................................................... 6
Touch DIM operation .............................................................................................. 6
Load switch ............................................................................................................ 7
Functional test ........................................................................................................ 7
Service button ........................................................................................................ 7
Indication LED ........................................................................................................ 8
Accessories (not included)...................................................................................... 8
Technical data ........................................................................................................ 9
Application and function
The DALI REPEATER SO allows to build up DALI systems with more than 64 ECG per DALI line. For
the supervisory control unit it acts like a single ECG. On the other hand it is able to control up to
64 DALI ECG. All ECG connected to the DALI REPEATER SO are set to the same dimming level.
Switching state, dimming level and lamp failures can be queried via the Repeater. At the same time it
allows the extension of the DALI line by 300 m each time. If the Repeater is used in Touch DIM
operation, up to 64 DALI ballasts can be controlled by means of a common push button.
The integrated load switch can be used to interrupt the mains power supply of the connected ECG.
The switch will be opened if the connected ECG are in stand-by operation for a while. By this the
stand-by power of the installation can be reduced.
The DALI REPEATER SO is designed for switchboard installation.
Safety information
The following information is provided for your safety:
Please read these operating instructions carefully before installing and using the DALI
REPEATER SO. This is the only way to ensure that you use the equipment safely and
correctly. Keep these operating instructions in a safe place for future reference. You should
make sure that everyone who uses DALI REPEATER SO has read these operating
instructions.
DALI REPEATER SO may only be installed by qualified personnel who have been
appropriately trained and who have the relevant authority. The installation personnel must
be familiar with the operating instructions. Power must be switched off before any work is
undertaken on the unit.
The DALI REPEATER SO is designed for installation in switchboard.
The relevant safety and accident prevention regulations must be observed.
The Touch DIM operation must not be used in parallel to operation with a DALI control unit.
Only DALI or Touch DIM operation is allowed.
The external switch for the Touch DIM operation must be designed for mains voltages.
Operating Instructions DALI REPEATER SO
The following information is provided for your safety:
• Please read these operating instructions carefully before installing and using the DALI RE-
PEATER SO. This is the only way to ensure that you use the equipment safely and correctly.
Keep these operating instructions in a safe place for future reference. You should make sure
that everyone who uses DALI REPEATER SO has read these operating instructions.
• DALI REPEATER SO may only be installed by qualied personnel who have been appropria-
tely trained and who have the relevant authority. The installation personnel must be familiar
with the operating instructions. Power must be switched off before any work is undertaken
on the unit.
• The DALI REPEATER SO is designed for installation in switchboard.
• The relevant safety and accident prevention regulations must be observed.
• The Touch DIM operation must not be used in parallel to operation with a DALI control unit.
Only DALI or Touch DIM operation is allowed.
• The external switch for the Touch DIM operation must be designed for mains voltages.
• If the DALI output is wired with external voltage, particularly with a mains voltage, the unit
may be destroyed.